Engineering PapersSearch

SEARCH · Engineering Papers

Results for “FLOW MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mean and fluctuating flow measurements in axisymmetric supersonic boundary layer flow subjected to distributed adverse pressure gradients

Measurements have been made of the mean flow properties and turbulent fluctuations in adiabatic turbulent boundary layer flows subjected to distributed adverse pressure gradients. In the freestream region upstream of the adverse pressure gradient the Mach number was 3.86, the unit Reynolds number 5.3 million per foot. The boundary layer developed on the wall of an axisymmetric nozzle and straight test section. In order to avoid the effects of streamwise surface curvature the adverse pressure gradients at the test section wall were induced by contoured centerbodies mounted on the wind tunnel centerline. The flow under study simulated that which might be found in an axially symmetric engine inlet of a supersonic aircraft.

Gootzait, E.

ASRDI oxygen technology survey. Volume 6: Flow measurement instrumentation

A summary is provided of information available on liquid and gaseous oxygen flowmetering including an evaluation of commercial meters. The instrument types, physical principles of measurement, and performance characteristics are described. Problems concerning flow measurements of less than plus or minus two percent uncertainty are reviewed. Recommendations concerning work on flow reference systems, the use of surrogate fluids, and standard tests for oxygen flow measurements are also presented.

Mann, D. B.

Modeling studies for a Mars penetrator heat flow measurement

There were, two different design concepts considered for the purpose of measuring heat flow as part of a Mars penetrator mission. The first of the tentative designs utilizes temperature sensors emplaced along the trailing umbilicus at regularly spaced intervals, no greater than 1m, which is thermally coupled to the adjacent regolith radiatively and possibly convectively or conductively. The second of the heat flow designs considered requires the radial deployment of two or more low thermal mass temperature sensors outward from the penetrator body over a vertical (depth) range on the order of 1m.

Keihm, S. J.

Propellant mass usage and flow measurement

Practices are outlined for the design, installation, checkout, calibration, and operation of a system to be used for measuring propellant flow in a liquid monopropellant rocket engine. Design guidelines rather than detailed specifications are provided for the critical components of each portion of the system. System elemental uncertainties are presented in an appendix.

Source record

Mass flow measurement of liquid cryogens using the triboelectric effect

A cross correlator technique using triboelectric technology has been shown to be a feasible method to measure liquid flow rate for liquid nitrogen and JP4 jet fuel. This technology, invented and pioneered by Auburn International, Inc., is also expected to be suitable for use with all other insulating liquids and cryogens. The technology described is particularly well suited for cryogenic use, since the sensor is non-contacting and non-intrusive, and therefore, causes no additional pressure drop within the flow stream. Further development of the in-line sensor is required to produce a prototypical version for the test purposes under SSME fuel flow conditions. However, with the knowledge gained from this feasibility study, it is very likely that an acceptable sensor design for a full test bed evaluation could be produced.

Dechene, Ronald L.

An axial flow research compressor facility designed for flow measurement in rotor passages

An axial flow research compressor facility, which is designed for relative flow measurement, is described in this paper. The facility has a rotating probe traverse mechanism which is capable of traversing hot wire, pitot and other probes at 0.09 deg intervals across the rotor blade passage. The data transmission system includes rotating transducers, pressure transfer device, ten-channel mercury slip ring unit, scanivalve, etc. The instrumentation includes on-line data processing capability. A brief description of probes used as well as some typical data on the rotor blade static pressure, rotor endwall flow and rotor wake characteristics are given in the paper.

Lakshminarayana, B.

Three-Component Force and Mass-Flow Measurement on a Jet Nacelle

The present report contains three-component forces and mass-flow measurements on a jet nacelle at small inlet-velocity ratios v(sub A)/v(sub o) < 1. The mass-flow measurement on two cross sections of the nacelle demonstrate the local-velocity distribution with varying flow and angle of attack.

Ilgmann, G.

Detailed flow measurements in casing boundary layer of 429-meter-per-second-tip-speed two-stage fan

Detailed flow measurements between all blade rows were taken in the outer 30 percent of passage height of a two stage fan. Tabulations of the detailed flow measurements are included. Results of these measurements revealed the steep axial velocity profiles near the casing. The axial velocity profile near the casing at the rotor exists was much steeper than at the stator exits. The data also show overturning of the flow at the tip at the stator exits. The effect of mixing is shown by the redistribution of the first stage rotor exit total temperature profile as it passes through the following stator.

Gorrell, W. T.

An Innovative Flow-Measuring Device: Thermocouple Boundary Layer Rake

An innovative flow-measuring device, a thermocouple boundary layer rake, was developed. The sensor detects the flow by using a thin-film thermocouple (TC) array to measure the temperature difference across a heater strip. The heater and TC arrays are microfabricated on a constant-thickness quartz strut with low heat conductivity. The device can measure the velocity profile well into the boundary layer, about 65 gm from the surface, which is almost four times closer to the surface than has been possible with the previously used total pressure tube.

Hwang, Danny P.

Wake flow measurements with a mobile laser Doppler velocimeter system

Wake flow measurements were conducted with a mobile laser Doppler velocimeter (LDV). The measurements included surveys of aircraft wake vortices behind a B-747 aircraft, aircraft carrier wake measurements from aboard the U.S.S. Nimitz, and tower wake measurements for a 100 kW wind turbine. Results of these tests demonstrated that a mobile ground-based LDV is a versatile and useful tool for the measurement of full-scale three-dimensional wake flows. The potential is demonstrated for utilization of this system to study complex wakes for a variety of applications.

Wilson, D. J.

Guide to Flow Measurement for Electric Propulsion Systems

In electric propulsion (EP) systems, accurate measurement of the propellant mass flow rate of gas or liquid to the thruster and external cathode is a key input in the calculation of thruster efficiency and specific impulse. Although such measurements are often achieved with commercial mass flow controllers and meters integrated into propellant feed systems, the variability in potential propellant options and flow requirements amongst the spectrum of EP power regimes and devices complicates meter selection, integration, and operation. At the direction of the Committee on Standards for Electric Propulsion Testing, a guide was jointly developed by members of the electric propulsion community to establish a unified document that contains the working principles, methods of implementation and analysis, and calibration techniques and recommendations on the use of mass flow meters in laboratory and spacecraft electric propulsion systems. The guide is applicable to EP devices of all types and power levels ranging from microthrusters to high-power ion engines and Hall effect thrusters. The establishment of a community standard on mass flow metering will help ensure the selection of the proper meter for each application. It will also improve the quality of system performance estimates by providing comprehensive information on the physical phenomena and systematic errors that must be accounted for during the analysis of flow measurement data. This paper will outline the standard methods and recommended practices described in the guide titled "Flow Measurement for Electric Propulsion Systems."

spacecraft electric propulsion (EP) systems

Coherent light scattering spectroscopy for supersonic flow measurements

A unified discussion on coherent light scattering spectroscopy and its spectral dependence on molecular gas velocity, temperature and density is presented. The feasibility of using coherent Raman spectroscopy techniques for nonintrusive measurements of supersonic flow parameters is demonstrated and recent laboratory as well as wind tunnel experiments are reviewed. In addition, the advantages of using coherent Rayleigh-Brillouin spectroscopy for measuring high pressure flows are discussed.

She, C. Y.