Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXAFS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Study of Ga incorporation in glassy arsenic selenides by high-resolution XPS and EXAFS

Effect of Ga addition on the structure of vitreous As{sub 2}Se{sub 3} is studied using high-resolution X-ray photoelectron spectroscopy and extended X-ray absorption fine structure techniques. The “8-N” rule is shown to be violated for Ga atoms and, possibly, for certain number of As atoms. On the contrary, Se keeps its 2-fold coordination according to “8-N” rule in the amorphous phase throughout all the compositions. Crystalline inclusions appear in the amorphous structure of the investigated glasses at Ga concentrations greater than 3 at. %. These inclusions are presumably associated with Ga{sub 2}Se{sub 3} crystallites and transition phases/defects formed at the boundaries of these crystallites and host amorphous matrix. The existence of Ga–As and Se–Se bonds in the samples with higher Ga content is supported by present studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Confirmation of standard error analysis techniques applied to EXAFS using simulations

Systematic uncertainties, such as those in calculated backscattering amplitudes, crystal glitches, etc., not only limit the ultimate accuracy of the EXAFS technique, but also affect the covariance matrix representation of real parameter errors in typical fitting routines. Despite major advances in EXAFS analysis and in understanding all potential uncertainties, these methods are not routinely applied by all EXAFS users. Consequently, reported parameter errors are not reliable in many EXAFS studies in the literature. This situation has made many EXAFS practitioners leery of conventional error analysis applied to EXAFS data. However, conventional error analysis, if properly applied, can teach us more about our data, and even about the power and limitations of the EXAFS technique. Here, we describe the proper application of conventional error analysis to r-space fitting to EXAFS data. Using simulations, we demonstrate the veracity of this analysis by, for instance, showing that the number of independent dat a points from Stern's rule is balanced by the degrees of freedom obtained from a 2 statistical analysis. By applying such analysis to real data, we determine the quantitative effect of systematic errors. In short, this study is intended to remind the EXAFS community about the role of fundamental noise distributions in interpreting our final results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sequestration of Sr(II) By Calcium Oxalate - a Batch Uptake Study And EXAFS Analysis of Model Compounds And Reaction Products

Calcium oxalate monohydrate (CaC{sub 2}O{sub 4}{center_dot}H{sub 2}O -- abbreviated as CaOx) is produced by two-thirds of all plant families, comprising up to 80 wt.% of the plant tissue and found in many surface environments. It is unclear, however, how CaOx in plants and soils interacts with metal ions and possibly sequesters them. This study examines the speciation of Sr(II){sub aq} following its reaction with CaOx. Batch uptake experiments were conducted over the pH range 4--10, with initial Sr solution concentrations, [Sr]{sub aq}, ranging from 1 x 10{sup -4} to 1 x 10{sup -3} M and ionic strengths ranging of 0.001--0.1 M, using NaCl as the background electrolyte. Experimental results indicate that Sr uptake is independent of pH and ionic strength over these ranges. After exposure of CaOx to Sr{sub aq} for two days, the solution Ca concentration, [Ca]{sup aq}, increased for all samples relative to the control CaOx suspension (with no Sr added). The amount of Sr{sub aq} removed from solution was nearly equal to the total [Ca]{sup aq} after exposure of CaOx to Sr. These results suggest that nearly 90% of the Sr is removed from solution to a solid phase as Ca is released into solution. We suggest that the other 10% is sequestered through surface adsorption on a solid phase, although we have no direct evidence for this. Extended X-ray absorption fine structure (EXAFS) spectroscopy was used to determine the molecular-level speciation of Sr in the reaction products. Deconvolutions of the Sr K-edge EXAFS spectra were performed to identify multi-electron excitation (MEE) features. MEE effects were found to give rise to low-frequency peaks in the Fourier transform before the first shell of oxygen atoms and do not affect EXAFS fitting results. Because of potential problems caused by asymmetric distributions of Sr-O distances when fitting Sr K-edge EXAFS data using the standard harmonic model, we also employed a cumulant expansion model and an asymmetric analytical model to account for anharmonic effects in the EXAFS data. For Sr-bearing phases with low to moderate first-shell (Sr-O pair correlation) anharmonicity, the cumulant expansion model is sufficient for EXAFS fitting; however, for higher degrees of anharmonicity, an analytical model is required. Based on batch uptake results and EXAFS analyses of reaction products, we conclude that Sr is dominantly sequestered by a solid phase at the CaOx surface, likely the result of a dissolution-reprecipitation mechanism, to form SrC{sub 2}O{sub 4} of mixed hydration state (i.e. SrO{sub x}{center_dot}nH{sub 2}O, where n = 0, 1, or 2). Surprisingly, no spectroscopic or XRD evidence was found for a (Sr,Ca)Ox solid solution or for a separate SrCO3 phase. In addition, we found no evidence for Sr(II) inner-sphere sorption complexes on CaOx surfaces based on lack of Sr-Ca second-neighbor pair correlations in the EXAFS spectra, although some type of Sr(II) surface complex (perhaps a type B Sr-oxalate ternary complex or an outer-sphere Sr(II) complex) or some as yet undetected Sr-bearing solid phases are needed to account for approximately 10% of Sr uptake by CaOx. The formation of a hydrated SrOx phase in environments under conditions similar to those of our experiments should retard Sr mobility and could be a significant factor in the biogeochemical cycling of Sr in soils and sediments or in plants and plant litter where CaOx is present.

04 OIL SHALES AND TAR SANDS↗

Predetermining acceptable noise limits in EXAFS spectra in the limit of stochastic noise

EXAFS measurements are used to probe a variety of experimental systems, but excel at elucidating local structure in samples which have slight disorder or no long-range crystalline order. Of special interest to the authors is the use of EXAFS in understanding the molecular-level binding structure and characteristics of actinides on the surface of environmental minerals and model mineral analogs. In environmental systems the element of interest can be on the order of 10-7% by weight of the total sample. Obviously such samples would be impossible to measure using EXAFS techniques. It is therefore essential to increase the concentration of the element of interest while still preserving a sample's ability to represent environmental conditions. Under such low concentration limits it is expected that the collected data is countrate, or stochastically limited. This condition occurs as we approach the signal-to-noise (S/N) limit of the technique where the random noise of the measurement process dominates over possible systematic errors. When stochastic error is expected to dominate systematic error, it is possible to predict, with the use of simulations, the ability of model fits to tolerate a certain level of stochastic noise. Elsewhere in these proceedings, we discuss how to tell when systematic errors dominate in measured EXAFS spectrum. Here, we outline a technique for determining the number of EXAFS scans necessary to test the relevance of a given structural model. Appropriate stochastic noise levels are determined for each point in r-space by collecting data on a real system. These noise levels are then applied to EXAFS simulations using a test model. In this way, all significant systematic error sources are eliminated in the simulated data. The structural model is then fit to the simulated data, decreasing the noise and increasing the k-range of the fit until the veracity of the model passes an F-test. This paper outlines a method of testing model systems in EXAFS fitting before measurements are conducted to determine the quality of measured data required for fitting of a particular model system with statistical confidence. It is important to reiterate that the calculated {alpha}surface in figure 1 is only applicable to the particular model presented in this paper. Furthermore, this procedure only takes into account stochastic noise; consequentially any confidence levels calculated should be viewed as upper limits to the confidence levels in systems which also contain a significant amount of systematic noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced EXAFS analysis techniques applied to the L -edges of the lanthanide oxides

The unique properties of the lanthanide (Ln) elements make them critical components of modern technologies, such as lasers, anti-corrosive films and catalysts. Thus, there is significant interest in establishing structure–property relationships for Ln-containing materials to advance these technologies. Extended X-ray absorption fine structure (EXAFS) is an excellent technique for this task considering its ability to determine the average local structure around the Ln atoms for both crystalline and amorphous materials. However, the limited availability of EXAFS reference spectra of the Ln oxides and challenges in the EXAFS analysis have hindered the application of this technique to these elements. The challenges include the limited k-range available for the analysis due to the superposition of L-edges on the EXAFS, multielectron excitations (MEEs) creating erroneous peaks in the EXAFS and the presence of inequivalent absorption sites. Herein, we removed MEEs to model the local atomic environment more accurately for light Ln oxides. Further, we investigated the use of cubic and non-cubic lattice expansion to minimize the fitting parameters needed and connect the fitting parameters to physically meaningful crystal parameters. The cubic expansion reduced the number of fitting parameters but resulted in a statistically worse fit. The non-cubic expansion resulted in a similar quality fit and showed non-isotropic expansion in the crystal lattice of Nd 2 O 3 . In total, the EXAFS spectra and the fits for the entire set of Ln oxides (excluding promethium) are included. The knowledge developed here can assist in the structural determination of a wide variety of Ln compounds and can further studies on their structure–property relationships.

36 MATERIALS SCIENCE↗

Single crystalline and rare earth substituted La{sub 2}RuO{sub 5} investigated by x-ray diffraction and EXAFS spectroscopy

Single crystals of La{sub 2}RuO{sub 5} were obtained from a BaCl{sub 2} flux. The structure was determined by single crystal x-ray diffraction and compared to earlier x-ray and neutron powder diffraction results. The local structures of Ru and La/Ln in pure La{sub 2}RuO{sub 5} and the rare earth substituted La{sub 2-x}Ln{sub x}RuO{sub 5} (Ln=Pr, Nd, Sm, Gd, Dy) polycrystalline samples were determined from the extended x-ray absorption fine structures (EXAFS) of the K- and L{sub III}-edges of Ru, La, and Ln, respectively. A four shell model was developed to reduce the number of refinable parameters in the fit of the EXAFS spectra. The distribution of the Ln-ions in the layered crystal structure was determined by a comparison of the coordination spheres obtained from the Ln-edges with the unsubstituted La{sub 2}RuO{sub 5}. Interatomic distances were compared to the values obtained from the single crystal diffraction and were found to agree very well. - Graphical abstract: The crystal structure of La{sub 2-x}Ln{sub x}RuO{sub 5} (Ln=Pr, Nd, Sm, Gd, Dy) is shown viewed along the c-axis. The alternating stacking of LaRuO{sub 4} and LnO layers leads to the formation of zig-zag layers of corner sharing RuO{sub 6} octahedra. The La sites in the LaRuO{sub 4} layers are represented by light blue spheres, while the La/Ln sites in the LnO layers are colored dark blue. EXAFS investigations reveal a cationic ordering with roughly 65% of the substituting Ln ions occupying the LnO layers. Highlights: Black-Right-Pointing-Pointer Structure determination of La{sub 2}RuO{sub 5} by single crystal x-ray diffraction. Black-Right-Pointing-Pointer Ru-K EXAFS investigations of La{sub 2-x}Ln{sub x}RuO{sub 5} powder samples. Black-Right-Pointing-Pointer EXAFS of La and Ln in La{sub 2-x}Ln{sub x}RuO{sub 5} powder samples using K- and L{sub III}-absorption edges. Black-Right-Pointing-Pointer Good agreement of EXAFS results and crystal structure data despite low symmetry space group. Black-Right-Pointing-Pointer Observed partial cationic ordering of the inserted Ln on the two La sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward a Machine Learning Approach to Interpreting X-ray Spectra of Trace Impurities by Converting XANES to EXAFS

The fact that the photoabsorption spectrum of a material contains information about the atomic structure, commonly understood in terms of multiple scattering theory, is the basis of the popular extended X-ray absorption spectroscopy (EXAFS) technique. How much of the same structural information is present in other complementary spectroscopic signals is not obvious. Here we use a machine learning approach to demonstrate that within theoretical models that accurately predict the EXAFS signal, the extended near-edge region does indeed contain the EXAFS-accessible structural information. We do this by exhibiting deep operator neural networks (DeepONets) that have learned the relationship between the extended and near edge portions of the X-ray absorption spectrum to predict the former from the latter. We find that we can accurately predict the EXAFS spectrum between 6 and 14 Å –1 from the first 6 Å –1 (≈100 eV) of the absorption spectrum of Cu 2 + substitutional defects in the Fe 3+ mineral hematite (α-Fe 2 O 3 ). This surprising finding implies that theoretical analyses of X-ray absorption spectra could be implemented that extract the same conclusions as high-quality EXAFS studies from spectra collected over a much smaller range of photon energies. This relaxes a host of experimental limitations related to the X-ray source and measurement sample, including collection time, minimum dopant concentration, source brilliance, and energy range. We describe the theoretical data sets and DeepONet construction and show that the resulting DeepONets produce EXAFS that recovers linear combination fits to experimental data with accuracy approaching the original ab initio calculations. We discuss the implications of our findings for minor constituent characterization and for understanding the information content of spectroscopic data more broadly, including how this approach might be applied to measured experimental spectra. In conclusion, to encourage similar efforts, the simulated X-ray spectra, machine learning, and fitting code are publicly available.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interaction of Aqueous Zn(II) with Hematite Nanoparticles and Microparticles. Part 1. EXAFS Study of Zn(II) Adsorption and Precipitation

Sorption of Zn(II){sub (aq)} on hematite (a-Fe{sub 2}O{sub 3}) nanoparticles (average diameter 10.5 nm) and microparticles (average diameter 550 nm) has been examined over a range of total Zn(II){sub (aq)} concentrations (0.4-7.6 mM) using Zn K-edge EXAFS spectroscopy and selective chemical extractions. When ZnCl{sub 2} aqueous solutions were reacted with hematite nanoparticles (HN) at pH 5.5, Zn(II) formed a mixture of four- and six-coordinated surface complexes [Zn(O,OH){sub 4} and Zn(O,OH){sub 6}] with an average Zn-O distance of 2.04 {+-} 0.02 {angstrom} at low sorption densities ({Gamma} {<=} 1.1 {mu}mol/m{sup 2}). On the basis of EXAFS-derived Zn-Fe{sup 3+} distances of (3.10-3.12) {+-} 0.02 {angstrom}, we conclude that both Zn(O,OH){sub 6} and Zn(O,OH){sub 4} adsorb on octahedral Fe{sup 3+}(O,OH){sub 6} or pentahedral Fe{sup 3+}(O,OH){sub 5} surface sites on HN as inner-sphere, mononuclear, bidentate, edge-sharing adsorption complexes at these low sorption densities. It is possible that polynuclear Zn complexes are also present because of the similarity of Zn and Fe backscattering. At higher Zn(II) sorption densities on hematite nanoparticles ({Gamma} {>=} 3.38 {mu}mol/m{sup 2}), we observed the formation of Zn(O,OH){sub 6} surface complexes, with an average Zn-O distance of 2.09 {+-} 0.02 {angstrom}, a Zn-Zn distance of 3.16 {+-} 0.02 {angstrom}, and a linear multiple-scattering feature at 6.12 {+-} 0.06 {angstrom}. Formation of a Zn(OH){sub 2(am)} precipitate for the higher sorption density samples ({Gamma} {>=} 3.38 {mu}mol/m{sup 2}) is suggested on the basis of comparison of the EXAFS spectra of the sorption samples with that of synthetic Zn(OH){sub 2(am)}. In contrast, EXAFS spectra of Zn(II) sorbed on hematite microparticles (HM) under similar experimental conditions showed no evidence of surface precipitates even at the same total [Zn(II){sub (aq)}] that resulted in precipitate formation in the nanoparticle system. Instead, Zn(O,OH){sub 6} octahedra (d(Zn-O) = 2.10 {+-} 0.02 {angstrom}) were found to sorb dominantly in an inner-sphere, bidentate, edge-sharing fashion on Fe{sup 3+}(O,OH){sub 6} octahedra at hematite microparticle surfaces, based on an EXAFS-derived Zn-Fe{sup 3+} distance of 3.44 {+-} 0.02 {angstrom}. CaCl{sub 2} selective extraction experiments showed that 10-15% of the sorbed Zn(II) was released from Zn/HN sorption samples, and about 40% was released from a Zn/HM sorption sample. These fractions of Zn(II) are interpreted as weakly bound, outer-sphere adsorption complexes. The combined EXAFS and selective chemical extraction results indicate that (1) both Zn(O,OH){sub 4} and Zn(O,OH){sub 6} adsorption complexes are present in the Zn/HN system, whereas dominantly Zn(O,OH){sub 6} adsorption complexes are present in the Zn/HM system; (2) a higher proportion of outer-sphere Zn(II) surface complexes is present in the Zn/HM system; and (3) Zn-containing precipitates similar to Zn(OH){sub 2(am)} form in the nanoparticle system but not in the microparticle system, suggesting a difference in reactivity of the hematite nanoparticles vs microparticles with respect to Zn(II){sub (aq)}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of EXAFS foil spectra from around the world

The EXAFS spectra of Cu and Pd foil from many different beamlines and synchrotrons are compared to address the dependence of the amplitude reduction factor (S{sub 0}{sup 2}) on beamline specific parameters. Even though S{sub 0}{sup 2} is the same parameter as the EXAFS coordination number, the value for S{sub 0}{sup 2} is given little attention, and is often unreported. The S{sub 0}{sup 2} often differs for the same material due to beamline and sample attributes, such that no importance is given to S{sub 0}{sup 2}-values within a general range of 0.7 to 1.1. EXAFS beamlines have evolved such that it should now be feasible to use standard S{sub 0}{sup 2} values for all EXAFS measurements of a specific elemental environment. This would allow for the determination of the imaginary energy (Ei) to account for broadening of the EXAFS signal rather than folding these errors into an effective S{sub 0}{sup 2}-value. To test this concept, we model 11 Cu-foil and 6 Pd-foil EXAFS spectra from around the world to compare the difference in S{sub 0}{sup 2}- and Ei-values.

43 PARTICLE ACCELERATORS↗

Comparison of EXAFS Foil Spectra from Around the World

The EXAFS spectra of Cu and Pd foil from many different beamlines and synchrotrons are compared to address the dependence of the amplitude reduction factor (S{sub 0}{sup 2}) on beamline specific parameters. Even though S{sub 0}{sup 2} is the same parameter as the EXAFS coordination number, the value for S{sub 0}{sup 2} is given little attention, and is often unreported. The S{sub 0}{sup 2} often differs for the same material due to beamline and sample attributes, such that no importance is given to S{sub 0}{sup 2}-values within a general range of 0.7 to 1.1. EXAFS beamlines have evolved such that it should now be feasible to use standard S{sub 0}{sup 2} values for all EXAFS measurements of a specific elemental environment. This would allow for the determination of the imaginary energy (Ei) to account for broadening of the EXAFS signal rather than folding these errors into an effective S{sub 0}{sup 2}-value. To test this concept, we model 11 Cu-foil and 6 Pd-foil EXAFS spectra from around the world to compare the difference in S{sub 0}{sup 2}- and Ei-values.

47 OTHER INSTRUMENTATION↗

The effect of self-consistent potentials on EXAFS analysis

A theory program intended for use with extended X-ray-absorption fine structure (EXAFS) spectroscopy and based on the popular FEFF8 is presented. It provides an application programming interface designed to make it easy to integrate high-quality theory into EXAFS analysis software. This new code is then used to examine the impact of self-consistent scattering potentials on EXAFS data analysis by methodical testing of theoretical fitting standards against a curated suite of measured EXAFS data. For each data set, the results of a fit are compared using a well characterized structural model and theoretical fitting standards computed both with and without self-consistent potentials. It is demonstrated that the use of self-consistent potentials has scant impact on the results of the EXAFS analysis.

Instruments & Instrumentation↗

Surface sensitive photoemission EXAFS: A new structural tool

A new technique for surface EXAFS has been developed. In this technique the absorption fine structure is observed by monitoring the photoelectrons emitted from core levels as a function of photon energy. The surface sensitivity is achieved by detecting elastic photoelectrons that escape to the vacuum from a few atomic layers near the surface. EXAFS from Mn 3p and F2s outer core levels in MnF2 were measured, the results were compared with transmission EXAFS from Mn ls core level and good agreement was found. This development is significant because: (1) almost all elements have suitable core levels of low binding energy; (2) since photopeaks from adjacent core levels do not cross as the photon energy is varied, the limitations imposed on other surface EXAFS techniques by this interference is removed. Auger electrons, which have fixed kinetic energies and so can cross photopeaks, will generally have low energies if they originate from outer core levels and be unlikely to appear in the EXAFS region of kinetic energies, i.e., in excess of about 50 eV; (3) VUV light is used, which greatly extends the usable range of photon energies; (4) more than one element in a solid may be studied with the same monochromator. The experiments were carried out on the VUV beam line U14A at NSLS.

Choudhary, K. M.↗

A Variation of the F-Test for Determining Statistical Relevance of Particular Parameters in EXAFS Fits

A general problem when fitting EXAFS data is determining whether particular parameters are statistically significant. The F-test is an excellent way of determining relevance in EXAFS because it only relies on the ratio of the fit residual of two possible models, and therefore the data errors approximately cancel. Although this test is widely used in crystallography (there, it is often called a 'Hamilton test') and has been properly applied to EXAFS data in the past, it is very rarely applied in EXAFS analysis. We have implemented a variation of the F-test adapted for EXAFS data analysis in the RSXAP analysis package, and demonstrate its applicability with a few examples, including determining whether a particular scattering shell is warranted, and differentiating between two possible species or two possible structures in a given shell.

36 MATERIALS SCIENCE↗

Limits of Detection for EXAFS Characterization of Heterogeneous Single-Atom Catalysts

Single-atom catalysts (SACs), consisting of individual metal atoms dispersed on a support, attract attention due to their unique reactivity, efficient use of precious metals, and precise chemical tunability. Characterization of the metal species is crucial to substantiate structure–function relationships. Authors often use—and referees often require—X-ray absorption spectroscopy (XAS) data to prove the absence of clustered metal (or metal oxide) structures after pre-treatment and under in situ or operando conditions. However, there has been no critical assessment of the limitations of XAS in substantiating such conclusive statements, which is particularly important given the potential outsized influence of minority catalyst structures in dictating catalytic activity. Here, in this article, we quantitatively assess the detection limits of XAS to identify metal (or metal oxide) clusters in samples containing predominantly single atoms by modeling the extended X-ray absorption fine structure (EXAFS) of mixtures of structures. We identified that a significant fraction of clusters can coexist with SAC active sites (e.g., ~10% metallic Pt or ~40% oxidized Pt clusters in Pt/CeO 2 SACs), while eluding detection via EXAFS with any statistical significance. To generalize these conclusions, a descriptor-based screening of bulk metal oxides using a continuous Cauchy wavelet transform was proposed that suggests certain materials for which differentiating atomically dispersed metal species and metal oxide clusters would be infeasible by EXAFS (e.g., ReO x ). Based on this analysis, we suggest best practices for the study of SACs using EXAFS and provide recommendations to ensure that conclusions do not outpace the evidence used to support them. In this rapidly expanding research area, rigorous characterization will lead to greater understanding of the behavior of SACs and ultimately improved catalytic materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EXAFS: New tool for study of battery and fuel cell materials

Extended X ray absorption fine structure (EXAFS) is a powerful technique for probing the local atomic structure of battery and fuel cell materials. The major advantages of EXAFS are that both the probe and the signal are X rays and the technique is element selective and applicable to all states of matter. This permits in situ studies of electrodes and determination of the structure of single components in composite electrodes, or even complete cells. EXAFS specifically probes short range order and yields coordination numbers, bond distances, and chemical identity of nearest neighbors. Thus, it is ideal for structural studies of ions in solution and the poorly crystallized materials that are often the active materials or catalysts in batteries and fuel cells. Studies on typical battery and fuel cell components are used to describe the technique and the capability of EXAFS as a structural tool in these applications. Typical experimental and data analysis procedures are outlined. The advantages and limitations of the technique are also briefly discussed.

Mcbreen, James↗

Robust Automatic EXAFS First-Shell Fits

Extended X-ray absorption fine structure (EXAFS) is a widely used technique for atomic structure determination. Fourier transformation connects EXAFS in k space and R space. However, determining the appropriate k-range for the transformation can be challenging, but critical for the first-shell fit. In this study, we present an automatic method to determine the k-range using the Larch package and a Python program. The first step is to estimate spectral noise across a series of k-ranges with a fixed minimum value and identify the optimal maximum value in the k-range (k max ). The k max is determined by an empirical noise threshold that marks the point where the noise level in the Fourier transformed spectrum changes dramatically. Using the obtained k max value, the first shell is modeled to determine the minimum k value (k min ) by optimizing the background function through alignment of the spectrum with theory. The optimal k min corresponds to the point of the minimum R-factor, which quantifies the difference between the experimental and fitted spectrum. Our method was tested on various typical datasets and yielded suitable k-ranges for Fourier transformation and accurate first-shell fits. This approach helps avoid unreliable, irreproducible data analysis, especially for noisy data from diluted samples, and enables robust automatic first-shell EXAFS fitting.

EXAFS analysis↗