Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FIREFIGHTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Utilizing multimodal high-intensity interval training for a firefighter training academy during the COVID-19 pandemic

Firefighters typically undergo a 16–24-week training academy during which they perform a variety of traditional exercise programs such as cardiovascular, resistance, and concurrent training. Because of limited facility access, some fire departments seek alternative exercise programs, such as multimodal high-intensity interval training (MM-HIIT), which essentially combines resistance and interval training. Here, the primary purpose of this study was to assess the effect of MM-HIIT on body composition and physical fitness in firefighter recruits who completed a training academy during the coronavirus (COVID-19) pandemic. A secondary purpose was to compare the effects of MM-HIIT to previous training academies that implemented traditional exercise programs. Healthy and recreationally-trained recruits (n=12) participated in 2-3 days/week of MM-HIIT for 12 weeks and had several components of body composition and physical fitness measured before and after the program. Because of COVID-19-related gym closures, all MM-HIIT sessions were performed outdoors at a fire station with minimal equipment. These data were retroactively compared to a control group (CG) that previously completed training academies with traditional exercise programs. Subjects in the MM-HIIT group significantly improved several components of body composition and fitness, including fat mass, fat-free mass, body fat percentage, aerobic capacity, and muscular endurance (p < 0.005). Moreover, there were no significant differences for any dependent variable when MM-HIIT was compared to the CG (p≥0.005). These results suggest that MM-HIIT may serve as an effective substitute for traditional concurrent training paradigms that are typically used for firefighter academies.

60 APPLIED LIFE SCIENCES↗

The NASA Firefighter's Breathing System Program: A Status Report

The National Aeronautics and Space Administration (NASA), through its Technology Utilization Program, has been making its advanced technology developments available to the public. This has coincided in recent years with a growing demand within the fire service for improved protective equipment. A better breathing system for firefighters was one of the more immediate needs identified by the firefighting organizations. The Johnson Space Center (JSC), based upon their experience in providing life support systems for space flight, was subsequently requested to determine the feasibility of providing an improved breathing system for firefighters. Such a system was determined to be well within the current state of the art, and the Center is well into a development program to provide design verification of this improved protective' equipment. This report - outlines the overall objectives of this program, progress to date, and future planned activities.

McLaughlan, Pat B.↗

Lung function changes in wildland firefighters working at prescribed burns.

Although decline in lung function across workshift has been observed in wildland firefighters, measurements have been restricted to days when they worked at fires. Consequently, such results could have been confounded by normal circadian variation associated with lung function. We investigated the across-shift changes in lung function of wildland firefighters, and the effect of cumulative exposure on lung function during the burn season.

60 APPLIED LIFE SCIENCES↗

Solar/Photovoltaic DC Systems: Information for Electrical Workers and Firefighters

Solar photovoltaic (PV) systems are common and continue to gain popularity. This article helps electrical workers and firefighters understand basic operating principles and hazards of PV dc arrays. The effects of solar radiation and temperature on power output are discussed including; PV-module testing standards; methods for calculating the number of modules in a PV string; some National Electrical Code (NEC) guidelines that are aimed toward improving array safety; dc-array commissioning, periodic maintenance, and testing; arc-flash-hazard potential ways firefighters can work safely around PV arrays; potential risks posed by moonlight and other light sources; some unique dc-system hazards. We also present statistics on PV dc-array electrical incidents and injuries.

14 SOLAR ENERGY↗

Photovoltaics and Firefighters' Operations: Best Practices in Selected Countries

Components of photovoltaic (PV) systems undergo rigorous safety and reliability testing protocols during manufacturing and fulfill the electrical safety requirements established by various codes and standards. These systems do not pose health, safety, or environmental risks under normal operating conditions if properly installed and maintained by trained personnel as required by electrical codes. However, with the ever-growing deployment of PV systems globally and the myriad of applications - from traditional rooftop and ground-mounted installations to more advanced building-integrated and facade systems - it is becoming increasingly important to develop practices and share knowledge on the safe management and risk mitigation of PV systems under non-routine circumstances. This focus includes conditions in which firefighters encounter a PV system that may have been installed improperly or has become damaged. This report aims to facilitate the exchange of knowledge on the best practices and standards of firefighters' operations in relation to selected countries with considerable deployment of PV systems.

14 SOLAR ENERGY↗

NASA firefighters breathing system program report

Because of the rising incidence of respiratory injury to firefighters, local governments expressed the need for improved breathing apparatus. A review of the NASA firefighters breathing system program, including concept definition, design, development, regulatory agency approval, in-house testing, and program conclusion is presented.

Wood, W. B.↗

Improved Clothing for Firefighters

Application of space technology should reduce incidence of injuries, heat exhaustion, and fatigue in firefighters. Using advanced materials and design concepts of aerospace technology, protective gear was fabricated and tested for the heat, face, torso, hand and foot. In tests, it was found that new gear protects better than conventional firefighter gear, weighs 40 percent less, and reduces wearer's energy expenditure by 25 percent.

Abeles, F. J.↗

Improved Gloves for Firefighters

New firefighter's gloves are more flexible and comfortable than previous designs. Since some firefighters prefer gloves made of composite materials while others prefer dip-coated gloves, both types were developed. New gloves also find uses in foundries, steelmills, and other plants where they are substituted for asbestos gloves.

Tschirch, R. P.↗

Firefighters' communication transceiver test plan

The requirements for the operational testing of the firefighters communication transceiver were identified. The major concerns centered around the integrity and reliability of the firefighter/microphone interface. The major concern about the radio hardware was that it be intrinsically safe in hazardous atmospheres and that the system not interfere with the fit or facial seal of self-contained breathing apparatus (SCBA). The greatest concern for operational testing purposes as the reliability and clarity of the line of communication between the firefighter and those on the fireground with whom he must maintain contact. A desire to test any units developed in both training exercises and in real responses to hazardous material incidents was expressed. It is felt that a VOX-microphone built into the SCBA facemask gives the best performance. A voice-pickup product device which combines a bone conduction microphone and a speaker into a single ear mounted unit is examined.

Wallace, R. J.↗

Advanced Transceivers for Firefighters

Report presents concept of improved portable radio transceiver for firefighters. Based in part on study of propagation of radio waves in such environments as high-rise buildings, ships, and tunnels. Study takes into account possible health hazard posed by personal tranceivers and needs and wishes expressed by firefighters in interviews. Conceptual radio attaches to clothing to allow hands-free use; voice-actuated with microphone worn at throat. Speaker placed near wearer's shoulder. Flexible antenna placed either horizontally across shoulders, vertically at one shoulder, or on transceiver itself.

Blood, B. D.↗

High-Capacity, Portable Firefighting Pump

Report describes an evaluation of firefighting module that delivers water at 5,000 gal/min (320 L/s). Is compact, self-contained, portable water pump. Besides firefighting, module used for flood control, pumping water into large vessels, and pump water from sinking ships.

Burns, Ralph A.↗

Firefighting Module

Firefly II pump module is NASA's Marshall Space Flight Center's commercial offshoot of a NASA/US Coast Guard program involving development of a lightweight, helicopter-transportable firefighting module for a quick response in combating shipboard or harbor fires. Operable on land or water, the Amphib One is equipped with 3 water cannons. When all 3 are operating, unit pumps more than 3,000 gallons a minute. Newly developed model used by U.S. Coast Guard can pump 5,000 gallons per minute. It was designed for applications such as firefighting onboard ship fires, emergency dockside water pumping, dewatering ships in danger of sinking, flood control, and emergency water supply at remote locations.

Source record↗

Firefighters' Radios

Public Technology Inc. asked for NASA assistance to devise the original firefighter's radio. Good short-range radio communications are essential during a fire to coordinate hose lines, rescue victims, and otherwise increase efficiency. Useful firefighting tool is lower cost, more rugged short range two-way radio. Inductorless electronic circuit replaced inductances and coils in radio circuits with combination of transistors and other low-cost components. Substitution promises reduced circuit size and cost. Enhanced electrical performance made radio more durable and improved maintainability by incorporating modular construction.

Source record↗

Firefighting Module

NASA and the U.S. Coast Guard are working jointly to develop a helicopter transportable firefighting module that can shave precious minutes in combating shipboard or harbor fires. The program was undertaken in 1975, after a series of disastrous fires on oil tankers indicated a need for a lightweight, self-contained system that could be moved quickly to the scene of a fire. A prototype module was delivered to the Coast Guard last year and service testing is under way. The compact module weighs little more than a ton but it contains everything needed to fight a fire. The key component is a high output pump, which delivers up to 2,000 gallons of sea water a minute; the pump can be brought up to maximum output in only one minute after turning on the power source, a small Allison gas turbine engine. The module also contains hose, a foam nozzle and a spray nozzle, three sets of protective clothing for firefighters, and fuel for three hours operation. Designed to be assembled without special tools, the module can be set up for operation in less than 20 minutes.

Source record↗

Evaporation-Cooled Protective Suits for Firefighters

Suits cooled by evaporation of water have been proposed as improved means of temporary protection against high temperatures near fires. When air temperature exceeds 600 F (316 C) or in the presence of radiative heating from nearby sources at temperatures of 1,200 F (649 C) or more, outer suits now used by firefighters afford protection for only a few seconds. The proposed suits would exploit the high latent heat of vaporization of water to satisfy a need to protect against higher air temperatures and against radiant heating for significantly longer times. These suits would be fabricated and operated in conjunction with breathing and cooling systems like those with which firefighting suits are now equipped

Weinstein, Leonard Murray↗

LAFD: TA-15 DARHT Firefighter Facility Familiarization Tour, OJT 53044, Revision 0.2

The Los Alamos National Laboratory (LANL or the Lab) will conduct familiarization tours for the Los Alamos County Fire Department (LAFD) at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility, TA-15-0312. The purpose of these tours is to orient LAFD firefighters to the DARHT facility layout and hazards. This document provides information and figures to supplement the familiarization tours. The document will be distributed to the trainees at the time of the familiarization tour. A checklist (Attachment A) has also been developed to ensure that all required information is consistently presented to LAFD personnel during the familiarization tours.

99 GENERAL AND MISCELLANEOUS↗

A Conservative Approach to Defining Photovoltaic System Hazards to Firefighters

Sandia National Laboratories performed analysis to develop conservative hazard guidelines regarding firefighters working near photovoltaic (PV) arrays. Assuming implementation of NFPA 70 system shutdown requirements, the analysis focused on DC hazards only. Several different PV variables were considered, including system grounding and DC voltage classes. The hazard scenarios considered the contact conditions, current paths through the body, and PPE. Guidelines for the hazard definitions for men and women were based on the IEC TS 60479-1 guidelines. The importance of PPE was illustrated in the results.

14 SOLAR ENERGY↗

Crew equipment applications - Firefighter's Breathing System.

The Firefighter's Breathing System (FBS) represents a significant step in applying NASA's crew equipment technologists and technologies to civilian sector problems. This paper describes the problem, the utilization of user-design committees as a forum for development of design goals, the design of the FBS, and the field test program to be conducted.

Smith, W. L.↗