First results from plasma density measurements in the FTU tokamak by means of a two-frequency pulsed time-of-flight refractometer

A pulsed time-of-flight refractometer was developed and tested to determine the mean plasma density in the T-11M tokamak by measuring the propagation time of nanosecond microwave pulses in plasma. Later, it was also proposed to use such an instrument to measure and control the mean plasma density in the ITER tokamak by probing the plasma with an extraordinary wave, the electric field of which is perpendicular to the magnetic field in plasma, in the transparency window at frequencies of 50-100 GHz. To avoid the effect of the density profile shape on the measurement results in the nonlinear mode of refractometer operation (near the cutoff), a system operating at two different probing frequencies was developed and tested. Such a system provides two values of the time delay, which can be used to estimate the peaking factor of the density distribution {alpha} and correctly determine the linear density Left-Pointing-Angle-Bracket Nl Right-Pointing-Angle-Bracket , regardless of the density profile (assuming a smooth density profile of the form of N({rho}) = N(0)(1 - {rho}{sup 2}){sup {alpha}}, where N(0) is the central plasma density and {rho} = r/a is the normalized plasma radius). The first experiments on density measurements in the FTU tokamak performed with this refractometer are described, and results from these experiments are presented. The formation of a thin dense plasma layer in the zone of a strong magnetic field (the so-called MARFE layer) at a relatively low (for FTU) plasma density of {approx}6 Multiplication-Sign 10{sup 19} m{sup -3} was detected. The thickness of this layer, determined from the refractometry data, agrees well with the data obtained using a digital camera.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in the FTU collective Thomson scattering system

The new collective Thomson scattering diagnostic installed on the Frascati Tokamak Upgrade device started its first operations in 2014. The ongoing experiments investigate the presence of signals synchronous with rotating tearing mode islands, possibly due to parametric decay processes, and phenomena affecting electron cyclotron beam absorption or scattering measurements. The radiometric system, diagnostic layout, and data acquisition system were improved accordingly. The present status and near-term developments of the diagnostic are presented.

43 PARTICLE ACCELERATORS↗

Experimental observation of increased threshold electric field for runaway generation due to synchrotron radiation losses in the FTU tokamak

The threshold electric field for runaway generation has been investigated during runaway suppression experiments by means of electron-cyclotron-resonance heating in the flattop phase of FTU discharges. Runaway suppression has been experimentally found to occur at electric fields substantially larger than those predicted by the relativistic collisional theory of runaway generation, E{sub R} = n{sub e}e{sup 3}ln{Lambda}/4{pi}{var_epsilon}{sub 0}{sup 2}m{sub e}c{sup 2}. These experimental results are consistent with an increase of the critical electric field due to the electron synchrotron radiation losses. No runaway electrons are found in FTU experiments below the radiation threshold. These results support evidence for a new threshold electric field for runaway generation that accounts for the effect of the synchrotron losses, and which should be considered when making predictions on runaway generation and mitigation in devices such as ITER.

43 PARTICLE ACCELERATORS↗

Lower hybrid current drive favoured by electron cyclotron radiofrequency heating

The important goal of adding to the bootstrap a fraction of non-inductive plasma current, which would be controlled for obtaining and optimizing steady-state profiles, can be reached by using the Current Drive produced by Lower Hybrid waves (LHCD). FTU (Frascati Tokamak Upgrade) experiments demonstrated, indeed, that LHCD is effective at reactor-graded high plasma density, and the LH spectral broadening is reduced, operating with higher electron temperature in the outer region of plasma column (T{sub e-periphery}). This method was obtained following the guidelines of theoretical predictions indicating that the broadening of launched spectrum produced by parametric instability (PI) should be reduced, and the LHCD effect at high density consequently enabled, under higher (T{sub e-periphery}). In FTU, the temperature increase in the outer plasma region was obtained by operating with reduced particle recycling, lithized walls and deep gas fuelling by means of fast pellet. Heating plasma periphery with electron cyclotron resonant waves (ECRH) will provide a further tool for achieving steady-state operations. New FTU experimental results are presented here, demonstrating that temperature effect at the plasma periphery, affecting LH penetration, occurs in a range of plasma parameters broader than in previous work. New information is also shown on the modelling assessing frequencies and growth rates of the PI coupled modes responsible of spectral broadening. Finally, we present the design of an experiment scheduled on FTU next campaign, where ECRH power is used to slightly increase the electron temperature in the outer plasma region of a high-density discharge aiming at restoring LHCD. Consequent to model results, by operating with a toroidal magnetic field of 6.3 T, useful for locating the electron cyclotron resonant layer at the periphery of the plasma column (r/a∼0.8, f{sub 0}=144 GHz), an increase of T{sub e} in the outer plasma (from 40 eV to 80 eV at r/a∼0.8) is expected by the JETTO code, sufficient for recovering LHCD. An ECRH power of 0.8 MW, and the standard FTU regime at high plasma density (n{sub eav}∼1.3×10{sup 20}m{sup −3} and plasma current of 0.5 MA) have been considered. The code has been set with transport modelling to reproduce the evolution of FTU kinetic profiles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dust Measurement With Thomson Scattering In FTU

The size distribution of dust particles present in FTU after disruptions has been evaluated in the range 0.05 {mu}m-0.1 {mu}m using the Thomson scattering system. Rayleigh approximation has been used to estimate the dust size. The distribution, although the radii considered do not differ more than an order of magnitude, behave like a power law. The laser energy density far exceed that necessary to vaporize, at least partially, the particles. This can affect the previous estimate of the particle sizes, and suggests that the effective radii might be larger than the estimated values. A preliminary analysis on the broad band signal is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MHD Activity in FTU Discharges With a Liquid Lithium Limiter

Experiments on plasma configurations with Liquid Lithium Limiter (LLL) have been performed on FTU to investigate liquid lithium facing the plasma. The liquid lithium surface with capillary porous system (CPS) has been inserted in the scrape off layer (SOL) of the FTU vacuum chamber in various plasma discharges. MHD activity in discharges with and without LLL has been investigated and compared. The main MHD effect observed with LLL is a reduction of the amplitude of tearing modes with poloidal (toroidal) number m = 2 (n = l). The magnetic activities in FTU are analysed by means of a set of poloidal field pick-up coils. A total of 57 coils are installed at various toroidal and poloidal positions. In this paper we will describe in details the diagnostic apparatus and experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MHD Structure Analysis by Singular Value Decomposition as a Tool for ECRH RT-Control of Instabilities on FTU

In this work we present the results obtained applying Singular Value Decomposition (SVD) on a Mirnov coil array in FTU discharges where experiments on MHD stabilization or disruption avoidance via ECRH were performed. In these shots the mode analysis has been consolidated off line by means of FFT and SXR-tomography. Although the Mirnov setting was not necessarily optimised, results show that the algorithm based on SVD is able to detect the mode with a precision equal or better than the FFT, while acting on a smaller time interval. The short execution time required, even in the present preliminary form, suggests that this analysis can be a suitable tool to be implemented in a real time control chain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗