Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRON SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Record quantum efficiency from strain compensated superlattice GaAs/GaAsP photocathode for spin polarized electron source

Photocathodes based on GaAs and other III–V semiconductors are capable of producing highly spin-polarized electron beams. GaAs/GaAsP superlattice photocathodes exhibit high spin polarization; however, the quantum efficiency (QE) is limited to 1% or less. To increase the QE, we fabricated a GaAs/GaAsP superlattice photocathode with a Distributed Bragg Reflector (DBR) underneath. This configuration creates a Fabry–Pérot cavity between the DBR and GaAs surface, which enhances the absorption of incident light and, consequently, the QE. These photocathode structures were grown using molecular beam epitaxy and achieved record quantum efficiencies exceeding 15% and electron spin polarization of about 75% when illuminated with near-bandgap photon energies.

47 OTHER INSTRUMENTATION↗

Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal electron sources

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High figure of merit spin polarized electron sources grown via MOCVD

Spin polarized photocathodes are key to the future operation of electron accelerators such as the ones at Thomas Jefferson National Accelerator Facility and Brookhaven National Laboratory. Currently, these photocathodes come in short supply due to limited production by molecular beam epitaxy. By developing a process to implement similar structures using metal organic chemical vapor deposition, the availability of these devices can be increased. Here, in this paper, we detail the implementation of recent photocathode advancements via metal organic chemical vapor deposition process and show an improvement in both polarization and quantum efficiency of our devices compared to those fabricated via molecular beam epitaxy, with devices reaching 82% polarization and 2.9% quantum efficiency.

43 PARTICLE ACCELERATORS↗

Scalings of laser-driven MeV electron sources with relativistic multi-picosecond laser pulses

We investigate the generation of MeV electrons in relativistic multi-picosecond laser–solid interactions, using two-dimensional particle-in-cell simulations. Scanning a parameter space of intensities from 10 18 to 10 20 W/cm 2 and pulse durations between 100 fs and 10 ps, we discuss scalings of the effective hot electron temperature and MeV electron dose relevant to applications, as well as the direct laser acceleration mechanism that drives electrons to energies much higher than the ponderomotive potential of the laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Building better electron sources with graphene

This report is a press release and discusses how "Graphene substrates can be reused repeatedly for photocathodes that emit high brightness electron beams in electron microscopes and accelerators."

36 MATERIALS SCIENCE↗

Spin-Polarized Electron Sources Based on Group II-VI Compounds Grown by Atomic Layer Deposition

This project explored ALD as an alternative growth technique for II–VI photocathodes and assessed CdTe for spin-polarized electron production. Working with BNL (Cultrera group), we established the workflow to measure QE and spin polarization using BNL’s Mott polarimeter, and we prepared both conventional Cs/O NEA activation and a heterostructure NEA route leveraging an ultrathin Cs2Te overlayer. The latter provides a pragmatic activation alternative while maintaining photoexcitation primarily in CdTe.

43 PARTICLE ACCELERATORS↗

Development of electron source feedback for enhanced X-ray beam stability at NSLS-II

Future synchrotron light sources are being designed to deliver significantly higher brightness and coherence, enabling faster scanning and more advanced imaging techniques. However, realizing these capabilities requires improved X-ray beam stability, as vibrations directly limit measurement accuracy and image quality. At the NSLS-II Hard X-ray Nanoprobe (HXN), a local mechanical feedback system mitigates low-frequency motion but provides only limited suppression of dominant vibrations at 27 Hz and 120 Hz. To address this limitation, this work explores the use of the electron beam itself as the actuator for feedback by integrating X-ray beam position monitor signals into the fast orbit feedback system through a dedicated electrometer. Experimental results show that this approach effectively suppresses the dominant vibration peaks and enhances stability at the focusing point. Benchmark ptychography measurements further confirm that electron-beam-based feedback reduces background fluctuations and mitigates vibration-induced artifacts under fast-scanning conditions. These results establish the feasibility of using the electron beam as a feedback actuator for next-generation synchrotron applications and provide an experimental assessment of its potential and limitations.

36 MATERIALS SCIENCE↗

High-current electron sources for Superconducting Radiofrequency injectors

Accelerators are finding increasing use in numerous fields such as medicine, industry accelerator-based nuclear energy programs and others. A recent survey reveals only 20 high-energy accelerators worldwide serve elementary-particle physics while thousands of accelerators are routinely used in hospitals and industry (packaging, food sterilization, etc.).

43 PARTICLE ACCELERATORS↗