Electron probe microanalyses of minerals and glasses in Apollo 11 lunar samples
Apollo 11 lunar igneous rocks minerals and glassy phases characteristics, using electron probe microanalysis
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Apollo 11 lunar igneous rocks minerals and glassy phases characteristics, using electron probe microanalysis
Chemical composition of major and minor phases in two specimens of Odessa iron meteorite analyzed by electron probe
Electron beam probe measurements of rotational and vibrational temperatures in static low-density air
An evaluation of precision and accuracy will be presented for representative semiconductor and silicate compositions. The accuracy of electron-probe analysis depends on high precision measurements and instrumental calibration, as well as correction algorithms and fundamental parameter data sets. A critical assessment of correction algorithms and mass absorption coefficient data sets can be made using the alpha factor technique. Alpha factor analysis can be used to identify systematic errors in data sets and also of microprobe standards used for calibration.
We present a comparison of two different techniques: Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) and wavelength-dispersive X-Ray Spectroscopy by electron probe microanalyzer (EPMA) for obtaining Mg/Ca ratios in individual foraminifera shells. The goal is to assess the use of EPMA as an alternative technique for Mg/Ca analyses of single foraminiferal calcite shells. Foraminifera obtained from sediments (benthic, Uvigerina spp.) and from plankton tows (planktonic, Orbulina universa) were analyzed. All specimens were prepared in epoxy mounts and exposed in cross-section such that multiple high-resolution analyses could be completed on the shells using both techniques. We examined our data using statistical methods designed for the assessment and comparison of measurement techniques. In the case of Uvigerina, the mean difference for ratios obtained using EPMA and LA-ICP-MS is very small (−0.046 mmol mol−1) and scale independent. The Limits of Agreement (LoA, the standard deviation of the bias plus the mean bias) is [−0.315, 0.223] mmol mol−1. For samples with ratios lower than 13 mmol mol−1, we found a mean EPMA–LA-ICP-MS bias of −2.44 mmol mol−1 and a corresponding LoA of [−3.85, −1.04] mmol mol−1. For ratios higher than 13 mmol mol−1, there appears to be a scale dependent bias, meaning that the EPMA measured ratios become progressively larger than those of LA-ICP-MS as the Mg/Ca ratio increases, so the mean bias and LoA metrics are not meaningful. Results indicate that it is possible to use EPMA to collect Mg/Ca data, if the ratios are lower than ∼13 mmol mol−1.
Electron beam density probe calibration for earth atmospheric reentry vehicles communication
The author summarizes the results of theoretical studies of the interaction of an uninsulated, spherical, high voltage (10's of KV positive) probe with the ionospheric environment. The focus of this effort was the phenomenon of electron trapping and its implications for breakdown processes (collisional regime) and the current-voltage relationship governing current collection (collisionless regime) in space-based pulsed power systems with high voltage components exposed to space, e.g., the SPEAR I experiment.
The technique developed by Kornacki (1984) for identifying group II Ca/Al-rich inclusions in carbonaceous chondrites by electron-microprobe analysis of the ZrO2 or Y2O3 content of their perovskite component is demonstrated using material from 20 Allende inclusions. The results are presented in tables and graphs and compared with findings obtained by other procedures. Group II inclusions are found to have perovskites generally containing less than 0.10 wt pct ZrO2 and/or Y2O3 (average of several grains), while those of groups I, III, V, and VI have more than 0.25 wt pct ZrO2. Analysis of data on eight Allende Ca/Al-rich inclusions shows that 75 percent of the fine-grained inclusions belong to group II. The implications of these findings for fractionation processes in the primitive solar nebula are indicated.
Refractive index irregularities in the equatorial mesosphere have been investigated using both the Jicamarca VHF radar and a rocket-borne Langmuir probe launched from Punta Lobos, Peru. On February 27, 1983, a single layer of turbulence was observed in the upper mesosphere by both experiments. There is very good agreement between the observed radar echo power and the radar scattering cross section calculated from the rocket data when these are interpreted in the context of isotropic turbulence. The inner and outer scales of turbulence have been calculated from both the radar and the rocket data, and good agreement is found. The radar data show indications of large-scale vortices in the layer of irregularities. Rocket data show that the inner scale of turbulence in the upper mesosphere is a few tens of meters and that the Jicamarca radar Bragg wavelength (3 m) is well within the viscous subrange of turbulence in this altitude range. The spectral index in the inertial subrange is close to -5/3, changing to about - 7 at higher wave numbers. Energy dissipation rate in the layer was calculated to be 0.05 W/kg, in good agreement with previous estimates.
Instrument purchase requirements and dialogue with manufacturers have established hardware parameters for alignment, stability, and reproducibility, which have helped improve the precision and accuracy of electron microprobe analysis (EPMA). The development of correction algorithms and the accurate solution to quantitative analysis problems requires the minimization of systematic errors and relies on internally consistent data sets. Improved hardware and computer systems have resulted in better automation of vacuum systems, stage and wavelength-dispersive spectrometer (WDS) mechanisms, and x-ray detector systems which have improved instrument stability and precision. Improved software now allows extended automated runs involving diverse setups and better integrates digital imaging and quantitative analysis. However, instrumental performance is not regularly maintained, as WDS are aligned and calibrated during installation but few laboratories appear to check and maintain this calibration. In particular, detector deadtime (DT) data is typically assumed rather than measured, due primarily to the difficulty and inconvenience of the measurement process. This is a source of fundamental systematic error in many microprobe laboratories and is unknown to the analyst, as the magnitude of DT correction is not listed in output by microprobe operating systems. The analyst must remain vigilant to deviations in instrumental alignment and calibration, and microprobe system software must conveniently verify the necessary parameters. Microanalysis of mission critical materials requires an ongoing demonstration of instrumental calibration. Possible approaches to improvements in instrument calibration, quality control, and accuracy will be discussed. Development of a set of core requirements based on discussions with users, researchers, and manufacturers can yield documents that improve and unify the methods by which instruments can be calibrated. These results can be used to continue improvements of EPMA.
Explore the source record for details and available documents.
Computer program for metallurgical and geological data reductions
Microwave electron density probe based on plasma- electromagnetic field interaction
Electron density and temperature in inviscid flow and nozzle-wall boundary layer, measured with constant bias-voltage and swept-voltage RAM probes
Hot wire electron emissive probes for potential measurements in quiescent plasmas, noting plasma densities, emission levels, etc
The Orbiter Electron Temperature Probe (OETP) instrumentation and measurement technique has been designed to perform in-situ measurements of electron temperature and electron and ion density in the ionosphere of Venus. Adaptive sweep voltage circuitry continuously tracks the changing electron temperature and spacecraft potential while auto-ranging electrometers adjust their gain in response to the changing plasma density. Control signals used in the instrument to achieve this automatic tracking provide a continuous monitor of the ionospheric parameters without telemetering each volt-ampere curve. Internal data storage permits high data rate sampling of selected raw characteristic curves for low rate transmission to earth. These curves are used to verify or correct the inflight processed data. Sample in orbit measurements are presented to demonstrate instrument performance.
Test probe, in conjunction with standard equipment, tests axial-lead electronic components in their original packages. The probe can be modified to test any electronic component with automatic or nonautomatic equipment.
The Pioneer Venus orbiter electron temperature probe was used to obtain altitude profiles of electron temperature and density in the ionosphere of Venus. Elevated temperatures at times of low solar wind flux might indicate support for a certain model. According to this model, less than 5% of the solar wind energy is deposited at the ionopause and is conducted downward through an unmagnetized ionosphere to the region below 200 km where electron cooling to the neutral atmosphere proceeds rapidly. The patterns of electron temperatures and densities at higher solar wind fluxes are considered, the variability of the ionopause height in the late afternoon is noted, and the role of an induced magnetic barrier in the neighborhood of the ionopause is discussed.