Engineering PapersSearch

SEARCH · Engineering Papers

Results for “FREQUENCY STABILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Frequency-Stabilized CO2 Lasers, Phase I

Frequency-stabilized carbon dioxide laser - electronic and mechanical stabilization schemes, control loop techniques, wavelength and mode control, and general laser construction

CARBON DIOXIDE

Measurements of a deep space station fractional frequency stability to the 10 exp -15 level

This article presents techniques for measuring frequency stability of a deep space station that was configured with a new X-band transmitter subsystem to enable high-quality radio science data to be obtained for a Gravity Wave Experiment. The instrument and test procedures for performing frequency stability measurements in the field are described. Test results from measurements made on various transmit receive subsystems, as well as the overall transmit-receive end-to-end systems below the antenna feed horn are presented. The subsystem test data proved to be useful for assessing the frequency stabilities of various subsystems. This assessment design improvements needed to meet stringent frequency stability requirements for forthcoming gravity wave experiments.

Otoshi, Tom Y.

The CO2 laser frequency stability measurements

Carbon dioxide laser frequency stability data are considered for a receiver design that relates to maximum Doppler frequency and its rate of change. Results show that an adequate margin exists in terms of data acquisition, Doppler tracking, and bit error rate as they relate to laser stability and transmitter power.

Johnson, E. H., Jr.

Frequency stabilization of a high power argon laser.

A technique for frequency stabilizing a high power, single frequency argon laser is described which offers certain advantages over those that have already been reported. This system is capable of maintaining a relative short term frequency stability of the order of plus or minus two parts in one billion and a long term stability (2 hr) of about plus or minus five parts in one billion for the 5145-A line at a power level of 750 mW. This short and long term stability is achieved by means of a multiple feedback loop composed of an optical cavity discriminator which is stabilized against an iodine vapor absorption line.

Hohimer, J. P.

Measurement of the frequency stability of responders in aircraft

Measurement on an aircraft orbit, such as a satellite launching orbit, is made by the responder in the aircraft along with several remote track stations on the ground. During the launching, the system is required to have precise time synchronization and frequency accuracy. At the same time, accurate measurement of aircraft velocity requires high frequency stability of the system. However, atomic frequency standards in the ground stations supply time and frequency reference standard with excellent long term and short term frequency stability for the above-mentioned goals. The stability of responder is also an important factor affecting the performance of the system and there are more requirements for the corresponding time/frequency measurements. In the system, the responders do not use continuous wave (CW) but narrow pulse modulated wave; consequently, the characterization theory of their stability is more complicated and the measurement technique is more difficult for pulsed wave than that for CW. A systematic characterization theory of the frequency stability for pulsed wave is demonstrated and the measuring methods are discussed. The measurement systems, which have been set up in Beijing Institute of Radio Metrology and Measurement (BIRMM) and can be used to test the frequency stability of pulse coherent responders in time domain and frequency domain with high sensitivity and accuracy, are described. Using these measurement systems, successful measurements for the responders were made with which the satellite launching orbits were precisely obtained and tracked.

Liu, Xiaofan

The measurement system of pulse modulated carrier frequency stability and timing jitter

The definition of pulse modulated carrier frequency stability and timing jitter as well as the configuration and synchronous acquisition measurement method of its measurement system. Frequency stability of the pulse modulated carrier is measured with a discrimination technique. The pulse modulated carrier under testing is mixed with a reference frequency synthesizer. A delay line is used to convert the frequency fluctuation mixed IF signal to the voltage fluctuation. The system has the capability to make the phase noise measurement of two port devices on a pulsed carrier using a phase bridge. The noise voltage mentioned above is applied to the data acquisition and processing unit by PC to realize stability measurement. The data acquisition is in the form of pulse synchronization so that the measurement system accuracy is increased. The pulse width is more than 0.3 microseconds. The phase fluctuation variance, sigma, is less than 0.017. The time interval measuring system with high resolution is used to make interpulse timing and pulse width jitters automatic measurement. The pulse width is less than 0.2 ns. The resolution is 0.1 ns. The system is successfully applied to radar measurement.

Li Cheng-Fu

DSS 13 frequency stability tests

In a previous article, the results of frequency stability tests at DSS 13 were presented in table form for tau = 1000 s for the test period May 1985 through March 1986. This article is a continuation of that initial report and presents specially selected Allan sigma (square root of variance) plots of each of the subsystem test previously reported. An additional result obtained from tests performed during July 1986 was included for completeness. The Allan sigma plots are useful in that frequency stability information is not only given for tau = 1000 s, but for tau values in the regions of 1, 100, 500, and 2000 s as well.

Otoshi, T. Y.

On-orbit frequency stability analysis of the GPS NAVSTAR-1 quartz clock and the NAVSTARs-6 and -8 rubidium clocks

An on-orbit frequency stability performance analysis of the GPS NAVSTAR-1 quartz clock and the NAVSTARs-6 and -8 rubidium clocks is presented. The clock offsets were obtained from measurements taken at the GPS monitor stations which use high performance cesium standards as a reference. Clock performance is characterized through the use of the Allan variance, which is evaluated for sample times of 15 minutes to two hours, and from one day to 10 days. The quartz and rubidium clocks' offsets were corrected for aging rate before computing the frequency stability. The effect of small errors in aging rate is presented for the NAVSTAR-8 rubidium clock's stability analysis. The analysis includes presentation of time and frequency residuals with respect to linear and quadratic models, which aid in obtaining aging rate values and identifying systematic and random effects. The frequency stability values were further processed with a time domain noise process analysis, which is used to classify random noise process and modulation type.

Mccaskill, T. B.

Simple approach to laser frequency stabilization

We describe a simple approach to laser frequency stabilization. It was originally developed for the metrology subsystem for NASA's StarLight mission, a space-based separated-spacecraft stellar interferometer.

starlight

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting

DSS 13 frequency stability tests performed during May 1985 through March 1986

Results of station frequency stability testing performed at DSS 13 (Deep Space Station) during May 1985 through March 1986 are presented. The testing was done on X-band uplink and X- and S-band downlink subsystems as well as on end-to-end systems. The subsystem test data are useful for assessing the frequency stability of various prototype X-band uplink or downlink subsystems for purposes of making design improvements. Information derived from extensive testing at DSS 13 will be useful in the preparation of an X-band Uplink Demonstration Experiment to be conducted at DSS 13, and will also be valuable in the preparations of gravity wave experiments to be conducted at other DSN stations in the future.

Otoshi, T. Y.

improving maser frequency stability

Hydrogen maser frequency standard is more stable by addition of parallel pyrex capillary tube array collimator. With collimator, maser line width has been made as narrow as 0.24 hertz representing fivefold improvement over maser without collimator. Fluorocarbon coating in tubes virtually eliminates energy loss in collimator.

Crampton, S. B.

Extraordinary frequency stabilization by resonant nonlinear mode coupling

Here, we show that a self-sustained oscillator with a frequency-selective element operating with two nonlinearly coupled modes can achieve a level of frequency stability well beyond that available using single-mode operation. The system of interest consists of a self-sustained oscillator based on a nonlinear primary mode that is coupled via an internal resonance to a passive secondary mode. Analysis of a generic model for this resonance with both additive and multiplicative noises reveals that the stability improvements accrue from two sources: (i) nonlinear frequency veering in the primary mode, a classical analogue to quantum-level repulsion, that eliminates amplitude-to-frequency noise conversion; and (ii) phase cleaning of the oscillator through an intrinsic phase constraint arising from synchronization of the modes. This latter effect can significantly reduce the effects of intrinsic frequency fluctuations of the primary mode, which are not accessible by any known strategy using single-mode operation. The theoretical predictions are supported by experimental measurements of a microelectromechanical systems-based oscillator that demonstrate a reduction in oscillator line width of several orders of magnitude. This approach offers a means of optimizing frequency stability in self-sustained oscillators, which has direct implications for applications in timekeeping and sensing.

36 MATERIALS SCIENCE

Thermal Noise Limit in Frequency Stabilization of Lasers with Rigid Cavities

We evaluated thermal noise (Brownian motion) in a rigid reference cavity used for frequency stabilization of lasers, based on the mechanical loss of cavity materials and the numerical analysis of the mirror-spacer mechanics with t.he direct application of the fluctuation dissipation theorem. This noise sets a fundamental limit for the frequency stability achieved with a rigid frequency- reference cavity of order 1 Hz/square root Hz(0.01 Hz/square root Hz) at 10 mHz (100 Hz) at room temperature. This level coincides with the world-highest level stabilization results.

Numata, Kenji