Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FRMAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

FRMAC Assessment Manual Volume 1 Overview and Methods

The Federal Radiological Monitoring and Assessment Center (FRMAC) Assessment Manual is the tool used to organize and guide activities of the FRMAC Assessment Division. The mission of the FRMAC Assessment Division in a radiological emergency is to interpret radiological data and predict worker and public doses. This information is used by Decision Makers to recommend protective actions in accordance with Protection Action Guides (PAGs) issued by government agencies. This manual integrates many health physics tools and techniques used to make these assessments.

61 RADIATION PROTECTION AND DOSIMETRY↗

FRMAC Assessment Manual Volume 1 (Overview and Methods)

The Federal Radiological Monitoring and Assessment Center (FRMAC) Assessment Manual is the tool used to organize and guide activities of the FRMAC Assessment Division. The mission of the FRMAC Assessment Division in a radiological emergency is to interpret radiological data and predict worker and public doses. This information is used by Decision Makers to recommend protective actions in accordance with Protection Action Guides (PAGs) issued by government agencies. This manual integrates many health physics tools and techniques used to make these assessments.

54 ENVIRONMENTAL SCIENCES↗

Turbo FRMAC Implemetation of IAEA Radiological Assessment Methodologies for Nuclear and Radiological Emergencies.

This report documents the findings of an assessment of the Turbo FRMAC software's ability to implement International Atomic Energy Agency (IAEA) guidance for calculating Operational Intervention Levels (OIL) 1 & 2 for nuclear and radiological emergencies. The IAEA OIL and U.S. Federal Radiological Monitoring and Assessment Center (FRMAC) Derived Response Level methodology and implementation in respective tools were compared, as demonstrated through benchmarking activities for a nuclear power plant source term and potential radionuclides of concern for radiological dispersal devices. This comparison revealed some shortcomings in Turbo FRMACs ability to perform IAEA OIL calculations and resulted in recommended software modifications to be considered for future development.

61 RADIATION PROTECTION AND DOSIMETRY↗

FRMAC Mission Analysis: What is it, and why is it useful?

In 2002, the Director of the U.S. Department of Energy's (DOE's) National Nuclear Security Administration, Division of Emergency Response, requested a team of DOE scientists, considered experts in the field of radiological consequence management, assemble and construct a mission analysis upon which the DOE could build its response program and plan for future requirements. The team developed five scenarios upon which to build the data quality objectives (DQOs) that they considered necessary to ensure a comprehensive consequence management response from the DOE perspective. The resulting document was called the Consequence Management Mission Analysis. Based upon the positive reaction to this document and its obvious benefit to the Consequence Management mission, it was decided to expand the scope of the document to cover a mission analysis of the entire Federal Radiological Monitoring and Assessment Center (FRMAC) mission. The documentation team was expanded to include representatives from all signatories to the National Response Plan who have a role in responding to radiological emergencies. The scope of the FRMAC Mission Analysis includes all federal response resources which are activated to provide rapid support to affected state and local governments in the form of radiological monitoring and dose assessment activities at the incident site. An analysis of the necessary resources was performed to determine the required numbers and types of responders, in addition to the procedures and equipment necessary for performing the monitoring and dose assessment activities from the time the federal assets arrive at the site through the first week of the incident. The five scenarios that were considered were: (1) Nuclear Detonation; (2) Nuclear Reactor Incident or Event Involving Significant Release; (3) Alpha Radiological Dispersal Devise or Failed Improvised Nuclear Device; (4) Beta-Gamma Radiological Dispersal Device; and (5) Psychological Threat.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FRMAC Laboratory Analysis Rad Responder Enhancements Requirements

This document will describe the requirements for improvements to the Rad Responder platform to meet the needs of FRMAC Lab Analysis and other users of the sample control and lab analysis modules. The report is broken down into specific sections and organized by the specific deliverables under the FY19 FEMA-NIRT project. This report describes requirements that go beyond what was originally funded under the FY19 FEMA-NIRT project since auxiliary funding is being used on top of FEMA-NIRT funding through the DOE eFRMAC working group. This document describes all the lab analysis requirements for FRMAC Lab Analysis operations. Under each section the reader will find specific user "stories" or use-cases along with specific and technical requirements for each feature. Mock ups and data models will be provided as needed.

97 MATHEMATICS AND COMPUTING↗

Analytical Action Level Calculator in Turbo FRMAC (FY2020 Close-Out) [Slides]

Objectives: Automate the labor-intensive process of generating Analytical Action Levels (AALs) in Turbo FRMAC to shorten the timeline for planning sampling campaigns and sample analysis during a response. Make the tool output results in a format that is easily imported to RadResponder as a Mixture for use in Analysis Request Forms. Deliver training to EPA on using this new tool in Turbo FRMAC (Delayed due to COVID.

42 ENGINEERING↗

Opportunities for Improvement in FRMAC's Assessment Method for Ingestion of Contaminated Crops

This report provides recommendations to improve the assessment method of the Federal Radiological Monitoring and Assessment Center (FRMAC) for the ingestion of crops contaminated with radionuclides. The current FRMAC method of calculating investigation levels (ILs) and crop derived response levels (DRLs) is detailed. Recommended modifications to these calculations are presented based on the following aspects: handling radionuclide mixtures, no immediate equilibrium, washing of contaminated crops, and updated dietary intake rates.

54 ENVIRONMENTAL SCIENCES↗

FRMAC Laboratory Analysis Manual Volume 1, Revision 0

This manual is written for personnel who respond to a nuclear/radiological incident and will be called upon to provide support to ensure that samples receive appropriate laboratory analyses. Overall, this manual provides general guidance and some specific diagrams and forms. However, it is understood that site- and incident-specific operational decisions and procedures may need to be modified at the time of the incident. This manual is intended to provide guidance for laboratory analysis personnel without limiting FRMAC’s ability to integrate the work with other partners and stakeholders. Some of the titles of management positions with the FRMAC have been changed in order to comply with the structure of the Incident Command System (ICS) under the National Incident Management System (NIMS).

61 RADIATION PROTECTION AND DOSIMETRY↗

Turbo FRMAC 2016 Version 7.1.0

The Turbo FRMAC (TF) software program is the software implementation of the science and methodologies utilized in the Federal Radiological Monitoring and Assessment Center (FRMAC). The software automates the calculations described in volumes 1 of "The Federal Manual for Assessing Environmental Data during a Radiological Emergency" (2015 version). In the event of the intentional or accidental release of radioactive material, the software is used to guide and govern the response of the Federal, State, Local, and Tribal governments. The manual, upon which the software is based, is unclassified and freely available on the Internet.

Fulton, John↗

Turbo FRMAC 2016 v. 7.3.0

The Turbo FRMAC (TF) software program is the software implementation of the science and methodologies utilized in the Federal Radiological Monitoring and Assessment Center (FRMAC). The software automates the calculations described in volumes 1 of "The Federal Manual for Assessing Environmental Data during a Radiological Emergency" (2015 version). In the event of the intentional or accidental release of radioactive material, the software is used to guide and govern the response of the Federal, State, Local, and Tribal governments. The manual, upon which the software is based, is unclassified and freely available on the Internet.

Madrid, Gregory J.↗

Turbo FRMAC 2016 v. 7.2.0

The Turbo FRMAC (TF) software program is the software implementation of the science and methodologies utilized in the Federal Radiological Monitoring and Assessment Center (FRMAC). The software automates the calculations described in volumes 1 of "The Federal Manual for Assessing Environmental Data during a Radiological Emergency" (2015 version). In the event of the intentional or accidental release of radioactive material, the software is used to guide and govern the response of the Federal, State, Local, and Tribal governments. The manual, upon which the software is based, is unclassified and freely available on the Internet.

Madrid, Gregory J.↗

Turbo FRMAC 2018

The Turbo FRMAC (TF) software program is the software implementation of the science and methodologies utilized in the Federal Radiological Monitoring and Assessment Center (FRMAC). The software automates the calculations described in volumes 1 of "The Federal Manual for Assessing Environmental Data during a Radiological Emergency" (2015 version). In the event of the intentional or accidental release of radioactive material, the software is used to guide and govern the response of the Federal, State, Local, and Tribal governments. The manual, upon which the software is based, is unclassified and freely available on the Internet.

Fulton, John↗

FRMAC Familiarization Data Products

FRMAC familiarization workshop for a group of public health/medical personnel from the Centers for Disease Control and Prevention (CDC) in Atlanta, GA.

99 GENERAL AND MISCELLANEOUS↗

FRMAC Assessment Manual Volume 1: Overview and Methods

This Federal Radiological Monitoring and Assessment Center (FRMAC) Assessment Manual has been prepared by representatives of those Federal and State agencies that can be expected to play the major roles during a radiological emergency. Federal Agencies include: the National Nuclear Security Administration (NNSA), the Nuclear Regulatory Commission (NRC), the Environmental Protection Agency (EPA), the Department of Agriculture (USDA), the Food and Drug Administration (FDA), and the Centers for Disease Control (CDC). This final manual was reviewed by experts from across the community and their input has been incorporated.

61 RADIATION PROTECTION AND DOSIMETRY↗

FRMAC Gamma Spectroscopist Knowledge Guide. Revision 0.

This knowledge guide was developed as a training and reference manual for Federal Radiological Monitoring and Assessment Center (FRMAC) gamma spectroscopists. The knowledge guide is geared towards applied High Purity Germanium (HPGe) gamma spectroscopy with an emphasis on examples. As such, the knowledge guide generally provides a limited but sufficient discussion of physics concepts. For more detailed information on the physics concepts discussed in this guide, please refer to the references listed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FRMAC Assessment Manual Volume 3 - Pre-Assessed Default Scenarios

This volume of the Federal Radiological Monitoring and Assessment Center (FRMAC) Assessment Manual was developed to serve as a quick-start guide to expedite response for pre-assessed scenarios before event-specific information becomes available. The objective of Volume 3 is to provide dose assessors with the scenario-specific protective action guidance questions likely to be asked at the start of a response, along with supporting technical information and assumptions that differ from the default assumptions defined in Volume 2 of the Assessment Manual.

61 RADIATION PROTECTION AND DOSIMETRY↗

FRMAC Interactions During a Radiological or Nuclear Event

During a radiological or nuclear event of national significance the Federal Radiological Emergency Monitoring and Assessment Center (FRMAC) assists federal, state, tribal, and local authorities by providing timely, high-quality predictions, measurements, analyses and assessments to promote efficient and effective emergency response for protection of the public and the environment from the consequences of such an event.

61 RADIATION PROTECTION AND DOSIMETRY↗

Turbo FRMAC 2011

The Turbo FRMAC (TF) software automates the calculations described in volumes 1-3 of "The Federal Manual for Assessing Environmental Data During a Radiological Emergency" (2010 version). This software automates the process of assessing radiological data during a Federal Radiological Emergency. The manual upon which the software is based is unclassified and freely available on the Internet. TF takes values generated by field samples or computer dispersion models and assesses the data in a way which is meaningful to a decision maker at a radiological emergency; such as, do radiation values exceed city, state, or federal limits; should the crops be destroyed or can they be utilized; do residents need to be evacuated, sheltered in place, or should another action taken. The software also uses formulas generated by the EPA, FDA, and other federal agencies to generate field observable values specific to the radiological event that can be used to determine where regulatory limit values are exceeded. In addition to these calculations, TF calculates values which indicate how long an emergency worker can work in the contaminated area during a radiological emergency, the dose received from drinking contaminated water or milk, the dose from eating contaminated food, the does expected down or upwind of a given field sample, along with a significant number of other similar radiological health values.

Fulton, John↗