Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXPONENTIAL FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Parameterization of photon beam dosimetry for a linear accelerator

Purpose: In radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (TPS), (2) comparing measured and TPS modeled data, (3) the quality assurance process of a linear accelerator’s (Linac) beam characteristics, (4) the establishment of a standard data set for comparison with other data, etcetera. Parameterization of the photon beam dosimetry creates a data set that is portable and easy to implement for different applications such as those previously mentioned. The aim of this study is to develop methods to parameterize photon beam dosimetric quantities, including percentage depth doses (PDDs), profiles, and total scatter output factors (S{sub cp}). Methods: S{sub cp}, PDDs, and profiles for different field sizes, depths, and energies were measured for a Linac using a cylindrical 3D water scanning system. All data were smoothed for the analysis and profile data were also centered, symmetrized, and geometrically scaled. The S{sub cp} data were analyzed using an exponential function. The inverse square factor was removed from the PDD data before modeling and the data were subsequently analyzed using exponential functions. For profile modeling, one halfside of the profile was divided into three regions described by exponential, sigmoid, and Gaussian equations. All of the analytical functions are field size, energy, depth, and, in the case of profiles, scan direction specific. The model’s parameters were determined using the minimal amount of measured data necessary. The model’s accuracy was evaluated via the calculation of absolute differences between the measured (processed) and calculated data in low gradient regions and distance-to-agreement analysis in high gradient regions. Finally, the results of dosimetric quantities obtained by the fitted models for a different machine were also assessed. Results: All of the differences in the PDDs’ buildup and the profiles’ penumbra regions were less than 2 and 0.5 mm, respectively. The differences in the low gradient regions were 0.20% ± 0.20% (<1% for all) and 0.50% ± 0.35% (<1% for all) for PDDs and profiles, respectively. For S{sub cp} data, all of the absolute differences were less than 0.5%. Conclusions: This novel analytical model with minimum measurement requirements was proved to accurately calculate PDDs, profiles, and S{sub cp} for different field sizes, depths, and energies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Luminescence Decay of Colloidal Quantum Dots and Stretched Exponential (Kohlrausch) Relaxation Function

The room temperature non-exponential luminescence decay of colloidal quantum dots is investigated theoretically in an attempt to identify the underlying physical mechanisms responsible for the shape of the decay. It is shown that a stretched exponential functional form of the luminescence decay can be understood in terms of long-range resonance energy transfer from quantum dots to acceptors (molecules, quantum dots, or anharmonic molecular vibrations) or by contact quenching by quenchers (surface traps, molecules or quantum dots) distributed statistically (Poisson distribution) on the surface of the dots. These non-radiative transition processes are assigned to different ranges of the stretching parameter β.

36 MATERIALS SCIENCE↗

BUCKLING OF INITIALLY IMPERFECT AXIALLY COMPRESSED CYLINDRICAL SHELLS

The effects of imperfections on the buckling strength of pressurized cylinders under axial compression are studied. The imperfection factor is considered in the finite-deflection compatibility equation, as well as in the equilibrium equation. A new relation to express the imperfection as an explicit exponential function of pressure and radius thickness ratio is proposed. A method for finding the exponential function is described, and the solution for the critical stress is found in a fairly simple form. The relation of decrease of stability with respect to magnitude of imperfections if found.

CYLINDRICAL SHELL↗

Prediction of Unsteady Aerodynamic Coefficients at High Angles of Attack

The nonlinear indicial response method is used to model the unsteady aerodynamic coefficients in the low speed longitudinal oscillatory wind tunnel test data of the 0.1 scale model of the F-16XL aircraft. Exponential functions are used to approximate the deficiency function in the indicial response. Using one set of oscillatory wind tunnel data and parameter identification method, the unknown parameters in the exponential functions are estimated. The genetic algorithm is used as a least square minimizing algorithm. The assumed model structures and parameter estimates are validated by comparing the predictions with other sets of available oscillatory wind tunnel test data.

Pamadi, Bandu N.↗

An Experimental Study of the Rainfall Variability Within TRMM/GPM Precipitation Radar and Microwave Sensor Instantaneous Field of View During MC3E

Dual tipping bucket gauges were operated at 16 sites in support of ground based precipitation measurements during Mid-latitude Continental Convective Clouds Experiment (MC3E). The experiment is conducted in North Central Oklahoma from April 22 through June 6, 2011. The gauge sites were distributed around Atmospheric Radiation Measurement (ARM) Climate Research facility where the minimum and maximum separation distances ranged from 1 to 12 km. This study investigates the rainfall variability by employing the stretched exponential function. It will focus on the quantitative assessment of the partial beam of the experiment area in both convective and stratiform rain. The parameters of the exponential function will also be determined for various events. This study is unique for two reasons. First is the existing gauge setup and the second is the highly convective nature of the events with rain rates well above 100 mm h-1 for 20 minutes. We will compare the findings with previous studies.

Tokay, Ali↗

An Experimental Study of the Rainfall Variability Within TRMM/GPM Precipitation Radar and Microwave Sensor Instantaneous Field of View During MC3E

Dual tipping bucket gauges were operated at 16 sites in support of ground based precipitation measurements during Mid-latitude Continental Convective Clouds Experiment (MC3E). The experiment is conducted in North Central Oklahoma from April 22 through June 6, 2011. The gauge sites were distributed around Atmospheric Radiation Measurement (ARM) Climate Research facility where the minimum and maximum separation distances ranged from 1 to 12 km. This study investigates the rainfall variability by employing the stretched exponential function. It will focus on the quantitative assessment of the partial beam of the experiment area in both convective and stratiform rain. The parameters of the exponential function will also be determined for various events. This study is unique for two reasons. First is the existing gauge setup and the second is the highly convective nature of the events with rain rates well above 100 mm/h for 20 minutes. We will compare the findings with previous studies.

Tokay, Ali↗

Complexity and Productivity Differentiation Models of Metallogenic Indicator Elements in Rocks and Supergene Media Around Daijiazhuang Pb-Zn Deposit in Dangchang County, Gansu Province

With the help of complexity indices, we quantitatively studied multifractals, frequency distributions, and linear and nonlinear characteristics of geochemical data for exploration of the Daijiazhuang Pb-Zn deposit. Furthermore, we derived productivity differentiation models of elements from thermodynamics and self-organized criticality of metallogenic systems. With respect to frequency distributions and multifractals, only Zn in rocks and most elements except Sb in secondary media, which had been derived mainly from weathering and alluviation, exhibit nonlinear distributions. The relations of productivity to concentrations of metallogenic elements and paragenic elements in rocks and those of elements strongly leached in secondary media can be seen as linear addition of exponential functions with a characteristic weak chaos. The relations of associated elements such as Mo, Sb, and Hg in rocks and other elements in secondary media can be expressed as an exponential function, and the relations of one-phase self-organized geological or metallogenic processes can be represented by a power function, each representing secondary chaos or strong chaos. For secondary media, exploration data of most elements should be processed using nonlinear mathematical methods or should be transformed to linear distributions before processing using linear mathematical methods.

58 GEOSCIENCES↗

Elementary Theoretical Forms for the Spatial Power Spectrum of Earth's Crustal Magnetic Field

The magnetic field produced by magnetization in Earth's crust and lithosphere can be distinguished from the field produced by electric currents in Earth's core because the spatial magnetic power spectrum of the crustal field differs from that of the core field. Theoretical forms for the spectrum of the crustal field are derived by treating each magnetic domain in the crust as the point source of a dipole field. The geologic null-hypothesis that such moments are uncorrelated is used to obtain the magnetic spectrum expected from a randomly magnetized, or unstructured, spherical crust of negligible thickness. This simplest spectral form is modified to allow for uniform crustal thickness, ellipsoidality, and the polarization of domains by an periodically reversing, geocentric axial dipole field from Earth's core. Such spectra are intended to describe the background crustal field. Magnetic anomalies due to correlated magnetization within coherent geologic structures may well be superimposed upon this background; yet representing each such anomaly with a single point dipole may lead to similar spectral forms. Results from attempts to fit these forms to observational spectra, determined via spherical harmonic analysis of MAGSAT data, are summarized in terms of amplitude, source depth, and misfit. Each theoretical spectrum reduces to a source factor multiplied by the usual exponential function of spherical harmonic degree n due to geometric attenuation with attitude above the source layer. The source factors always vary with n and are approximately proportional to n(exp 3) for degrees 12 through 120. The theoretical spectra are therefore not directly proportional to an exponential function of spherical harmonic degree n. There is no radius at which these spectra are flat, level, or otherwise independent of n.

Voorhies, C.↗

Fracture Mechanics Properties of Fused Silicas Used for International Space Station Windowpanes

The fracture toughness and slow crack growth (SCG) parameters of a quartz-based silica and a high-purity fused silica were measured as part of a program to review the reliability of the International Space Station windows. The materials exhibit the same fracture toughness (.75 MPa m^(1/2) in N2) and very similar SCG parameters. The literature on fused silica indicates excellent agreement of fracture toughness, but a very wide range of SCG parameters, even from the same institution, with strength-based methods usually yielding a lower power law exponent than direct crack velocity measurements. Use of the exponential function is shown to provide better agreement between test methods, with velocity curves derived from strength tests of bare fiber and polished or ground test specimens paralleling those from wide-range, direct crack velocity observations, implying that constant stress rate tests can predict long lifetime via the exponential function. However, much variation still exists. SCG parameters for soda–lime silicate are much less sensitive to the test method than fused silica. Static load tests and stress intensity measurements resulted in a fatigue threshold of .3 MPa m^(1/2) for fused silica.

Silica, toughness, impact, crack growth, windows, ↗

Electrical and Optical Characteristics of Si-Nanoparticle Films Deposited onto Substrates by High-Voltage Electrospraying from Ethanol Sols

The optical and electrical characteristics of films consisting of nanocrystalline silicon (nc-Si) deposited onto substrates by the high-voltage electrospraying of nc-Si sols in ethanol are investigated. It is found that the interaction of ethanol droplets carrying Si nanoparticles with a corona-discharge electric field leads to the polymerization of ethanol and the formation of a polymer layer on the Si-nanoparticle surface. A high-voltage facility for depositing the films using an additional focusing electrode allows one to change the geometry of the electric field and intensity in the region of the ethanol droplet flow. As a result, nc-Si films with qualitatively different properties of the polymer on the nanoparticle surface are formed, specifically, nc-Si-A and nc-Si-B, obtained without a focusing electrode and with it, respectively. Upon annealing at temperatures of up to 400°С, the optical band gap E{sub g} of the nc-Si-A films increases from ~1.9 to ~2.2 eV, while the E{sub g} value of the nc-Si-B films remains constant and amounts to 1.85 eV. The constant E{sub g} value of the nc-Si-B films is explained by the properties of the polymer on the Si-nanoparticle surface and the more effective blocking of oxygen penetration from the surrounding environment upon annealing at temperatures of up to 400°C than in the case of a polymer in nc-Si-A films. The temperature dependences of the dark and photoinduced conductivity of nc-Si-A films are approximated with good accuracy by two activation-type exponential functions and the dark activation energies are ~0.75 and 0.1 eV, respectively. The conductivity of the nc-Si-A films noticeably decreases under irradiation of the samples at wavelengths of 460–470 nm. The temperature dependences of the conductivity of the nc-Si-B films are approximated with good accuracy by exponential functions with activation energies of 0.73 (in the dark) and 0.59 eV (under photoexcitation). In contrast to the case of nc-Si-A films, the photoconductivity of nc-Si-B films grows more than fourfold relative to the dark conductivity under analogous illumination. The nc-Si-B films are photoactive and sandwich-like Al/nc-Si-B/Al structures can generate a voltage. The dark conductivity and photoconductivity of the nc-Si-A films in the voltage range of V > 2 V are determined by the two-center Poole–Frenkel effect; the concentration of the centers affecting the Poole–Frenkel conductivity is ~3 × 10{sup 17} cm{sup –3}. In nc-Si-B films in the voltage range of 2–5 V, electron transport is determined by space-charge-limited currents and, at high voltages, by the two-center Poole–Frenkel effect. The concentration of traps contributing to the space-charge-limited currents is ~4 × 10{sup 16} cm{sup –3}. The concentration of Poole–Frenkel centers affecting the conductivity decreases according to the activation law with an activation energy of 0.7 eV from 3 × 10{sup 16} to 2 × 10{sup 14} cm{sup –3} with a decrease in temperature from 120°C to 40°C.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-G-TeP1-10: Predicting Photon Percentage Depth Dose From Profile Due to Changes in Beam Quality

Purpose: To predict photon percentage depth dose (PDD) from profile due to a change in flattened (FF) and flattening-filter-free (FFF) beam quality. Methods: 6MV photon beam PDDs and profiles in a 3D water tank (3DW) and profiles in an ionization chamber array (ICP) were collected for different field sizes and depths with FF and FFF beams in a Versa HD (Elekta Ltd.). The energy was adjusted by changing the bending magnet current (BMC) ±15% from the clinical beam (6MV) in 5% increments. For baseline establishment, PDDs(depth≥3cm) were parameterized with bi-exponential functions and the PDD 20 to 10cm ratios (PDD{sub 20,10}) were calculated. Then, the FF profile at 10cm from the central axis (Pr{sub 10}) and the slope of the FFF central linear region (SFFF) were calculated. Calibration curves were established: (1) change in Pr{sub 10} and SFFF as functions of the change in PDD{sub 20,10} and (2) change in PDD(depth=3, 15 and 30cm) as function of the change in PDD{sub 20,10}. The differences between Pr{sub 10} and SFFF from baseline were calculated and, from calibration curves, changes in PDD{sub 20,10} and PDD(depth=3, 15 and 30cm) were obtained. Then, absolute PDD(depth=3, 15 and 30cm) values were input into a least-square-optimization algorithm to calculate the bi-exponential function’s optimal coefficients and generate the PDD(depths≥3cm). Results: The change in PDD{sub 20,10} relative to baseline increased (<±4%) with BMC. Pr{sub 10} increased (±6%) and SFFF decreased (±11%) with BMC. Relative differences between measured and calculated (i.e. PDD calculation from Pr{sub 10} and SFFF) PDDs were less than 1%. Results apply to FF and FFF beams measured in 3DW and ICP. Conclusion: Pr{sub 10} and SFFF are more sensitive than PDD to changes in beam energy and PDD information can be accurately generated from them. With known 3DW and ICP profile relationship, ICP can be used to obtain PDD for current photon beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dependence of diode sensitivity on the pulse rate of delivered radiation

Purpose: It has been reported that diode sensitivity decreases by as much as 2% when the average dose rate set at the accelerator console was decreased from 600 to 40 MU/min. No explanation was given for this effect in earlier publications. This work is a detailed investigation of this phenomenon: the change of diode sensitivity versus the rate of delivery of dose pulses in the milliseconds and seconds range. Methods: X-ray beams used in this work had nominal energies of 6 and 15 MV and were generated by linear accelerators. The average dose rate was varied from 25 to 600 MU/min, which corresponded to time between microsecond-long dose pulses of 60-2.7 ms, respectively. The dose-per-pulse, dpp, was changed by positioning the detector at different source-to-detector distance. A variety of diodes fabricated by a number of manufacturers were tested in this work. Also, diodes in three different MapCHECKs (Sun Nuclear, Melbourne, FL) were tested. Results: For all diodes tested, the diode sensitivity decreases as the average dose rate is decreased, which corresponds to an increase in the pulse period, the time between radiation pulses. A sensitivity decrease as large as 5% is observed for a 60-ms pulse period. The diode sensitivity versus the pulse period is modeled by an empirical exponential function. This function has a fitting parameter, t{sub eff}, defined as the effective lifetime. The values of t{sub eff} were found to be 1.0-14 s, among the various diodes. For all diodes tested, t{sub eff} decreases as the dpp decreases and is greater for 15 MV than for 6 MV x rays. The decrease in diode sensitivity after 20 s without radiation can be reversed by as few as 60 radiation pulses. Conclusions: A decrease in diode sensitivity occurs with a decrease in the average dose rate, which corresponds to an increase in the pulse period of radiation. The sensitivity decrease is modeled by an empirical exponential function that decreases with an effective lifetime, t{sub eff}, of 1.0-14 s. t{sub eff} varies widely for different diodes, dpp, and x-ray energy. It is hypothesized that the capture of excess minority carriers by charge traps, cause the observed decrease in diode sensitivity. Also, it is hypothesized that the slow reopening of these traps occurs in the hundreds of milliseconds to seconds range at ambient temperature and this underlies the slow decrease in the diode sensitivity. Calibration of a diode is best done at the average dose rate with which it will be used. This is easily accomplished for radiation deliveries in which the average dose rate is a constant. However, for a VMAT delivery the average dose rate is a variable. For measurements made under these conditions diodes can be calibrated with a median or average dose rate which splits the difference in diode sensitivity that is known to occur with changes in average dose rate.

60 APPLIED LIFE SCIENCES↗

THE 2010 VERY HIGH ENERGY {gamma}-RAY FLARE AND 10 YEARS OF MULTI-WAVELENGTH OBSERVATIONS OF M 87

The giant radio galaxy M 87 with its proximity (16 Mpc), famous jet, and very massive black hole ((3 - 6) Multiplication-Sign 10{sup 9} M{sub Sun }) provides a unique opportunity to investigate the origin of very high energy (VHE; E > 100 GeV) {gamma}-ray emission generated in relativistic outflows and the surroundings of supermassive black holes. M 87 has been established as a VHE {gamma}-ray emitter since 2006. The VHE {gamma}-ray emission displays strong variability on timescales as short as a day. In this paper, results from a joint VHE monitoring campaign on M 87 by the MAGIC and VERITAS instruments in 2010 are reported. During the campaign, a flare at VHE was detected triggering further observations at VHE (H.E.S.S.), X-rays (Chandra), and radio (43 GHz Very Long Baseline Array, VLBA). The excellent sampling of the VHE {gamma}-ray light curve enables one to derive a precise temporal characterization of the flare: the single, isolated flare is well described by a two-sided exponential function with significantly different flux rise and decay times of {tau}{sup rise}{sub d} = (1.69 {+-} 0.30) days and {tau}{sup decay}{sub d} = (0.611 {+-} 0.080) days, respectively. While the overall variability pattern of the 2010 flare appears somewhat different from that of previous VHE flares in 2005 and 2008, they share very similar timescales ({approx}day), peak fluxes ({Phi}{sub >0.35TeV} {approx_equal} (1-3) Multiplication-Sign 10{sup -11} photons cm{sup -2} s{sup -1}), and VHE spectra. VLBA radio observations of 43 GHz of the inner jet regions indicate no enhanced flux in 2010 in contrast to observations in 2008, where an increase of the radio flux of the innermost core regions coincided with a VHE flare. On the other hand, Chandra X-ray observations taken {approx}3 days after the peak of the VHE {gamma}-ray emission reveal an enhanced flux from the core (flux increased by factor {approx}2; variability timescale <2 days). The long-term (2001-2010) multi-wavelength (MWL) light curve of M 87, spanning from radio to VHE and including data from Hubble Space Telescope, Liverpool Telescope, Very Large Array, and European VLBI Network, is used to further investigate the origin of the VHE {gamma}-ray emission. No unique, common MWL signature of the three VHE flares has been identified. In the outer kiloparsec jet region, in particular in HST-1, no enhanced MWL activity was detected in 2008 and 2010, disfavoring it as the origin of the VHE flares during these years. Shortly after two of the three flares (2008 and 2010), the X-ray core was observed to be at a higher flux level than its characteristic range (determined from more than 60 monitoring observations: 2002-2009). In 2005, the strong flux dominance of HST-1 could have suppressed the detection of such a feature. Published models for VHE {gamma}-ray emission from M 87 are reviewed in the light of the new data.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental modal analysis

Experimental modal analysis is extremely important with regard to verification of analytical models, identification of vibration and acoustic problems, and structural modification and sensitivity analysis. With the expanding access of the testing environment to computational power, the complexity of existing approaches, as well as the development of new approaches, to the estimation of modal parameters has grown tremendously. Currently, the state of the art in experimental modal analysis involves methods that can be grouped in four categories: forced normal mode excitation method, frequency response function method, damped complex exponential function method, and mathematical input-output model methods. The theoretical basis of each of these general approaches, with appropriate references, is reviewed briefly.

Allemang, R. J.↗

Semi-empirical calculation of depletion region width in n+-p silicon solar cells

An extension of the width calculation for impurity distributions of complementary error function and the Gaussian function, in addition to the exponential function is used in combination with experimental width values deduced from capacitance measurements at zero bias to numerically determine the width occurring in both the n+ and p junctions. The total possible error o the semi-empirical calculation is less than plus or minus 3%. Results show considerable variation in the depletion widths occurring in the n+ and p regions for different impurity profiles.

Wang, E. Y.↗

DE-1 observations of hole electron distribution functions and the cyclotron maser resonance

The hole electron distribution functions observed by the DE-1 satellite within inverted-V events at altitudes of between 9000 km and 15,000 km are examined as a possible free energy source for exciting Z-mode radiation through cyclotron maser resonance. In the DE-1 observations the hole distribution function had center velocities varying between 8000 km/s and 20,000 km/s, with the radii varying between 2000 km/s and 10,000 km/s. The observed distribution function is fitted by an exponential function around the center of the hole, and is used to calculate growth rates of Z-mode radiation. Growth rates as high as 0.001 of the electron gyrofrequency are obtained. It is also shown that the observed hole distribution functions can excite Z-mode radiation at wave frequencies slightly above the gyrofrequency, and wave propagation angles slightly below 90 deg in the source region. The results suggest that the hole distribution function could provide additional amplification for Z-mode waves in the auroral zone.

Lin, C. S.↗