Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FOCUSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Space and velocity focusing in time-of-flight mass spectrometers

A focusing equation is developed describing the relationship between space and velocity focusing for all one-dimensional time-of-flight mass spectrometers with constant electric fields. As a result of this equation, first-order double time focusing in one dimension is impossible. The possibility of large improvements in the resolving power of the time-of-flight mass spectrometers is discussed on this basis. The focusing equation also leads to an expression for the minimum time resolution obtainable. This second equation is applied to the conventional Wiley and McLaren (1955) two-field time-of-flight mass spectrometer with and without time-lag focusing, and to the mirror instrument of Karataev et al. (1972).

Stein, R.↗

The effect of adiabatic focusing upon charged particle propagation in random magnetic fields

This paper describes the effects of strong adiabatic focusing in terms of eigenfunctions of an operator which incorporates both scattering by random fields and focusing by a spatially inhomogeneous guiding field. It is found that focused transport differs from rectilinear transport in the following ways: (1) the coherent velocity toward stronger fields is larger than that toward weaker fields; (2) coherent effects are more prominent relative to diffusive effects when focusing is present; and (3) initial anisotropies at injection have a minimal influence upon rectilinear transport but they have a pronounced effect on focused transport. These features explain certain well-known discrepancies between the diffusive picture and the observed profiles of solar particle events. In particular, they explain the so-called scatter-free propagation of kilovolt flare electrons.

Earl, J. A.↗

Criteria for the selection of focusing ultrasonic probes

The principles of operation employed in the focusing of a sound field are considered, taking into account the use of solid and liquid coupling media. The focusing limits for a given transducer are investigated. As a diffraction phenomenon, focusing is a function of the system dimensions, the frequency, and the sound velocity. The frequency and the material used for the lenses are in most cases determined in accordance with considerations regarding sound propagation. Changes in the focus are therefore effected mainly by the selection of transducer and lens dimensions. The functions of the focusing factor for a normal immersion probe and a direct contact angle probe are represented in graphs. The deviation of the appropriate parametric values for an ultrasonic probe is illustrated with the aid of examples.

Schlengermann, U.↗

Quantitative results from the focusing schlieren technique

An iterative theoretical approach to obtain quantitative density data from the focusing schlieren technique is proposed. The approach is based on an approximate modeling of the focusing action in a focusing schlieren system, and an estimation of an appropriate focal plane thickness. The theoretical approach is incorporated in a computer program, and results obtained from a supersonic wind tunnel experiment evaluated by comparison with CFD data. The density distributions compared favorably with CFD predictions. However, improvements to the system are required in order to reduce noise in the data, to improve specifications of a depth of focus, and to refine the modeling of the focusing action.

Cook, S. P.↗

Three-Dimensional Simulations of Electron Beams Focused by Periodic Permanent Magnets

A fully three-dimensional (3D) model of an electron beam focused by a periodic permanent magnet (PPM) stack has been developed. First, the simulation code MAFIA was used to model a PPM stack using the magnetostatic solver. The exact geometry of the magnetic focusing structure was modeled; thus, no approximations were made regarding the off-axis fields. The fields from the static solver were loaded into the 3D particle-in-cell (PIC) solver of MAFIA where fully 3D behavior of the beam was simulated in the magnetic focusing field. The PIC solver computes the time-integration of electromagnetic fields simultaneously with the time integration of the equations of motion of charged particles that move under the influence of those fields. Fields caused by those moving charges are also taken into account; thus, effects like space charge and magnetic forces between particles are fully simulated. The electron beam is simulated by a number of macro-particles. These macro-particles represent a given charge Q amounting to that of several million electrons in order to conserve computational time and memory. Particle motion is unrestricted, so particle trajectories can cross paths and move in three dimensions under the influence of 3D electric and magnetic fields. Correspondingly, there is no limit on the initial current density distribution of the electron beam, nor its density distribution at any time during the simulation. Simulation results including beam current density, percent ripple and percent transmission will be presented, and the effects current, magnetic focusing strength and thermal velocities have on beam behavior will be demonstrated using 3D movies showing the evolution of beam characteristics in time and space. Unlike typical beam optics models, this 3D model allows simulation of asymmetric designs such as non- circularly symmetric electrostatic or magnetic focusing as well as the inclusion of input/output couplers.

Kory, Carol L.↗

Modeling a Miniaturized Scanning Electron Microscope Focusing Column - Lessons Learned in Electron Optics Simulation

This presentation discusses work done to assess the design of a focusing column in a miniaturized Scanning Electron Microscope (SEM) developed at the NASA Marshall Space Flight Center (MSFC) for use in-situ on the Moon-in particular for mineralogical analysis. The MSFC beam column design uses purely electrostatic fields for focusing, because of the severe constraints on mass and electrical power consumption imposed by the goals of lunar exploration and of spaceflight in general. The resolution of an SEM ultimately depends on the size of the focused spot of the scanning beam probe, for which the stated goal here is a diameter of 10 nanometers. Optical aberrations are the main challenge to this performance goal, because they blur the ideal geometrical optical image of the electron source, effectively widening the ideal spot size of the beam probe. In the present work the optical aberrations of the mini SEM focusing column were assessed using direct tracing of non-paraxial rays, as opposed to mathematical estimates of aberrations based on paraxial ray-traces. The geometrical ray-tracing employed here is completely analogous to ray-tracing as conventionally understood in the realm of photon optics, with the major difference being that in electron optics the lens is simply a smoothly varying electric field in vacuum, formed by precisely machined electrodes. Ray-tracing in this context, therefore, relies upon a model of the electrostatic field inside the focusing column to provide the mathematical description of the "lens" being traced. This work relied fundamentally on the boundary element method (BEM) for this electric field model. In carrying out this research the authors discovered that higher accuracy in the field model was essential if aberrations were to be reliably assessed using direct ray-tracing. This led to some work in testing alternative techniques for modeling the electrostatic field. Ultimately, the necessary accuracy was attained using a BEM/Fourier series hybrid approach. The presentation will give background remarks about the MSFC mini Lunar SEM concept and electron optics modeling, followed by a description of the alternate field modeling techniques that were tried, along with their incorporation into a ray-trace simulation. Next, the validation of this simulation against commercially available software will be discussed using an example lens as a test case. Then, the efficacy of aberration assessment using direct ray-tracing will be demonstrated, using this same validation case. The discussion will include practical error checks of the field solution. Finally, the ray-trace assessment of the MSFC mini Lunar SEM concept will be shown and discussed. The authors believe this presentation will be of general interest to practitioners of modeling and simulation, as well as those with a general optics background. Because electron optics and photon optics share many basic concepts (e.g., lenses, images, aberrations, etc.), the appeal of this presentation need not be restricted to just those interested in charged particle optics.

Modeling Miniaturizing Scanning↗

Methods for Reducing Singly Reflected Rays on the Wolter-I Focusing Figures of the FOXSI Rocket Experiment

In high energy solar astrophysics, imaging hard X-rays by direct focusing offers higher dynamic range and greater sensitivity compared to past techniques that used indirect imaging. The Focusing Optics X-ray Solar Imager (FOXSI) is a sounding rocket payload which uses seven sets of nested Wolter-I figured mirrors that, together with seven high-sensitivity semiconductor detectors, observes the Sun in hard X-rays by direct focusing. The FOXSI rocket has successfully flown twice and is funded to fly a third time in Summer 2018. The Wolter-I geometry consists of two consecutive mirrors, one paraboloid, and one hyperboloid, that reflect photons at grazing angles. Correctly focused X-rays reflect twice, once per mirror segment. For extended sources, like the Sun, off-axis photons at certain incident angles can reflect on only one mirror and still reach the focal plane, generating a pattern of single-bounce photons that can limit the sensitivity of the observation of faint focused X-rays. Understanding and cutting down the singly reflected rays on the FOXSI optics will maximize the instrument's sensitivity of the faintest solar sources for future flights. We present an analysis of the FOXSI singly reflected rays based on ray-tracing simulations, as well as the effectiveness of different physical strategies to reduce them.

FOXSI Rocket Experiment↗

A study of transient stimulated Raman scattering and self-focusing in the picosecond time regime

Two third order processes, stimulated Raman scattering and self-focusing, with picosecond pulses are studied. In the case of transient stimulated scattering, the gain is reduced from the steady state value, and qualitatively new features, such as shortening and delay of the Stokes pulse relative to the laser pulse, appear. These predictions are extended to realistic laser pulses, and experiments confirm all of the theoretical predictions. The self-focusing and frequency broadening of picosecond pulses is studied in the absence of stimulated Raman scattering in several materials with large orientational Kerr constants. Measurements of the relaxation time indicate that the orientational Kerr effect is important in the self-focusing of picosecond pulses. Self-focused filaments are observed to propagate with constant diameters over a distance greater than 10 cm, but disappear before the end of a 20 cm cell. The filaments radiate light continuously along their path and the spectrum of the light shows that the frequency content extends symmetrically for several hundred wave numbers on either side of the laser frequency.

Reintjes, J. F.↗

Prediction of sonic boom at a focus

The behavior of sonic boom at a focus has been reviewed for the purpose of extending present sonic boom computational methods to include focal zones. The geometry of a focal zone - whether a smooth caustic, a cusped caustic, or a perfect focus to a point - determines the character of focused signatures. The seeming contradiction of various experimental data can be resolved by noting these differences. A ray acoustic analysis has been developed for quantitative determination of caustic geometry. The only reliable theory presently available for signatures at a focus is for a smooth caustic. There has been some controversy between theoretical and experimental values of a constant in the scaling law for this case. It has been found that this discrepancy can be resolved by accounting for the finite thickness of real sonic boom shock waves. These findings have been incorporated into an existing sonic boom computer program.

Plotkin, K. J.↗

The effect of adiabatic focusing upon charged-particle propagation in random magnetic fields

The charged particles considered are scattered by random fields while they propagate along the diverging lines of force of a spatially inhomogeneous guiding field. Their longitudinal transport is described in terms of the eigenfunctions of a Sturm-Liouville operator which incorporates the effect of adiabatic focusing along with that of scattering. The relaxation times and characteristic velocities which appear in this matrix formulation of the transport problem are graphed and tabulated. Explicit formulas which describe the particle-density profile that results from a localized impulsive injection are derived for two different regimes. In the first regime, where focusing is relatively weak, a diffusive mode of propagation is dominant, but coherent modes are also present, and they become prominent as the intensity of focusing increases. In the second regime, where focusing is strong and where diffusion does not occur, the propagation is purely coherent. The existence of this supercoherent mode of particle transport opens up many possibilities for the interpretation of astrophysical phenomena.

Earl, J. A.↗

Scanning and focusing mechanisms of METEOSAT radiometer

The scanning and focusing mechanisms settled onboard the METEOSAT Radiometer are described. A large camera which will take line by line pictures of the earth from a geostationary satellite in the same manner as a TV picture using both the spin of the spacecraft and the tilt of a telescope is included. The scanning mechanism provides the + or - 9 degrees tilt angle of the telescope through 2,500 elementary steps of 1.256 0.0001 radian. As the radiometer image quality is closely dependent on the characteristics of the scanning law, the mechanism is required to fulfill functional performances specifications particularly severe in terms of linearity of the scan curve, accuracy of each step as well as repeatability of the short-term scanning. The focusing mechanism allows + or - 12 millimeters shift of the telescope focus by step increments of 0.140 mm. The focus adjustment is achieved by moving a dihedral reflector according to a pure straight-line motion. The main requirements of each mechanism are summarized and their design and performances are described in detail.

Jouan, J.↗

Investigation of a staged plasma-focus apparatus

A new staged plasma-focus geometry combining two Mather-type plasma-focus guns was constructed, and the current-sheet dynamics were investigated. The production of simultaneous pairs of plasma foci was achieved. The intensities of X-ray and fusion-neutron emission were measured and found to agree with the scaling law for a plasma focus. Advantages of this new geometry include the possibility of using plasma-focus type pinches in multiple arrays at power levels beyond the validity regime of the current scaling law for a single gun.

Lee, J. H.↗

Solar thermal power systems point-focusing thermal and electric applications projects. Volume 1: Executive summary

The activities of the Point-Focusing Thermal and Electric Applications (PETEA) project for the fiscal year 1979 are summarized. The main thrust of the PFTEA Project, the small community solar thermal power experiment, was completed. Concept definition studies included a small central receiver approach, a point-focusing distributed receiver system with central power generation, and a point-focusing distributed receiver concept with distributed power generation. The first experiment in the Isolated Application Series was initiated. Planning for the third engineering experiment series, which addresses the industrial market sector, was also initiated. In addition to the experiment-related activities, several contracts to industry were let and studies were conducted to explore the market potential for point-focusing distributed receiver (PFDR) systems. System analysis studies were completed that looked at PFDR technology relative to other small power system technology candidates for the utility market sector.

Marriott, A.↗

A new method for focusing and imaging X-rays and gamma-rays with diffraction crystals

Bent diffraction crystals in which the intercrystalline-plane spacing is varied as a function of position in the crystal are used to focus monochromatic radiation from a point source or parallel beam down to a point image. Conversely, radiation from a point source can be focused into an outgoing parallel beam. The Bragg angle for diffraction of monochromatic radiation will now vary as a function of position in the crystal and this new degree of freedom is used to obtain focusing and imaging of the diffracted beam. This approach to focusing and imaging is applied to the design of a large-area, high resolution X-ray telescope that is also a high resolution monochromator with the unique feature that the width of the energy increment that is diffracted can be controlled and varied during the operation of the instrument. The field can be scanned with a wide energy increment and then switched to a narrow energy increment for the high resolution work. Both transmission and reflection type diffraction crystals can be used.

Smither, R. K.↗

Sharp-Focus Composite Microscope Imaging by Computer

Enhanced depth of focus aids medical analysis. Computer image-processing system synthesizes sharply-focused composite picture from series of photomicrographs of same object taken at different depths. Computer rejects blured parts of each photomicrograph. Remaining in focus portions form focused composite. System used to study alveolar lung tissue and has applications in medicine and physical sciences.

Wall, R. J.↗

Electron-Focus Adjustment for Photo-Optical Imagers

Internal electron focus made independent of optical focus. Procedure enables fine tuning of internal electron-focusing system of photo-optical imager, without complication by imperfections of associated external optics. Applicable to imager in which electrons emitted from photocathode in optical focal plane, then electrostatically and/or magnetically focused to replica of image in second focal plane containing photodiodes, phototransistorss, charge-coupled devices, multiple-anode outputs, or other detectors.

Fowler, Walter B.↗

Transformational derivation of programs using the Focus system

A program derivation support system called Focus is being constructed. It will formally derive programs using the paradigm of program transformation. The following issues are discussed: (1) the integration of validation and program derivation activities in the Focus system; (2) its tree-based user interface; (3) the control of search spaces in program derivation; and (4) the structure and organization of program derivation records. The inference procedures of the system are based on the integration of functional and logic programming principles. This brings about a synthesis of paradigms that were heretofore considered far apart, such as logical and executable specifications and constructive and transformational approaches to program derivation. A great emphasis has been placed, in the design of Focus, on achieving small search spaces during program derivation. The program manipulation operations such as expansion, simplification and rewriting were designed with this objective. The role of operations that are expensive in search spaces, such as folding, has been reduced. Program derivations are documented in Focus in a way that the high level descriptions of derivations are expressed only using program level information. All the meta-level information, together with dependencies between derivations of program components, is automatically recorded by the system at a lower level of description for its own use in replay.

Reddy, Uday S.↗

Inverse photoelectron spectrometer with magnetically focused electron gun

An inverse photoelectron spectrometer is described which is based on the design of a magnetically focused low energy electron gun. The magnetic lens extends its field over a relatively large segment of the electron trajectory, which could provide a better focusing effect on a high-current-density low-velocity electron beam, providing the magnetic field in the vicinity of the target is reduced sufficiently to preserve the collinearity of the beam. In order to prove the concept, ray tracing is conducted using the Herrmannsfeldt program for solving electron trajectories in electrostatic and magnetostatic focusing systems. The program allows the calculation of the angles of the electron trajectories with the z axis, at the target location. The results of the ray-tracing procedure conducted for this gun are discussed. Some of the advantages of the magnetic focusing are also discussed.

Krainsky, Isay L.↗