Overview and status of EMI Measurement and Characterization on the Z-Machine.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Electrically conductive composites are emerging across diverse industries such as electronic, automotive, aerospace, advanced air mobility, biomedical, infrastructure, defense and security offering static charge dissipation, electromagnetic interference shielding, lighting protection, sensing, dicing, corrosion monitoring, etc. Conductivity enhanced composites provide several advantages compared to conventional metals including weight reduction, corrosion resistance, energy efficient processability, tunable properties and multifunctionality. Polymers are typically insulating in nature and require conducting filler for electron transport. However, dispersion and polymer-filler interphases are critical and often disrupt conducting pathways. Besides, conductive fillers such as graphene, carbon nanotube, MXene, silver nanowire, etc. are expensive, limiting their wide adoption in composite industry. On the other hand, a limited number of intrinsically conductive polymers are available among which polyaniline (PANI) has been widely studied due to its high conductivity, thermal and chemical stability. However, PANI is difficult to process and exhibits weak mechanical properties. In brief, there is a significant demand for electrically conductive polymer formulation with cost-effective conducting fillers that offer processability in scale to expand the market of conductivity enhanced materials.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Energy management information systems (EMIS) are a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance. Critical systems are often integrated with or operate on the same networks as EMIS scope systems, necessitating stable, continuous, and secure communication. When connecting EMIS to building automation and utility control systems, there are also many physical assets that could cause harm to the building and its occupants if a malicious act or human error were introduced. It is imperative to ensure all EMIS scope systems are connected securely to the EMIS and do not open vulnerable pathways to other facility networks and operations. The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of EMIS at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of required EMIS cybersecurity standards for compliance and authority to operate along with additional recommendations.
Energy management information systems (EMIS) are a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance. Critical systems are often integrated with or operate on the same networks as EMIS scope systems, necessitating stable, continuous, and secure communication. When connecting EMIS to building automation and utility control systems, there are also many physical assets that could cause harm to the building and its occupants if a malicious act or human error were introduced. It is imperative to ensure all EMIS scope systems are connected securely to the EMIS and do not open vulnerable pathways to other facility networks and operations. The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of EMIS at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of required EMIS cybersecurity standards for compliance and authority to operate along with additional recommendations.
This research focuses on electromagnetic interference (EMI) / electromagnetic compatibility (EMC) design and analysis in power electronics systems. To limit the EMI under the standards, different methods and strategies are investigated. Parasitic parameters of high frequency (HF) transformer are analyzed using a novel analytical method, finite element method (FEM), and experimental measurements for different structures and windings arrangements. Also, the magnetic field, electric field, electric displacement, and electric potential distribution are simulated and analyzed. Moreover, a high voltage system is considered and analyzed to improve the EMC. The EMI propagation paths are analyzed. The EMI noise level of the system is obtained and compared to the IEC61800-3 standard. To improve the EMC, the parasitic parameters of the transformer, as the main path of EMI circulation, are analyzed and optimized to block the propagation. Furthermore, the geometry structure of the HF transformer is optimized to lower the parasitics in the system. Three pareto-optimal techniques are investigated for the optimization. The models and results are verified by 3D-FEM and experimental results for several given scenarios. Furthermore, the EMC modeling and conducted EMI analysis are developed for a system including an AC-DC-DC power supply (rectifier and dual active bridge (DAB) converter). Moreover, the common mode (CM) EMI noise propagation through the system is discussed and the noise sources and effect of components on the noise are analyzed. Additionally, the CM impedance of different parts of the system and the noise levels are discussed. Finally, EMI attenuation techniques were applied to the system.
Abstract Subsurface heterogeneity influences watershed hydrology strongly but remains difficult to characterize at catchment scales with sparse and costly field data. Geophysical surveys such as electromagnetic induction (EMI) provide local spatial subsurface images yet scaling them to watershed scales and converting EMI‐derived resistivity into hydraulic properties remains a challenge. We present a Model–Experiment (ModEx) framework that integrates limited EMI data with machine learning (ML) and hydrologic modeling to improve process representation and guide field investigations. Sparse EMI surveys were scaled to the catchment scale using a Random Forest model, and the resulting resistivity fields were combined with nearby borehole constraints to parameterize a hydrologic model. The EMI‐informed hydrological simulations improved predictions of streamflow sustained by subsurface flow and shallow saturation patterns. By combining EMI data and ML with hydrologic modeling, the ModEx framework guides future subsurface surveys, providing a transferable and efficient strategy for data–model integration across diverse watersheds. Plain Language Summary Mapping the underground network of soil and rock that controls water is essential for predicting floods and droughts, but seeing underground is difficult and expensive. We cannot drill everywhere, so scientists use geophysical tools to scan broad areas. There are two key challenges: these geophysical scans are often sparse across the whole watershed, and the geophysical data is hard to translate into water‐related properties. We used artificial intelligence to solve these problems. We taught a computer to find patterns linking the limited geophysical data to the land surface properties. This allowed it to fill in the gaps and create a complete, useful subsurface map for the entire watershed. This new map improves hydrologic simulations, leading to more accurate predictions of water movement in the watershed. It also helps scientists build better models with less data and generates a priority map showing where to measure next, making future investigations more efficient. Key Points Limited EMI scaled with ML improves catchment‐scale subsurface parameterization for hydrologic models The framework integrates hydrologic modeling with limited geophysical data to support subsurface investigation design ModEx framework offers a transferable data–model integration strategy that quantifies and reduces uncertainty guiding watershed studies
The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of Energy Management Information Systems (EMIS) at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. The use of standard naming conventions and a metadata schema, which may be referred to as 'data tags,' improves the ability of the EMIS to consistently analyze, visualize, and derive value from operational data. To help address these issues, this fact sheet highlights best practices for use of metadata in an EMIS stack, which can significantly reduce the initial time required to deploy an EMIS.
Lightweight, flexible polymer composites are widely adopted in modern electronic devices and systems for high-efficiency electromagnetic interference (EMI) shielding. Reinforcing polymer composites with conductive fillers offers a promising alternative to conventional metal-based shielding material thanks to their low density, tunable properties, and flexibility. Herein, lightweight, flexible ultra-high molecular weight polyethylene composite films reinforced with recycled carbon fibers (rCFs) and carbon-based nanofillers, including graphene nanoplatelets (GNPs) and carbon nanotubes, are reported for EMI shielding applications. The incorporation of these nanofillers significantly reduces the required content of rCFs and improves processability while maintaining comparable shielding effectiveness. The addition of these nanofillers with rCFs enhances the EMI shielding effectiveness by up to 15 dB. Incorporating 1 wt% GNPs can replace 5 wt% rCFs and achieve comparable EMI shielding performance, while 5 wt% of either nanofillers can substitute for 10 wt% rCFs. Numerical modeling of electromagnetic wave transmission reveals that increasing nanofiller concentrations enhances both reflection and absorption losses, with absorption consistently dominating across all levels. Furthermore, this study not only provides insight into the synergistic contributions of rCFs and carbon nanofillers to shielding effectiveness but also paves the way for the design of sustainable, lightweight EMI shielding composite films for applications in electric vehicles, medical equipment, and portable electronics.
Fact sheet highlights best practices for metadata schemas and standard naming conventions, which improve the ability of an energy management information system (EMIS) to consistently analyze, visualize, and derive value from operational data. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of best practices for using metadata in an EMIS stack, which can significantly reduce the initial time required to deploy an EMIS.
Not Available
The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a newly developed diagnostic for imaging time resolved diffraction in experiments at the National Ignition Facility (NIF). It builds on the successes of its predecessor, the Gated Diffraction Development Diagnostic (G3D). The FIDDLE was designed to support eight Daedalus version 2 sensors (six more hCMOS sensors than any other hCMOS-based diagnostic in NIF to date) and an integrated streak camera. We will review the electrical requirements, design, and performance of the electrical subsystems that were created to support this large number of cameras in the FIDDLE. The analysis of the data that the FIDDLE is intended to collect relies heavily on the accurate and well-understood timing of each sensor. We report camera-to-camera timing jitter of less than 100 ps rms and sensor integration times of 2.2 ns FWHM in 2-2 timing mode. Additionally, diffraction experiments on the NIF produce electric fields (EMI) on the order of 1 kV/m, which have been observed to negatively impact the performance of some electrical components of the FIDDLE. We report on the results of testing hCMOS camera electronics in a similar EMI environment generated in an offline lab. In addition, we also summarize the use of a novel approach to using a vector network analyzer as an EMI leak detector to understand and reduce the negative impacts of EMI on the FIDDLE.
Here, the proliferation of electronic devices has made electromagnetic interference (EMI) shielding an exponentially growing business. Regulatory requirements change constantly as new technologies continue to emerge. Innovations in materials and new advances in shielding implementation techniques are needed to pass regulatory compliance tests at an affordable cost. Here, we print various EMI shielding materials such as copper, silver and a composite of copper with Fe 3 O 4 using plasma jet printing. Printing enables shields only a few microns thick capable of high shielding effectiveness. Copper's EMI shielding performance is primarily contributed by reflection mechanism, as expected and this is known to cause secondary pollution. A Green Index for EMI shielding, given by the ratio of absorption and reflection contributions to shielding, indicates values lower than 0.1 for printed copper films.