Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Experimental testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Experimental testing of prototype face gears for helicopter transmissions

An experimental program to test the feasibility of using face gears in a high-speed and high-power environment was conducted. Four face gear sets were tested, two sets at a time, in a closed-loop test stand at pinion rotational speeds to 19,100 rpm and to 271 kW. The test gear sets were one-half scale of the helicopter design gear set. Testing the gears at one-eighth power, the test gear set had slightly increased bending and compressive stresses when compared to the full scale design. The tests were performed in the LeRC spiral bevel gear test facility. All four sets of gears successfully ran at 100 percent of design torque and speed for 30 million pinion cycles, and two sets successfully ran at 200 percent of torque for an additional 30 million pinion cycles. The results, although limited, demonstrated the feasibility of using face gears for high-speed, high-load applications.

Handschuh, R.

Evaluation of CFD as a Surrogate for Wind Tunnel Testing - Experimental Uncertainty Quantification

A series of wind tunnel tests is being performed at the Unitary Plan Wind Tunnel at Langley Research Center to assess the validity of using computational fluid dynamics (CFD) as a surrogate for wind tunnel testing. In order to make proper comparisons, uncertainties in CFD results and experimental data must be well understood. The material presented will highlight the methods, assumptions, and elemental inputs used to achieve experimental uncertainty estimates for several variables of interest.The work performed to date has focused on gaining insight into random uncertainty via statistical analysis of repeat data and systematic uncertainty via Monte Carlo propagation analysis. These methods were combined using a second-order Monte Carlo propagation, resulting in a probability box (P-box) for each variable and at all conditions of interest. Figure 1 provides an example of one such P-box, showing the experimental uncertainty in a locally determined dynamic pressure (QC10) for one of many tunnel conditions evaluated during the Flow Survey experiment. This particular condition (Condition 27) has nominal set points of Mach number = 3.85, Reynolds number = 3x10(exp 6) ft(exp -1), total pressure = 5160 psfa, and total temperature = 150°F. The uncertainty in dynamic pressure at this condition is now well defined by this plot. Armed with this experimental data uncertainty, meaningful comparisons can be made with computational results, when their associated uncertainties are also considered.

Heather P Houlden

Experimental test program for evaluation of solid lubricant coating as applied to compliant foil gas bearings to 315 deg C

An experimental apparatus and test procedure was developed to compare the performance of two solid lubricant coatings for air lubricated compliant foil gas bearings in the temperature range of 25 to 315 C. Polyimide bonded additive (SBGC) were tested extensively for durability and frictional characteristics. A partial arc bearing constructed of Inconel X-750 was coated on the bore with one of these coatings. The foil was subjected to repeated start/stop cycles. Performance comparisons reveal that although both coatings survive thousands of start/stop cycles, only the PBGF coated bearing achieves the specified 9000 start/stops. There is enough wear on the SBGC coated bearing to warrant termination of the test prior to 9000 start/stop cycles due to coating failure. The frictional characteristics of the PBGF are better at the elevated temperatures than at lower temperatures; a marked increase in sliding friction occurs as the temperature decreases. The SBGC maintains relatively constant frictional characteristics independent of operating temperature.

Wagner, R. C.

Space QUEST Mission Proposal: Experimentally Testing Decoherence Due to Gravity

Models of quantum systems on curved space-times lack sufficient experimental verification. Some speculative theories suggest that quantum properties, such as entanglement, may exhibit entirely different behavior to purely classical systems. By measuring this effect or lack thereof, we can test the hypotheses behind several such models. For instance, as predicted by Ralph and coworkers [T C Ralph, G J Milburn, and T Downes, Phys. Rev. A, 79(2):22121, 2009; T C Ralph and J Pienaar, New Journal of Physics, 16(8):85008, 2014], a bipartite entangled system could decohere if each particle traversed through a different gravitational field gradient. We propose to study this effect in a ground to space uplink scenario. We extend the above theoretical predictions of Ralph and coworkers and discuss the scientific consequences of detecting/failing to detect the predicted gravitational decoherence. We present a detailed mission design of the European Space Agency's (ESA) Space QUEST (Space - Quantum Entanglement Space Test) mission, and study the feasibility of the mission schema.

Entanglement

Oxygen extraction from lunar materials - An experimental test of an ilmenite reduction process

The reaction of ilmenite with hydrogen to produce water has been studied experimentally in order to evaluate the effectiveness of using a cold trap to improve yields in a continuous flow process. Yields were enhanced, but not to the degree observed in batch processing systems. The terrestrial simulant used in these studies contained traces of iron sulfide, which released H2S during processing with a deleterious effect on several components of the test system. More sophisticated testing should be undertaken to obtain kinetic data and attention given to the removal of sulfides in the pre-process beneficiation.

Williams, R. J.

DGEN Aeropropulsion Research Turbofan Source-Diagnostic Test: Experimental Setup and Acoustic-Data Structure

The experimental setup of, and available data from a recent core/combustor-noise source-diagnostic test utilizing a small turbofan engine are described. The 2019 test campaign continued the investigation of the core/combustor-noise component of aircraft-propulsor noise begun in an earlier baseline test, but with a more extensive acoustic-instrumentation layout. The purpose of both tests was to better understand the impact on civilian-transport airport-community noise from turbofan-combustor sources and thereby to lay the foundation for improved noise-prediction methods and noise-mitigation techniques. Simultaneous high-data-rate acoustic measurements were obtained using a circumferential sensor array at the core nozzle exit in conjunction with sideline and farfield microphone arrays. The test matrix contained engine operational points from engine idle to maximum power and was repeated for different circumferential and sideline array configurations, as well as for redundancy. The extensive data set (up to 93 channels of data and various configurations) allows the application of advanced source-separation and phased-array methods to elucidate not only the core-noise structure, but also the propagation characteristics of other propulsion noise sources. The present report provides a detailed description of the different test points, their associated instrumentation layouts, and the structure of the acquired data set. Results from various data analyses are reported separately.

Aeroacoustics

Experimental Testing of Advanced Generalized Predictive Control for Stability Augmentation and Vibration Reduction of Tiltrotor Aircraft

Generalized Predictive Control (GPC) is an advanced form of an adaptive control algorithm that uses experimentally acquired data to determine the input-output relationship of complex systems through a process called system identification (system ID). GPC has historically been applied to wind tunnel tests of dynamically-scaled tiltrotor aircraft for stability augmentation and vibration reduction since the complex nature of these dynamic systems does not lend itself well to traditional control theory. Advanced GPC (AGPC) improves upon traditional GPC by enabling self-adaptation as conditions change from those used to acquire the system ID and controller performance would normally erode. The present research expands upon previous analytical development and demonstration of AGPC with experimental demonstration. To support AGPC, this present work also identifies and describes figures of merit that define a good working controller and quantifies the uniqueness of the control inputs and quality of the system ID parameters. The present research demonstrates that AGPC consistently performs better than traditional GPC and can successfully adapt to changing conditions.

Active Controls

Experimental Testing of Advanced Generalized Predictive Control for Stability Augmentation and Vibration Reduction of Tiltrotor Aircraft

Generalized Predictive Control (GPC) is an advanced form of an adaptive control algorithm that uses experimentally acquired data to determine the input-output relationship of complex systems through a process called system identification (system ID). GPC has historically been applied to wind tunnel tests of dynamically-scaled tiltrotor aircraft for stability augmentation and vibration reduction since the complex nature of these dynamic systems does not lend itself well to traditional control theory. Advanced GPC (AGPC) improves upon traditional GPC by enabling self-adaptation as conditions change from those used to acquire the system ID and controller performance would normally erode. The present research expands upon previous analytical development and demonstration of AGPC with experimental demonstration. To support AGPC, this present work also identifies and describes figures of merit that define a good working controller and quantifies the uniqueness of the control inputs and quality of the system ID parameters. The present research demonstrates that AGPC consistently performs better than traditional GPC and can successfully adapt to changing conditions.

Active Controls

Experimental Test Results of Energy Efficient Transport (EET) High-Lift Airfoil in Langley Low-Turbulence Pressure Tunnel

This report describes the results of an experimental study conducted in the Langley Low-Turbulence Pressure Tunnel to determine the effects of Reynolds number and Mach number on the two-dimensional aerodynamic performance of the Langley Energy Efficient Transport (EET) High-Lift Airfoil. The high-lift airfoil was a supercritical-type airfoil with a thickness-to- chord ratio of 0.12 and was equipped with a leading-edge slat and a double-slotted trailing-edge flap. The leading-edge slat could be deflected -30 deg, -40 deg, -50 deg, and -60 deg, and the trailing-edge flaps could be deflected to 15 deg, 30 deg, 45 deg, and 60 deg. The gaps and overlaps for the slat and flaps were fixed at each deflection resulting in 16 different configurations. All 16 configurations were tested through a Reynolds number range of 2.5 to 18 million at a Mach number of 0.20. Selected configurations were also tested through a Mach number range of 0.10 to 0.35. The plotted and tabulated force, moment, and pressure data are available on the CD-ROM supplement L-18221.

Morgan, Harry L., Jr.

Experimental testing using a remotely operated flap with a 2D high lift model

The problem of efficient wind tunnel testing for multi-element airfoils was first addressed by the author during a previous ASEE fellowship. A modern three element model with internal actuators to position a flap in two degrees of freedom was designed and later built. Some preliminary testing proved that the approach was viable. The purpose of this summer's work was to fully develop experimental methods including efficient data acquisition. The final goal is to develop dense data sets for both lift and drag measurements as a function of flap position for both take-off and landing configurations. The model has a span of 36 in. and chord of 18 in. and is currently being fitted for a 3 ft. x 4 ft. low speed wind tunnel. The flap was reworked to allow all pressure taps to function after initial tests showed two blocked ports. The serial method of obtaining pressures from the surface taps was found to be exceedingly slow so a new method using 12 pressure transducers and a 12 port parallel scanning valve were developed. A new automated data acquisition and control algorithm was developed using LabView software and a PC platform. Flow two-dimensionality is currently under investigation with boundary layer control by blowing; this was previously omitted for initial testing. By the end of the summer a detailed data set (uncorrected) consisting of lift coefficient versus flap position for the landing configuration should be available.

Landman, Drew

Experimental Test Results of Energy Efficient Transport (ETT) High-Lift Airfoil in Langley Low-Turbulence Pressure Tunnel-Supplement

This report describes the results of an experimental study conducted in the Langley Low-Turbulence Pressure Tunnel to determine the effects of Reynolds number and Mach number on the two-dimensional aerodynamic performance of the Langley Energy Efficient Transport (EET) High-Lift Airfoil. The high-lift airfoil was a supercritical-type airfoil with a thickness-to-chord ratio of 0.12 and was equipped with a leading-edge slat and a double-slotted trailing-edge flap. The leading-edge slat could be deflected 30deg, 40deg, 50deg, and 60deg, and the trailing-edge flaps could be deflected to 15deg, 30deg, 45deg, and 60deg. The gaps and overlaps for the slat and flaps were fixed at each deflection resulting in 16 different configurations. All 16 configurations were tested through a Reynolds number range of 2.5 to 18 million at a Mach number of 0.20. Selected configurations were also tested through a Mach number range of 0.10 to 0.35. The plotted and tabulated force, moment, and pressure data are available on the CD-ROM supplement L-18221.

Morgan, Harry L., Jr.

Analysis and Experimental Tests of a High-Performance Evacuated Tubular Collector

A high-performance collector based on the use of all-glass, evacuated tubular collector elements is described and analyzed, and supporting experimental data presented. The collector operated with excellent efficiency at temperatures high enough to drive existing air conditioning units, and showed good performance under diffuse light and low insolation conditions. Collector efficiency was insensitive to operating temperature, ambient temperature, and wind speed. In addition, air, as well as liquid, can be used as the heat transfer fluid, with no significant performance penalty. While the equations governing the useful energy produced can be cast in a form similar to that for flat plate collectors, several important parameters were unique in a number of respects. The loss coefficient was unusually low, while the flow factor and effective insolation were unusually high.

Beekley, D. C.

A Selection of Experimental Test Cases for the Validation of CFD Codes, Volume 2

This report presents the results of a study by Working Group 14 of the AGARD Fluid Dynamics Panel. The thirty nine test cases that are documented cover the subsonic, transonic, and supersonic flow regimes and five classes of geometries. Included in the five classes of geometries are: Two Dimensional Airfoils; Three Dimensional Wings, designed for predominantly attached flow conditions; Slender Bodies, typical of missile type configurations; Delta Wings, characterized by a conical type of vortex flow; and Complex Configurations, either in a geometrical sense or because of complicated flow interactions. The report is presented in two volumes. Volume 1 provides a review of the theoretical and experimental requirements, a general introduction, summary of the test cases and recommendations for the future. Volume 2 contains detailed information on the test cases.

Advisory Group for Aerospace Research and Developm

Synthetic aperture radar images of ocean waves, theories of imaging physics and experimental tests

The physical mechanism for the synthetic Aperture Radar (SAR) imaging of ocean waves is investigated through the use of analytical models. The models are tested by comparison with data sets from the SEASAT mission and airborne SAR's. Dominant ocean wavelengths from SAR estimates are biased towards longer wavelengths. The quasispecular scattering mechanism agrees with experimental data. The Doppler shift for ship wakes is that of the mean sea surface.

Vesecky, J. F.

Space Launch System Base Heating Test: Experimental Operations & Results

NASA's Space Launch System (SLS) uses four clustered liquid rocket engines along with two solid rocket boosters. The interaction between all six rocket exhaust plumes will produce a complex and severe thermal environment in the base of the vehicle. This work focuses on a recent 2% scale, hot-fire SLS base heating test. These base heating tests are short-duration tests executed with chamber pressures near the full-scale values with gaseous hydrogen/oxygen engines and RSRMV analogous solid propellant motors. The LENS II shock tunnel/Ludwieg tube tunnel was used at or near flight duplicated conditions up to Mach 5. Model development was based on the Space Shuttle base heating tests with several improvements including doubling of the maximum chamber pressures and duplication of freestream conditions. Test methodology and conditions are presented, and base heating results from 76 runs are reported in non-dimensional form. Regions of high heating are identified and comparisons of various configuration and conditions are highlighted. Base pressure and radiometer results are also reported.

Dufrene, Aaron

Suits reflectance models for wheat and cotton - Theoretical and experimental tests

Plant canopy reflectance models developed by Suits are tested for cotton and Penjamo winter wheat. Properties of the models are discussed, and the concept of model depth is developed. The models' predicted exchange symmetry for specular irradiance with respect to sun polar angle and observer polar angle agreed with field data for cotton and wheat. Model calculations and experimental data for wheat reflectance vs sun angle disagreed. Specular reflectance from 0.50 to 1.10 micron shows fair agreement between the model and wheat measurements. An Appendix includes the physical and optical parameters for wheat necessary to apply Suits' models.

Chance, J. E.

Experimental test of magnetospheric models.

The barium cloud injection deep into the magnetosphere of Sept. 21, 1971, has revealed that the quiet-time near-equatorial nightside magnetic field is significantly different from that predicted by existing quite-time models. The influence of currents flowing on or near the geomagnetic equator gives the field a more tail-like structure at a distance as close as 5 earth radii. Several models have been tried out to obtain a best fit to the experimental observations of the shape of the field-aligned ion cloud. Although this method does not lead to a unique solution, the most acceptable option emerging from this analysis is a quiet-time tilted image-dipole model with a Williams-Mead tail field and a disclike ring current on the geomagnetic equator.

Barish, F. D.

Development and experimental test of an analytical model of the orifice pulse tube refrigerator

An analytical model for the orifice pulse tube is developed, in which the system is described in terms of average enthalpy flow with such simplifying assumptions as an ideal gas and sinusoidal pressure variation. Phasor analysis is used to represent temperature, pressure, and mass-flow rate waves in vector form. The model predictions, namely, that the refrigeration power of a pulse-tube refrigerator is proportional to the average pressure, the pulse frequency, the mass-flow ratio, and the square of the dynamic pressure ratio, were verified by experimental measurements. It was found that, as a result of the simplifying assumptions, the magnitudes of the refrigeration power predicted by the model were between three and five times greater than experimental values.

Storch, Peter J.