Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREQUENCY MODULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Switching circuit to improve the frequency modulation difference-intensity THz quantum cascade laser imaging

We demonstrate new switching circuit for difference-intensity THz quantum cascade laser (QCL) imaging by amplitude modulation and lock in detection. The switching circuit is designed to improve the frequency modulation so that it can stably lock the amplitude modulation of the QCL and the detector output. The combination of a voltage divider and a buffer in switching circuit to quickly switch the amplitude of the QCL biases of 15.8 V and 17.2 V is successfully to increase the frequency modulation up to ∼100 Hz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Formation of correlated states and optimization of nuclear reactions for low-energy particles at nonresonant low-frequency modulation of a potential well

A method for the formation of correlated coherent states of low-energy particles in a parabolic potential well owing to the full-scale low-frequency modulation ω(t) = ω{sub 0}sinΩt of the parameters of this well has been considered. It has been shown that such a modulation in the absence of a stochastic force acting on a particle results in the fast formation of correlated coherent states and in an increase in the correlation coefficient and transparency of the potential barrier to the limiting values vertical bar r(t) vertical bar {sub max} → 1 and D → 1. The presence of the stochastic force significantly affects the evolution of correlated coherent states, decreasing the rate of an increase in the correlation coefficient vertical bar r(t) vertical bar {sub max} (at Ω ≤ 10{sup −4}ω{sub 0}) and limiting it at the level vertical bar r(∞) vertical bar {sub max} < 1 (at Ω = (0.001–0.1)ω{sub 0}); vertical bar r(∞) vertical bar {sub max} increases with a decrease in the frequency of modulation and decreases with an increase in the intensity of the stochastic force. It has been shown that, at a realistic relation between the parameters, low-frequency modulation can ensure such vertical bar r vertical bar {sub max} value that the transparency of the potential barrier for low-energy particles increases by a factor of 10{sup 50}–10{sup 100} or larger. The mechanism of the formation of correlated coherent states for charged particles in a gas or a low-pressure plasma placed in a low-frequency magnetic field has been considered. We have determined the relation between the magnetic field strength and modulation frequency, as well as the relation between the temperature and density of the gas (plasma), at which the method under consideration can be used to optimize nuclear reactions at low energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of frequency modulation reflectometer for Korea Superconducting Tokamak Advanced Research tokamak

Frequency modulation reflectometer has been developed to measure the plasma density profile of the Korea Superconducting Tokamak Advanced Research tokamak. Three reflectometers are operating in extraordinary polarization mode in the frequency range of Q band (33.6–54 GHz), V band (48–72 GHz), and W band (72–108 GHz) to measure the density up to 7 × 10{sup 19} m{sup −3} when the toroidal magnetic field is 2 T on axis. The antenna is installed inside of the vacuum vessel. A new vacuum window is developed by using 50 μm thick mica film and 0.1 mm thick gold gasket. The filter bank of low pass filter, notch filter, and Faraday isolator is used to reject the electron cyclotron heating high power at attenuation of 60 dB. The full frequency band is swept in 20 μs. The mixer output is directly digitized with sampling rate of 100 MSamples/s. The phase is obtained by using wavelet transform. The whole hardware and software system is described in detail and the measured density profile is presented as a result.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cascade amplification of self-similar frequency-modulated pulses in normal group velocity dispersion active fibres

This paper examines the possibility of efficient amplification of self-similar frequency-modulated wave packets in longitudinally inhomogeneous active fibres. We analyse the dynamics of parabolic pulses with a constant frequency modulation rate and derive algorithms for optimising the group velocity dispersion profile in order to ensure self-similar propagation of such pulses. We demonstrate that the use of a cascade scheme can ensure efficient amplification of individual subpicosecond pulses of this type. (optical fibres, lasers and amplifiers. properties and applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bimodal atomic force microscopy driving the higher eigenmode in frequency-modulation mode: Implementation, advantages, disadvantages and comparison to the open-loop case

We present an overview of the bimodal amplitude–frequency-modulation (AM-FM) imaging mode of atomic force microscopy (AFM), whereby the fundamental eigenmode is driven by using the amplitude-modulation technique (AM-AFM) while a higher eigenmode is driven by using either the constant-excitation or the constant-amplitude variant of the frequency-modulation (FM-AFM) technique. We also offer a comparison to the original bimodal AFM method, in which the higher eigenmode is driven with constant frequency and constant excitation amplitude. General as well as particular characteristics of the different driving schemes are highlighted from theoretical and experimental points of view, revealing the advantages and disadvantages of each. This study provides information and guidelines that can be useful in selecting the most appropriate operation mode to characterize different samples in the most efficient and reliable way.

42 ENGINEERING↗

Improved accuracy and robustness of electron density profiles from JET’s X-mode frequency-modulated continuous-wave reflectometers

JET’s frequency-modulated continuous wave (FMCW) reflectometers have been operating well with the current design since 2005, and density profiles have been automatically calculated intershot since then. However, the calculated profiles had long suffered from several shortcomings: poor agreement with other diagnostics, sometimes inappropriately moving radially by several centimeters, elevated levels of radial jitter, and persistent wriggles (strong unphysical oscillations). Here, in this research, several techniques are applied to the reflectometry data analysis, and the shortcomings are significantly improved. Starting with improving the equilibrium reconstruction that estimates the background magnetic field, adding a ripple correction in the reconstructed magnetic field profile, and adding new inner-wall reflection positions estimated through ray-tracing, these changes not only improve the agreement of reconstructed profiles to other diagnostics but also solve density profile wriggles that were present during band transitions. Other smaller but also persistent wriggles were also suppressed by applying a localized correction to the measured beat frequency where persistent oscillations are present. Finally, the burst analysis method, as introduced by Varela et al., has been implemented to extract the beat frequency from stacked spectrograms. Due to the strong suppression of spurious reflections, the radial jitter that sometimes would span several centimeters has been strongly reduced. The stacking of spectrograms has also been shown to be very useful for stacking recurring events, like small gas puff modulations, and extracting transport coefficients that would otherwise be below the noise level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techniques for charging and/or discharging a battery using frequency modulation

Described herein are techniques that increase the charging and/or discharging rate of a rechargeable battery, at least in part, by using frequency modulated (FM) signals having a frequency in the megahertz (MHz) frequency range. In some embodiments, the MHz frequency range may include any frequency between 0.1 MHz and 1 gigahertz (GHz). In some embodiments, a battery charger described herein may be configured to generate and transmit, to a battery, an FM signal modulated over a frequency range during a period of time, the FM signal having a frequency of at least 0.5 MHz during at least a first portion of the period of time. In some embodiments, a method described herein includes transmitting an FM signal modulated over a frequency range during a period of time and having a frequency of at least 0.5 MHz during at least a first portion of the period of time to a battery.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local impedance measurement of an electrode/single-pentacene-grain interface by frequency-modulation scanning impedance microscopy

The device performances of organic thin film transistors are often limited by the metal–organic interface because of the disordered molecular layers at the interface and the energy barriers against the carrier injection. It is important to study the local impedance at the interface without being affected by the interface morphology. We combined frequency modulation atomic force microscopy with scanning impedance microscopy (SIM) to sensitively measure the ac responses of the interface to an ac voltage applied across the interface and the dc potential drop at the interface. By using the frequency-modulation SIM (FM-SIM) technique, we characterized the interface impedance of a Pt electrode and a single pentacene grain as a parallel circuit of a contact resistance and a capacitance. We found that the reduction of the contact resistance was caused by the reduction of the energy level mismatch at the interface by the FM-SIM measurements, demonstrating the usefulness of the FM-SIM technique for investigation of the local interface impedance without being affected by its morphology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of electron-cyclotron resonance plasma heating conditions on the low-frequency modulation of the gyrotron power at the L-2M stellarator

Low-frequency modulation of the gyrotron power at the L-2M stellarator was studied at different modes of plasma confinement. The plasma was heated at the second harmonic of the electron gyrofrequency. The effect of reflection of gyrotron radiation from the region of electron-cyclotron resonance plasma heating, as well as of backscattering of gyrotron radiation from fluctuations of the plasma density, on the modulation of the gyrotron power was investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wavelength domain spatial frequency modulation imaging: enabling fiber optic delivery and detection

Spatial frequency modulation imaging (SPIFI) provides a simple architecture for modulating an extended illumination source that is compatible with single pixel imaging. We demonstrate wavelength domain SPIFI (WD-SPIFI) by encoding time-varying spatial frequencies in the spectral domain that can produce enhanced resolution images, like its spatial domain counterpart, spatial domain (SD) SPIFI. However, contrary to SD-SPIFI, WD-SPIFI enables remote delivery by single mode fiber, which can be attractive for applications where free-space imaging is not practical. Finally, we demonstrate a cascaded system incorporating WD-SPIFI in-line with SD-SPIFI enabling single pixel 2D imaging without any beam or sample scanning.

47 OTHER INSTRUMENTATION↗

Determination of nanovibration amplitudes using frequency-modulated semiconductor laser autodyne

The method for measuring nanovibration amplitudes using the autodyne signal of a semiconductor laser at several laser radiation wavelengths is described. The theoretical description of the frequency-modulated autodyne signal under harmonic vibrations of the reflector is presented and the relations for its spectral components are derived using the expansions into the Fourier and Bessel series. The results of numerical modelling based on the proposed method for measuring the reflector nanovibration amplitudes are presented that make use of the low-frequency spectrum of the autodyne signal from the frequency-modulated laser autodyne and the solution of the appropriate inverse problem. The experimental setup is described; the results of the measurements are presented for the nanovibration amplitudes and the autodyne signal spectra under the reflector nanovibrations. (laser applications and other topics in quantum electronics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accurate formula for dissipative interaction in frequency modulation atomic force microscopy

Much interest has recently focused on the viscosity of nano-confined liquids. Frequency modulation atomic force microscopy (FM-AFM) is a powerful technique that can detect variations in the conservative and dissipative forces between a nanometer-scale tip and a sample surface. We now present an accurate formula to convert the dissipation power of the cantilever measured during the experiment to damping of the tip-sample system. We demonstrated the conversion of the dissipation power versus tip-sample separation curve measured using a colloidal probe cantilever on a mica surface in water to the damping curve, which showed a good agreement with the theoretical curve. Moreover, we obtained the damping curve from the dissipation power curve measured on the hydration layers on the mica surface using a nanometer-scale tip, demonstrating that the formula allows us to quantitatively measure the viscosity of a nano-confined liquid using FM-AFM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integration of fixed-frequency and FM-CW (frequency-modulated continuous-wave) reflectometers for coincident turbulence measurements on LTX- β (Lithium Tokamak eXperiment- β )

The fixed-frequency and frequency-modulated continuous-wave (FM-CW) reflectometers on LTX-β (Lithium Tokamak eXperiment-β) have been configured to use the same transmission lines and antenna arrays for coincident views of the core and edge plasma. The fixed-frequency channels (13.1–20.5 and 20–40 GHz, tunable between discharges) provide time-resolved measurements of density fluctuations, while the FM-CW channels (13.1–20.2 and 19.5–33.5 GHz) measure the density profile and fluctuations, with high spatial resolution and a sampling rate determined by the frequency sweep interval (5 μs). Data from both reflectometers are synchronously acquired to simultaneously leverage the wide bandwidth and high spatial resolution of the respective systems. Experiments showed that mutual crosstalk interference is momentary and does not diminish the capability of either system. Spectral analysis indicated broad power spectra (several hundreds of kHz) and suggests that the signals from the FM-CW system are consistent with under-sampled fixed-frequency signals. Radial correlations were explored using data from the two reflectometers, as well as from the FM-CW system alone. The core channels showed high levels of agreement between these two comparisons, suggesting that the data from the reflectometers are interchangeable for statistical estimates. For the edge channels, comparisons using data from the FM-CW reflectometer alone showed significant decorrelation due to time lag caused by the finite frequency up-sweep duration. Alternatively, this effect is eliminated when cross-correlating data from the different reflectometers. Finally, these results highlight the advantages of operating the fixed-frequency and FM-CW reflectometers in this manner, where the combined system can overcome the limitations of each separate system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation and Theory of Speckle Noise for an Annular Aperture Frequency-Modulation Differential-Absorption LIDAR (FM-DIAL) System

This paper presents theory of speckle noise for a frequency-modulation differential-absorption LIDAR system along with simulation results. These results show an unexpected relationship between the signal-to-noise ratio (SNR) of the speckle and the distance to the retro-reflector or target. In simulation, the use of an annular aperture in the system results in a higher SNR at midrange distances than at short or long distances. This peak in SNR occurs in the region where the laser’s Gaussian beam profile approximately fills the target. This was unexpected since it does not occur in the theory or simulations of the same system with a circular aperture. By including the autocorrelation of this annular aperture and expanding the complex correlation factor used in speckle models to include conditions not generally covered, a more complete theoretical model is derived for this system. Obscuration of the center of the beam at near distances is also a major factor in this relationship between SNR and distance. We conclude by comparing the resulting SNR as a function of distance from this expanded theoretical model to the simulations of the system over a double-pass horizontal range of 10 meters to 10 km at a wavelength of 1.28 micrometers

47 OTHER INSTRUMENTATION↗

Kinetic Study of the OH + Ethylene Reaction using Frequency Modulated Laser Absorption Spectroscopy

The pressure dependence of the OH + C 2 H 4 addition reaction has been investigated using frequency modulated laser absorption spectroscopy to monitor OH kinetics. Bimolecular rate coefficients for the title reaction are reported in argon bath gas at room temperature and total pressures ranging from 2–361Torr. The pressure dependent rate coefficients measured here agree well with the majority of published kinetic studies under similar conditions. Previous high-level ab initio calculations have identified a pre-reaction complex on the OH + C 2 H 4 potential energy surface. In conclusion, the influence of this complex on the OH + C 2 H 4 kinetics has been investigated using one-dimensional master equation analyses of the current and previous experimental measurements

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical simulation of amplification of frequency-modulated radiation in a gas amplifier THL-100 laser system

Numerical simulation methods have been used to study the effect of frequency modulation of input laser radiation with a pulse duration of 250 ps on the gain characteristics in a gas XeF (C – A) amplifier of the hybrid THL-100 laser system at a pump energy of 270 – 400 J. Using the Wigner distribution function, local radiation spectra are calculated at various points of the input laser beam with positive and negative chirps. The effect of the pump energy of the amplifier on the energy, intensity, and duration of the output laser radiation pulses is investigated. It is shown that with an insignificant change in energy, the pulse duration of the output radiation turns out to be longer with a negative chirp of the input radiation. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Autopilot for frequency-modulation atomic force microscopy

One of the most challenging aspects of operating an atomic force microscope (AFM) is finding optimal feedback parameters. This statement applies particularly to frequency-modulation AFM (FM-AFM), which utilizes three feedback loops to control the cantilever excitation amplitude, cantilever excitation frequency, and z-piezo extension. These loops are regulated by a set of feedback parameters, tuned by the user to optimize stability, sensitivity, and noise in the imaging process. Optimization of these parameters is difficult due to the coupling between the frequency and z-piezo feedback loops by the non-linear tip-sample interaction. Four proportional-integral (PI) parameters and two lock-in parameters regulating these loops require simultaneous optimization in the presence of a varying unknown tip-sample coupling. Presently, this optimization is done manually in a tedious process of trial and error. Here, we report on the development and implementation of an algorithm that computes the control parameters automatically. The algorithm reads the unperturbed cantilever resonance frequency, its quality factor, and the z-piezo driving signal power spectral density. It analyzes the poles and zeros of the total closed loop transfer function, extracts the unknown tip-sample transfer function, and finds four PI parameters and two lock-in parameters for the frequency and z-piezo control loops that optimize the bandwidth and step response of the total system. Implementation of the algorithm in a home-built AFM shows that the calculated parameters are consistently excellent and rarely require further tweaking by the user. The new algorithm saves the precious time of experienced users, facilitates utilization of FM-AFM by casual users, and removes the main hurdle on the way to fully automated FM-AFM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗