Heart rate dynamics during long-term space flight: report on Mir cosmonauts
No abstract available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract available
Rats exposed to head-down suspension (HDS) exhibit reductions in maximal O2 consumption (VO2max) and atrophy of select hindlimb muscles. This study tested the hypothesis that an endocrine-deficient rat exposed to HDS would not exhibit reductions in VO2max or hindlimb muscle mass. Hypophysectomized (HYPX) and sham-operated (SHAM) rats were tested for VO2max before and after 28 days of HDS or cage control (CC) conditions. No significant reductions in VO2max were observed in HYPX rats. In contrast, SHAM-HDS rats exhibited a significant reduction in absolute (-16%) and relative (-29%) measures of aerobic capacity. Time course experiments revealed a reduction in VO2max in SHAM-HDS rats within 7 days, suggesting that cardiovascular adjustments to HDS occurred in the 1st wk. HDS was associated with atrophy of the soleus (-42%) in SHAM rats, whereas HYPX rats exhibited atrophy of the soleus (-36%) and plantaris (-13%). SHAM-HDS rats had significantly lower (-38%) soleus citrate synthase activities per gram muscle mass than SHAM-CC, but no significant differences existed between HYPX-HDS and -CC rats. HDS rats had an impaired ability to thermoregulate, as indicated by significantly greater temperature increases per unit run time, compared with their CC counterparts. Pretreatment plasma epinephrine levels were significantly lower in HYPX than in SHAM rats. Norepinephrine concentration was similar for all groups except HYPX-HDS, in which it was significantly higher. HDS had no significant effect on thyroxine or triiodothyronine. SHAM-HDS rats had significantly lower concentrations of testosterone and growth hormone.(ABSTRACT TRUNCATED AT 250 WORDS).
The dynamics of change in plasma volume (PV) and baroreflex responses have been reported over 24 h immediately following maximal cycle exercise. The purpose of this study was to determine if PV and baroreflex showed similar changes for 24 h after resistance exercise. Eight men were studied on 2 test days, 1 week apart. On 1 day, per cent change (% delta) in PV was estimated at 0,3, and 6 h after resistance exercise using haematocrit and haemoglobin. Baseline PV was measured 24 h after exercise using Evans blue dye. The carotid baroreceptor-cardiac reflex response was measured before, and 3, 6, 9, 12, and 24 h post-exercise. Each subject performed six sets of the bench press and leg press with 10 repetitions per set with a load that induced failure within each set. On a control day, the protocol was used without exercise. Plasma volume did not change during the control day. There was a 20% decrease in PV immediately post-exercise; the recovery of the PV was rapid and complete within 3 h. PV was 20% greater 24 h post-exercise than on the control day. There were no differences in any of the baroreflex measurements. Therefore, it is suggested that PV shifts may occur without altering baroreflex sensitivity.
The purpose of this study was to compare the effects of two different recovery modes from hind-limb suspension-induced hypodynamia on whole body and muscle (soleus) growth as well as soleus composition and size changes of different fiber types within this same muscle. Following 28 days of tail-suspension, rats were returned to their cages and sedentarily recovered (HS), or were exercised by running on a treadmill 5 days/wk, at progressively increasing workloads (HR) for one month. Sedentary and running control groups of animals (CS, CR) were also evaluated for comparative purposes. The exercise program, which was identical for CR and HR groups, had no effect on body wt., soleus wt., soleus muscle composition or fiber size in CR rats. Atrophied soleus muscle and reduced soleus wt./body wt. ratio (both 60% of control) had returned to control values by day 7 of recovery in both suspended groups despite the fact that whole body wt. gain was significantly reduced (p less than 0.05) in HR as compared to HS rats. Atrophied soleus Type I fiber mean cross-sectional area in both HR and HS groups demonstrated similar and significant (p less than 0.01) increases during recovery. Increases in Type IIa and IIc fiber area during this same period were significant only in the HR group. While the percentage area of muscle composed of Type I fibers increased in both hypodynamic groups during recovery, the reduction in area percentage of muscle made up of Type IIa fibers was again only significant in the HR group.(ABSTRACT TRUNCATED AT 250 WORDS).
The aim of this study was to compare the effectiveness of different cooling regime intensities to maintain physiological and subjective comfort during physical exertion levels comparable to that engaged in during extravehicular activities (EVA) in space. We studied eight subjects (six males, two females) donned in our newly developed physiologically based shortened liquid cooling/warming garment (SLCWG). Rigorous (condition 1) and mild (condition 2) water temperature cooling regimes were compared at physical exertion levels comparable to that performed during EVA to ascertain the effectiveness of a lesser intensity of cooling in maintaining thermal comfort, thus reducing energy consumption in the portable life support system. Exercise intensity was varied across stages of the session. Finger temperature, rectal temperature, and subjective perception of overall body and hand comfort were assessed. Finger temperature was significantly higher in the rigorous cooling condition and showed a consistent increase across exercise stages, likely due to the restriction of heat extraction because of the intensive cold. In the mild cooling condition, finger temperature exhibited an overall decline with cooling, indicating greater heat extraction from the body. Rectal temperature was not significantly different between conditions, and showed a steady increase over exercise stages in both rigorous and mild cooling conditions. Ratings of overall comfort were 30% higher (more positive) and more stable in mild cooling (p<0.001). The mild cooling regime was more effective than rigorous cooling in allowing the process of heat exchange to occur, thus maintaining thermal homeostasis and subjective comfort during physical exertion.