Electrochemistry of system - Heat sterilizable impact resistant cell development Final report, 30 Sep. 1967 - 31 Mar. 1970
Impact resistant and heat sterilizable silver-zinc batteries for spacecraft power supplies
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Impact resistant and heat sterilizable silver-zinc batteries for spacecraft power supplies
Heat sterilizable and impact resistant nickel cadmium battery development
Electrolysis of silicate melts has been shown to be an effective means of producing metals from common silicate materials. No fluxing agents need be added to the melts. From solution in melts of diopside (CaMgSi2O6) composition, the elements Si, Ti, Ni, and Fe have been reduced to their metallic states. Platinum is a satisfactory anode material, but other cathode materials are needed. Electrolysis of compositional analogs of lunar rocks initially produces iron metal at the cathode and oxygen gas at the anode. Utilizing mainly heat and electricity which are readily available from sunlight, direct electrolysis is capable of producing useful metals from common feedstocks without the need for expendable chemicals. This simple process and the products obtained from it deserve further study for use in materials processing in space.
Design and performance requirements for electrochemical power storage systems are discussed and some of the approaches towards satisfying these constraints are described. Geosynchronous and low Earth orbit applications, radar type load constraints, and high voltage systems requirements are addressed. In addition, flywheel energy storage is discussed.
The higher power and higher voltage levels anticipated for future space missions have required a careful review of the techniques currently in use to preclude battery problems that are related to the dispersion characteristics of the individual cells. Not only are the out-of-balance problems accentuated in these larger systems, but the thermal management considerations also require a greater degree of accurate design. Newer concepts which employ active cooling techniques are being developed which permit higher rates of discharge and tighter packing densities for the electrochemical components. This paper will put forward six semi-independent principles relating to battery systems. These principles will progressively address cell, battery and finally system related aspects of large electrochemical storage systems.
Fundamental electrochemical studies on three candidate materials, i.e., FeCl2, NiCl2, and CuCl2, were carried out using various techniques, such as cyclic voltammetry, linear polarization, potentiodynamic polarization, and ac impedance. These studies were aimed at identifying various rate processes in the reduction, elucidating the reaction mechanisms, and determining the kinetic parameters for the reduction. The limitations in the performance of these cathode materials in high power density applications were also examined. Finally, recommendations were made from these studies for the selection of a candidate system among these materials for future NASA applications.
Results are presented on determinations of reduction potentials and their temperature dependence of selected ions in diopsidic melt, by using linear sweep voltammetry. Diffusion coefficients were measured for cations of Eu, Mn, Cr, and In. Enthalpies and entropies of reduction were determined for the cations V(V), Cr(3+), Mn(2+), Mn(3+), Fe(2+), Cu(2+), Mo(VI), Sn(IV), and Eu(3+). Reduction potentials were used to study the structural state of cations in the melt.
A microfluidic analytical system for the separation and detection of organic peroxides, based on a microchip capillary electrophoresis device with an integrated amperometric detector, was developed. The new microsystem relies on the reductive detection of both organic acid peroxides and hydroperoxides at -700 mV (vs. Ag wire/AgCl). Factors influencing the separation and detection processes were examined and optimized. The integrated microsystem offers rapid measurements (within 130 s) of these organic-peroxide compounds, down to micromolar levels. A highly stable response for repetitive injections (RSD 0.35-3.12%; n = 12) reflects the negligible electrode passivation. Such a "lab-on-a-chip" device should be attractive for on-site analysis of organic peroxides, as desired for environmental screening and industrial monitoring.
Nanoparticle arrays biologically derived from an electrochemically-controlled site-specific biomineralization were fabricated on a gold substrate through the immobilization process of biomolecules. The work reported herein includes the immobilization of ferritin with various surface modifications, the electrochemical biomineralization of ferritins with different inorganic cores, the fabrication of self-assembled arrays with the immobilized ferritin, and the electrochemical characterization of various core materials. Protein immobilization on the substrate is achieved by anchoring ferritins with dithiobis-N-succinimidyl propionate (DTSP). A reconstitution process of electrochemical site-specific biomineralization with a protein cage loads ferritins with different core materials such as Pt, Co, Mn, and Ni. The ferritin acts as a nano-scale template, a biocompatible cage, and a separator between the nanoparticles. The nano-sized metalcored ferritins on a gold substrate displayed a good electrochemical activity for the electron transport and storage, which is suitable for bioelectronics applications such as biofuel cell, bionanobattery, biosensors, etc. Keywords: Ferritin, immobilization, site-specific reconstitution, biomineralization, and bioelectronics
There are three kinds of body forces operating in electrolytic solutions in the magnetic field: the magnetohydrodynamic force F(sub B) (=i x B), the F(sub delB) force (approximately B(raised dot)gradB) and the F(sub delC) force (approximately |B|(sup 2)gradC). These three forces manifest themselves differently, depending on the experimental conditions. Thus, diamagnetic disc millielectrodes (e.g., Au) with their plane parallel to the flux density of the homogeneous magnetic field of an electromagnet yield convective behavior analogous to that observed with rotating electrodes; that response is controlled by F(sub B). The same electrodes placed in the inhomogeneous field of a strong permanent magnet yield also convective behavior that is controlled by both F(sub B) and F(sub delB). Finally, similarly sized millielectrodes made of permanent magnets (e.g., Au-coated Nd-Fe-B discs) yield diffusion-controlled behavior at conditions where a gold disc electrode shows behavior dominated by density gradient driven natural convection; in this case the predominant forces are both F(sub delB) and F(sub delC). Under open circuit conditions, ferromagnetic (i.e., magnetizable) millielectrodes (Co, Fe, Ni) dipped in corrosive solutions and placed in homogeneous magnetic fields yield mass-transfer phenomena that seem to be controlled by magnetophoresis.
This presentation covers an overview of NASA Glenn s history and heritage in the development of electrochemical systems for aerospace applications. Specific areas of focus are Li-ion batteries and their development for future Exploration missions. Current component development efforts for high energy and ultra high energy Li-ion batteries are addressed. Electrochemical systems are critical to the success of Exploration, Science and Space Operations missions. NASA Glenn has a long, successful heritage with batteries and fuel cells for aerospace applications. GRC Battery capabilities and expertise span basic research through flight hardware development and implementation. There is a great deal of synergy between energy storage system needs for aerospace and terrestrial applications.
This presentation covers an overview of NASA Glenn s history and heritage in the development of electrochemical systems for aerospace applications. Current developments related to batteries and fuel cells are addressed. Specific areas of focus are Li-ion batteries and Polymer Electrolyte Membrane Fuel cells systems and their development for future Exploration missions.
No abstract available
No abstract provided
The White House Office of Science and Technology Policy (OSTP) has declared 2023 to be the Year of Open Science following an initiative to democratize scientific knowledge. Simultaneously, new sensor technologies have broadened the experimental space available to bioastronautics research. With these open-science goals and technological advances in mind, we have designed and constructed a data acquisition platform for high-precision, real-time monitoring of liquid culture systems. The vessel rig is fitted with six Atlas Scientific probes (micro pH, electrical conductivity, dissolved oxygen, oxidation-reduction potential, liquid temperature, air CO2) and a custom optical density probe similar to the one on BioSentinel’s BioSensor payload. A custom dielectric spectroscopy probe is also planned. The structure of the vessel is resin 3-D printed on a hobbyist-level machine, reducing the production cost and iteration time by over 60% each while increasing extensibility. Data acquisition and storage is controlled with a standalone C state machine-based program running on a Raspberry Pi 3 Model B. When not running headless, an additional program automatically generates and updates plots for live data visualization. Validation of the rig as a data collection system was performed with a yeast liquid culture experiment. While the vessel rig is currently used for standalone experiments, it can also be used as the base perception unit in a self-driving laboratory (SDL). SDLs are high-throughput data collection systems that employ automation and artificial intelligence to conduct and manage routine experiments. Here, we envision an SDL driven by several vessel rigs in which an automated script compares key results, informing the design of future experiments. A vessel rig SDL would streamline many operations, including 1) strain selection for the Lunar Explorer Instrument for space biology Applications (LEIA) investigation and 2) the study of bioregenerative life support systems (BLSS). Ultimately, the datasets that can now be acquired will provide crucial information for accelerating bioastronautics application development in the era of commercial space.
The BioSensor payload on the upcoming LEIA platform aboard a CLPS lander will carry yeast to the moon to study response to radiation and lunar gravity. The LEIA BioSensor is designed to monitor metabolic activity using absorbance in conjunction with alamarBlue for measuring colorimetric changes as proxy measurement for redox potential. The science data returned from small spacecraft mission modules like LEIA is limited as it relies solely on optical measurements, necessitating a corresponding ground mapping unit that is equipped with multiple electrochemical sensors for accurate mapping of the optical data and operates fully automatically. This technology development work discusses the extensive design and optimization efforts put into the ground mapping unit, MVISE. MVISE is a custom designed, 3D-printed vessel with an agitation system, with six different electrochemical sensor probes, and ports for sample collection and a pressure release valve. The sensors provide real-time data, with dry absorbance measurements aligning with LEIA flight hardware and wet measurements demonstrating invasive sensor design enabling a comparison between the two setups. The 3D printer resin was tested for mechanical robustness, biocompatibility, and resistance to autoclave sterilization. The inner walls were coated with food-grade epoxy, ensuring a smooth finish to prevent microbial lodging and dye staining. The MVISE has successfully passed a week-long leak test and is now undergoing active biology tests. The MVISE prototype will be prepared for radiation tests, with three identical units being tested for varying radiation levels and culture compositions at the NASA Space Radiation Laboratory in November 2024. The integrated sensor approach proposed in this work will enable the accurate mapping of the BioSentinel/LEIA optical flight data to six sensor parameters on the ground unit for better science data return and will enable the first effort to evaluate classical biochemical sensor measurements by comparing and contrasting their responses.
The tasks of the Electrochemistry Branch of NASA Glenn Research Center are to improve and develop high energy density and rechargeable, life-long batteries. It is with these batteries that people across the globe are able to power their cell phones, laptop computers, and cameras. Here, at NASA Glenn Research Center, the engineers and scientists of the Electrochemistry branch are leading the way in the development of more powerful, long life batteries that can be used to power space shuttles and satellites. As of now, the cutting edge research and development is being done on nickel-hydrogen batteries and lithium ion batteries. Presently, nickel-hydrogen batteries are common types of batteries that are used to power satellites, space stations, and space shuttles, while lithium batteries are mainly used to power smaller appliances such as portable computers and phones. However, the Electrochemistry Branch at NASA Glenn Research Center is focusing more on the development of lithium ion batteries for deep space use. Because of the limitless possibilities, lithium ion batteries can revolutionize the space industry for the better. When compared to nickel-hydrogen batteries, lithium ion batteries possess more advantages than its counterpart. Lithium ion batteries are much smaller than nickel-hydrogen batteries and also put out more power. They are more energy efficient and operate with much more power at a reduced weight than its counterpart. Lithium ion cells are also cheaper to make, possess flexibility that allow for different design modifications. With those statistics in hand, the Electrochemistry Branch of NASA Glenn has decided to shut down its Nickel-Hydrogen testing for lithium ion battery development. Also, the blackout in the summer of 2003 eliminated vital test data, which played a part in shutting down the program. from the nickel-hydrogen batteries and compare it to past data. My other responsibilities include superheating the electrolyte that is used in the nickel-hydrogen cell in a calorimeter to test its performance under various conditions. 1 used a program called Arbin to study my data. The Arbin allows me to look at different parameters such as pressure and time and how they affect the changing temperature of the electrolyte that is being tested. In addition, I had the responsibility of taking apart and modifying battery coolers that would be used. My mentors told me that the batteries kept shutting down, so it was my responsibility to remove excess fan grilles, rotate the fans, and then switch the aluminum standoffs with nylon ones so that the coolers could operate without problems. My last task is to collect all the battery test data and organize them into charts using Microsoft Excel, before the Branch is able to conduct its research on lithium ion batteries. Therefore, during my tenure, it is my responsibility to take down final test data