CSEWG Meeting Minutes
Work has been done at LANL to validate various updated evaluations from ENDF/BVIII.1b0 including: Fe, Cu, Si, U, Pu. Continuous energy tables were processed with NJOY2016 and output to ACE files. For non-Pu legacy critical benchmarks, all calculations were within the experimental benchmark uncertainty, with some benchmarks having shown lower bias using ENDF/B-VIII.1b0. In HST systems, ENDF/B-VIII.0 shows reasonable results above the thermal leakage fraction. ENDF/B-VIII.0.1 is doing slightly worse than ENDF/B- VIII.0. b0.2 and it also includes a new 19 F evaluation, so more work is needed to examine its impact. 233 U thermal and intermediate bare and water-reflected benchmarks agree well with ENDF/B-VIII.0. From ENDF/B-VIII.0 to ENDF/B-VIII.0b0.1, HMF-007 C/E are increasing and the new 19 F evaluation is helping the HMF-007 cases containing Teflon which have historically had high C/E. The Pu legacy benchmark suite is within experimental uncertainty with the exception of THOR. The INDEN evaluation followed by LANL gave the lowest mean absolute bias, but it remains difficult to make a determination on which Pu evaluation is the best. INDEN performs slightly better for the JEZEBEL series, while the LANL Pu evaluation is better for THOR and flattop benchmarks. For the PMI benchmark series INDEN outperforms the LLNL evaluation. For the PST benchmark series ENDF/B-VIII.0 and LLNL Pu evaluations are better than the INDEN evaluation. C/E ratios for Jezebel and Godiva reaction rate ratios show all the Pu evaluations are very close to one another, making it again difficult to say which is best. When examining neutron reactor kinetics parameters, each Pu evaluation is once again very close. Each individual Pu evaluation seems to have advantages in their own applications.