Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Coefficients for Estimating Prenatal Dose in Pregnant Workers from Acute Intakes

Inhalation and ingestion dose coefficients for the embryo and fetus from intakes of radionuclides by the mother are provided in the International Commission on Radiological Protection (ICRP) Publication 88 for intake of each of 74 radionuclides. To address the many other possible radionuclides to which workers may be exposed, effective dose coefficients were developed for the embryo/fetus for all additional radionuclides addressed in ICRP Publication 107 with half-life of 10 min or more. The general approach was to use the estimated dose to the mother’s uterus during pregnancy as a scalable proxy for the dose to the embryo/fetus. The set of scaling factors used in the study was derived from analyses of the relationships of the dose to the mother’s uterus and the effective dose to the embryo/fetus for the ~400 cases (considering two intake modes and multiple forms of many of the radionuclides) addressed in Publication 88.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Association of Radiation Exposure with Stable Chromosome Aberrations in Atomic Bomb Survivors Based on DS02R1 Dosimetry and FISH Methods

The frequency of stable chromosome aberrations (sCA) in lymphocytes is a recognized radiation biological dosimeter. Its analysis can provide insights into factors that affect individual susceptibility as well as into the adequacy of radiation dose estimates used in studies of atomic bomb survivors. We analyzed the relationship between atomic bomb radiation exposure using the most recent DS02R1 dose estimates and the frequency of sCA as determined by FISH in 1,868 atomic bomb survivors. We investigated factors that may affect the background sCA rate and the shape and magnitude of the dose response. As in previous analyses of sCA in atomic bomb survivors that were based on Giemsa staining methods and used older DS86 dose estimates, the relationship between radiation dose and sCA rate was significant (P < 0.0001) with a linear-quadratic relationship at lower doses that did not persist at higher doses. As before, age at the time of the bombing and type of radiation shielding were significant dose-effect modifiers (P < 0.0001), but in contrast the difference in dose response by city was not so pronounced (P = 0.026) with a city effect not evident at doses below 1.25Gy. Background sCA rate increased with age at the time of examination (P < 0.0001), but neither sex, city, nor smoking was significantly associated with background rate. Based on FISH methods and recent dosimetry, the relationship between radiation dose and sCA frequency is largely consistent with previous findings, although the lesser importance of city as an effect modifier may reflect better dosimetry as well as more reproducible scoring of sCA. The persisting difference in sCA dose response by shielding category points to remaining problems with the accuracy or precision of radiation dose estimates in some A-bomb survivors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance Assessment for the Disposal of Low-Level Waste in the 200 West Area Burial Grounds (Annual Status Report FY 2022)

This annual review provides the projected dose estimates of radionuclide inventories disposed in the active 200 West Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-EP-0645). The estimates are compared with the performance objectives defined in U.S. Department of Energy requirements (DOE O 435.1 and its companion documents DOE M 435.1-1 and DOE-STD-5002-2017). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-0063) and waste acceptance practices continue to be sufficient to maintain compliance with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations that indicate potential impacts well below performance objectives; therefore, future compliance with DOE O 435.1 is expected. Within the active burial grounds, low-level and mixed low-level waste currently may be disposed only in two lined trenches in the 218-W-5 Burial Ground (Trenches 31 and 34) until they are either filled or a decision is made to close these trenches. Some mixed low-level waste is also disposed at the Environmental Restoration Disposal Facility in the 200 West Area (which is covered under a separate PA). During this (fiscal year 2022) reporting period (October 1, 2021, through September 30, 2022), waste was disposed to the 200 West Area LLBGs. Continued groundwater monitoring of the 200 West Area LLBGs indicates no groundwater contamination due to LLBG waste. Current assumptions about future land use at the Hanford Site are consistent with PA analysis assumptions of a postclosure facility that will not be degraded by human activity. The LLBGs are in an area identified for waste management and containment of residual contamination (DOE/EIS-0391). The current closure plan for the LLBGs (DOE/RL-2000-70) estimates that the 200 West LLBGs will be closed in the 2050 timeframe. The Disposal Authorization Statement, other technical basis documents, and the radioactive waste management basis are of continued adequacy to meet the performance objectives of DOE O 435.1. Overall, there are no substantive changes to primary PA assumptions and no changes to the PA analysis conclusion; therefore, compliance with DOE O 435.1 and the Disposal Authorization Statement is maintained. A new PA to evaluate the long-term impacts of three disposal trenches that are currently active within the 200 East and 200 West Areas (Trench 94 in the 200 East Area and Trenches 31 and 34 in the 200 West Area) was initiated in fiscal year 2019 and completed in fiscal year 2022. Corrective actions addressing 3 key issues and 31 secondary issues identified during the review process were developed and submitted to the Low-Level Waste Disposal Facility Federal Review Group Co-Chairs for review and approval. This PA provides additional technical basis for the continued adequacy of the existing Operating Disposal Authorization Statement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the Disposal of Low-Level Waste in the 200 West Area Burial Grounds (Annual Status Report FY 2021)

This annual review provides the projected dose estimates of radionuclide inventories disposed in the active 200 West Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-EP-0645). The estimates are compared with the performance objectives defined in U.S. Department of Energy requirements (DOE O 435.1 and its companion documents DOE M 435.1-1 and DOE-STD-5002-2017). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-0063). and waste acceptance practices continue to be sufficient to maintain compliance with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations that indicate potential impacts well below performance objectives; therefore, future compliance with DOE O 435.1 is expected.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Status Report (FY 2020): Performance Assessment for the Disposal of Low Level Waste in the 200 East Area Burial Grounds

This annual review provides the projected dose estimates of radionuclide inventories disposed in the 200 East Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-SD-WM-TI-730). The estimates are compared with requirements of DOE O 435.1 Chg 1 and performance objectives defined in companion documents DOE M 435.1-1 Chg 1and DOE-STD-5002-2017). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-0063) and waste acceptance practices continue to be sufficient to maintain compliance with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations that indicate potential impacts well below performance objectives; therefore, future compliance with DOE O 435.1 Chg 1 is expected. A new PA study was initiated in fiscal year (FY) 2019 for evaluation of active disposal sites within the 200 East and 200 West Areas (Trench 94 in 200 East; Trenches 31 and 34 in 200 West) due to extended time elapsing between the current annual status report and the original PA for the active disposal sites. The new PA for the active disposal sites is expected to be completed in FY 2021. Within the active burial grounds in the 200 East Area, low-level waste and mixed low-level waste will continue to be disposed of in the dedicated U.S. Navy reactor compartment trench at the 218-E-12B Burial Ground (Trench 94). During this reporting period (FY 2020, from October 1, 2019, through September 30, 2020), two reactor compartments were disposed in Trench 94. Results from sorption experiments are summarized for this reporting period to quantify the efficacy of concrete waste forms in retaining key radionuclides (e.g., technetium-99 and iodine-129). The test durations ranged from 1 to 3 months. Continued groundwater monitoring of the 200 East Area LLBGs indicates no groundwater contamination due to LLBG waste. Current assumptions about future land use at the Hanford Site are consistent with PA analysis1 assumptions of a post-closure facility that will not be degraded by human activity. The LLBGs are located in an area identified for waste management and containment of residual contamination. This area will remain after final environmental remediation and the proposed shrinkage of Hanford Site boundaries to small sections within the 200 East and 200 West Areas in the Central Plateau (DOE/EIS-0391). The current closure plan for the LLBGs (DOE/RL-2000-707) estimates that the 200 East LLBGs will be closed in the 2050 timeframe. The Disposal Authorization Statement, other technical basis documents, and the radioactive waste management basis are of continued adequacy to meet the performance objectives of DOE O 435.1 Chg 1. Overall, there are no substantive changes to primary PA assumptions nor the PA analysis conclusion; therefore, compliance with DOE O 435.1 Chg 1 and the Disposal Authorization Statement is maintained.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the Disposal of Low-Level Waste in the 200 East Area Burial Grounds (Annual Status Report FY 2022)

This annual review provides the projected dose estimates of radionuclide inventories disposed in the 200 East Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-SD-WM-TI-730). The estimates are compared with the performance objectives defined in U.S. Department of Energy requirements (DOE O 435.1 and its companion documents DOE M 435.1-1 and DOE-STD-5002-2017). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-0063) and waste acceptance practices continue to be sufficient to maintain compliance with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations that indicate potential impacts well below performance objectives; therefore, future compliance with DOE O 435.1 is expected.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the Disposal of Low Level Waste in the 200 East Area Burial Grounds (FY2019 Annual Status Report)

This annual review provides the projected dose estimates of radionuclide inventories disposed in the 200 East Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-SD-WM-TI-730) and are compared with U.S. Department of Energy requirements (DOE O 435.1 and performance objectives defined in companion documents DOE M 435.1 and DOE-STD-5002-2017). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-0063) and waste acceptance practices continue to be sufficient to maintain compliance with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations, indicating that potential impacts are well below performance objectives; therefore, future compliance with DOE O 435.1 is expected. A new PA study has been initiated in this fiscal year (FY) 2019 for evaluation of active disposal sites within the 200 West and East Areas (Trenches 31 and 34 in 200 West; Trench 94 in 200 East) because extended time has elapsed between the current annual status report and the original PA (WHC-SD-WM-TI-370) for the active disposal sites. The new PA for the active disposal sites is expected to be completed in FY 2021.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the Disposal of Low Level Waste in the 200 West Area Burial Grounds (FY2019 Annual Statius Report)

This annual review provides the projected dose estimates of radionuclide inventories disposed in the active 200 West Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-EP-0645) and are compared with performance objectives defined in U.S. Department of Energy requirements (DOE O 435.1 and its companion documents DOE M 435.1-1 and DOE-STD-5002-2017). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-0063) and waste acceptance practices continue to be sufficient to maintain compliance with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations, indicating that potential impacts are well below performance objectives; therefore, future compliance with DOE O 435.1 is expected.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EPR-based uncertainty validation of the calculated external doses for population exposed in the urals region

Tooth enamel Electron Paramagnetic Resonance (EPR) spectroscopy was used as a method for external dosimetry in the territories contaminated in the 1950s by PA ‘Mayak’ (Urals region) to validate the mean dose estimates predicted by the Techa River Dosimetry System (TRDS). The purpose of this study is to validate the uncertainties of TRDS doses. Ninety percent confidence intervals (90% confidence interval, CI) of dose estimated with both methods were compared for 220 people. All data were grouped according to the width of 90%CI, viz.: (1) 90%CI of EPR-based dose ≤ 90%CI of TRDS prediction (38 cases); (2) 90%CI of EPR-based dose > 90%CI of TRDS prediction (182 cases). About 91% of 90%CIs overlap. In group 1, 100% cases overlap. In group 2, 80% of the cases were non-contradictive (the calculated 90%CI is completely within the measured one). Interval comparison of doses predicted retrospectively and estimated based on individual measurements are non-contradictory and demonstrate a good agreement.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of FISH based G2-PCC assay for the cytogenetic assessment of high radiation dose exposures: Potential implications for rapid triage biodosimetry

The main goal of this study is to test the utility of calyculin A induced G2-PCC assay as a biodosimetry triage tool for assessing a wide range of low and acute high radiation dose exposures of photons. Towards this initiative, chromosome aberrations induced by low and high doses of x-rays were evaluated and characterized in G2-prematurely condensed chromosomes (G2-PCCs) by fluorescence in situ hybridization (FISH) using human centromere and telomere specific PNA (peptide nucleic acid) probes. A dose dependent increase in the frequency of dicentric chromosomes was observed in the G2-PCCs up to 20 Gy of x-rays. The combined yields of dicentrics and rings in the G2-PCCs showed a clear dose dependency up to 20 Gy from 0.02/cell for 0.1 Gy to 14.98/cell for 20 Gy. Centric rings were observed more frequently than acentric ring chromosomes in the G2-PCCs at all the radiation doses from 1 Gy to 20 Gy. A head-to-head comparison was also performed by FISH on the yields of chromosome aberrations induced by different doses of x-rays (0 Gy -7.5 Gy) in colcemid arrested metaphase chromosomes and calyculin A induced G2-PCCs. In general, the frequencies of dicentrics, rings and acentric fragments were slightly higher in G2-PCCs than in colcemid arrested metaphase chromosomes at all the radiation doses, but the differences were not statistically significant. To reduce the turnaround time for absorbed radiation dose estimation, attempt was made to obtain G2-PCCs by reducing the culture time to 36 hrs. The absorbed doses estimated in x-rays irradiated (0,1,2 and 4 Gy) G2-PCCs after 36 hrs of culture were grossly like that of G2-PCCs and colcemid arrested metaphase chromosomes prepared after 48 hrs of culture. Our study indicates that the shortened version of calyculin A induced G2-PCC assay coupled with the FISH staining technique can serve as an effective triage biodosimetry tool for large-scale radiological/nuclear incidents.

Science & Technology - Other Topics↗

Empirical evidence that mean soil contaminant concentration is not a conservative indicator of external exposure to wildlife

Adequate information on external exposure is often a limiting factor in ecological risk assessments because of a lack of exposure data for free-ranging animals as they interact with a heterogeneous distribution of contaminants. Instead, most wildlife exposure data are estimated from model simulations. However, empirical exposure data are rarely available to verify model results, or to test fundamental assumptions inherent in exposure assessments. We used novel, GPS-coupled radiation dosimeters on reindeer (Rangifer tarandus) to quantify their external exposure for five months in a Chernobyl fallout affected mountainous area of Norway. The exposure data were then used to test a fundamental assumption in screening-level risk assessments: Mean soil contaminant concentrations can be used to conservatively estimate chronic external exposures to representative animals. External exposure and GPS coordinates were obtained hourly and compared to model simulations of exposure based on airborne surveys of 137 Cs soil contamination. Our objectives were to determine 1) if modelled dose estimates based on mean 137 Cs soil concentrations were conservative, and 2) if modelled dose estimates could be improved by adjusting for spatial–temporal heterogeneity of contaminants using 137 Cs concentrations within reindeers’ GPS-defined home ranges and core areas. We found that external exposure modelled from mean soil contaminant concentrations underestimated exposure by 70% compared to empirical measurements from GPS-dosimeter collars worn on individual animals. Using area-weighted mean contaminant levels within the animals’ home range improved the model estimates, but still underestimated the field dosimeter data by 53%. The best estimate of external exposure was obtained when high-use areas within their home range, along with spatial heterogeneity of the contaminant, was accounted for by using area-weighted mean soil contaminant levels within GPS-derived core areas. Accounting for temporal use of core areas within animals’ home range provided a 24% improvement. Here, a comparison of our analyses to similar work performed on Chernobyl wolves found the two studies concur that risk assessors should be cautious in relying on the paradigm of using averaged soil contaminant levels to provide conservative estimates of external exposure to representative individuals. Results of modelled external exposure based on mean soil contaminant concentrations could misguide assessors and cause inappropriate management decisions.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Public Health Response and Medical Management of Internal Contamination in Past Radiological or Nuclear Incidents: A Review

Following a radiological or nuclear emergency, workers, responders and the public may be internally contaminated with radionuclides. Screening, monitoring and assessing any internal contamination and providing necessary medical treatment, especially when a large number of individuals are involved, is challenging. Experience gained and lessons learned from the management of previous incidents would help to identify gaps in knowledge and capabilities on preparedness for and response to radiation emergencies. In this paper, eight largescale and five workplace radiological and nuclear incidents are reviewed cross 14 technical areas, under the broader topics of emergency preparedness, emergency response and recovery processes. The review findings suggest that 1) new strategies, algorithms and technologies are explored for rapid screening of large populations; 2) exposure assessment and dose estimation in emergency response and dose reconstruction in recovery process are supported by complementary sources of information, including ‘citizen science’; 3) surge capacity for monitoring and dose assessment is coordinated through national and international laboratory networks; 4) evidence-based guidelines for medical management and follow-up of internal contamination are urgently needed; 5) mechanisms for international and regional access to medical countermeasures are investigated and implemented; 6) long-term health and medical follow up programs are designed and justified; and 7) capabilities and capacity developed for emergency response are sustained through adequate resource allocation, routine nonemergency use of technical skills in regular exercises, training, and continuous improvement.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improving Dose Modeling With Dynamic Modeling Tools [Slides]

Utilities aiming for higher fuel enrichment for power uprates or extended operation times before refueling must conduct a new dose analysis. Current conservative dose estimation standards may cause utilities to exceed regulatory limits for proposed increased fuel enrichment. A more accurate modeling of doses from reactor accidents can lower these conservative assumptions. Prescott et al. (2022) demonstrated that the Event Modeling Risk Assessment using Linked Diagrams (EMRALD) software tool, developed at Idaho National Laboratory (INL), can be coupled with the Modular Accident Analysis Program (MAAP5) for dynamic accident analysis in reactor plants. EMRALD forms models of potential accident scenarios, while MAAP5 simulates the accident progression and dose consequences. By integrating these software tools with utility-specific data, a more precise estimation of dose consequences from plant accidents can be achieved. Preliminary findings indicate that EMRALD provides accurate mean core damage frequencies for generalized accident scenarios. Future work includes expanding the model to account for plant-specific data and mitigation factors.

97 - MATHEMATICS AND COMPUTING↗

Assessment of doses in contaminated urban areas: modelling exercise based on Fukushima data

State-of-the-art dose assessment models were applied to estimate doses to the population in urban areas contaminated by the Fukushima Daiichi Nuclear Power Plant accident. Assessment results were compared among five models, and comparisons of model predictions with actual measurements were also made. Assessments were performed using both probabilistic and deterministic approaches. Predicted dose distributions for indoor and outdoor workers from a probabilistic approach were in good agreement with the actual measurements. In addition, when the models were applied to assess the doses to the representative person, based on a concept recommended by the International Commission on Radiological Protection and in the International Atomic Energy Agency Safety Standards, it was evident that doses to the representative person obtained with a deterministic approach were always higher than those obtained with a probabilistic approach using the same model.

dose assessment↗

Simulated Energy Response in a Multiplicity Detector

Neutron multiplicity analysis is used for many applications, including nonproliferation and criticality safety. Multiplicity detectors have advantages over total neutron counting as they provide the ability to assess both multiplication and mass in fissionable material. In addition, multiplicity detectors can generate real-time information, e.g., dose estimation. The ability to evaluate the detector efficiency in each application is of primary importance in producing meaningful analyses. Multiplicity detectors usually house 3 He tubes within a polyethylene moderator. If the tubes are located behind different thickness of polyethylene, they will have different energy responses. This paper assesses 3 He tube efficiency as a function of neutron energy for a specific multiplicity detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimating dermal contact soil exposure for amphibians

Abstract Chemical exposure estimation through the dermal route is an underemphasized area of ecological risk assessment for terrestrial animals. Currently, there are efforts to create exposure models to estimate doses from this pathway for use in ecological risk assessment. One significant limitation has been insufficient published data to characterize exposure and to support the selection and parameterization of appropriate models, particularly for amphibians in terrestrial habitats. Recent publications measuring pesticide doses to terrestrial‐phase amphibians have begun to rectify this situation. We collated and summarized available measurements of terrestrial amphibian dermal exposure to pesticides from 11 studies in which researchers measured tissue concentrations associated with known pesticide experimental application rates. This data set included tissue concentrations in 11 amphibian species and 14 different pesticides. We then compared the results of two screening exposure models that differed based on surface area scaling approaches as a function of body weight (one based on birds as surrogates for amphibians and another amphibian‐specific) to the measured tissue residue concentrations. We define a false‐negative rate for each screening model as the proportion of amphibians for which the predicted concentration is less than the observed concentration (i.e., underestimate), contrary to the intent of screening models, which are intended to have a bias for higher exposure concentrations. The screening model that uses birds as surrogates did not have any instances where estimated expected avian doses were less than measured amphibian body burdens. When using the amphibian‐specific exposure model that corrected for differences between avian and amphibian surface area, measured concentrations were greater than model estimates for 11.3% of the 1158 comparisons. The database of measured pesticide concentrations in terrestrial amphibians is provided for use in calculating bioconcentration factors and for future amphibian dermal exposure model development. Integr Environ Assess Manag 2023;19:9–16. © 2022 SETAC. This article has been contributed to by U.S. Government employees and their work is in the public domain in the USA.

Environmental Sciences & Ecology↗