Engineering PapersSearch

SEARCH · Engineering Papers

Results for “ELECTRON MULTIPLIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Construction and evaluation of an imaging focussed-mesh electron multiplier for space instrumentation

A focused-mesh electron multiplier (FMEM) has been combined with a wedge and strip position-sensitive anode to create a novel detector that is considered likely to have a number of applications in space astronomy and laboratory image sensing. Results from the first application of a wedge and strip anode to an FMEM are presented including spatial resolution, spatial linearity, background rate, and pulse risetime. The converted multiplier retains the attributes of an FMEM that made it attractive in the first place, such as low background, high speed, and high dynamic range.

Vallerga, J.

Properties of the Flight Model Gas Electron Multiplier for the GEMS Mission

We present the gain properties of the gas electron multiplier (GEM) foil in pure dimethyl ether (DME) at 190 Torr. The GEM is one of the micro pattern gas detectors and it is adopted as a key part of the X-ray polarimeter for the GEMS mission. The X-ray polarimeter is a time projection chamber operating in pure DME gas at 190 Torr. We describe experimental results of (1) the maximum gain the GEM can achieve without any discharges, (2) the linearity of the energy scale for the GEM operation, and (3) the two-dimensional gain variation of the active area. First, our experiment with 6.4 keV X-ray irradiation of the whole GEM area demonstrates that the maximum effective gain is 2 x 10(exp 4) with the applied voltage of 580 V. Second, the measured energy scale is linear among three energies of 4.5, 6.4, and 8.0 keV. Third, the two-dimensional gain mapping test derives the standard deviation of the gain variability of 7% across the active area.

gas electron multiplier (GEM)

Development of Resistive Electrode Gas Electron Multiplier (RE-GEM)

We successfully produced Resistive-Electrode Gas Electron Multiplier (RE-GEM) which has resistive electrodes instead of the metal ones which are employed for the standard GEM foils. RE-GEM has a resistive electrode of 25 micron-thick and an insulator layer of 100 micron-thick. The hole structure of RE-GEM is a single conical with the wider and narrower hole diameters of 80 micron and 60 micron, respectively. A hole pitch of RE-GEM is 140 micron. We obtained the maximum gain of about 600 and the typical energy resolution of about 20% (FWHM) at an applied voltage between the resistive electrodes of 620 V, using a collimated 8 keV X-rays from a generator in a gas mixture of 70% Ar and 30% CO2 by volume at the atmospheric pressure. We measured the effective gain as a function of the electric field of the drift region and obtained the maximum gain at an drift field of 0.5 kV/cm.

detectors

Use of open-structure channel electron multipliers in sounding rocket experiments.

The performance of open-structure channel electron multipliers has been investigated in a laboratory simulation of the ascent pressure profile for a typical sounding rocket. The results of this test demonstrate that evacuation of the payload prior to launch is necessary for experiments where stability of response is an essential parameter.

Timothy, J. G.

Quantum efficiency of a channel electron multiplier in the far ultraviolet

Variation of the quantum efficiency of a channel electron multiplier (CEM) in the wavelength range from 1200 to 2536 A is studied. Emphasis is on measurement of CEM sensitivity longward of 1500 A. Results indicate an overall rapid decrease in quantum efficiency with increasing wavelength, with little evidence for a possible change in slope in the range from 2000 to 2500 A. The lowest efficiency measured is 4.5 + or -2.5 times 10 to the minus ninth count/photon at 2536 A. These efficiencies should ensure that unwanted radiation longward of 1500 A can be effectively removed from the bandpass of the instrument.

Paresce, F.

Cleaning and activation of beryllium-copper electron multiplier dynodes.

Description of a cleaning and activation procedure followed in preparing beryllium-copper dynodes for electron multipliers used in sounding-rocket experiments to detect auroral electrons. The initial degreasing step involved a 5-min bath in trichloroethylene in an ultrasonic cleaner. This was followed by an ultrasonic rinse in methanol and by a two-step acid pickling treatment to remove the oxides. Additional rinsing in water and methanol was followed by activation in a stainless-steel RF induction oven.

Pongratz, M. B.

Channel electron multipliers - Detection efficiencies with opaque MgF2 photocathodes at XUV wavelengths

Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.

Lapson, L. B.

Mass-dependent channel electron multiplier operation

The absolute counting efficiency and pulse height distributions of a continuous-channel electron multiplier used in the detection of hydrogen, argon and xenon ions are assessed. The assessment technique, which involves the post-acceleration of 8-eV ion beams to energies from 100 to 4000 eV, provides information on counting efficiency versus post-acceleration voltage characteristics over a wide range of ion mass. The charge pulse height distributions for H2 (+), A (+) and Xe (+) were measured by operating the experimental apparatus in a marginally gain-saturated mode. It was found that gain saturation occurs at lower channel multiplier operating voltages for light ions such as H2 (+) than for the heavier ions A (+) and Xe (+), suggesting that the technique may be used to discriminate between these two classes of ions in electrostatic analyzers.

Fields, S. A.