At least 37 records · Page 2

Development and Experimental Validation of a High-Power DC Distribution Testbed for Advanced Charging Infrastructure and Energy Management

This paper presents the development of a hardware testbed for DC-distributed high-power charging (HPC) stations. As DC distributed solutions emerge as a viable solution to optimize HPC site operations, challenges such as interoperability, protection, and seamless integration of distributed energy resources (DER) persist. These issues underscore the need for a robust testing facility to investigate compliance of available commercial off-the-shelf (COTS) market devices. The developed testbed features a DC-distributed charging hub including a charger, emulated energy storage system (ESS), and site level communication and controller implementation. It facilitates the testing of COTS hardware, charger prototypes, standards validation and site energy management system (SEMS) controllers at rated power. This paper details the development of the charging infrastructure platform, implementation of communication system, validation of different SEMS algorithms, and understanding improvements required for future expansion. Using the developed testbed, interoperability gaps for SEMS implementation with multi-vehicle concurrent charging via a multi-port charger are experimentally observed. Aimed at supporting the transition to large-scale EV charging infrastructure deployment and DER integration, this testbed plays a crucial role in conformity testing of COTS device interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION

Adaptively remeshed multiphysical modeling of resistance forge welding with experimental validation of residual stress fields and measurement processes

Welding processes used in the production of pressure vessels impart residual stresses in the manufactured component. Computational modeling is critical to predicting these residual stress fields and understanding how they interact with notches and flaws to impact pressure vessel durability. Here, in this work, we present a finite element model for a resistance forge weld and validate it using laboratory measurements. Extensive microstructural changes, near-melt temperatures, and large localized deformations along the weld interface pose significant challenges to Lagrangian finite element modeling. The proposed modeling approach overcomes these roadblocks in order to provide a high-fidelity simulation that can predict the residual stress state in the manufactured pressure vessel; a rich microstructural constitutive model accounts for material recrystallization dynamics, a frictional-to-tied contact model is coordinated with the constitutive model to represent interfacial bonding, and adaptive remeshing is employed to alleviate severe mesh distortion. An interrupted-weld approach is applied to the simulation to facilitate comparison to displacement measures. Several techniques are employed for residual stress measurement in order to validate the finite element model: neutron diffraction, the contour method, and the slitting method. Model-measurement comparisons are supplemented with detailed simulations that reflect the configurations of the residual-stress measurement processes themselves. The model results show general agreement with experimental measurements, and we observe some similarities in the features around the weld region. Factors that contribute to model-measurement differences are identified. Finally, we conclude with some discussion of the model development and residual stress measurement strategies, including how to best leverage the efforts put forth here for other weld problems.

36 MATERIALS SCIENCE

Introduction, Investigation, and Experimental Validation of a Novel Passive Neutron Spectrometer

Unfolding neutron energy spectra are instrumental for determining personal health effects and calculating dose received. This area of study is heavily researched, and Lawrence Livermore National Laboratory (LLNL) is investigating a passive neutron spectrometer for the purpose of acquiring the information needed to determine personnel dose in the event of a criticality accident. A part of this investigation is presented in this article through the examination of four experimental detector responses (DRs). These four DRs were acquired in the presence of 252 Cf, AmBe, GODIVA, and National Ignition Facility (NIF) neutron sources. An algorithm developed at LLNL was used to unfold the neutron fluence from each of the four DRs, and subsequently, fluence-to-dose conversion factors provided by the American National Standards Institute were used to calculate dose. Additionally, a multistep unfolding process was developed and employed to calculate the effects of both direct (from the source) and indirect (from room return) neutrons. The average error when unfolding the direct DR was less than 8%. The dose from 252 Cf was predicted with only 8% error. The multistep approach allowed for the identification of the low-energy neutrons in the 252 Cf, AmBe, and NIF DRs.

Nuclear Criticality Safety Program (NCSP)

Computationally guided experimental validation of divacancy defect formation in 4H-SiC

Recent research into solid-state qubits for quantum information science has focused on optically addressable spin defects such as the negatively charged nitrogen-vacancy center in diamond and the neutrally charged divacancy (VV) in 4H-SiC as scalable quantum sensors and networking qubits. Within this context, direct investigations of the structural origin and defect formation dynamics of a sub-set of the VV center in 4H-SiC remain lacking. Here, we take a systematic experimental approach guided by predictions from first-principles simulations to gain a thorough mechanistic understanding of the VV defect formation and control in 4H-SiC. We study the effect of annealing time and temperature on VV formation in high-purity semi-insulating 4H-SiC samples following electron irradiation. Three different temperatures (1123, 1273, and 1473 K) and annealing duration (from 0.5 to 72 h) are chosen to explore VV formation in different regions. We find that samples annealed at 1273 K give the highest VV-related photoluminescence (PL) intensities, in agreement with the prediction from first-principles calculations. Furthermore, the logarithmic dependence of VV-related PL intensities on the annealing duration at 1273 K indicates that 1273 K provides sufficient thermal energy for silicon vacancy migration but not for VV migration. Together, these results suggest that efficient VV formation occurs above the V Si migration temperature and below the VV migration threshold.

74 ATOMIC AND MOLECULAR PHYSICS

Quantitative infrared spectroscopy of aerosols: Mie theory modeling with experimental validation

Infrared spectroscopy is a well-established method for identifying solid, liquid, and gas-phase chemicals. Accurate infrared spectroscopic analysis requires reference libraries where library endmembers reflect all optical phenomena contributing to the observed spectra. Traditional spectral libraries most often contain molecular-based absorption spectra, but these do not account for the complex scattering effects that become significant when measuring aerosols. In this work, we combine the laboratory-derived, wavelength-dependent complex optical vectors ( n / k ) of liquid dioctyl sebacate (DOS) with Mie scattering theory and the Beer–Lambert law to generate synthetic infrared transmission spectra of aerosolized DOS. Additionally, we record experimental infrared transmission spectra using an FTIR spectrometer coupled to a simple aerosol chamber filled with a quantified number size distribution of aerosolized DOS. The modeled and measured spectra show strong agreement, with Mie scattering effects clearly altering the overall spectral shape as well as the positions and profiles of absorption features. The results demonstrate that synthetic spectra generated from n / k values can reliably capture aerosol-specific spectral behavior and thus serve as a foundation for building scalable, physics-based aerosol reference libraries to enable infrared spectroscopic detection of aerosols.

Salcido, Jessica M. O. [Pacific Northwest National

Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering

Physical model and experimental validation of a high temperature proton exchange membrane electrochemical hydrogen pump cell for efficient single-stage extraction of low concentration hydrogen gas

There is interest in valorization of existing natural gas infrastructure to facilitate the co-transportation of hydrogen via blending of hydrogen gas initially at limited concentrations of 1–20 vol% H2 and to subsequently extract hydrogen at fuel cell quality standards (SAE J2719/ISO14687-2). High temperature proton exchange membrane electrochemical hydrogen pump (HT-PEM EHP) based on phosphoric acid doped polybenzimidazole (PA-PBI) exhibits good performance at elevated temperatures (>120 °C), which provides desirable tolerance to non-methane natural gas constituents that are problematic for lower temperature based EHP. To better understand the suitability of the HT-PEM EHP for such gas separation processes, a two-dimensional model of EHP based on PA-PBI was developed. The model is validated for several relevant operating conditions and across cells with differing amounts of phosphoric acid content in the electrodes. Operando micro x-ray computed tomography (CT) imaging of an HT-PEM EHP was used to further validate physical parameters and assumptions of the model. The impacts of pressure, relative humidity of the anode feed, and concentration of feed gases on separation performance are investigated. This study shows that a specific energy of separation of 5.1 kWh/kg H2 at a hydrogen recovery factor (HRF) of 50 vol% can be achieved in a single stage with the EHP, producing fuel cell quality hydrogen purity of 99.99 vol% H2 from a 2 vol% H2/CH4 feed blend, while pressurizing the product H2 at a pressure ratio of 1.3 relative to feed pressure.

Stansberry, John M

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE

Complete coverage fouling model for constant flux crossflow ultrafiltration and experimental validation

A complete coverage model is proposed to describe fouling in constant flux crossflow ultrafiltration. Constant flux crossflow fouling experiments were conducted using dilute latex bead suspensions and commercial poly(ether sulfone) flat sheet ultrafiltration membranes to investigate the influence of operating conditions on evolution of transmembrane pressure (ΔP, TMP) with time. Changes in permeate flux or crossflow rate had little influence on the normalized TMP profile at high latex bead concentration (i.e., above 25 ppm) because the membrane surface was covered with latex beads. At low concentration (i.e., below 25 ppm), increases in permeate flux or foulant concentration increased normalized ΔP. However, this increase in normalized ΔP with permeate flux or foulant concentration diminishes when the permeate flux/concentration is high enough to overwhelm particle removal due to crossflow. Furthermore, these results are in good agreement with the new complete coverage model which describes the influence of operating parameters on fouling better than the previous model.

36 MATERIALS SCIENCE

Circuit Modeling, Simulation, and Experimental Validation of a 100-kW Polyphase Wireless Power Transfer System for EV Applications

Polyphase wireless power transfer (WPT) systems can achieve much higher surface power densities (kW/m2) and specific power levels (kW/kg) compared to the conventional circular single phase WPT systems. Therefore, polyphase WPT systems can reduce the size, weight, volume, and cost of the WPT systems and can simplify the electric vehicle integration with less demand for space. This study presents the high-performance and compact 100-kW WPT development using polyphase electromagnetic coupling coils with rotating magnetic fields.

Onar, Omer [ORNL] (ORCID:0000000292028857)

Experimental Validation of Exact Burst Pressure Solutions for Thick-Walled Cylindrical Pressure Vessels

Burst pressure is one of the critical strength parameters used in the design and operation of pressure vessels because it represents the maximum pressure that a vessel can withstand before failing. Historically, the Barlow formula was used as a design base for estimating burst pressure. However, it does not consider the plastic flow response for ductile steels and is applicable only to thin-walled cylinders (i.e., the diameter to thickness ratio D/t ≥ 20). A new multiaxial plastic yield theory was developed to consider the plastic flow response, and the associated theoretical (i.e., Zhu–Leis) solution of burst pressure was obtained and has gained extensive applications in the pipeline industry because it was validated by different full-scale burst test datasets for large-diameter, thin-walled pipelines in a variety of steel grades from Grade B to X120. The Zhu–Leis flow theory of plasticity was recently extended to thick-walled pressure vessels, and the associated exact flow solution of burst pressure was obtained and is applicable to both thin and thick-walled cylindrical shells. Many full-scale burst tests are available for thin-walled line pipes in the pipeline industry, but limited pressure burst tests exist for thick-walled vessels. To validate the newly developed exact solutions of burst pressure for thick-walled cylinders, this paper conducts a series of burst pressure tests on small-diameter, thick-walled pipes. In particular, six burst tests are carried out for three thick-walled pipes in Grade B carbon steel. These pipes have a nominal diameter of 2.375 inches (60.33 mm) and three nominal wall thicknesses of 0.154, 0.218, and 0.344 inches (3.91, 5.54, and 8.74 mm), leading to D/t = 15.4, 10.9, and 6.9, respectively. With the burst test data, comparisons show that the Zhu–Leis flow solution of burst pressure matches well the burst test data for thick-walled pipes. Thus, these burst tests validate the accuracy of the Zhu–Leis flow solution of burst pressure for thick-walled cylindrical vessels.

42 ENGINEERING

System and Machine Learning-Guided Materials Design for High-Pressure Hydrogen Compression

Cost-effective and reliable hydrogen compression remains a challenging barrier in the widespread adoption of hydrogen as an energy carrier. The prevailing technology of mechanical compression suffers from several drawbacks, some of which can be addressed by nonmechanical compression strategies (e.g., electrochemical or metal hydride-based thermal compression). Thermally driven metal hydride compression strategies typically rely on multistage metal hydride-based compressors; however, discovering or optimizing low-stability metal hydrides that can pressurize hydrogen upward of 1000 bar is difficult, both with respect to computational predictions and experimental validation. Here, in this study, we (1) demonstrate that simple machine learning-derived design rules can inform the rational design of alloying strategies yielding low-stability hydrides, (2) validate their experimental pressure–composition–temperature (PCT) isotherms up to 875 bar, and (3) utilize a dynamic system-level model of a metal hydride compressor design to evaluate their performance under realistic operating conditions. Importantly, this analysis yields predicted operational efficiencies of both 2-stage (90–875 bar) and 3-stage (20–875 bar) metal hydride compressors to enable further evaluation of this technology and its techno-economic outlook.

alloy optimization

Advancing understanding and predictive capability for fast-ion driven instabilities and associated anomalous transport in NSTX-U

This project advanced predictive capability for the spherical tokamak (ST) by (a) experimental validation of physics models in GTC for simulating fast-ion driven instabilities and their fast-ion and energy transport in the ST, and (b) verification of GTC with linear theory and validation using experimental measurements in the high frequency regime in the ST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY