Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUIDICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fluidic impedance platform for in-situ detection and quantification of PFAS in groundwater

Materials for binding per- and polyfluoroalkyl substances (PFAS) are disclosed. A fluidic device comprising the materials for detection and quantification of PFAS in a sample is disclosed. The fluidic device may be configured for multiplexed analyses. Also disclosed are methods for sorbing and remediating PFAS in a sample. The sample may be groundwater containing, or suspected of containing, one or more PFAS.

Chatterjee, Sayandev↗

New leak assembly based on fluidic nanochannels

Fluidic nanochannels with a characteristic dimension of ∼280 nm were fabricated and designed as a leak assembly, where the nanochannels were formed on silicon wafers and enclosed with Pyrex{sup ®} glass. The geometric dimensions were characterized by scanning electron microscopy, and the gas flow conductance of He and other heavy gases (N{sub 2}, O{sub 2}, and Ar) was measured, and its uncertainty estimated, by the difference method. The results indicated that the measured flow conductance values were 45% less than the calculated flow conductance values. For helium, molecular flow was shown to occur at pressures ranging from vacuum to atmospheric pressure. As a consequence of the well-defined geometry, the prediction of flow conductance could be achieved for various gas species.

42 ENGINEERING↗

scifi-ATAC-seq: massive-scale single-cell chromatin accessibility sequencing using combinatorial fluidic indexing

Abstract Single-cell ATAC-seq has emerged as a powerful approach for revealing candidate cis-regulatory elements genome-wide at cell-type resolution. However, current single-cell methods suffer from limited throughput and high costs. Here, we present a novel technique called scifi-ATAC-seq, single-cell combinatorial fluidic indexing ATAC-sequencing, which combines a barcoded Tn5 pre-indexing step with droplet-based single-cell ATAC-seq using the 10X Genomics platform. With scifi-ATAC-seq, up to 200,000 nuclei across multiple samples can be indexed in a single emulsion reaction, representing an approximately 20-fold increase in throughput compared to the standard 10X Genomics workflow.

59 BASIC BIOLOGICAL SCIENCES↗

Fluidic Processing of High-Performance ZIF-8 Membranes on Polymeric Hollow Fibers: Mechanistic Insights and Microstructure Control

Recently, a methodology for fabricating polycrystalline metal-organic framework (MOF) membranes has been introduced – referred to as interfacial microfluidic membrane processing – which allows parallelizable fabrication of MOF membranes inside polymeric hollow fibers of microscopic diameter. Such hollow fiber membranes, when bundled together into modules, are an attractive way to scale molecular sieving membranes. The understanding and engineering of fluidic processing techniques for MOF membrane fabrication are in their infancy. Here in this work, a detailed mechanistic understanding of MOF (ZIF-8) membrane growth under microfluidic conditions in polyamide-imide hollow fibers is reported, without any intermediate steps (such as seeding or surface modification) or post-synthesis treatments. A key finding is that interfacial membrane formation in the hollow fiber occurs via an initial formation of two distinct layers and the subsequent rearrangement into a single layer. This understanding is used to show how nonisothermal processing allows fabrication of thinner (5 μm) ZIF-8 films for higher throughput, and furthermore how engineering the polymeric hollow fiber support microstructure allows control of defects in the ZIF-8 membranes. Finally, the performance of these engineered ZIF-8 membranes is then characterized, which have H 2 /C 3 H 8 and C 3 H 6 /C 3 H 8 mixture separation factors as high as 2018 and 65, respectively, and C 3 H 6 permeances as high as 66 GPU.

36 MATERIALS SCIENCE↗

Anion exchange and extraction chromatography tandem column isolation of zirconium-89 ( 89 Zr) from cyclotron bombarded targets using an automated fluidic platform

The long-lived positron emitter 89 Zr is a highly promising nuclide employed in diagnostic Positron Emission Tomography (PET) imaging. Methods of radiochemical processing to obtain 89 Zr for clinical use are traditionally performed with a single hydroxamate resin column. In this work, we present a tandem column purification method for the preparation of high-purity 89 Zr from cyclotron bombarded Y metal foils. The primary column is a macroporous, strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary microcolumn, with an internal volume of 33 µL, is packed with an extraction chromatography resin (ExCR) loaded with HDEHP. A condition of “inverted selectivity” is presented, wherein the 89 Zr elution from the primary column is synonymous with the load condition on the secondary column. The ability to transfer 89 Zr from one column to the next allows two sequential column clean-up methods to be performed prior to the final elution of the 89 Zr product. This approach assures delivery of very high purity 89 Zr . The tandem column purification process has been implemented into a prototype automated fluidic system. Optimization of the method is presented, followed by evaluation of the process using seven cyclotron bombarded Y metal foil targets. Once optimized, we found that 93.7±2.3% of the 89 Zr present in the foils was recovered in the secondary column elution fraction (0.8 M oxalic acid). Radiochromatograms of the product elution peaks enabled determination of full width at half-maximum (FWHM) and 89 Zr collection yields as a function of volume. Because of the small size of the secondary microcolumn, a 89 Zr product volume of ~0.28 mL is reported, which provides a substantially increased nuclide concentration over traditional methods. Finally, we evaluated the transchelation of the resulting 89 Zr oxalate product to deferoxamine mesylate (DFOM) salt. We observed effective specific activities (ESA) and bindable metals concentrations ([M B ]) that exceed those reported by the traditional single hydroxamate column method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fiber-Shaped Fluidic Nanogenerator with High Power Density for Self-Powered Integrated Electronics

Flow-based hydrovoltaic nanogenerators have attracted particular attention as efficient and facile miniature energy-harvesting devices. However, they deliver relatively low output power density and limited power conversion efficiency owing to inefficient charge separation and poor charge accumulation. Here, we report the fabrication of high-performance, fiber-shaped fluidic nanogenerators (FFNGs) that use MoS 2 -encapsulated C fibers. The FFNGs deliver stable output voltages of 540 mV and an ultrahigh power density of 10.8 W m -2 . With experiments and density functional theory calculations, improvements in output performance can be attributed to smaller energy requirements for Na + cation adsorption, increased charge separation, and diffusion layer formations on the near surface. Moreover, self-powered, integrated devices achieve a maximum total power conversion-storage efficiency of ~11% and stable output voltage up to 3.1 V, which is applicable for use in consumer electronics devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Harnessing liquid-in-liquid printing and micropatterned substrates to fabricate 3-dimensional all-liquid fluidic devices

Systems comprised of immiscible liquids held in non-equilibrium shapes by the interfacial assembly and jamming of nanoparticle-polymer surfactants have crucial potential to advance catalysis, chemical separations, energy storage and conversion. Spatially directing functionality within them and coupling processes in both phases remains a challenge. In this work, we exploit nanoclay-polymer surfactant assemblies at an oil-water interface to produce a semi-permeable membrane between the liquids, and from them all-liquid fluidic devices with bespoke properties. Flow channels are fabricated using micropatterned 2D substrates and liquid-in-liquid 3D printing. The anionic walls of the device can be functionalized with cationic small molecules, enzymes, and colloidal nanocrystal catalysts. Multi-step chemical transformations can be conducted within the channels under flow, as can selective mass transport across the liquid-liquid interface for in-line separations. These all-liquid systems become automated using pumps, detectors, and control systems, revealing a latent ability for chemical logic and learning.

36 MATERIALS SCIENCE↗

Probing flow-induced nanostructure of complex fluids in arbitrary 2D flows using a fluidic four-roll mill (FFoRM)

Abstract Engineering flow processes to direct the microscopic structure of soft materials represents a growing area of materials research. In situ small-angle neutron scattering under flow (flow-SANS) is an attractive probe of fluid microstructure under simulated processing conditions, but current capabilities require many different sample environments to fully interrogate the deformations a fluid experiences in a realistic processing flow. Inspired by recent advances in microfluidics, we present a fluidic four-roll mill (FFoRM) capable of producing tunable 2D flow fields for in situ SANS measurements, that is intended to allow characterization of complex fluid nanostructure under arbitrary complex flows within a single sample environment. Computational fluid dynamics simulations are used to design a FFoRM that produces spatially homogeneous and sufficiently strong deformation fields. Particle tracking velocimetry experiments are then used to characterize the flows produced in the FFoRM for several classes of non-Newtonian fluids. Finally, a putative FFoRM-SANS workflow is demonstrated and validated through the characterization of flow-induced orientation in a semi-dilute cellulose nanocrystal dispersion under a range of 2D deformations. These novel experiments confirm that, for steady state straining flows at moderate strain rates, the nanocrystals orient along the principal strain-rate axis, in agreement with theories for rigid, rod-like Brownian particles in a homogeneous flow.

36 MATERIALS SCIENCE↗

Vortex fluidic regulated phospholipid equilibria involving liposomes down to sub-micelle size assemblies

Conventional channel-based microfluidic platforms have gained prominence in controlling the bottom-up formation of phospholipid based nanostructures including liposomes. However, there are challenges in the production of liposomes from rapidly scalable processes. These have been overcome using a vortex fluidic device (VFD), which is a thin film microfluidic platform rather than channel-based, affording ~110 nm diameter liposomes. The high yielding and high throughput continuous flow process has a 45° tilted rapidly rotating glass tube with an inner hydrophobic surface. Processing is also possible in the confined mode of operation which is effective for labelling pre-VFD-prepared liposomes with fluorophore tags for subsequent mechanistic studies on the fate of liposomes under shear stress in the VFD. In situ small-angle neutron scattering (SANS) established the co-existence of liposomes ~110 nm with small rafts, micelles, distorted micelles, or sub-micelle size assemblies of phospholipid, for increasing rotation speeds. The equilibria between these smaller entities and ~110 nm liposomes for a specific rotational speed of the tube is consistent with the spatial arrangement and dimensionality of topological fluid flow regimes in the VFD. The prevalence for the formation of ~110 nm diameter liposomes establishes that this is typically the most stable structure from the bottom-up self-assembly of the phospholipid and is in accord with dimensions of exosomes.

60 APPLIED LIFE SCIENCES↗

Opto-mechano-fluidic viscometer

The recent development of opto-mechano-fluidic resonators has provided—by harnessing photon radiation pressure—a microfluidics platform for the optical sensing of fluid density and bulk modulus. Here, we show that fluid viscosity can also be determined through optomechanical measurement of the vibrational noise spectrum of the resonator mechanical modes. A linear relationship between the spectral linewidth and root-viscosity is predicted and experimentally verified in the low viscosity regime. Our result is a step towards multi-frequency measurement of viscoelasticity of arbitrary fluids, without sample contamination, using highly sensitive optomechanics techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetohydrodynamic actuation of droplets for millimetric planar fluidic systems

In this work, a magnetohydrodynamic method is proposed for the actuation of droplets in small-scale planar fluidic systems, providing an alternative to commonly used methods such as electrowetting-on-dielectric. Elementary droplet-based operations, including transport, merging, and mixing, are demonstrated. The forces acting on millimetric droplets are carefully investigated, with a primary focus on the magnetic actuation force and on the unbalanced capillary forces that arise due to hysteresis. A super-hydrophobic channel is 3D printed to guide the droplets, with thin wires installed as contact electrodes and permanent magnets providing a static magnetic field. It is shown that droplet motion is enhanced by increasing the droplet size and minimizing the electrode contact surface. The effects of channel geometry on threshold voltage and minimum moveable droplet volume are characterized. Finally, the presence of electrolysis is investigated and mitigating strategies are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Power Fluidic Pumping Technology for Molten Salt Reactor Applications

Power Fluidics™ (PF) is a NuVision Engineering proprietary technology which uses gases to control the flow of other fluids in industrial applications. This unique technology has several advantages over traditional centrifugal pumps. Molten salt nuclear reactors and associated systems have unique fluid handling demands. This report explores the applicability of PF to molten salt systems. Several potential applications are identified, necessary modifications of existing PF technology for salt service are discussed, and a path for development and demonstration is proposed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Module-Fluidics: Building Blocks for Spatio-Temporal Microenvironment Control

Generating the desired solute concentration signal in micro-environments is vital to many applications ranging from micromixing to analyzing cellular response to a dynamic microenvironment. We propose a new modular design to generate targeted temporally varying concentration signals in microfluidic systems while minimizing perturbations to the flow field. The modularized design, here referred to as module-fluidics, similar in principle to interlocking toy bricks, is constructed from a combination of two building blocks and allows one to achieve versatility and flexibility in dynamically controlling input concentration. The building blocks are an oscillator and an integrator, and their combination enables the creation of controlled and complex concentration signals, with different user-defined time-scales. We show two basic connection patterns, in-series and in-parallel, to test the generation, integration, sampling and superposition of temporally-varying signals. All such signals can be fully characterized by analytic functions, in analogy with electric circuits, and allow one to perform design and optimization before fabrication. Such modularization offers a versatile and promising platform that allows one to create highly customizable time-dependent concentration inputs which can be targeted to the specific application of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sub-micrometer fluidic channel for measuring photon emitting entities

A nanofluidic channel fabricated in fused silica with an approximately 500 nm square cross section was used to isolate, detect and identify individual quantum dot conjugates. The channel enables the rapid detection of every fluorescent entity in solution. A laser of selected wavelength was used to excite multiple species of quantum dots and organic molecules, and the emission spectra were resolved without significant signal rejection. Quantum dots were then conjugated with organic molecules and detected to demonstrate efficient multicolor detection. PCH was used to analyze coincident detection and to characterize the degree of binding. The use of a small fluidic channel to detect quantum dots as fluorescent labels was shown to be an efficient technique for multiplexed single molecule studies. Detection of single molecule binding events has a variety of applications including high throughput immunoassays.

36 MATERIALS SCIENCE↗

Fluidic actuator system and method

An actuator assembly that includes an angled bottom plate having an opposing first side face and second side face; a first set of one or more inflatable actuators engaging the first side face of the angled bottom plate; and a second set of one or more inflatable actuators engaging the second side face of the angled bottom plate. The first and second sets of inflatable actuators are configured to be separately fluidically inflated.

Madrone, Leila Marcia↗

Fluidic carbon nanotube device

Fluidic and electrofluidic devices comprising carbon nanotubes and methods of making and using the same are provided. The carbon nanotubes may be densely bundled to span an aperture in a substrate. A polymeric coating over the substrate may contain reservoir(s) etched therein, the reservoir(s) in fluid connectivity with the carbon nanotubes. X-rays may be directed through the aperture and fluid-filled carbon nanotubes with x-ray analysis providing data on fluid structure and dynamics inside the carbon nanotubes.

Meshot, Eric R.↗

Out-of-plane curved fluidic oscillator

Various implementations include, an out-of-plane feedback-type fluidic oscillator. including a first portion, a second portion, a middle portion coupled between the first portion and the middle portion, and an axis of rotation. The middle portion includes a first side, a second side opposite and spaced apart from the first side, and a middle plane, an interaction chamber, a fluid supply inlet, an outlet nozzle, a first feedback a channel, and a second feedback channel. The first side is coupled to the first portion, and the second side is coupled to the second portion. The first side, the second side, and the middle plane extend circumferentially around the axis of rotation. The middle plane is disposed equally distanced from the first side and the second side. The fluid stream oscillates as it flows through the interaction chamber such that the fluid stream oscillates as the fluid stream exits the outlet nozzle.

Hossain, Mohammad Arif↗

Fluidic Flow Assisted Deterministic Folding of Van der Waals Materials

Origami offers a distinct approach for designing and engineering new material structures and properties. The folding and stacking of atomically thin van der Waals (vdW) materials, for example, can lead to intriguing new physical properties including bandgap tuning, Van Hove singularity, and superconductivity. On the other hand, achieving well-controlled folding of vdW materials with high spatial precision has been extremely challenging and difficult to scale toward large areas. In this paper, a deterministic technique is reported to fold vdW materials at a defined position and direction using microfluidic forces. Electron beam lithography (EBL) is utilized to define the folding area, which allows precise control of the folding geometry, direction, and position beyond 100 nm resolution. Using this technique, single-atomic-layer vdW materials or their heterostructures can be folded without the need for any external supporting layers in the final folded structure. In addition, arrays of patterns can be folded across a large area using this technique and electronic devices that can reconfigure device functionalities through folding are also demonstrated. Such scalable formation of folded vdW material structures with high precision can lead to the creation of new atomic-scale materials and superlattices as well as opening the door to realizing foldable and reconfigurable electronics.

2D materials↗