Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Experimental test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article - Status Report FY20 Q2

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (like a redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed, most primary component have been fabricated, primary components are being assembled in preparation for initial testing, and procurement is continuing with the secondary system components. Since the FY19 THETA status report, The THETA primary system components are at Argonne National Laboratory (ANL) and have been dry assembled. The secondary sodium system for heat rejection from intermediate heat exchanger has all been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger has been procured.

42 ENGINEERING↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2022 Final Report

The Thermal Hydraulic Experimental Test Article (THETA) is a METL vessel experiment designed for testing and validating sodium fast reactor components and phenomena. THETA has been scaled using a non-dimensional Richardson number approach to represent temperature distributions during nominal and loss of flow conditions in a sodium fast reactor (SFR), this analysis was detailed in the THETA FY19 report. The facility is being constructed with versatility in mind, allowing for the installation of various immersion heaters, heat pipes, and heat exchangers without significant facility modification. THETA was designed in collaboration with systems code experts to inform the geometry and sensor placement to acquire the highest value code validation data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article: Second Year of Testing with Secondary Sodium System (Fiscal Year 2025 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is currently installed in the Mechanisms Engineering Test Loop (METL) 28” test vessel #4. Both the primary and secondary sodium systems remain online to facilitate continued testing. This fiscal year, work was performed using a COMSOL Multiphysics magnetohydrodynamic model to characterize flow more accurately in the secondary electromagnetic flowmeters. Experimental campaigns were then performed to study the thermal hydraulic differences between sodium and water as a surrogate fluid in the THETA geometry as well as a study to better characterize and understand temperature oscillations that exist at the outlet of the core to the hot pool. A peer-reviewed article was published in the ASME Journal of Nuclear Engineering and Radiation Science detailing the THETA facility and providing an overview of a test that was performed with the primary and secondary system online [1]. Work continues to develop a database to house experimental THETA data to better facilitate collaboration with industry and laboratory partners for their use of the data for code benchmarking/validation. THETA remains fully operational and is positioned for continued testing in fiscal year 2026.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CSI Flight Computer System and experimental test results

This paper describes the CSI Computer System (CCS) and the experimental tests performed to validate its functionality. This system is comprised of two major components: the space flight qualified Excitation and Damping Subsystem (EDS) which performs controls calculations; and the Remote Interface Unit (RIU) which is used for data acquisition, transmission, and filtering. The flight-like RIU is the interface between the EDS and the sensors and actuators positioned on the particular structure under control. The EDS and RIU communicate over the MIL-STD-1553B, a space flight qualified bus. To test the CCS under realistic conditions, it was connected to the Phase-0 CSI Evolutionary Model (CEM) at NASA Langley Research Center. The following schematic shows how the CCS is connected to the CEM. Various tests were performed which validated the ability of the system to perform control/structures experiments.

Sparks, Dean W., Jr.↗

Evaluation of CFD as a Surrogate for Wind-Tunnel Testing: Experimental Uncertainty Quantification for the UPWT Flow Survey Test

A series of wind tunnel tests are being performed at the Unitary Plan Wind Tunnel (UPWT)at NASA Langley Research Center to assess the validity of using computational fluid dynamics(CFD) as a surrogate for wind tunnel testing. In order to make proper comparisons, uncertainties in CFD results and experimental data must be well understood. The material presented highlights the methods, assumptions, and inputs used to achieve experimental uncertainty estimates. Results for a small subset of tunnel conditions and variables of interest from the first test in the series, the Flow Survey Test, are highlighted and sample CFD comparisons are shown. The bulk of the results from this work are used for comparisons in other AIAA conference papers related to this test series.

Erin P Hubbard↗

Experimental Testing and Modeling of a Pneumatic Regolith Delivery System for ISRU

Excavating and transporting planetary regolith are examples of surface activities that may occur during a future space exploration mission to a planetary body. Regolith, whether it is collected on the Moon, Mars or even an asteroid, consists of granular minerals, some of which have been identified to be viable resources that can be mined and processed chemically to extract useful by-products, such as oxygen, water, and various metals and metal alloys. Even the depleted "waste" material from such chemical processes may be utilized later in the construction of landing pads and protective structures at the site of a planetary base. One reason for excavating and conveying planetary regolith is to deliver raw regolith material to in-situ resource utilization (ISRU) systems. The goal of ISRU is to provide expendable supplies and materials at the planetary destination, if possible. An in-situ capability of producing mission-critical substances such as oxygen will help to extend the mission and its success, and will greatly lower the overall cost of a mission by either eliminating, or significantly reducing, the need to transport the same expendable materials from the Earth. In order to support the goals and objectives of present and future ISRU projects, NASA seeks technology advancements in the areas of regolith conveying. Such systems must be effective, efficient and provide reliable performance over long durations while being exposed to the harsh environments found on planetary surfaces. These conditions include contact with very abrasive regolith particulates, exposure to high vacuum or dry (partial) atmospheres, wide variations in temperature, reduced gravity, and exposure to space radiation. Regolith conveying techniques that combine reduced failure modes and low energy consumption with high material transfer rates will provide significant value for future space exploration missions to the surfaces of the moon, Mars and asteroids. Pneumatic regolith conveying has demonstrated itself to be a viable delivery system through testing under terrestrial and reduced gravity conditions in recent years. Modeling and experimental testing have been conducted at NASA Kennedy Space Center to study and advance pneumatic planetary regolith delivery systems in support of NASA's ISRU project. The goal of this work is to use the model to predict solid-gas flow patterns in reduced gravity environments for ISRU inlet gas line allowing the eductor inlet gas flow to vary and depend on the flow pattern developed at the eductor as inferred by the experimental observations.

Santiago-Maldonado, Edgardo↗

Critical assessment of precracked specimen configuration and experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate

A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.

Domack, M. S.↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Comparison of thermal analytic model with experimental test results for 30-sentimeter-diameter engineering model mercury ion thruster

A thermal analytic model for a 30-cm engineering model mercury-ion thruster was developed and calibrated using the experimental test results of tests of a pre-engineering model 30-cm thruster. A series of tests, performed later, simulated a wide range of thermal environments on an operating 30-cm engineering model thruster, which was instrumented to measure the temperature distribution within it. The modified analytic model is described and analytic and experimental results compared for various operating conditions. Based on the comparisons, it is concluded that the analytic model can be used as a preliminary design tool to predict thruster steady-state temperature distributions for stage and mission studies and to define the thermal interface bewteen the thruster and other elements of a spacecraft.

Oglebay, J. C.↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications: Preprint

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900 MHz LTE network↗