Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENERGY SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Jet energy spectrum and substructure in $e^+e^–$ collisions at 91.2 GeV with ALEPH Archived Data

The first measurements of energy spectra and substructure of anti-k T jets in hadronic Z 0 decays in e + e – collisions are presented. The archived e + e – annihilation data at a center-of-mass energy of 91.2 GeV were collected with the ALEPH detector at LEP in 1994. In addition to inclusive jet and leading dijet energy spectra, various jet substructure observables are analyzed as a function of jet energy which includes groomed and ungroomed jet mass to jet energy ratios, groomed momentum sharing, and groomed jet radius. The results are compared with perturbative QCD calculations and predictions from the Sherpa, Herwig v7.1.5, Pythia6, Pythia8 and Pyquen event generators. The jet energy spectra agree with perturbative QCD calculations which include the treatment of logarithms of the jet radius and threshold logarithms. None of the event generators give a fully satisfactory description of the data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance assessment of PHITS simulations for the inverse-kinematic p( 7 Li,n) 7 Be reaction based on fast-neutron measurements with a diamond detector

The inverse-kinematics p( 7 Li,n) 7 Be reaction produces forward-focused neutron emission, offering enhanced usable flux and reduced shielding requirements. Reliable simulation of such neutron fields is essential for the development of compact accelerator-based neutron sources. In this study, a PHITS-based simulation framework for the reaction was experimentally assessed using fast-neutron measurements. Forward-directed neutrons were measured with a diamond neutron detector and quantitatively compared with simulations with newly prepared IK-Frag cross-section file based on the proton-induced reaction data in ENDF/B-VIII.1, TENDL-2023, and JENDL-4.0/HE. Measurements and simulations were performed for incident 7 Li 3+ energies ranging from 15.0 to 25.0 MeV using a 50 μm-thick polypropylene target. For all conditions, the PHITS-based simulation framework reproduced the deposited energy spectra at the correct order of magnitude. The comparison of deposited energy spectra in the diamond detector showed high correlation coefficients across all investigated energies, indicating reasonable agreement in spectral shape between simulations and measurements. This work represents an initial step toward establishing a benchmark for PHITS simulations of the inverse kinematic reaction between an incident lithium-ion and a proton target.

43 PARTICLE ACCELERATORS↗

Monte Carlo simulations demonstrating physics of equivalency of gamma, electron-beam, and X-ray for radiation sterilization

We report the sterilization of medical devices using the gamma rays from the decay of cobalt-60 has accumulated decades of experience of the performance of the materials and devices that are irradiated. The use of radiation using electron beams and x-rays has much less experience and this leads to questions of equivalency between these three technologies. Computer simulations were conducted to model the relevant physical processes of the interactions of each of the three forms of radiation in order to compare the spectra of electron energies at energies below 500 keV. It is predominantly the electrons below this threshold that produce the sterilization dose. No difference in energy spectra was seen between the three types of initial radiation. It is concluded that there is no energy dependent difference between gamma, e-beam, and x-ray for radiation sterilization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unraveling Fano noise and the partial-charge-collection effect in x-ray spectra below 1 keV

Fano noise, readout noise, and the partial-charge-collection (PCC) effect collectively contribute to the degradation of energy spectra in charge-coupled device (CCD) measurements, especially at low energies. Here, in this work, the x rays produced by the fluorescence of fluorine (677 eV) and aluminum (1486 eV) were recorded using a Skipper-CCD, which enabled the readout noise to be reduced to 0.2 e - . Based on an analytical description of photopeak shapes resulting from the convolution of the PCC effect and Fano noise, we achieved a precise characterization of the energy spectra. This description enabled us to disentangle and quantify the contributions from both Fano noise and the PCC effect. As a result, we determined the Fano factor and the electron-hole pair creation energy. Additionally, we estimated the PCC region of the sensor and, for the first time, experimentally observed the expected skewness of photopeaks at low energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A review of criticality dosimetry at the Y-12 National Security Complex and practical importance of dose accuracy in emergency response

A nuclear criticality results in the emission of both neutron and gamma radiation and can produce doses to personnel near the event that exceed 0.1 Gy (10 rad). The primary purpose of nuclear accident dosimetry is to rapidly identify affected personnel in need of prompt medical treatment and to reassure personnel who have been only minimally exposed. While accurate dosimetry is desired, it must be recognized that dose determinations made from whole-body dosimeters or simple triage methods are very rough estimates and contain significant uncertainties. Even when accounting for factors like varying neutron energy spectra, mean photon energies, body orientation within the radiation field, and transient effects on dosimeter response, etc., the end value is a dosimetric quantity defined for very specific radiological conditions and determined within a simple phantom usually at a single depth. Of more importance is the biological response to the radiation, which will vary by person and can be affected by the individual’s radiation sensitivity, age, gender, mass, and underlying health conditions. The overall biological, person-specific response to a given dose cannot be precisely determined except by patient symptom observation and individual biological dosimetry (e.g. chromosome analysis, lymphocyte ratios, etc.). This work describes and discusses the criticality accident dosimetry program at the Y-12 National Security Complex, a United States Department of Energy National Nuclear Security Administration facility. In conclusion, the primary goals of the Y-12 accident dosimetry program are, among others, the rapid identification of significantly exposed persons, prompt routing of exposed workers for medical evaluation and treatment, and the ultimate processing of dosimeters to assign doses to personnel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modeling Clustered DNA Damage by Ionizing Radiation Using Multinomial Damage Probabilities and Energy Imparted Spectra

Simple and complex clustered DNA damage represent the critical initial damage caused by radiation. In this paper, a multinomial probability model of clustered damage is developed with probabilities dependent on the energy imparted to DNA and surrounding water molecules. The model consists of four probabilities: (A) direct damage of sugar-phosphate moieties leading to SSB, (B) OH− radical formation with subsequent SSB and BD formation, (C) direct damage to DNA bases, and (D) energy imparted to histone proteins and other molecules in a volume not leading to SSB or BD. These probabilities are augmented by introducing probabilities for the relative location of SSB using a ≤10 bp criteria for a double-strand break (DSB) and for the possible success of a radical attack that leads to SSB or BD. Model predictions for electrons, 4He, and 12C ions are compared to the experimental data and show good agreement. Thus, the developed model allows an accurate and rapid computational method to predict simple and complex clustered DNA damage as a function of radiation quality and to explore the resulting challenges to DNA repair.

Biochemistry & Molecular Biology↗

Atomistic simulations and machine learning of solute grain boundary segregation in Mg alloys at finite temperatures

Understanding solute segregation thermodynamics is the first step in investigating grain boundary (GB) properties, such as strong yttrium (Y) effects on grain growth and texture evolution in micro-scale polycrystalline magnesium (Mg) alloys. To estimate the average GB segregation behavior in low-solute-concentration Mg alloys (e.g., 2 at.% Y), a state-of-the-art spectral approach is applied based on a per-site segregation energy spectrum for Y solute atoms at zero K obtained from molecular statistics (MS) simulations of ~10 4 GB sites in Mg symmetric tilt GBs (STGBs). Although selected MS simulation results are consistent with verification by density functional theory (DFT) calculations, estimates of average segregation tendency based on the zero-K energy spectrum deviate from experimental observations. To resolve this problem, thermodynamic integration (TI) methods based on molecular dynamics (MD) simulations are used to determine the per-site segregation free energies of Y at representative GB sites, which show contributions beyond harmonic approximations can be important for certain GB sites at high temperatures. A surrogate model of per-site segregation free energy is constructed from a small set of TI data points using stacking cross-validation regressors and physics-informed descriptors. This model is applied to predict the Y segregation free energy spectra for thousands of GB sites in Mg STGBs with uncertainty quantification. Finally, the average segregation tendency predicted by the spectral approach based on the free energy spectra agrees well (within the uncertainty range) with experimental observations for micro-scale polycrystalline Mg alloys at typical thermomechanical processing temperatures (500 ~ 800 K), where thermodynamic equilibrium states are likely to be achieved due to fast diffusion.

Atomistic simulations↗

Measurement of proton, deuteron, triton, and α particle emission after nuclear muon capture on Al, Si, and Ti with the AlCap experiment

Heavy charged particles after nuclear muon capture are an important nuclear physics background to the muon-to-electron conversion experiments Mu2e and COMET, which will search for charged lepton flavor violation at an unprecedented level of sensitivity. Here, the AlCap experiment aimed to measure the yield and energy spectra of protons, deuterons, tritons, and α particles emitted after the nuclear capture of muons stopped in Al, Si, and Ti in the low-energy range relevant for the muon-to-electron conversion experiments. Individual charged particle types were identified in layered silicon detector packages and their initial energy distributions were unfolded from the observed energy spectra.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy Spectrum of Ultrahigh-Energy Cosmic Rays across Declinations -90° to +44.8° as Measured at the Pierre Auger Observatory

The energy spectrum of cosmic rays above 2.5 EeV has been measured across the declination range - 9 0 ° ≤ δ ≤ + 44.8 ° using ∼ 310 000 events accrued at the Pierre Auger Observatory from an exposure of ( 104 900 ± 3 100 ) km 2 sr yr . No significant variations of energy spectra with declination are observed, after allowing or not for nonuniformities across the sky arising from the well-established dipolar anisotropies in the arrival directions of ultrahigh-energy cosmic rays. Here, the instep feature in the spectrum at ≃ 10 EeV reported previously is now established at a significance above 5 σ . Within the statistics, the energy spectra are indistinguishable across declinations so disfavoring an origin for the instep from a few distinctive sources.

Abdul Halim, A. [University of Adelaide]↗

Transition to Petschek Reconnection in Subrelativistic Pair Plasmas: Implications for Particle Acceleration

While relativistic magnetic reconnection in pair plasmas has emerged in recent years as a candidate for the origin of radiation from extreme astrophysical environments, the corresponding subrelativistic pair-plasma regime has remained less explored, leaving open the question of how relativistic physics affects reconnection. In this paper, we investigate the differences between these regimes by contrasting two-dimensional particle-in-cell simulations of reconnection in pair plasmas with relativistic magnetization (σ ≫ 1) and subrelativistic magnetization (σ < 1). By utilizing unprecedentedly large domain sizes and outflow boundary conditions, we demonstrate that lowering the magnetization results in a change in the reconnection geometry from a plasmoid chain to a Petschek geometry, where laminar exhausts bounded by slow-mode shocks emanate from a single diffusion region. We attribute this change to the reduced plasmoid production rate in the low-σ case: When the secondary tearing rate is sufficiently low, plasmoids are too few in number to prevent the system from relaxing into a stable Petschek configuration. This geometric change also affects particle energization: We show that while high-σ plasmoid chains generate power-law energy spectra, low-σ Petschek exhausts merely heat incoming plasma and yield negligible nonthermal acceleration. These results have implications for predicting the global current sheet geometry and the resulting energy spectra in a variety of systems.

Plasma astrophysics↗

Filament Formation in TaO x Thin Films for Memristor Device Application: Modeling Electron Energy Loss Spectra and Electron Transport

Abstract Although understanding filament formation in oxide‐based memristive devices by theory has emerged, there are still fundamental unanswered questions. Importantly, for practical application of thin films the material in its amorphous state is to be considered, but mostly lacking so far, and details on sub‐stoichiometry are also scarce. To gain insight into the optical and electronic properties of sub‐stoichiometric amorphous tantalum oxide (TaO x ), the electron energy loss spectrum (EELS) of model systems is characterized theoretically and electron transport characteristics are analyzed in detail. Calculated blue‐shifts by increasing sub‐stoichiometry explained the measurements, potentially suggesting estimation of oxygen vacancy concentrations through EEL spectra. Electron transport results based on TaO x material models validated by EELS measurements show that oxygen vacancy filamentary paths are initiated at low bias upon increasing sub‐stoichiometry yet noting an interplay with the local amorphous structure. Contact resistances at interfaces of the TaO x switching layer and a tantalum scavenging layer or titanium nitride electrode are quantified, indicating the possibility for either oxygen vacancy‐ or metal cluster‐based conduction mechanisms at the interface. The computational work, combined with experimental characterization for validation, provides a basis for investigating effects of sub‐stoichiometry on filament formation in TaO x thin film memristive devices.

36 MATERIALS SCIENCE↗

A Novel Dosimetry Method for Small Animal Irradiators Using 3D-printed Mouse Phantoms and Alanine Dosimeters

Abstract Accurate dosimetry is a crucial component of small animal and preclinical irradiation studies. Various dosimetry options are available but fail to characterize complex geometries and variable energy spectra of modern x-ray irradiators accurately. These options also lack national/international standards of recognition. This paper presents a novel dosimetry system, Dosequate, which uses murine phantoms embedded with alanine dosimeters and paired with x-ray energy spectra corrections to deliver consistent and accurate dosimetry measurements. This study compares Dosequate measurements against a Precision X-RAD 320 internal ion chamber and the treatment planning system of an Xstrahl Small Animal Radiation Research Platform. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. The Dosequate dosimetry method provides a robust and standardized approach for measuring absorbed dose in small animal irradiators. Its accuracy, reproducibility, and ability to account for complex irradiation geometries make it a valuable tool for preclinical research. This system has the potential to significantly improve the intercomparability of studies across different facilities and enhance the reliability of results.

Environmental Sciences & Ecology↗

Optimization of the generator coordinate method with machine-learning techniques for nuclear spectra and neutrinoless double- β decay: Ridge regression for nuclei with axial deformation

The generator coordinate method (GCM) is an important tool of choice for modeling large-amplitude collective motion in atomic nuclei. The computational complexity of the GCM increases rapidly with the number of collective coordinates. It imposes a strong restriction on the applicability of the method. In this work, we propose a subspace-reduction algorithm that employs optimal statistical ML models as surrogates for exact quantum-number projection calculations for norm and Hamiltonian kernels. The model space of the original GCM is reduced to a subspace relevant for nuclear low energy spectra and the NME of ground state to ground state 0νββ decay based on the orthogonality condition (OC) and the energy-transition-orthogonality procedure (ENTROP), respectively. For simplicity, the polynomial ridge regression (RR) algorithm is used to learn the norm and Hamiltonian kernels of axially deformed configurations. The efficiency and accuracy of this algorithm are illustrated for 76 Ge and 76 Se by comparing results obtained using the optimal RR models to direct GCM calculations. The low-lying energy spectra of 76 Ge and 76 Se, as well as the 0νββ-decay NME between their ground states, are computed. Furthermore, the results show that the performance of the GCM+OC/ENTROP+RR is more robust than that of the GCM+RR alone, and the former can reproduce the results of the original GCM calculation accurately with a significantly reduced computational cost.

59 ≤ A ≤ 89↗

A simulation pipeline for fast neutron imaging and spectroscopy using quantified detector attributes

Radiation imaging capabilities, essential in the nuclear nonproliferation regime, facilitate source localization and, in certain cases, spectroscopy. Scatter-based neutron cameras, which can measure the neutron signatures from special nuclear material, hold particular interest. Systems incorporating organic scintillators can extract neutron energy spectra, potentially distinguishing fission neutron sources from others, such as alpha-neutron sources. The development and testing of a scatter-based neutron imager, however, can be challenging without having an accurate simulation model or first constructing a prototype. This work describes a simulation pipeline that takes output from MCNPX-PoliMi simulations and creates the expected back-projection neutron images and neutron energy spectra. This pipeline was developed to improve the modeling of fast neutron imagers and bridge the current gap in literature, which predominantly focuses on gamma-ray Compton imager models. This work also reports on the significance of various real-world system considerations and their effects on the simulated detector responses. The pipeline was verified and validated with experimental data collected using a 252 Cf spontaneous fission source using a fast neutron scattering imager developed at the University of Michigan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Probe 23A Pre-Shot report

The Multi-Probe Radiography campaign will field a full day of experiments at the Omega EP laser facility. The experiments will consist of shots that alternate between Omega EP’s two short-pulse laser beams to generate proton and deuteron beams from a variety of film and foam targets. The proton beam is intended to be used as a radiographic source, while the deuteron beam will be used as the pitcher in a pitcher-catcher neutron-generation concept. For the proton beam, our goal is to characterize the angular distribution and energy spectra of unwanted x-rays that are generated during proton acceleration and were found to be problematic for simultaneous radiography in MP-22A. As part of this primary goal, we will test whether an x-ray shield, XBLK, can be used to prevent these x-rays from impacting other x-ray diagnostics. For the deuteron beam, our primary goal is to characterize the energy spectra and beam profile of deuterons accelerated from CD foils and foams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectral Properties of Globally Distributed ENA Fluxes across Diverse Regions of the Heliosphere

This study analyzes energetic neutral atom (ENA) spectral properties across distinct regions of globally distributed flux (GDF) sky maps, using Interstellar Boundary Explorer data from a full solar cycle, corrected for time dispersion. By time-shifting the data to the heliosheath using GDF source distances from D. B. Reisenfeld et al., we achieve a more accurate representation of heliosheath GDF energy spectra. We quantify ENA spectral characteristics, heliosheath line-of-sight-integrated proton pressure, and heliosheath proton temperature, comparing these to solar wind properties at 1 au and interplanetary scintillation-derived solar wind data. Our findings show that the spectral index is generally anticorrelated with heliosheath proton temperature and pressure, except in the central tail, where a partial positive correlation is observed. The lowest spectral index values occur when high-latitude heliosheath regions are dominated by fast solar wind from polar coronal holes. The south pole exhibits the flattest energy spectra due to plasma heating from both fast solar wind and a late-2014 pressure pulse. The central tail shows shorter variability (5–6 yr) for spectral index and heliosheath proton temperature, while proton pressure follows the 11 yr solar cycle. Most spectral shapes exhibit a “knee” distribution, peaking during solar maximum, with an “ankle” shape observed only at the south pole during solar cycle transitions. Asymmetry in proton pressure in the lobes is driven by the draping effect of the local interstellar magnetic field. This study provides insights into the energetic properties of GDF across the heliosphere, enhancing our understanding of the heliospheric environment.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlated Signal Analysis for Nuclear Emergency Response

In the context of nuclear emergency response (NER) scenarios, the critical task is to quickly identify a "black box" as a potential threat, as failing to do so could have catastrophic consequences. Techniques for passive assay of a “black box” typically include gamma-ray spectroscopy and neutron coincidence/multiplicity counting. However, there are significant challenges associated with these type of measurements. First, the presence of intervening materials can obstruct the detection of relevant signatures. Second, the presence of strong non-fission neutron sources, like (α, n) emitters, can add uncertainties to the neutron multiplicity analysis. In our LDRD-MFR Phase II work, a portable neutron spectrometer, called the Compact Fast Neutron Spectrometer (CFNS), was developed for NER applications. The CFNS system leverages information-rich neutron energy spectra to derive actionable information. This work investigates the use of correlated signals in the CFNS from special nuclear material (SNM) to characterize physical properties, such as intervening shielding material and fission to non-fission neutron contributions. In this report, the Phase II results from bulk SNM measurements at the National Criticality Experiments Research Center (NCERC) are briefly discussed along with the motivation for this work. Afterwards, simulations using the MCNPX-PoliMi transport code are discussed, which were used to expand our correlated signal study. Signal triggered analysis for neutron multiplicity extraction will also be discussed. Lastly, the use neutron-photon correlations for intervening material identification are shown, along with the use of correlated neutron energy spectra for α-ratio extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗