Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLOW REGULATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Tactile display device using an electrorheological fluid

A tactile display device utilizes an electrorheological fluid to activate a plurality of tactile dots. A voltage is selectively produced uniformly across an electrorheological fluid flowing between a common ground electrode and a plurality of conductive dot electrodes, thereby producing an increase in the fluid's viscosity to the extent that fluid flow between the two electrodes is restricted. The flow restriction produces a build-up of electrorheological fluid in a corresponding dot actuator chamber. The resulting pressure increase in the chamber displaces an elastic diaphragm fixed to a display surface to form a lump which can be perceived by the reader as one dot in a Braille character cell. A flow regulation system provides a continually pressurized flow system and provides for free flow of the electrorheological fluid through the plurality of dot actuator chambers when they are not activated. The device is adaptable to printed circuit techniques and can simultaneously display tactile dots representative of a full page of Braille characters stored on a medium such as a tape cassette or to display tactile dots representative of non-Braille data appearing on a computer monitor or contained on another data storage medium. In an alternate embodiment, the elastic diaphragm drives a plurality of spring-loaded pins provided with positive stops to maintain consistent displacements of the pins in both their actuated and nonactuated positions.

Garner, H. Douglas↗

Method and device for producing a tactile display using an electrorheological fluid

A tactile display device utilizes an electrorheological fluid to activate a plurality of tactile dots. A voltage is selectively produced uniformly across an electrorheological fluid flowing between a common ground electrode and a plurality of conductive dot electrodes, thereby producing an increase in the fluid's viscosity to the extent that fluid flow between the two electrodes is restricted. The flow restriction produces a build-up of electrorheological fluid in a corresponding dot actuator chamber. The resulting pressure increase in the chamber displaces an elastic diaphragm fixed to a display surface to form a lump which can be perceived by the reader as one dot in a Braille character cell. A flow regulation system provides a continually pressurized flow system and provides for free flow of the electrorheological fluid through the plurality of dot actuator chambers when they are not activated. The device is adaptable to printed circuit techniques and can simultaneously display tactile dots representative of a full page of Braille characters stored on a medium such as a tape cassette or to display tactile dots representative of non-Braille data appearing on a computer monitor or contained on another data storage medium. In an alternate embodiment, the elastic diaphragm drives a plurality of spring-loaded pins provided with positive stops to maintain consistent displacements of the pins in both their actuated and nonactuated positions.

Garner, H. Douglas↗

A Vehicle-to-Grid planning framework incorporating electric vehicle user equilibrium and distribution network flexibility enhancement

The rapid surge in electric vehicle (EV) adoption, coupled with advancements in charging technologies, emphasizes the critical necessity for expanding EV recharging infrastructure. Simultaneously, the Distribution Network (DN) encounters escalating challenges in meeting charging demand during peak traffic periods. Consequently, there is a mounting demand for the deployment of innovative Vehicle-to-Grid (V2G) technologies to augment the DN’s flexibility in power dispatch and alleviate travel costs for EV users. Hence, this paper proposes an EV-user-equilibrium-(UE)-constrained V2G planning framework that enhances flexibility in the DN. The framework aims to ascertain the optimal placement and capacity of EV charging stations (EVCSs) and V2G charging piles within the Transportation Network (TN). It takes into account the equilibrium condition stemming from competitive EV charging and routing behaviors alongside the optimal expansion of DN energy resources to accommodate the electricity supplied by the V2G piles. This study commences by analyzing EV drivers’ travel decisions, considering the influence of charging and V2G pile locations and sizes. Subsequently, we tackle the Traffic Assignment Problem with User Equilibrium (TAP-UE) model to characterize the steady-state traffic flow distribution of EVs. Following this, we formulate the optimization model for the Coordinated Power and Transportation Network (CPTN), which encompasses the optimal expansion of DN facilities and traffic flow regulation under UE conditions. To mitigate the computational complexity associated with the V2G planning model, we introduce a series of linearization methods to obtain a manageable Mixed-Integer Linear Programming (MILP) solution. Finally, to validate the efficacy of our proposed planning framework, we apply it to two test systems, including a real-world case study. Through these case studies, we explore the necessity and potential benefits of V2G technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Liquid Hydrogen Regulated Low Pressure High Flow Pneumatic Panel AFT Arrow Analysis

Project Definition: Design a high flow pneumatic regulation panel to be used with helium and hydrogen. The panel will have two circuits, one for gaseous helium (GHe) supplied from the GHe Movable Storage Units (MSUs) and one for gaseous hydrogen (GH2) supplied from an existing GH2 Fill Panel. The helium will supply three legs; to existing panels and on the higher pressure leg and Simulated Flight Tanks (SFTs) for the lower pressure legs. The hydrogen line will pressurize a 33,000 gallon vacuum jacketed vessel.

Jones, Kelley, M.↗

Pump and Flow Control Subassembly of Thermal Control Subsystem for Photovoltaic Power Module

The pump and flow control subassembly (PFCS) is an orbital replacement unit (ORU) on the Space Station Freedom photovoltaic power module (PVM). The PFCS pumps liquid ammonia at a constant rate of approximately 1170 kg/hr while providing temperature control by flow regulation between the radiator and the bypass loop. Also, housed within the ORU is an accumulator to compensate for fluid volumetric changes as well as the electronics and firmware for monitoring and control of the photovoltaic thermal control system (PVTCS). Major electronic functions include signal conditioning, data interfacing and motor control. This paper will provide a description of each major component within the PFCS along with performance test data. In addition, this paper will discuss the flow control algorithm and describe how the nickel hydrogen batteries and associated power electronics will be thermally controlled through regulation of coolant flow to the radiator.

Motil, Brian↗

Flow compensating pressure regulator

An apparatus for regulating pressure of treatment fluid during ophthalmic procedures is described. Flow sensing and pressure regulating diaphragms are used to modulate a flow control valve. The pressure regulating diaphragm is connected to the flow control valve to urge the valve to an open position due to pressure being applied to the diaphragm by bias means such as a spring. The flow sensing diaphragm is mechanically connected to the flow control valve and urges it to an opened position because of the differential pressure on the diaphragm generated by a flow of incoming treatment fluid through an orifice in the diaphragm. A bypass connection with a variable restriction is connected in parallel relationship to the orifice to provide for adjusting the sensitivity of the flow sensing diaphragm. A multiple lever linkage system is utilized between the center of the second diaphragm and the flow control valve to multiply the force applied to the valve by the other diaphragm and reverse the direction of the force.

Baehr, E. F.↗

NASA Small Engine Components Compressor Test Facility: High Efficiency Centrifugal Compressor Vaneless Diffuser and Transition Duct Configurations

The original vaned configuration of the High Efficiency Centrifugal Compressor (HECC) was developed with aggressive design targets to facilitate advancement of state-of-the-art technology in gas turbine compressors. This work documents modifications to the Small Engine Components Compressor Test Facility to support testing of the HECC vaneless diffuser and transition duct configurations, both of which are open geometries. These configurations were developed as follow-up studies to improve understanding of the differences between the predicted and actual performance of the original HECC vaned diffuser stage. Specifically, the vaneless diffuser was designed to provide the impeller with ideal exit conditions such that the impeller performance could be isolated from downstream stationary components, and the additively manufactured transition duct inlet configuration enables investigation into the effects of the inlet flow path on the stage performance. Features of note in the facility are active clearance control, bleed flow regulation, modular inlet configurations, and steady-state and fast-response instrumentation throughout the flow path. Details of the facility and instrumentation are presented as well as the baseline performance of the compressor stage. The geometry, performance, and detailed aerodynamic data have been made available to the public at https://storage.googleapis.com/heccdata/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

NASA Small Engine Components Compressor Test Facility: High Efficiency Centrifugal Compressor Vaneless Diffuser and Transition Duct Configurations

The original vaned configuration of the High Efficiency Centrifugal Compressor (HECC) was developed with aggressive design targets to facilitate advancement of state-of-the-art technology in gas turbine compressors. This work documents modifications to the Small Engine Components Compressor Test Facility to support testing of the HECC vaneless diffuser and transition duct configurations, both of which are open geometries. These configurations were developed as follow-up studies to improve understanding of the differences between the predicted and actual performance of the original HECC vaned diffuser stage. Specifically, the vaneless diffuser was designed to provide the impeller with ideal exit conditions such that the impeller performance could be isolated from downstream stationary components, and the additively manufactured transition duct inlet configuration enables investigation into the effects of the inlet flow path on the stage performance. Features of note in the facility are active clearance control, bleed flow regulation, modular inlet configurations, and steady-state and fast-response instrumentation throughout the flow path. Details of the facility and instrumentation are presented as well as the baseline performance of the compressor stage. The geometry, performance, and detailed aerodynamic data have been made available to the public at https://storage.googleapis.com/hecc-data/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

Refractory-based thermal energy storage for industrial process heat: one-dimensional modeling, control, and optimization

The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.

25 ENERGY STORAGE↗

Low flow characteristics for regulated and unregulated streams in North Carolina and prediction using climate signals

In this work, low flow statistics of regulated and unregulated streams in the state of North Carolina were updated with streamflow data through 2019. About 22% of the streams considered show a significant downward trend, but considerable low-frequency variability confounding trends. The relationship between regional index time series of groundwater-depth low flow and the Atlantic Multidecadal Oscillation (AMO) was examined to determine whether low-frequency climate modes can account for the long-term pattern in low flows. Consequently, a significant correlation was found between AMO and groundwater-depth low flow, such that positive AMO is associated with lower groundwater-depth low flow and vice versa, particularly for the Piedmont region. Predictive equations for annual low flows at the ecoregion level shows that springtime average streamflow and AMO were selected as the primary predictors of low flow for coastal and Piedmont regions, whereas springtime average streamflow and the November–December–January average Oceanic Niño Index were used as the primary predictors for the mountain region. The relative root mean square error (RMSE) of the disaggregated predictions to US Geologic Survey gauge locations was <23% at 79% of the stations, between 24% and 43% at 10% of the stations, and greater than 44% at 1% of the stations. The remaining 10% of stations showed large RMSEs. This latter percentage is characterized by smaller drainage basins and intermittent flows, suggesting the prediction models are not applicable to drainage basins smaller than roughly 20 square km and intermittent streams.

54 ENVIRONMENTAL SCIENCES↗

An Assessment of Technical Hydropower Potential at Non-Powered Dams in the United States

Historically, dams have been constructed for a variety of purposes, such as providing a more secure and reliable water supply, mitigating impacts from variations in river flow, allowing continuous navigability, and harnessing mechanical power. A relatively small portion of dams have been designed to store or regulate flows for the purpose of generating electricity (roughly 3% of nationally inventoried dams in the US and 17% of the dams included in the World Register of Dams). The remaining population of existing non-powered dams (NPDs) presents both an opportunity to generate renewable energy and a need to modernize aging infrastructure. This report describes an assessment of more than 2,600 NPDs in the US that have a collective potential of nearly 4 GW in new power capacity. Previous national-scale assessments were aimed at evaluating the theoretical maximum power potential at existing dams in the United States. These estimates were based on the best available information at the time for water availability, hydraulic head, and representative regional capacity factors. This study revisits a subset of 3,299 dams identified in the most recent theoretical resource assessment and uses more detailed and updated hydrologic data to produce estimates of technical potential. These improvements in data enable estimates that more realistically reflect what is physically possible given simple assumptions about the existing structure and constraints on flow and head (Figure 1).

13 HYDRO ENERGY↗

Shape of porous region to control cooling along curved exit boundary

A cooled porous insert in a curved wall has a specified spatially varying heat flux applied to one side. It is desired to control the distribution of coolant flow out through this curved surface so that the surface will be kept at a desired uniform temperature. The flow regulation is accomplished by shaping the surface through which the coolant enters the region to obtain the required variation of flow resistance within the region. The proper surface shape is found by solving a Cauchy boundary value problem. Analytical solutions are given in two dimensions for various shapes of the heated boundary subjected to different heating distributions.

Siegel, R.↗

Pressure sensitive gas flow meter

Regulator, which increases flow area in discrete steps as upstream pressure falls, maintains steady flow rate of gas as the supply pressure from storage system decreases.

Hallum, C. E.↗

Venturi Tube with Varying Mass Flow

Measurements on three tubes with flow regulated by suction at the trainling edge of the tube are described. It was possible to vary the mass of air flowing through the tube over a large range. Such tubes could be used for shrouded propellers.

Regenscheit, B.↗

Testing of a controller for a hybrid capillary pumped loop thermal control system

A controller for a series hybrid capillary pumped loop (CPL) system that requires no moving parts does not resrict fluid flow has been tested and has demonstrated improved performance characteristics over a plain CPL system and simple hybrid CPL systems. These include heat load sharing, phase separation, self-regulated flow control and distribution, all independent of most system pressure drop. In addition, the controlled system demonstrated a greater heat transport capability than the simple CPL system but without the large fluid inventory requirement of the hybrid systems. A description of the testing is presented along with data that show the advantages of the system.

Schweickart, Russell↗

Cooled Panel With Thermostats In All Passages

Simple shape-memory-alloy or bimaterial thermostatic valve incorporated in each passage of multiple-passage cooled panel, according to proposal. Thermostatic valves all set to same opening/closing temperature, so they regulate flows in all passages to equalize or nearly equalize temperature across panel in presence of transient, nonuniform surface heating. Concept beneficial in application in which overheating causes damage and both overcooling and excessive circulation of coolant occurs in absence of regulation if cooling capacity of panel made large enough to handle peak heat load. Potential applications include cooled structures for advanced hypersonic aircraft and engines.

Blosser, Max L.↗

A regional comparison of sub-daily flow variability in regulated and unregulated rivers in the United States

Regulating rivers for hydropower or other purposes can dramatically alter river flow patterns, including creating substantial changes in flow over short, minutes-to-hours-long timespans known as sub-daily flow variability (SDFV). The impacts of flexible hydropower production on flow and aquatic organisms are increasingly documented in research. However, the degree to which flow alteration relates to different hydropower operational modes in distinct geographical regions and seasons is not well understood. This study offers a methodology for regional- and species-appropriate evaluations of potential impacts of flow on fish based on sub-daily flow characteristics of hydropower operational modes. We analyzed 15-min discharge data between 2018 and 2021 from 69 USGS stream gages to compare SDFV in hydropeaking, run-of-river, and unregulated systems in the US Southeast and Pacific Northwest. Regulated systems exhibited significant SDFV downstream from hydropower facilities relative to unregulated systems, but specific impacts differed between regions. Regulated systems in the Southeast were characterized by high flow coefficients of variation and ratios (hydropeaking only) and extended durations of daily upramping flow phases. Regulated systems in the Pacific Northwest were characterized by many short flow phases per day and large portions of the day spent upramping. Pacific Northwest unregulated systems displayed the strongest seasonal flow patterns while Southeastern hydropeaking systems displayed the greatest SDFV. Given that SDFV impacts multiple dimensions of fish ecology, region-specific sub-daily flow signatures have important implications for understanding and mitigating potential community-, species-, and age-specific effects on fish in different parts of the country.

Fish↗