New results from sub-3 MeV Compton spectrometer experiments

We report that our team at Los Alamos National Laboratory has successfully employed Compton spectrometers to measure the X-ray spectra of both continuous and flash radiographic sources. In this method, a collimated beam of X-rays incident on a converter foil ejects Compton electrons. A collimator may be inserted into the entrance of the spectrometer to narrow the angular acceptance of the forward-scattered electrons, which then enter the magnetic field region of the spectrometer. The position of the electrons at the magnet’s focal plane is proportional to the square root of their momentum, allowing the X-ray spectrum to be reconstructed. A new samarium-cobalt spectrometer with an energy range of 50 keV to 4 MeV has been fielded at two facilities. Finally, the X-ray generating machines produced intense photon beams (> 4 rad at 1 m) with spectral endpoints below 3 MeV. Recent experimental results will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highlights from the STAR Experiment

Despite the challenges of pandemic, the years 2020-21 were quite successful for STAR. We completed the Beam Energy Scan program phase 2 and installed the forward upgrade with which STAR finished data-taking for polarized p+p collisions at 510 GeV. In this contribution, we discuss STAR results on five different topics that were presented in twenty-one parallel talks, forty-seven posters, and two flash talks at the Quark Matter 11 2022 conference.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Deuterated-xylene Scintillator as a Neutron Spectrometer

We have experimentally characterized the neutron light output response functions of a deuterated-xylene scintillator for neutron energies lower than 10 MeV. We then used the response matrix to unfold the energy distribution of neutrons produced via several reactions, i.e. spontaneous fission, d(d,n)3He, 27Al(d,n)28Si, and 9Be(alpha,n)12C. Organic scintillators based on deuterated compounds show a fast response and good gamma-neutron discrimination capability, similar to proton-based scintillators. Deuterated scintillators can also effectively provide neutron spectra by unfolding measured data with the detector response matrix, without the need of time-of-flight. Deuteron recoils, produced by elastic collisions between deuterium and impinging neutrons, are preferentially forward-scattered. This non-isotropic reaction results in distinct peaks in the response functions to monoenergetic neutrons. In this work, we evaluated a custom-fabricated 7.62 cm x 7.62 cm deuterated-xylene (EJ301D) liquid scintillator. This liquid has a low volatility and higher flash point, compared to benzene-based deuterated detectors, e.g. EJ315 and NE230. We measured the EJ301D detector neutron response matrix (up to 6 MeV neutron energy) using an intense Cf252 source and the time-of-flight technique. The number of response functions obtained using our method is only limited by counting statistics and by the experimentally achievable energy resolution. Multi-channel unfolding was performed successfully for neutron spectra with different energy spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Talbot-Lau X-Ray Deflectometry for Dynamic Density Profile Measurements

X-ray phase contrast imaging with transmission gratings for density profile measurements is being developed for dynamic experimental applications. Talbot-Lau deflectometry is a new method of measuring x-ray refraction in addition to attenuation and ultra-small angle scattering that has recently been developed for static imaging, primarily for medical and industrial applications. A flash x-ray source, with a spot size much larger than the continuous microfocus sources of static imaging systems, must be used to obtain density profiles from fast-evolving systems, and only a single exposure can be obtained. These new challenges are addressed by introducing an asymmetric setup and developing a forward modeling technique to infer an electron density profile from a single-image, low spatial–resolution system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TIA: A forward model and analyzer for Talbot interferometry experiments of dense plasmas

Interferometry is one of the most sensitive and successful diagnostic methods for plasmas. However, owing to the design of most common interferometric systems, the wavelengths of operation and, therefore, the range of densities and temperatures that can be probed are severely limited. Talbot–Lau interferometry offers the possibility of extending interferometry measurements to x-ray wavelengths by means of the Talbot effect. While there have been several proof-of-concept experiments showing the efficacy of this method, it is only recently that experiments to probe High Energy Density (HED) plasmas using Talbot–Lau interferometry are starting to take place. To improve these experimental designs, we present here the Talbot-Interferometry Analyzer (TIA) tool, a forward model for generating and postprocessing synthetic x-ray interferometry images from a Talbot–Lau interferometer. Although TIA can work with any two-dimensional hydrodynamic code to study plasma conditions as close to reality as possible, this software has been designed to work by default with output files from the hydrodynamic code FLASH, making the tool user-friendly and accessible to the general plasma physics community. Here, the model has been built into a standalone app, which can be installed by anyone with access to the MATLAB runtime installer and is available upon request to the authors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient carrier relaxation and fast carrier recombination of N-polar InGaN/GaN light emitting diodes

Based on quantum efficiency and time-resolved electroluminescence measurements, the effects of carrier localization and quantum-confined Stark effect (QCSE) on carrier transport and recombination dynamics of Ga- and N-polar InGaN/GaN light-emitting diodes (LEDs) are reported. The N-polar LED exhibits shorter ns-scale response, rising, delay, and recombination times than the Ga-polar one does. Stronger carrier localization and the combined effects of suppressed QCSE and electric field and lower potential barrier acting upon the forward bias in an N-polar LED provide the advantages of more efficient carrier relaxation and faster carrier recombination. By optimizing growth conditions to enhance the radiative recombination, the advantages of more efficient carrier relaxation and faster carrier recombination in a competitive performance N-polar LED can be realized for applications of high-speed flash LEDs. The research results provide important information for carrier transport and recombination dynamics of an N-polar InGaN/GaN LED.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MAGNETIZATION DEGREE OF GAMMA-RAY BURST FIREBALLS: NUMERICAL STUDY

The relative strength between forward and reverse shock emission in early gamma-ray burst (GRB) afterglow reflects that of magnetic energy densities in the two shock regions. We numerically show that with the current standard treatment, the fireball magnetization is underestimated by up to two orders of magnitude. This discrepancy is especially large in the sub-relativistic reverse shock regime (i.e., the thin shell and intermediate regime), where most optical flashes were detected. We provide new analytic estimates of the reverse shock emission based on a better shock approximation, which well describe numerical results in the intermediate regime. We show that the reverse shock temperature at the onset of afterglow is constant, ( {Gamma}-bar{sub d}-1){approx}8 Multiplication-Sign 10{sup -2}, when the dimensionless parameter {xi}{sub 0} is more than several. Our approach is applied to case studies of GRB 990123 and 090102, and we find that magnetic fields in the fireballs are even stronger than previously believed. However, these events are still likely to be due to a baryonic jet with {sigma} {approx} 10{sup -3} for GRB 990123 and {approx}3 Multiplication-Sign 10{sup -4} to 3 for GRB 090102.

79 ASTRONOMY AND ASTROPHYSICS↗

Empirical beam hardening correction (EBHC) for CT

Purpose: Due to x-ray beam polychromaticity and scattered radiation, attenuation measurements tend to be underestimated. Cupping and beam hardening artifacts become apparent in the reconstructed CT images. If only one material such as water, for example, is present, these artifacts can be reduced by precorrecting the rawdata. Higher order beam hardening artifacts, as they result when a mixture of materials such as water and bone, or water and bone and iodine is present, require an iterative beam hardening correction where the image is segmented into different materials and those are forward projected to obtain new rawdata. Typically, the forward projection must correctly model the beam polychromaticity and account for all physical effects, including the energy dependence of the assumed materials in the patient, the detector response, and others. We propose a new algorithm that does not require any knowledge about spectra or attenuation coefficients and that does not need to be calibrated. The proposed method corrects beam hardening in single energy CT data. Methods: The only a priori knowledge entering EBHC is the segmentation of the object into different materials. Materials other than water are segmented from the original image, e.g., by using simple thresholding. Then, a (monochromatic) forward projection of these other materials is performed. The measured rawdata and the forward projected material-specific rawdata are monomially combined (e.g., multiplied or squared) and reconstructed to yield a set of correction volumes. These are then linearly combined and added to the original volume. The combination weights are determined to maximize the flatness of the new and corrected volume. EBHC is evaluated using data acquired with a modern cone-beam dual-source spiral CT scanner (Somatom Definition Flash, Siemens Healthcare, Forchheim, Germany), with a modern dual-source micro-CT scanner (TomoScope Synergy Twin, CT Imaging GmbH, Erlangen, Germany), and with a modern C-arm CT scanner (Axiom Artis dTA, Siemens Healthcare, Forchheim, Germany). A large variety of phantom, small animal, and patient data were used to demonstrate the data and system independence of EBHC. Results: Although no physics apart from the initial segmentation procedure enter the correction process, beam hardening artifacts were significantly reduced by EBHC. The image quality for clinical CT, micro-CT, and C-arm CT was highly improved. Only in the case of C-arm CT, where high scatter levels and calibration errors occur, the relative improvement was smaller. Conclusions: The empirical beam hardening correction is an interesting alternative to conventional iterative higher order beam hardening correction algorithms. It does not tend to over- or undercorrect the data. Apart from the segmentation step, EBHC does not require assumptions on the spectra or on the type of material involved. Potentially, it can therefore be applied to any CT image.

60 APPLIED LIFE SCIENCES↗

A measurement of the energy and timing resolution of GlueX Forward Calorimeter using an electron beam

The performance of the GlueX Forward Calorimeter was studied using a small version of the detector and a variable energy electron beam derived from the Hall B tagger at Jefferson Lab. For electron energies from 110 MeV to 260 MeV, which are near the lower-limits of the design sensitivity, the fractional energy resolution was measured to range from 20% to 14%, which meets the design goals. The use of custom 250 MHz flash ADCs for readout allowed precise measurements of signal arrival times. The detector achieved timing resolutions of 0.38 ns for a single 100 mV pulse, which will allow timing discrimination of photon beam bunches and out-of-time background during the operation of the GlueX detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and investigation of the anomalous behavior of the immersed-B{sub z} diode during operation at 4 to 5 MV

The immersed-B{sub z} diode is being developed as a high-brightness, flash x-ray radiography source at Sandia National Laboratories. This diode is a foil-less electron-beam diode with a long, thin, needlelike cathode which is inserted into the bore of a solenoid. The solenoidal magnetic field guides the electron beam emitted from the cathode to the anode while maintaining a small beam radius. The electron beam strikes a thin, high-atomic-number anode and produces forward-directed bremsstrahlung. In addition, electron beam heating of the anode produces surface plasmas allowing ion emission. Two different operating regimes for this diode have been identified: A nominal operating regime where the total diode current is characterized as classically bipolar with stable impedance [see D. C. Rovang et al., Phys. Plasmas 14, 113107 (2007)] and an anomalous operating regime characterized by a rapid impedance collapse where the total diode current greatly exceeds the bipolar limit. The operating regimes are approximately separated by cathode diameters greater than 3 mm for the nominal regime and less than 3 mm for the anomalous impedance collapse regime. Results from a comprehensive series of experiments conducted at 4-5 MV characterizing the transition from this nominal operating regime to the anomalous operating regime as the cathode diameter is reduced are presented. Results from experiments investigating the effects of anode-cathode gap, anode material, and cryogenic modification of the anode surface are also presented. Although these investigations were unsuccessful in completely mitigating the anomalous behavior, insight gained from these experiments has elucidated several key physics issues that are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The afterglow of XRF 071031: Evidence for correlated optical and X-ray flares

We present a densely sampled early light curve of the optical/near-infrared (NIR) afterglow of the X-Ray Flash (XRF) 071031 at z 2.692. Continuous observations in seven photometric bands from g' to K{sub S} simultaneously with the Gamma Ray Burst Optical Near-Infrared Detector (GROND) at the 2.2 m MPI/ESO telescope on LaSilla were performed between 4 minutes and 7 hours after the burst. The optical/NIR light curve is dominated by an early increase in brightness which can be attributed to the apparent onset of the forward shock (FS) emission. In addition, there are several bumps which are superimposed onto the overall rise and decay. Significant flaring is also visible in the Swift X-Ray Telescope (XRT) light curve at early and late times. The broadband data enables detailed studies of the connection between the X-ray and optical/NIR afterglow and its colour evolution during the first night post burst. We find evidence of spectral hardening in the optical spectral energy distribution contemporaneous with the emergence of the bumps from an underlying afterglow component. The bumps in the optical/NIR light curve can be associated with flares in the X-ray regime suggesting late central engine activity as the common origin.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of feed-rod tilting on friction surfacing of steel

During the friction surfacing process, the forge-axial force, rotation rate, and traverse speed of the consumable feed-rod play crucial roles in determining the deposition rate and layer morphology. Although some researchers have studied the enhancement of deposition by introducing a backward tilt relative to the traverse direction, there has been limited investigation into the effects of other tilt orientations. Therefore, this study aims to provide a more comprehensive understanding of feed-rod tilting in friction surfacing. In this investigation, the consumable feed-rod undergoes tilting in four distinct directions: forward, backward, advancing side, and retreating side, each tested at two different tilt angles (1.5° and 3.0°). The results reveal that the feed-rod tilting can influence the deposition dynamics by altering the location and area of the rubbing interface situated between the feed-rod and the substrate. Moreover, the feed-rod tilting can significantly enhance the bond width, deposition rate, and deposition efficiency. The enhancement in deposition efficiency signifies a successful reduction in flash formation. Furthermore, a distinct layered microstructure is evident within each deposition layer, regardless of tilt conditions, indicating the unique deposition process inherent to friction surfacing. Finally, the innovative approach proposed in this study not only offers a straightforward and feasible means to improve deposition rate and efficiency but also expands the potential for constructing more intricate geometries or authentic surfaces.

36 MATERIALS SCIENCE↗

Three-Dimensional Imaging through Shock-Waves at Ultra-High Speed

Imaging diagnostics that utilize coherent light, such as digital in-line holography, are important for object sizing and tracking applications. However, in explosive, supersonic, or hypersonic environments, gas-phase shocks impart imaging distortions that obscure internal objects. To circumvent this problem, some research groups have conducted experiments in vacuum, which inherently alters the physical behavior. Other groups have utilized single-shot flash x-ray or high-speed synchrotron x-ray sources to image through shock-waves. In this work, we combine digital in-line holography with a phase conjugate mirror to reduce the phase distortions caused by shock-waves. The technique operates by first passing coherent light through the shock-wave phase-distortion and then a phase-conjugate mirror. The phase-conjugate mirror is generated by a four-wave mixing process to produce a return beam that has the exact opposite phase-delay as the forward beam. Therefore, by passing the return beam back through the phase-distortion, the phase delays picked up during the initial pass are canceled, thereby producing improved coherent imaging. In this work, we implement phase conjugate digital in-line holography (PCDIH) for the first time with a nanosecond pulse-burst laser and ultra-high-speed cameras. This technique enables accurate measurement of the three-dimensional position and velocity of objects through shock-wave distortions at video rates up to 5 MHz. This technology is applied to improve three-dimensional imaging in a variety of environments from imaging supersonic shock-waves through turbulence, sizing objects through laser-spark plasma-generated shock-waves, and tracking explosively generated hypersonic fragments. Theoretical foundations and additional capabilities of this technique are also discussed.

47 OTHER INSTRUMENTATION↗

GRB 081007 AND GRB 090424: THE SURROUNDING MEDIUM, OUTFLOWS, AND SUPERNOVAE

We discuss the results of the analysis of multi-wavelength data for the afterglows of GRB 081007 and GRB 090424, two bursts detected by Swift. One of them, GRB 081007, also shows a spectroscopically confirmed supernova, SN 2008hw, which resembles SN 1998bw in its absorption features, while the maximum magnitude may be fainter, up to 0.7 mag, than observed in SN 1998bw. Bright optical flashes have been detected in both events, which allows us to derive solid constraints on the circumburst-matter density profile. This is particularly interesting in the case of GRB 081007, whose afterglow is found to be propagating into a constant-density medium, yielding yet another example of a gamma-ray burst (GRB) clearly associated with a massive-star progenitor which did not sculpt the surroundings with its stellar wind. There is no supernova component detected in the afterglow of GRB 090424, likely due to the brightness of the host galaxy, comparable to the Milky Way. We show that the afterglow data are consistent with the presence of both forward- and reverse-shock emission powered by relativistic outflows expanding into the interstellar medium. The absence of optical peaks due to the forward shock strongly suggests that the reverse-shock regions should be mildly magnetized. The initial Lorentz factor of outflow of GRB 081007 is estimated to be {Gamma} {approx} 200, while for GRB 090424 a lower limit of {Gamma} > 170 is derived. We also discuss the prompt emission of GRB 081007, which consists of just a single pulse. We argue that neither the external forward-shock model nor the shock-breakout model can account for the prompt emission data and suggest that the single-pulse-like prompt emission may be due to magnetic energy dissipation of a Poynting-flux-dominated outflow or to a dissipative photosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Beam Test Results of the GlueX Forward Calorimeter

GlueX is an experiment to begin running in the near future at Jefferson Lab. Our research group is responsible for the forward calorimeter (FCAL) that is designed to measure the energy of photons produced from the decays of mesons. Recently, we conducted a beam test at Jefferson Lab using a prototype of the FCAL. Its goal was to experimentally verify the energy resolution of the FCAL as a function of beam energy. The prototype was tested with recoil electrons ranging in energy from 113MeV to 277MeV. We obtained the resolution by comparing the reconstructed energy to the known energy. In addition, we corrected our measured resolution for multiple scattering and energy loss based on a GEANT4 simulation of the prototype. Another important goal of the beam test was to measure the timing resolution of the channels on our flash analog to digital converters (fADCs). For GlueX, we need to require the timing resolution to be much less than the bunch spacing (2ns). The results of our studies indicate that the energy resolution of the FCAL is consistent with our predictions. We also found the timing resolution as a function of signal size and the results agreed with a similar study. For signals of about at least 75mV, the timing resolution achieved was significantly lower than 2ns.

Bauer, Kevin↗

Inverse transport problem solvers based on regularized and compressive sensing techniques

According to the direct exposure measurements from flash radiographic image, regularized-based method and compressive sensing (CS)-based method for inverse transport equation are presented. The linear absorption coefficients and interface locations of objects are reconstructed directly at the same time. With a large number of measurements, least-square method is utilized to complete the reconstruction. Owing to the ill-posedness of the inverse problems, regularized algorithm is employed. Tikhonov method is applied with an appropriate posterior regularization parameter to get a meaningful solution. However, it's always very costly to obtain enough measurements. With limited measurements, CS sparse reconstruction technique Orthogonal Matching Pursuit (OMP) is applied to obtain the sparse coefficients by solving an optimization problem. This paper constructs and takes the forward projection matrix rather than Gauss matrix as measurement matrix. In the CS-based algorithm, Fourier expansion and wavelet expansion are adopted to convert an underdetermined system to a well-posed system. Simulations and numerical results of regularized method with appropriate regularization parameter and that of CS-based agree well with the reference value, furthermore, both methods avoid amplifying the noise. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Another Nobel Prize linked to synchrotron radiation work

The 2008 Nobel Prize in Chemistry went to Osamu Shimomura, Martin Chalfie and Roger Tsien 'for the discovery and development of the green fluorescent protein, GFP'. This year's Nobel Prize in Chemistry rewards the initial discovery of GFP and a series of important developments which have led to its use as a tagging tool in bioscience. By using DNA technology, researchers can now connect GFP to other interesting, but otherwise invisible, proteins. This glowing marker allows the movements, positions and interactions of the tagged proteins to be monitored. Osamu Shimomura was the first to isolate GFP from the jellyfish Aequorea victoria, found off the west coast of North America, and discovered the protein's green glow [Shimomura et al. (1962). J. Cell. Comp. Physiol. 59, 223-240]. Martin Chalfie demonstrated the value of GFP as a luminous genetic tag. In one of his first experiments he coloured six individual cells in the transparent roundworm Caenorhabditis elegans with the aid of GFP. He had obtained the GFP gene (gfp) clone from Prasher [Prasher et al. (1992). Gene, 111, 229-233] and expressed it in E. coli. The GFP protein displayed a bright green fluorescence in this heterologous organism, suggesting that it could indeed serve as a versatile genetic marker in virtually all organisms. Chalfie transformed C. elegans with gfp under the control of a promoter regulating the expression of {beta}-tubulin, abundant in six touch receptor neurons in C. elegans. The organism subsequently expressed GFP from distinct positions in its body and at distinct times in its development [Chalfie et al. (1994). Science, 263, 802-805]. Roger Tsien contributed to the general understanding of how GFP glows by determining the formation of the GFP chromophore, a chemical group that absorbs and emits light. Tsien is best known for extending the colour palette of GFP beyond green, allowing researchers to follow several different biological processes at the same time. According to background on the Nobel Prize website, 'An important step forward, allowing for rational design of mutants, was the solution of the crystal structure of GFP.' Tsien collaborated with Jim Remington and his team who solved the structure of GFP at 1.9 {angstrom} using data in part collected at NSLS beamline X4A. Tsien and Remington were able to use the structural information and design specific mutants (Thr203, to Tyr or His) which resulted in significantly red-shifted excitation and emission maxima and thus converting GFP into YFP (yellow fluorescence protein) [Ormo et al. (1996). Science, 273, 1392-1395]. Acknowledging the contribution of NSLS Brookhaven, University of Oregon scientist Remington said 'The data collected at beamline X4A were essential to solve the structure of GFP. We were unable to solve the structure using native and heavy-atom-derivative data sets collected at home'. Remington added 'In those days the technology to flash freeze crystals had not been fully worked out and so diffraction data had to be collected at temperatures above freezing. Crystal lifetime was very short. At X4A, a crystal cooling system enabled data collection at close to zero degrees Celsius, extending the crystal lifetime, while the intense beam permitted data to be collected at significantly higher resolution. In addition, the tunable nature of the source allowed us to collect data at the selenomethionine absorption edge, which dramatically improved the signal for phasing purposes. The improved phasing, combined with higher resolution data, resulted in an interpretable electron density map. The first look at the GFP chromophore in that electron density map was one of the most exciting moments of my entire career.'

36 MATERIALS SCIENCE↗

A VXS [VITA41] Trigger Processor for the 12GEV Experimental Programs at Jefferson Lab

The VXS_Trigger_Processor [VTP] was developed and commissioned for CLAS12 in the fall of 2016. This board is a VITA41 switch card and it collects data from a variety of front-end TDC and Flash ADC modules. The VTP has since been used in several experiments at Jefferson Lab serving as the L1 trigger module for a variety of detector types, such as stacked calorimeters, strip calorimeters, time-of-flight, Cerenkov, hodoscopes, drift chambers, and silicon strips. Trigger algorithms implemented include cluster finding (1D, 2D), drift chamber segment and road finding, geometry matching between various detectors, particle counting, and general global trigger bit processing. The VTP is also capable of reading out each front-end crate with up to 40Gbps Ethernet which is an enormous increase compared to the currently used 200MB/s VME bus. Recent progress has been made to show that a firmware and software upgrade can enable existing Jefferson Lab front-end crates to operate in a streaming DAQ mode. In February 2020, tests will be performed on a full calorimeter and matched hodoscope which are components of the CLAS12 Forward Tagger detector system with beam in Hall B. This paper details the hardware performance, triggered, and streaming applications that have been implemented using the VTP for several experiments at Jefferson Lab.