Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FGD Effluent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

24 records · Page 2

Energy Efficient Waste Heat Coupled Forward Osmosis for Effluent Water Management at Coal-Fired Power Plants

This project sought to evaluate the technical and economic viability of the Aquapod©, a transformational low energy (<200 kJ/kg water) waste heat coupled forward osmosis (FO) technology, to manage effluents, meet cooling water demands, and achieve water conservation in a coal-fired power plant environment. The Aquapod© process is innovative because it is heat-driven, avoids the evaporation of water, and uses no toxic chemicals such as ammonia or amines. The Aquapod© process accomplishes this using an aqueous two-phase system (ATPS) coupled FO process. The evaluation revealed that the Aquapod© process offers a pathway to exploit waste heat resources within a power plant to achieve flue-gas desulfurization (FGD) wastewater volume reduction and water recovery with minimal pretreatment. Water recovery of 80% from FGD wastewater was achieved with minimal pretreatment, exceeding the project target of 50%. The estimated electrical energy of 2.16 kWh/m 3 of water produced for the Aquapod© process met the project target of < 3.6 kWh/m 3 . The heat required for the process operation was approximately 186 kJ/kg of produced water, which was slightly lower than the project target of 200 kJ/kg. The estimated treatment cost for installing and operating the Aquapod© process in conjunction with a spray dryer evaporator to achieve zero-liquid discharge (ZLD) of the 100 gpm FGD wastewater was $13.24/m 3 over a 30-year lifetime. As a point of reference, this study’s host power plant currently incurs a cost of $3.70/m 3 – $8.87/m3 on a discharged volume basis to discharge its wastewater into the publicly owned treatment works (POTW) after physical-chemical treatment. Therefore, the Illinois power plant would incur an incremental cost increase of $4.37/m 3 – 9.54/m 3 to achieve ZLD using the Aquapod© and spray dryer combination. Ample opportunities exist to further lower the ZLD capital and operating costs in the next design iteration to attain pipe parity at the higher end of the site treatment costs.

01 COAL, LIGNITE, AND PEAT↗

Aqueous Bromide Discharges from U.S. Coal-Fired Power Plants: Points of Origin, Concentration Ranges, and Effluent Treatment Costs

Bromide discharges from coal-fired power plants have received increased attention from regulatory bodies due to their contribution to the formation of disinfection byproducts (DBPs) in downstream drinking water treatment plants. Here, this paper characterizes the relative contributions of bromide from coal feedstocks and bromine-based mercury control processes, estimates the distribution of bromide concentrations at 85 active coal-fired power plants across the United States (U.S.) with wet flue gas desulfurization units, and estimates the cost of bromide removal from wastewater discharge using year 2020 data. Bromide discharges are estimated at the plant level using a combination of the reported coal rank and composition combusted, estimates of bromide addition in mercury control techniques under multiple halogen addition scenarios, and the estimated flue gas desulfurization (FGD) wastewater flow rate. The median, simulated plant-level estimation of total FGD wastewater flow is 18.3 gallons/min at a bromide concentration of 319 mg/L, equivalent to ~11.6 tonnes/year of bromide discharges to the environment. Next, we evaluated the expected cost of employing the best available technology (BAT) to control bromide discharges in FGD wastewater to prevent contributions to DBP formation. Treatment would need to remove more than 99.8% of bromide to reach the 0.2 mg/L voluntary incentive program (VIP) limit. The total cost of treatment depends on whether disposal is on- or off-site; the average costs for all plants combined come to an average of $110 million ($95.2/kgal) in 2021 U.S. dollars for on-site disposal, or $134 million ($115/kgal) for off-site disposal.

01 COAL, LIGNITE, AND PEAT↗

Evaluating the Techno-Economic Feasibility of Forward Osmosis Process Utilizing Low Grade Heat: Applications in Power Plant Water, Wastewater, and Reclaimed Water Treatment

Recovering and using uncoverted heat produced during electric power generation holds potential to significantly improve the efficiency of the electric power industry. One potential use of this low-temperature waste heat is on-site water treatment using waste heat driven processes to comply with the 2015 Effluent Limitation Guidelines for the Steam Electric Generating Sector. Ammonia-carbon dioxide forward osmosis (NH 4 HCO 3 FO) is a two-step waste heat driven process that involves a membrane separation process in which an osmotic pressure gradient created by an NH 4 HCO 3 draw solution is used to pull water across the membrane and a distillation column to regenerate the NH 4 HCO 3 draw solution. In this work we estimate the quantity, quality, and spatio-temporal availability of waste heat produced at U.S. coal, nuclear, and natural gas plants. We combine these estimates of waste heat availability with a techno-economic optimization model of NH 4 HCO 3 FO in order to assess the potential of NH 4 HCO 3 FO to treat flue gas desulfurization (FGD) wastewater, gasification wastewater, and boiler feedwater. We find that in 2012, 18.9 billion GJ of waste heat was discharged from the U.S. coal, natural gas, and nuclear fleet, although only 900 million GJ of waste heat was discharged at temperatures suitable for NH 4 HCO 3 FO. A maximum of 1.9 billion m3/yr of water could be produced using this waste heat to drive a NH 4 HCO 3 FO. The costs of waste heat driven NH 4 HCO 3 FO for FGD and gasification wastewater treatment to zero liquid discharge (ZLD) and boiler feedwater treatment are 2.20-2.40/m 3 and 0.35-0.65/m 3 , respectively. With mechanical vapor compression and crystallization for ZLD wastewater treatment and reverse osmosis for boiler feedwater treatment as the cost benchmark technologies, waste heat driven NH 4 HCO 3 FO is cost competitive for ZLD wastewater treatment, but not boiler feedwater treatment.

20 FOSSIL-FUELED POWER PLANTS↗

Novel Algae Technology for CO2 Utilization

The United States, the world’s largest energy user and second largest CO2 emitter, is heavily dependent on fossil energy. In 2014, U.S. coal burning utilities emitted ~1562 million (MM) tons/year (TPY) of CO2 into the atmosphere, accounting for 76% of the total US power sector emissions1. Hence, reducing the CO2 emission footprint from coal plants is widely viewed as a key element in mitigating global warming. Despite significant interest, implementation of CO2 capture technologies has been constrained by the high capture cost which significantly increases the total cost of electricity. Not only is capturing CO2 with traditional technologies expensive, but generally the CO2 has little value and additional expense must be incurred for sequestration. This project funded by a SBIR grant from the U.S. D.O.E. to Helios-NRG in collaboration with the State University of New York at Buffalo (UB) and Membrane Technology and Research Inc. (MTR) aimed to develop a novel, algae based technology to capture CO2 from the effluent of coal-based power plants and convert it to renewable bio-fuels and higher value co-products such as animal feed and nutraceuticals with the potential to enable a substantial reduction in the net cost of carbon capture. The Phase 2 project was aimed at further demonstrating the technical feasibility of the proposed multi-stage continuous (MSC) flow CO2 capture system and the generation of high-value co-products to offset the CO2 capture cost. The project was completed and the project objectives were met and exceeded. A first-of-a-kind integrated, laboratory scale MSC process unit was fabricated and tested in a greenhouse. The tests were conducted with the preferred algae species identified in Phase I and simulated flue gas containing contaminants at levels typically present in the post flue gas desulfurization (FGD) stream, including ~12% CO2, acid gas (SOX, NOX), and a large number of heavy metals. The tests were successful and demonstrated a 25g/m2/day seasonal average algae productivity and an 80% CO2 capture efficiency. Two new algae species were identified for high-value nutraceutical production. Studies to improve growth rate and nutraceutical content of these algae species were performed and a pathway for further improvements was identified. A new dewatering technology called DeAqua was further advanced. Significant improvement in the performance index was achieved. The anti-fouling membrane was developed and fabricated into a module. The fabricated membrane module was tested with algae slurry and demonstrated improved fouling resistant properties, that can potentially reduce the cost and energy of the critical dewatering step. Test data were used to simulate operation of the overall process. The preliminary economic analysis was updated and modelled based on a 5000-acre algae farm. To the extent possible, the financial and operating assumptions used were the same as those used in the DOE’s 2022 projections for algae technology for CO2 capture and utilization. The results showed the proposed technology’s potential to significantly reduce the cost of CO2 capture compared to current options and that the high value products generated from the CO2 captured can make a step change in the cost of carbon capture. Plans to advance the technology to Phase 2B were developed and potential end-user partners were identified.

Maloney, James↗

An Innovative System for the Efficient and Effective Treatment of Non-Traditional Waters for Reuse in Thermoelectric Power Generation

This study assessed opportunities for improving water quality associated with coal-fired power generation including the use of non-traditional waters for cooling, innovative technology for recovering and reusing water within power plants, novel approaches for the removal of trace inorganic compounds from ash pond effluents, and novel approaches for removing biocides from cooling tower blowdown. This research evaluated specifically designed pilot-scale constructed wetland systems for treatment of targeted constituents in non-traditional waters for reuse in thermoelectric power generation and other purposes. The overall objective of this project was to decrease targeted constituents in non-traditional waters to achieve reuse criteria or discharge limitations established by the National Pollutant Discharge Elimination System (NPDES) and Clean Water Act (CWA). The six original project objectives were completed, and results are presented in this final technical report. These objectives included identification of targeted constituents for treatment in four non-traditional water sources, determination of reuse or discharge criteria for treatment, design of constructed wetland treatment systems for these non-traditional waters, and measurement of treatment of targeted constituents in non-traditional waters, as well as determination of the suitability of the treated non-traditional waters for reuse or discharge to receiving aquatic systems. The four non-traditional waters used to accomplish these objectives were ash basin water, cooling water, flue gas desulfurization (FGD) water, and produced water. The contaminants of concern identified in ash basin waters were arsenic, chromium, copper, mercury, selenium, and zinc. Contaminants of concern in cooling waters included free oxidants (chlorine, bromine, and peroxides), copper, lead, zinc, pH, and total dissolved solids. FGD waters contained contaminants of concern including arsenic, boron, chlorides, selenium, mercury, chemical oxygen demand (COD), and zinc. Similar to FGD waters, produced waters contained contaminants of concern that are predominantly inorganic (arsenic, cadmium, chlorides, chromium, copper, lead, mercury, nickel, sulfide, zinc, total dissolved solids), but also contained some organics (benzene, PAHs, toluene, total organic carbon, total suspended solids, and oil and grease). Constituents of concern that may cause chemical scaling, biofouling and corrosion, such as pH, hardness and ionic strength, and nutrients (P, K, and N) may also be found in all four non-traditional waters. NPDES permits were obtained for these non-traditional waters and these permit limits are summarized in tabular format within this report. These limits were used to establish treatment goals for this research along with toxicity values for Ceriodaphnia dubia, water quality criteria established by the US EPA, irrigation standards established by the United States Department of Agriculture (USDA), and reuse standards focused on minimization of damage to the power plant by treated waters. Constructed wetland treatment systems were designed for each non-traditional water source based on published literature reviews regarding remediation of the constituents of concern, biogeochemistry of the specific contaminants, and previous research. During this study, 4 non-traditional waters, which included ash basin water, cooling water, FGD water and produced water (PW) were obtained or simulated to measure constructed wetland treatment system performance. Based on data collected from FGD experiments, pilot-scale constructed wetland treatment systems can decrease aqueous concentrations of elements of concern (As, B, Hg, N, and Se). Percent removal was specific for each element, including ranges of 40.1% to 77.7% for As, 77.6% to 97.8% for Hg, 43.9% to 88.8% for N, and no measureable removal to 84.6% for Se. Other constituents of interest in final outflow samples should have aqueous characteristics sufficient for discharge, with the exception of chlorides (<2000 mg/L). Based on total dissolved solids, co-management or ion reduction (e.g. reverse osmosis, nanofiltration, ultrafiltration, etc.) techniques will be needed for discharge or reuse of high ionic strength waters. Data collected from produced water experiments indicate that hybrid pilot-scale constructed wetland treatment systems can decrease aqueous concentrations of elements of concern (Zn, Cd, Pb, and Cu). Percent removal was specific for each element, including ranges of 38.4% to 99.6% for Cd, 90.6% to 99.8% for Cu, 93.1% to 99.3% for Pb, and 40.0% to 99.8% for Zn. Reuse of these waters will likely depend on the chloride concentration of the outflow samples, but with use of reverse osmosis technology, chloride concentrations can be decreased sufficiently for reuse as service water. Concentrations of arsenic, selenium, chromium, and zinc were decreased in ash basin waters by pilot-scale constructed wetland treatment systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technoeconomic Optimization of Waste Heat Driven Forward Osmosis for Flue Gas Desulfurization Wastewater Treatment

With the Environmental Protection Agency’s recent Effluent Limitation Guidelines for Steam Electric Generators, power plants are having to install and operate new wastewater technologies. Many plants are evaluating desalination technologies as possible compliance options. However, the desalination technologies under review that can reduce wastewater volume or treat to a zero-liquid discharges standard have a significant energy penalty to the plant. Waste heat, available from the exhaust gas or cooling water from coal-fired power plants, offers an opportunity to drive wastewater treatment using thermal desalination technologies. One such technology is forward osmosis (FO). Forward osmosis utilizes an osmotic pressure gradient to passively pull water from a saline or wastewater stream across a semi-permeable membrane and into a more concentrated draw solution. This diluted draw solution is then fed into a distillation column, where the addition of low temperature waste heat can drive the separation to produce a reconcentrated draw solution and treated water for internal plant reuse. The use of low-temperature waste heat decouples water treatment from electricity production and eliminates the link between reducing water pollution and increasing air emissions from auxiliary electricity generation. In order to evaluate the feasibility of waste heat driven FO, we first build a model of an FO system for flue gas desulfurization (FGD) wastewater treatment at coal-fired power plants. This model includes the FO membrane module, the distillation column for draw solution recovery, and waste heat recovery from the exhaust gas. We then add a costing model to account for capital and operating costs of the forward osmosis system. We use this techno-economic model to optimize waste heat driven FO for the treatment of FGD wastewater. We apply this model to three case studies: the National Energy Technology Laboratory (NETL) 550 MW model coal fired power plant without carbon capture and sequestration, the NETL 550 MW model coal fired power plant with carbon capture and sequestration, and Plant Bowen in Eularhee, Georgia. For each case, we identify the design that minimizes the cost of wastewater treatment given the safely recoverable waste heat. We benchmark the cost minimum waste-heat forward osmosis solutions to two conventional options that rely on electricity, reverse osmosis and mechanical vapor recompression. Furthermore, we quantify the environmental damages from the emissions of carbon dioxide and criteria air pollutants for each treatment option. With this information we can assess the trade-offs between treatment costs, energy consumption, and air emissions between the treatment options.

20 FOSSIL-FUELED POWER PLANTS↗