Engineering PapersSearch

SEARCH · Engineering Papers

Results for “ELECTRICAL EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

177 records · Page 2

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)

Supervisory genset control in range-extended electric vehicle

A controls system for a range-extended electric vehicle comprising an overall system control unit, an engine control module configured to control a range extender of the range-extended electric vehicle, power electronics configured to control a generator of the range-extended electric vehicle, and a supervisory control module coupled between the overall system control unit and the engine control module and the power electronics, the supervisory control module configured to receive information from the overall system control unit and provide commands to the engine control module and the power electronics.

Li, Ke

Power Lane County Electric Grid Handbook

In 2024, Lane Couty was selected to participate in the U.S. Department of Energy’s Energy to Community program. Through the program, National Laboratory researchers from Lawrence Berkeley National Laboratory, Pacific Northwest National Laboratory, and the National Laboratory of the Rockies provide three years of technical assistance to Lane County and their project partners: the Center for Rural Livelihoods, Springfield Utility Board, and Emerald People’s Utility District. The project, named Power Lane County, aims to improve local electric system affordability, reliability and resilience in the face of natural hazards and potentially rising loads. The Power Lane County Electric Grid Handbook establishes a foundational understanding of the energy landscape and electric grid in Lane County to inform community engagement, education, and analysis in future project phases. This document synthesizes public data and utility and stakeholder engagement, including utility interviews to give the reader a comprehensive view of the challenges facing Lane County's electric system and the opportunities to address them

Electricity

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]

Remote-Contact Catalysis for Target-Diameter Semiconducting Carbon Nanotube Arrays

Electrostatic catalysis has been an exciting development in chemical synthesis (beyond enzymes catalysis1 ) in recent years, boosting reaction rates and selectively producing certain reaction products2 . Most of the studies to date have been focused on using external electric field (EEF) to rearrange the charge distribution in small molecule reactions such as Diels-Alder addition3 , carbene reaction4 , etc. However, in order for these EEFs to be effective, a field on the order of 1 V/nm (10 MV/cm) is required, and the direction of the EEF has to be aligned with the reaction axis5 . Such a large and oriented EEF will be challenging for large-scale implementation, or materials growth with multiple reaction axis or steps. Here, we demonstrate that the energy band at the tip of an individual single-walled carbon nanotube6 (SWCNT) can be spontaneously shifted in a high-permittivity growth environment, with its other end in contact with a low-work function electrode (e.g., hafnium carbide or titanium carbide7 ). By adjusting the Fermi level at a point where there is a substantial disparity in the density of states (DOS) between semiconducting (s-) and metallic (m-) SWCNTs8 , we achieve effective electrostatic catalysis for s-SWCNT growth assisted by a weak EEF perturbation (200V/cm). This approach enables the production of high-purity (99.92%) s-SWCNT horizontal arrays with narrow diameter distribution (0.95±0.04 nm), targeting the requirement of advanced SWCNT-based electronics for future computing9-11. These findings highlight the potential of electrostatic catalysis in precise materials growth, especially for s-SWCNTs, and pave the way for the development of advanced SWCNT-based electronics12.

Wang, Jiangtao [Department of Electrical Engineeri

Mechanical, Electrochemical & Thermal Modeling of Electric Vehicle Batteries for Crash Simulation (CRADA CRD-19-00811 Final Report)

Under the proposed effort in partnership with Hyundai Motor Company (HMC), the National Laboratory of the Rockies (NLR) will cooperate with HMC to develop mathematical models for battery cells and modules for simulating abuse response in batteries subject to the type of mechanical crushing that can occur in a full motor vehicle crash.

33 ADVANCED PROPULSION SYSTEMS

A Unified Scaling Framework for Comparative Analysis of Major Electrical Machine Topologies

This paper presents a unified framework for comparing major electrical machine topologies under identical output and thermal constraints, with emphasis on supply-chain-aware selection among rare-earth-intensive, reduced-rare-earth, and rare-earth-free solutions. Using power factor and air-gap flux density as the principal descriptors, the framework links topology choice to relative size, copper demand, magnet dependence, cost sensitivity, and inertia. To support robust early-stage screening, the deterministic scaling model is combined with uncertainty representation, Monte Carlo scenario propagation, and hesitationaware ranking. The results show that rare-earth-rich machines remain compact and dense, whereas reduced-rare-earth and rare-earth-free alternatives become more attractive under specific material-risk and cost scenarios.

Kumar, Praveen [ORNL] (ORCID:0000000291877857)

Integrated Magnetics for Multiport Inductive and Conductive Power Transfer Architecture for Electric Vehicles

This paper proposes a shared magnetic arrangement for an electric-vehicle charger that supports both conductive and inductive charging while preserving independent power control at the two ports. In the proposed implementation, the high-frequency transformer used for the conductive path and the resonant inductor required by the inductive path are realized in an integrated form. By combining the magnetic structure and primary-side converter hardware, the charger can deliver improved hardware utilization and higher power density without a corresponding increase in cost or implementation complexity. The paper describes the magnetic realization and presents finite-element and circuit-level simulation results to confirm minimal interaction between the two charging paths. The study demonstrates that the proposed charger is a viable option for flexible, high-power EV charging systems.

Mukherjee, Subho [ORNL] (ORCID:0009000672297925)

Electric spiking activity in epithelial cells

Epithelial cells (human keratinocyte cells and the canine MDCK cell line), traditionally viewed as electrically non-self-excitable and involved primarily in physiological functions such as barrier presentation, absorption, secretion, and protection, are shown here to exhibit traveling extracellular electric charge when they recover from spatially focused, laser-induced wounding of confluent monolayers cultured on a multielectrode array chip. Voltage spikes measured on these electrodes display depolarization, repolarization, and hyperpolarization phases with amplitudes similar to the action potentials of neurons but with the markedly slower duration of 1 to 2 s. Some propagate distances up to hundreds of μm from the wound with a mean speed of around 10 mm s −1 . Generation and transmission of bioelectric signals are significantly influenced by the perturbation of mechanosensitive cationic ion channels. These direct measurements confirm bioelectric signaling that previous work has hypothesized to regulate epithelial cell development and may have relevance to the frequency parameter selection of bioelectric devices.

Science & Technology - Other Topics

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Toyota Highlander FCHV (CRADA CRD-12-00469 Final Report)

This project relates to the loan of four Toyota Mirai FCEV-adv vehicles to NLR to provide a load (vehicles to fill with hydrogen) to our fueling station research facility to study hydrogen fueling infrastructure performance using 700 bar precooled hydrogen at ESIF’s Hydrogen Infrastructure Testing and Research Facility (HITRF) facility.

33 ADVANCED PROPULSION SYSTEMS

Electric‐Field‐Driven Reversal of Ferromagnetism in (110)‐Oriented, Single Phase, Multiferroic Co‐Substituted BiFeO 3 Thin Films

Abstract While multiferroic materials are attractive systems for the promise of ultra‐low‐power‐consumption computational technologies, electric‐field‐induced magnetization reversal is a key challenge for realizing devices at scale. Though significant research efforts have been working toward the realization of a material which couples ferroelectricity and ferromagnetism, there are few, even composite, systems which are practical for device scale applications at room temperature. Co‐substituted multiferroic BiFe 0.9 Co 0.1 O 3 is a promising candidate system, due to coupled ferroelectricity and weak ferromagnetism at room temperature. Here, it is theoretically indicated that the ferroic orders in this material are statically coupled, where an in‐plane 109° ferroelectric switching event can result in the reversal of this out‐of‐plane component of magnetization, and the electric field‐induced magnetization reversal is experimentally observed. Such an in‐plane poling configuration is particularly desirable for device applications.

Chemistry

Electricity Rate Designs for Large Loads: Evolving Practices and Opportunities 2026 Update

Electricity demand from large-load customers such as data centers is projected to grow significantly in the near term. While these large loads play an important role in advancing technology innovation and economic growth in the United States, meeting their energy needs requires utilities and regulators to consider important operational and financial risks, such as insufficient energy supply or underutilized investments, that can impact all customers. This paper builds on similar research published in January 2025, providing an overview of how utilities and regulators are managing these risks through different tariffs, including rate structures and electric service agreements. Regulators, utilities, customers, and other stakeholders can use this paper as a foundation when discussing issues and sharing perspectives on developing or reviewing large-load tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION

Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering

An Overview of Electric Vehicle Load Modeling Strategies for Grid Integration Studies

The adoption of electric vehicles (EVs) has emerged as a solution to reduce greenhouse gas emissions in the transportation sector, which has motivated the implementation of public policies to promote their use in several countries. However, the high adoption of EVs poses challenges for the electricity sector, as it would imply an increase in energy demand and possible impacts on the power quality (PQ) of the power grid. Therefore, it is important to conduct EV integration studies in the power grid to determine the amount that can be incorporated without causing problems and identify the areas of the power sector that will require reinforcements. Accurate EV load patterns are required for this type of study that, through mathematical modeling, reflect both the dynamic behavior and the factors that influence the decision to recharge EVs. This article aims to present an overview of EVs, examine the different factors considered in the literature for modeling EV load patterns, and review modeling methods. EV load modeling methods are classified into deterministic, statistical, and machine learning. The article shows that each modeling method has its advantages, disadvantages, and data requirements, ranging from simple load modeling to more accurate models requiring large datasets.

Computer Science

Modeling the Potential Impact of Storage on the US Power Sector in a Multisector Dynamic Context

The electric power sector is expected to grow in size, importance, and complexity around the world as economies expand and electric supply technologies and demand patterns evolve in significant ways. At the same time the electric power sector may see substantial increases in VRE generating technologies which can add variability and uncertainty to the diurnal and seasonal profile of electric supply. With these forces in play, the emergence of modular, flexible electricity storage technologies may have profound impacts on the operation of electric power systems. Here we reduce a storage modeling gap in MSD models by incorporating grid-based electricity storage into the electric sector dynamics of the Global Change Analysis Model-USA (GCAM-USA) with improved power sector representation. We find a potentially significant role for storage technologies in the future of the U.S. power system, with storage capacity ranging from 7.7 to 14.7 GW in 2050 and 13.9 to 31.6 GW in 2100 across several techno-economic scenarios. We also find that storage can help to smooth variability in residual load arising from evolving electricity demands and the introduction of high shares of VRE to the electric grid. This reduces reliance on high-cost peaking generators, improves system-wide capacity factors, and limits curtailment of VRE.

Patel, Pralit L.