Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fluid property measurements study

Fluid properties of refrigerant-21 were investigated at temperatures from the freezing point to 423 Kelvin and at pressures to 1.38 x 10 to the 8th power N/sq m (20,000 psia). The fluid properties included were: density, vapor pressure, viscosity, specific heat, thermal conductivity, thermal expansion coefficient, freezing point and bulk modulus. Tables of smooth values are reported.

Devaney, W. E.↗

Fluid velocity measuring device

A fluid velocity measuring device is described which, when placed in a freestream fluid flow, causes vortices to be formed at a frequency proportional to the flow rate of the fluid. Sensors on the device generate electric signals with frequency proportional to the rate of vortex creation and with relative mean amplitudes indicative of fluid flow direction. Electric circuitry translates the electric signals into indications of fluid speed and direction.

Thomas, D. F., Jr.↗

A Wireless Fluid-Level Measurement Technique

This paper presents the application of a recently developed wireless measurement acquisition system to fluid-level measurement. This type of fluid-level measurement system alleviates many shortcomings of fluid-level measurement methods currently being used, including limited applicability of any one fluid-level sensor design. Measurement acquisition shortcomings include the necessity for power to be supplied to each sensor and for the measurement to be extracted from each sensor via a physical connection to the sensor. Another shortcoming is existing measurement systems require that a data channel and signal conditioning electronics be dedicated to each sensor. Use of wires results in other shortcomings such as logistics needed to add or replace sensors, weight, potential for electrical arcing and wire degradations. The fluid level sensor design is a simple passive inductor-capacitor circuit that is not subject to mechanical failure that is possible when float and lever-arm systems are used. Methods are presented for using the sensor in caustic, acidic or cryogenic fluids. Oscillating magnetic fields are used to power the sensor. Once electrically excited, the sensor produces a magnetic field response. The response frequency corresponds to the amount to fluid within the capacitor s electric field. The sensor design can be modified for measuring the level of any fluid or fluent substance that can be stored in a non-conductive reservoir. The interrogation method for discerning changes in the sensor response frequency is also presented.

Woodard, Stanley E.↗

ASTP fluid transfer measurement experiment

The ASTP fluid transfer measurement experiment flight system design concept was verified by the demonstration and test of a breadboard model. In addition to the breadboard effort, a conceptual design of the corresponding flight system was generated and a full scale mockup fabricated. A preliminary CEI specification for the flight system was also prepared.

Fogal, G. L.↗

Measurement of fluid velocity fields using digital correlation techniques

A new aperiodic recording technique for measuring fluid velocity fields by digital correlation is introduced which uses a low-powered He-Ne laser, a desktop computer, and a lightly seeded fluid. In contrast to optical methods, this technique does not need to use laser light to interrogate the image pattern, so no secondary speckle is introduced. Also, the lower limit of displacement measurement is determined by the resolution of the sensor used and the magnification of the camera, and can be much lower than the speckle size, so a considerably wider range of measurement is possible than with optical processing. The technique can be completely automated and is potentially much faster than all of the optical methods currently used for flow visualization.

Matthys, Donald R.↗

Measurements of fluid oscillations in isochronous containers

An experiment was designed to measure the fluid oscillations in planar isochronous containers. Measurements of the resonant fluid response to forced oscillations provide direct experimental confirmation of the existence of these special containers.

Weidman, P. D.↗

Method of calibrating a fluid-level measurement system

A method of calibrating a fluid-level measurement system is provided. A first response of the system is recorded when the system's sensor(s) is (are) not in contact with a fluid of interest. A second response of the system is recorded when the system's sensor(s) is (are) fully immersed in the fluid of interest. Using the first and second responses, a plurality of expected responses of the system's sensor(s) is (are) generated for a corresponding plurality of levels of immersion of the sensor(s) in the fluid of interest.

Woodard, Stanley E.↗

Laser beam manifold and particle photography system for use in fluid velocity measurements

A laser beam manifold and particle photography system has been developed for use in fluid velocity measurements. The laser manifold is a device which transforms a single laser beam into several uniform parallel beams. By orienting two manifolds mutually perpendicular, an optical grid can be formed which acts as a reference for fluid velocity measurements. This optical grid is for all practical purposes totally nonperturbing to the flow. Tracer particles moving in the plane of the grid are then photographed to yield fluid velocities that can be measured relative to the optical grid. System construction and theory are presented.

Owen, R. B.↗

G-300: The first French Getaway Special microgravity measurements of fluid thermal conductivity

Thermal conductivity measurements on liquids are difficult to perform on Earth because of thermal motions due to convection. In microgravity, the convection due to buoyancy is evanescent, and a strong reduction of Rayleigh and Nusselt numbers can be expected. Three low viscosity liquids are selected to carry out the measurements; distilled water (standard) and two silicone oils. A modified hot plate method with a simplified guard ring is used; the reduction of convective motions permitted the use in the experimental cells of larger interplate distances and/or temperature differences than in Earth measurements, improving the accuracy. Comparisons between Earth and orbit results may help to understand the convection occurrence in the cells. Thermal, vibrational, and EMI tests have proved that the design satisfies the NASA requirements.

Perron, J. C.↗

Development of a prototype fluid volume measurement system

The research is reported in applying the axial fluid temperature differential flowmeter to a urine volume measurement system for space missions. The fluid volume measurement system is described along with the prototype equipment package. Flowmeter calibration, electronic signal processing, and typical void volume measurements are also described.

Poppendiek, H. F.↗

Capacitive Micro-Gravity Fluid Mass Gauge

Measuring fluid mass in micro gravity, where fluid behavior is dominated by fluid properties, is a challenging problem. To address this problem engineers at NASA are developing a capacitance-based, mass-fraction gauge for vessels containing two-phase fluids. The vessel volume is enclosed with an array of electrodes, and a unique set of capacitance measurements of the enclosed volume are made between the electrodes. The capacitance measurements are scaled with appropriate weighting factors derived from Laplace's Equation to compensate for the highly non-uniform electric fields inside the measurement volume and achieve a greater level of mass fraction accuracy.

Mark A Nurge↗

Wireless Fluid-Level Measurement System Equips Boat Owners

While developing a measurement acquisition system to be used to retrofit aging aircraft with vehicle health monitoring capabilities, Langley Research Center developed an innovative wireless fluid-level measurement system. The NASA technology was of interest to Tidewater Sensors LLC, of Newport News, Virginia, because of its many advantages over conventional fuel management systems, including its ability to provide an accurate measurement of volume while a boat is experiencing any rocking motion due to waves or people moving about on the boat. These advantages led the company to license this novel fluid-level measurement system from NASA for marine applications.

Source record↗

Electromagnetic probe technique for fluid flow measurements

The probes described herein, in various configurations, permit the measurement of the volume fraction of two or more fluids flowing through a pipe. Each probe measures the instantaneous relative dielectric constant of the fluid in immediate proximity. As long as separation of the relative dielectric constant of the fluid is possible, several or even many fluids can be measured in the same flow stream. By using multiple probes, the velocity of each fluid can generally be determined as well as the distribution of each constituent in the pipe. The values are determined by statistical computation. There are many potential applications for probes of this type in industry and government. Possible NASA applications include measurements of helium/hydrazine flow during rocket tests at White Sands, liquid/gas flow in hydrogen or oxygen lines in Orbiter engines, and liquid/gaseous Freon flow in zero gravity tests with the KS135 aircraft at JSC. Much interest has been shown recently by the oil industry. In this a good method is needed to measure the fractions of oil, water, and natural gas flowing in a pipeline and the velocity of each. This particular problem involves an extension of what has been developed to date and our plans to solve this problem will be discussed herein.

Arndt, G. D.↗

Electromagnetic Probe Technique for Fluid Flow Measurements

The probes described herein, in various configurations, permit the measurement of the volume fraction of two or more fluids flowing through a pipe. Each probe measures the instantaneous relative dielectric constant of the fluid in immediate proximity. As long as separation of the relative dielectric constants of each fluid is possible, several or even many fluids can be measured in the same flow steam. By using multiple probes, the velocity of each fluid can generally be determined as well as the distribution of each constituent in the pipe. The values are determined by statistical computation. There are many potential applications for probes of this type in industry and government. Possible NASA applications include measurements of helium/hydrazine flow during rocket tests at White Sands, liquid/gas flow in hydrogen or oxygen lines in Orbiter engines, and liquid/gaseous Freon flow in zero gravity tests with the KS135 aircraft at JSC. Much interest has been shown recently by the oil industry. In this industry, a good method is needed to measure the fractions of oil, water, and natural gas flowing in a pipeline and the velocity of each. This particular problem involves an extension of what has been developed to date and our plans and program to solve this problem will be discussed herein.

Arndt, G. D.↗