At least 37 records · Page 2

Experiments to Quantify the Shielding Efficacy of Materials to be Implemented for Portable Shielding Enclosures that Adequately Mitigate EMI from Lighting Attachment Events

Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling” regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of ~33 kA and a risetime of 1.4 μs is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Projection-Based Model Reduction for Coupled Conduction—Enclosure Radiation Systems

We report a projection-based reduced order model (pROM) methodology has been developed for transient heat transfer problems involving coupled conduction and enclosure radiation. The approach was demonstrated on two test problems of varying complexity. The reduced order models demonstrated substantial speedups (up to 185×) relative to the full order model with good accuracy (less than 3% L ∞ error). An attractive feature of pROMs is that there is a natural error indicator for the ROM solution: the final residual norm at each time-step of the converged ROM solution. Using example test cases, we discuss how to interpret this error indicator to assess the accuracy of the ROM solution. The approach shows promise for many-query applications, such as uncertainty quantification and optimization. The reduced computational cost of the ROM relative to the full-order model (FOM) can enable the analysis of larger and more complex systems as well as the exploration of larger parameter spaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Disentangling Beam Losses in The Fermilab Main Injector Enclosure Using Real-Time Edge AI

The Fermilab Main Injector enclosure houses two accelerators, the Main Injector and Recycler Ring. During normal operation, high intensity proton beams exist simultaneously in both. The two accelerators share the same beam loss monitors (BLM) and monitoring system. Deciphering the origin of any of the 260 BLM readings is often difficult. The (Accelerator) Real-time Edge AI for Distributed Systems project, or READS, has developed an AI/ML model, and implemented it on fast FPGA hardware, that disentangles mixed beam losses and attributes probabilities to each BLM as to which machine(s) the loss originated from in real-time. The model inferences are then streamed to the Fermilab accelerator controls network (ACNET) where they are available for operators and experts alike to aid in tuning the machines.

43 PARTICLE ACCELERATORS↗

Advanced Coolant Enclosure Solutions for Micro Gas Cooled Reactors with Enhanced Efficiency and Safety

Argonne’s advanced high-pressure, high-temperature gas enclosures solutions were developed and tested for Light Water Reactor (LWR) fuel applications wherein pressure, temperature, fuel and working fluid are substantially different when compared to the operating conditions typical of gas cooled reactors (GCR). For LWR applications the coolant sleeve pressure exerted on the inner and outer walls of the sleeve may be equalized by pressurizing the fuel rod (e.g., with helium gas) to compensate for the coolant high pressure exerted on the outer walls of the sleeve. This results in a lower differential pressure. Micro-GCRs are reactor systems operated at elevated temperatures and pressure with gas as a working fluid. HolosGen’s Holos-Quad represent a type of Micro-GCR wherein the core is sleeved to segregate the fuel and other components from the working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact resistant battery enclosure systems

Battery enclosure arrangements for a vehicular battery system. The arrangements, capable of impact resistance include plurality of battery cells and a plurality of kinetic energy absorbing elements. The arrangements further include a frame configured to encase the plurality of the kinetic energy absorbing elements and the battery cells. In some arrangements the frame and/or the kinetic energy absorbing elements can be made of topologically interlocked materials.

Tsutsui, Waterloo↗

MAT 332: Recyclable-By-Design Carbon Fiber Composites for Battery Enclosures

This work aims to fabricate a small-scale battery module with the baseline RBD-CFRC and conduct mechanical crush test to develop an initial thermal runaway model. Test the adhesive properties of the RBD-CFRCs using their resin constituent, ultrasonic welding, and other resins employed today. Recommend a future direction for resin development to enable the welding of RBDCFRCs to dissimilar materials. Time and Cost Permitting. Iterate on resin development for flame resistance and adhesive properties, demonstrating how thermal runaway can be reduced or joining properties can be improved.

33 ADVANCED PROPULSION SYSTEMS↗

Multifunctional nanopore electrode array method for characterizing and manipulating single entities in attoliter-volume enclosures

Structurally regular nanopore arrays fabricated to contain independently controllable annular electrodes represent a new kind of architecture capable of electrochemically addressing small collections of matter—down to the single entity (molecule, particle, and biological cell) level. Furthermore, these nanopore electrode arrays (NEAs) can also be interrogated optically to achieve single entity spectroelectrochemistry. Larger entities such as nanoparticles and single bacterial cells are investigated by dark-field scattering and potential-controlled single-cell luminescence experiments, respectively, while NEA-confined molecules are probed by single molecule luminescence. By carrying out these experiments in arrays of identically constructed nanopores, massively parallel collections of single entities can be investigated simultaneously. The multilayer metal–insulator design of the NEAs enables highly efficient redox cycling experiments with large increases in analytical sensitivity for chemical sensing applications. NEAs may also be augmented with an additional orthogonally designed nanopore layer, such as a structured block copolymer, to achieve hierarchically organized multilayer structures with multiple stimulus-responsive transport control mechanisms. Finally, NEAs constructed with a transparent bottom layer permit optical access to the interior of the nanopore, which can result in the cutoff of far-field mode propagation, effectively trapping radiation in an ultrasmall volume inside the nanopore. Furthermore, the bottom metal layer may be used as both a working electrode and an optical cladding layer, thus, producing bifunctional electrochemical zero-mode waveguide architectures capable of carrying out spectroelectrochemical investigations down to the single molecule level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗