Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FIB tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Towards a quantitative understanding of bonding in supersonic single particle impacts: A three-dimensional FIB-SEM exploration

Particle bonding is crucial to coating quality in cold spray, but it has been a challenge to accurately quantify bonding even in single particle impacts. This paper uses FIB-SEM to explicitly map the particle-substrate interface for Cu-on-Cu single microparticle impacts in a full 3D rendering that spans a wide range of impact velocities. This approach permits a detailed quantification of the total bonding area and all of its associated components. In addition to revealing why prior 2D characterization efforts have missed important details about impact bonding, these data quantitatively reveal the evolution of bonding from its onset at the “critical velocity” V cr (where bonding is generally poor, ∼6 %) to its peak at around 1.3‧V cr (where almost 90 % of the particle bonds). Further increase in the velocity to 1.5‧V cr and beyond finds the onset of hydrodynamic penetration and a decrease in bonding. These data then support the development of a simple analytical model based on oxide rarefication and extrusion of bare metal through gaps in the oxide layer as driving the development of bonding. As a result, the model reproduces the experiments and provides guidance on optimization of bonding as a function of material and process parameters.

Analytical methods↗

Nanofabrication of synthetic nanoporous geomaterials: from nanoscale-resolution 3D imaging to nano-3D-printed digital (shale) rock

Abstract Advances in imaging have made it possible to view nanometer and sub-nanometer structures that are either synthesized or that occur naturally. It is believed that fluid dynamic and thermodynamic behavior differ significantly at these scales from the bulk. From a materials perspective, it is important to be able to create complex structures at the nanometer scale, reproducibly, so that the fluid behavior may be studied. New advances in nanoscale-resolution 3D-printing offer opportunities to achieve this goal. In particular, additive manufacturing with two-photon polymerization allows creation of intricate structures. Using this technology, a creation of the first nano-3D-printed digital (shale) rock is reported. In this paper, focused ion beam-scanning electron microscopy (FIB-SEM) nano-tomography image dataset was used to reconstruct a high-resolution digital rock 3D model of a Marcellus Shale rock sample. Porosity of this 3D model has been characterized and its connected/effective pore system has been extracted and nano-3D-printed. The workflow of creating this novel nano-3D-printed digital rock 3D model is described in this paper.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Human NLRP3 inflammasome activation leads to formation of condensate at the microtubule organizing center

The NLRP3 inflammasome is a multiprotein molecular machine that drives inflammatory responses in innate immunity. Although its dysregulation is implicated in numerous human diseases, its structural organization in cells remains poorly understood. Here, we used precise fluorescence-guided cryo–focused ion beam (cryo-FIB) milling and cryo–electron tomography (cryo-ET) to visualize NLRP3 inflammasomes in situ within human macrophages at various stages of activation. After priming and activation, we observed expansion and dispersion of Golgi cisternae, along with the emergence of 50-nanometer NLRP3-associated vesicles, which likely transport NLRP3 to the MTOC. Dense NLRP3-containing condensates then formed in and around the MTOC. In later stages, the condensates solidified, coincident with widespread mitochondrial damage, autophagy, and pyroptotic cell death.

Wang, Jue [Division of Chemistry and Chemical Engi↗

Characterization of Stress-Corrosion-Cracking in Plutonium-Bearing Storage Containers

Introduction • The Integrated Surveillance Program, under the Department of Energy, is responsible for the periodic surveillance of storage containers containing plutonium-bearing materials. • The container-packages are designed to isolate the materials for 50 to 100 years with minimal surveillance. • During monitoring, corrosion-pitting and stress-corrosion-cracking (SCC) has been identified in some of the inner-cans near the weld regions. • SCC through wall penetration would result in an undesired increased risk of leakage. • An investigation is in progress to identify and characterize corrosion events to determine the prevalence of corrosion features and the likelihood of a throughwall breach. • Here, we discuss the characterization efforts carried out by Scanning Electron Microscopy (SEM), including 3D-tomography by Focused Ion Beam (FIB) methods.

Perez, Emmanuel E.↗

New frontiers in atom probe tomography: a review of research enabled by cryo and/or vacuum transfer systems

There has been a recent surge in the use of cryo and/or vacuum specimen preparation and transfer systems that are broadening the scope of research enabled by the microscopy technique of atom probe tomography. This is driven by the fact that, like for many microscopes, the application of atom probe to air and temperature sensitive materials or wet biological specimens has previously been limited by through-air-transfer and through-vacuum-transfer at room temperature. Here we provide an overview of the critical areas of research that require these new transfer and analysis protocols, as well as a review of current advances in transfer devices, environmental cells and glove boxes for controlled sample manipulation. This includes the study of catalysis and corrosion, the application of atom probe to biological samples, the study of liquid-solid interfaces, natural ageing investigations and the analysis of hydrogen in metals.

36 MATERIALS SCIENCE↗

Ternary Potassium‐Bismuth‐Telluride Intermetallic Support Promotes Electrochemical Stability in Potassium Metal Anodes

We employed accumulative roll bonding to fabricate self‐standing metallurgical composite of in situ formed alkaline potassium‐bismuth‐telluride intermetallic K 2 (Bi 2/6 Te 3/6 Vac 1/6 ) embedded in potassium metal. This newly discovered thermodynamically stable potassiophilic crystal, termed “KBT”, is fcc antifluorite with K 2 Te archetype. Symmetric cells achieve 880 h of cycling at 0.5 mA cm −2 and 0.5 mAh cm −2 . Potassium metal battery (KMB) with Prussian blue (PB) cathode in carbonate electrolyte retains 80% capacity after 200 cycles at 1C. In ether‐based electrolyte with organic cathode, it achieves 80% retention after 900 cycles at 2C. Combined synchrotron X‐ray nano‐tomography, cryogenic‐focused ion beam microscopy (Cryo‐FIB) and sputter‐down X‐ray photoelectron spectroscopy (XPS) demonstrate uniform electrodeposits, versus baseline of potassium filaments intermixed with pores and coarse SEI. Binary K 3 Bi‐K and K 2 Te‐K intermetallic supports also provide improved electrochemical performance, albeit to lesser extent. Multiscale simulation provides insight into role of support structure in adatom energetics, film nucleation, early‐stage SEI morphology and interfacial stability.

36 MATERIALS SCIENCE↗

3D imaging techniques for characterising microcracks in cement-based materials

Concrete inherently contains pores and microcracks that can adversely impact its mechanical properties and long-term durability. However, characterising microcracks is difficult due to their complex, multiscale and three-dimensional (3D) nature. This paper presents an evaluation of 3D imaging techniques for characterising microcracks induced by different mechanisms. Seven cement pastes, mortars and concretes subjected to drying shrinkage, autogenous shrinkage and freeze-thaw cycles were investigated using focused ion beam nanotomography (FIB-nt), broad ion beam serial section tomography (BIB-SST), laser scanning confocal microscopy (LSCM) combined with serial sectioning and X-ray microtomography (μCT). The study shows that the characteristics of microcracks vary significantly depending on exposure conditions. Yet there is no single technique that can capture the entire size range of microcracks from sub to tens of μm within a sufficiently representative sampling volume. The achievable image volume and resolution, and the advantages and disadvantages of each technique are compared and discussed.

36 MATERIALS SCIENCE↗

Bridging multimodal microscopy for advanced characterization on nuclear fuel using machine learning

Uranium dioxide (UO 2 ), widely used as driver fuel in light water reactors, experiences microstructure and property change by nuclear fission reactions. This paper bridges the characterization of fresh UO 2 fuel at different length scales, serving as a baseline for future post irradiation examination of irradiated UO 2 fuel. To characterize the microstructural change of nuclear fuel, modern approaches cover a wide range of length scales through different characterization techniques, such as mm scale for Synchrotron-based X-ray computed tomography (SXCT) and microscale for focused ion beam (FIB) and scanning electron microscopy (SEM). It is challenging to bridge the data and knowledge of the same sample in different length scales. This paper proposed a deep learning framework leveraging transfer learning to detect microstructural defects, trained from a sparse FIB, SEM, and SXCT images. The proposed model achieved superior performance in defect segmentation on multiscale microscopic data compared to four of the latest deep learning models.

36 MATERIALS SCIENCE↗

Deciphering the Distribution and Crystal-Chemical Environment of Arsenic, Lead, Silica, Phosphorus, Tin, and Zinc in a Porous Ferrihydrite Grain Using Transmission Electron Microscopy and Atom Probe Tomography

Here the interaction of contaminants and nutrients with soil constituents is controlled by processes in intergranular and intragranular pore spaces of organic matter or/and common secondary minerals such as ferrihydrite, ~Fe 3+ 10 O 14 (OH) 2 . This contribution shows that distribution and clustering of the contaminants As, P, Pb, Si, Sn, and Zn in a porous ferrihydrite grain is greatly affected by the heterogeneous size distribution and chemical composition of the pores as well as the ability of their polyhedra to polymerize with the same type of polyhedron. Transmission electron microscopy (TEM) and atom probe tomography (APT) studies are conducted on focused ion beam (FIB) sections extracted from a porous ferrihydrite grain from the smelter-impacted topsoil in Sudbury, Ontario, Canada. The ferrihydrite grain has pore spaces ranging in diameter from tens to hundreds of nanometers. TEM and scanning-TEM studies indicate that the surfaces of the pore walls are enriched in Si. APT data in conjunction with First Near Neighbor (1NN) analyses indicate different degrees of clustering of Pb, As, Sn, Zn, Si, and P within the sample and selected domains. Careful evaluations of 3D atomic plots and 1NN distances indicates the occurrence of polymerized arsenite-, silica-, Sn-, and Zn-polyhedra within pore spaces of the ferrihydrite. Deciphering adsorption, polymerization, and nucleation processes in porous Fe-(hydr)oxides and other soil constituents requires multianalytical approaches and, in this regard, we discuss the advantages and disadvantages of the combination of TEM and APT for characterizing complex environmental samples at the atomic to nanometer scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical interference for the guidance of cryogenic focused ion beam milling beyond the axial diffraction limit

Cryogenic focused ion beam (Cryo-FIB) milling has become a standard step in the cryogenic electron tomography (Cryo-ET) workflow and is required to thin cells to electron-semitransparency. However, this destructive process removes the vast majority of the cellular material and raises a critical question: what thin section should be preserved for Cryo-ET analysis? Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labeled structures with accuracy beyond the diffraction limit. Here we demonstrate this approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of amorphous ice. We then apply the approach to capture virions inside host cells. Successful targeting is confirmed by Cryo-ET revealing clusters of virions in intracellular vesicles. The method does not require any fluorescent fiducials or axial registration and can be performed on any fluorescently labeled structure that is visible in widefield fluorescence microscopy.

Cryoelectron microscopy↗

Measuring Multicomponent Adsorption of Tracer Gases on Natural Zeolites

A natural clinoptilolite sample near the Nevada National Security Site was obtained to study adsorption and retardation on gas transport. Of interest is understanding the competition for adsorption sites that may reduce tracer gas adsorption relative to single-component measurements, which may be affected by the multi-scale pore structure of clinoptilolite. Clinoptilolite has three distinct domains of pore size distributions ranging from nanometers to micrometers: micropores with 0.4–0.7 nm diameters, measured on powders by CO2 adsorption at 273 K, representing the zeolite cages; mesopores with 4–200 nm diameters, observed using liquid nitrogen adsorption at 77 K; and macropores with 300–1000 nm diameters, measured by mercury injection on rock chips (~ 100 mesh), likely representing the microfractures. These pore size distributions are consistent with X-ray computed tomography (CT) and focused ion beam scanning electron microscope (FIB-SEM) images, which are used to construct the three-dimensional (3D) pore network to be used in future gas transport modeling. To quantify tracer gas adsorption in this multi-scale pore structure and multicomponent gas species environment, natural zeolite samples initially in equilibrium in air were exposed to a mixture of tracer gases. As the tracer gases diffuse and adsorb in the sample, the remaining tracer gases outside the sample fractionate. Using a quadrupole mass spectrometer to quantify this fractionation, the degree of adsorption of tracer gases in the multicomponent gas environment and multi-scale pore structure is assessed. The major finding is that Kr reaches equilibrium much faster than Xe in the presence of ambient air, which leads to more Kr uptake than Xe over limited exposure periods. When the clinoptilolite chips were exposed to humid air, the adsorption capability decreases significantly for both Xe and Kr with relative humidity (RH) as low as 3%. Both Xe and Kr reaches equilibrium faster at higher RH. The different, unexpected, adsorption behavior for Xe and Kr is due to their kinetic diameters similar to the micropores in clinoptilolite which makes it harder for Xe to access compared to Kr.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructural Characterization of AGR-2 TRISO-coated Particle Buffer, IPyC, and Buffer-IPyC Interfaces

Investigating the microstructural, mechanical, and chemical behaviors of Tristructural Isotropic (TRISO) fuel particles is vital for its qualification and use in advanced reactors. Central to the study of TRISO particles is understanding the silicon carbide (SiC) layer's ability to confine fission products, with failure mechanisms linked to chemical degradation following mechanical degradation of the buffer and IPyC layers. Research has been done to quantify the micro-tensile properties of the buffer, inner pyrolytic carbon (IPyC), and buffer-IPyC interlayer regions and their interactions within both irradiated and un-irradiated TRISO particles. Techniques such as atom probe tomography (APT) and transmission electron microscopy (TEM) have also been deployed to examine microstructural defects and fission product distribution in detail. The goal is to understand layer delamination, establish connections between microstructure and mechanical attributes, and inform computational predictions of fuel performance. This work may help refine predictive models of TRISO fuel behavior and facilitating its certification for use in advanced reactors.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-Scale Characterization of Porosity and Cracks in Silicon Carbide Cladding after Transient Reactor Test Facility Irradiation

Silicon carbide (SiC) ceramic matrix composite (CMC) cladding is currently being pursued as one of the leading candidates for accident-tolerant fuel (ATF) cladding for light water reactor applications. The morphology of fabrication defects, including the size and shape of voids, is one of the key challenges that impacts cladding performance and guarantees reactor safety. Therefore, quantification of defects’ size, location, distribution, and leak paths is critical to determining SiC CMC in-core performance. This research aims to provide quantitative insight into the defect’s distribution under multi-scale characterization at different length scales before and after different Transient Reactor Test Facility (TREAT) irradiation tests. A non-destructive multi-scale evaluation of irradiated SiC will help to assess critical microstructural defects from production and/or experimental testing to better understand and predict overall cladding performance. X-ray computed tomography (XCT), a non-destructive, data-rich characterization technique, is combined with lower length scale electronic microscopic characterization, which provides microscale morphology and structural characterization. This paper discusses a fully automatic workflow to detect and analyze SiC-SiC defects using image processing techniques on 3D X-ray images. Following the XCT data analysis, advanced characterizations from focused ion beam (FIB) and transmission electron microscopy (TEM) were conducted to verify the findings from the XCT data, especially quantitative results from local nano-scale TEM 3D tomography data, which were utilized to complement the 3D XCT results. In this work, three SiC samples (two irradiated and one unirradiated) provided by General Atomics are investigated. The irradiated samples were irradiated in a way that was expected to induce cracking, and indeed, the automated workflow developed in this work was able to successfully identify and characterize the defects formation in the irradiated samples while detecting no observed cracking in the unirradiated sample. These results demonstrate the value of automated XCT tools to better understand the damage and damage propagation in SiC-SiC structures for nuclear applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multimodal imaging and machine learning to enhance microscope images of shale

A machine learning based image processing workflow is presented to enhance shale source rock microscopic images obtained using diverse imaging platforms. Images were acquired from a 30 μm diameter cylindrical Vaca Muerta shale sample using both nondestructive Transmission X-Ray Microscopy (TXM, alternately referred to as nano computed tomography) and destructive Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM). Output cross-sectional images from each modality were aligned using a combination of manual and automated registration techniques to create a registered image dataset. We then apply this dataset for two image processing tasks: prediction of image cross sections with SEM-like resolution from nondestructive TXM data and repair of charged region artifacts (localized accumulation of electrons) within SEM images. The image processing algorithms for both tasks use deep learning models, specifically image-to-image Convolutional Neural Networks (CNNs) and conditional Generative Adversarial Networks (cGANs). In the image enhancement tasks, we are able to achieve significant qualitative and quantitative improvement in TXM images. Here, the best model reaches an average Peak Signal to Noise Ratio (PSNR) of 15.8 dB. Conditioning on TXM data is also shown to reduce artifacts from SEM charging, achieving an average PSNR of 25.8 dB. Furthermore, our results suggest that properly trained and validated networks are capable of significant enhancement of images obtained using nondestructive techniques, thereby improving interpretation of two- and three-dimensional images while preserving samples for future use.

58 GEOSCIENCES↗

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

Aggregated nanoparticles: Sample preparation and analysis by atom probe tomography

Atom probe tomography (APT) allows measurement of the three-dimensional structure and composition of materials, but specific sample preparation procedures are required for challenging materials such as aggregates of nanoparticles. Indeed, the presence of porosity within the specimen affects both the stability of the sample and the accuracy of the data. In this work, aggregates of nanoparticles were transferred onto a micromanipulator tip and embedded via electron-beam-assisted deposition of Pt. Successive FIB-millings and Pt-depositions are needed to create suitable APT tips. The 3D reconstruction reveals the presence of 15–20 nm nanoparticles, and massspectral analysis shows the absence of trace elements within the catalyst, thus serving as quality control for the synthesis of nanoparticles with specific compositions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗