Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct dark matter search”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The CMSSM survives Planck , the LHC, LUX-ZEPLIN, Fermi -LAT, H.E.S.S. and IceCube

We revisit the viability of the CMSSM, searching for regions of parameter space that yield a neutralino dark matter density compatible with Planck measurements, as well as LHC constraints including sparticle searches and the mass of the Higgs boson, recent direct limits on spin-independent and -dependent dark matter scattering from the LUX-ZEPLIN (LZ) experiment, the indirect constraints from Fermi-LAT and H.E.S.S. on dark matter annihilations to photons in dwarf spheroidal galaxies and the Galactic Centre, and the IceCube limits on muons from annihilations to neutrinos in the Sun. For representative values of tan β and A 0 we map in detail the Planck-compatible strips in CMSSM parameter planes, which exhibit multiple distinctive features for large tan β, A 0 = 0 and μ > 0, and identify portions of the strips that survive all the phenomenological constraints. We find that the most powerful constraint is that from m h , followed by the LZ limit on spin-independent scattering, whereas sparticle searches at the LHC and indirect dark matter searches are less restrictive. Most of the surviving CMSSM parameter space features a Higgsino-like dark matter particle with a mass ~ 1000–1100 GeV, which could best be probed with future direct searches for dark matter scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibrating the scintillation and ionization responses of xenon recoils for high-energy dark matter searches

We report liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models, but few xenon recoil calibrations above 100 keV are currently available. In this work, we measured the scintillation and ionization yields of xenon recoils up to 426 keV. The experiment uses 14.1 MeV neutrons to scatter off xenon in a compact liquid xenon time projection chamber and produce quasimonoenergetic xenon recoils between 39 and 426 keV. We report the xenon recoil responses and their electric field dependence for recoil energies up to 306 keV; due to the low event statistics and the relatively mild field dependence, the yield values at higher energies are reported as the average of xenon responses for electric fields between 0.2 and 2.0 kV/cm. This result will enable xenon-based dark matter experiments to significantly increase their high-energy dark matter sensitivities by including energy regions that were previously inaccessible due to lack of calibrations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New directions in the search for dark matter

The identification of the nature of dark matter is one of the most important problems confronting particle physics. Current observational constraints permit the mass of the dark matter to range from 10^{-22} 10 − 22 eV - 10^{48} 10 48 GeV. Given the weak nature of these bounds and the ease with which dark matter models can be constructed, it is clear that the problem can only be solved experimentally. In these lectures, I discuss methods to experimentally probe a wide range of dark matter candidates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Future Circular Collider: a Summary for the US 2021 Snowmass Process

In this white paper for the 2021 Snowmass process, we give a description of the proposed Future Circular Collider (FCC) project and its physics program. The paper summarizes and updates the discussion submitted to the European Strategy on Particle Physics. After construction of an approximately 90 km tunnel, an electron-positron collider based on established technologies allows world-record instantaneous luminosities at center-of-mass energies from the Z resonance up to tt thresholds, enabling a rich set of fundamental measurements including Higgs couplings determinations at the sub percent level, precision tests of the weak and strong forces, and searches for new particles, including dark matter, both directly and via virtual corrections or mixing. Among other possibilities, the FCC-ee will be able to (i) indirectly discover new particles coupling to the Higgs and/or electroweak bosons up to scales around 7 and 50 TeV, respectively; (ii) perform competitive SUSY tests at the loop level in regions not accessible at the LHC; (iii) study heavy-flavor and tau physics in ultra-rare decays beyond the LHC reach, and (iv) achieve the best potential in direct collider searches for dark matter, sterile neutrinos, and axion-like particles with masses up to around 90 GeV. The tunnel can then be reused for a proton-proton collider, establishing record center-of-mass collision energy, allowing unprecedented reach for direct searches for new particles up to the around 50 TeV scale, and a diverse program of measurements of the Standard Model and Higgs boson, including a precision measurement of the Higgs self-coupling, and conclusively testing weakly-interacting massive particle scenarios of thermal relic dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The design, implementation, and performance of the LZ calibration systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light dark matter search with nitrogen-vacancy centers in diamonds

We propose an approach to directly search for light dark matter, such as the axion or the dark photon, by using magnetometry with nitrogen-vacancy centers in diamonds. If the dark matter couples to the electron spin, it affects the evolution of the Bloch vectors consisting of the spin triplet states, which may be detected through several magnetometry techniques. We give several concrete examples with the use of dc and ac magnetometry and estimate the sensitivity on dark matter couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Distinctive signals of frustrated dark matter

We study a renormalizable model of Dirac fermion dark matter (DM) that communicates with the Standard Model (SM) through a pair of mediators — one scalar, one fermion — in the representation (6, 1, $\frac{4}{3}$) of the SM gauge group SU(3) c x SU(2) L x U(1) Y . While such assignments preclude direct coupling of the dark matter to the Standard Model at tree level, we examine the many effective operators generated at one-loop order when the mediators are heavy, and find that they are often phenomenologically relevant. We reinterpret dijet and pair-produced resonance and jets + E$^{miss}_{T}$ searches at the Large Hadron Collider (LHC) in order to constrain the mediator sector, and we examine an array of DM constraints ranging from the observed relic density Ω χ h$^{2}_{Planck}$ to indirect and direct searches for dark matter. Tree-level annihilation, available for DM masses starting at the TeV scale, is required in order to produce Ω χ h$^{2}_{Planck}$ through freeze-out, but loops — led by the dimension-five DM magnetic dipole moment — are nonetheless able to produce signals large enough to be constrained, particularly by the XENON1T experiment. In some benchmarks, we find a fair amount of parameter space left open by experiment and compatible with freeze-out. In other scenarios, however, the open space is quite small, suggesting a need for further model-building and/or non-standard cosmologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the Speed-up of Wave-like Dark Matter Searches with Entangled Qubits

Qubit-based sensing platforms offer promising new directions for wave-like dark matter searches. Recent proposals demonstrate that entangled qubits can achieve quadratic scaling of the signal in the number of qubits. In this work we expand on these proposals to analyze the bandwidth and scan rate performance of entangled qubit protocols across different error regimes. We find that the phase-based readout of entangled protocols preserves the search bandwidth independent of qubit number, in contrast to power-based detection schemes, thereby achieving a genuine scan-rate advantage. We derive coherence time and error rate requirements for qubit systems to realize this advantage. Applying our analysis to dark photon searches, we find that entangled states of approximately 100 qubits can become competitive with benchmark photon-counting cavity experiments for masses $\gtrsim 30{-}40~μ{\rm eV}$, provided sufficiently low error rates are achieved. The advantage increases at higher masses where cavity volume scaling becomes less favorable.

Bodas, Arushi [Fermilab; Chicago U.] (ORCID:000000↗

Anatomy of the electroweak phase transition for dark sector induced baryogenesis

We investigate the electroweak phase transition patterns for a recently proposed baryogenesis model with CP violation originated in the dark sector. The model includes a complex scalar singlet-Higgs boson portal, a U(1) l gauge lepton symmetry with a Z ' gauge boson portal and a fermionic dark matter particle. We find a novel thermal history of the scalar sector, featuring a Z 2 breaking singlet vacuum in the early Universe driven by a dark Yukawa coupling, that induces a one-step strongly first order electroweak phase transition. We explore the parameter space that generates the observed matter-antimatter asymmetry and dark matter relic abundance, while being consistent with constraints from electric dipole moment, collider searches, and dark matter direct detection bounds. The complex singlet can be produced via the Higgs portal and decays into Standard Model particles after traveling a certain distance. We explore the reach for long-lived singlet scalars at the 13 TeV Large Hadron Collider with \( \mathcal{L} \) = 139 fb - 1 and show its impact on the parameter space of the model. Setting aside currently unresolved theoretical uncertainties, we estimate the gravitational wave signatures detectable at future observatories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Skipper-CCDs: Current applications and future

This work briefly discusses the potential applications of the Skipper-CCD technology in astronomy and reviews its current use in dark matter and neutrino experiments. An overview of the ongoing efforts to build multi-kilogram experiments with these sensors is given, in the context of the Oscura experiment. First results from the characterization of Oscura sensors from the first 200 mm wafer-fabrication run with a new vendor are presented. The overall yield of the electron counting capability of these sensors is 71%. In conclusion, a noise of 0.087 e - RMS, with 1225 samples/pix, and a dark current of (0.031±0.013) e - /pix/day at 140 K were measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DarkSide-20k TPC and underground argon cryogenic system

DarkSide-20k (DS-20k) will exploit the physical and chemical properties of liquid argon (LAr) housed within a large dual-phase time project chamber (TPC) in its direct search for dark matter. The TPC will utilize a compact, integrated design with many novel features to enable the 20t fiducial volume of underground argon. Underground Argon (UAr) is sourced from underground CO _2 2 wells and depleted in the radioactive isotope ^{39} 39 Ar, greatly enhancing the experimental sensitivity to dark matter interactions. Sourcing and transporting the \mathcal{O} 𝒪 (100t) of UAr for (DS-20k) is costly, and a dedicated single-closed-loop cryogenic system has been designed, constructed, and tested to handle the valuable UAr. We present an overview of the (DS-20k) TPC design and the first results from the UAr cryogenic system.

Thorpe, Thomas N.↗

Superconducting Detectors Come of Age, or Ready to Leave the Lab

Cryogenically cooled superconducting detectors have become essential tools for a wide range of measurement applications, ranging from quantum limited heterodyne detection in the millimeter range to direct searches for dark matter with superconducting phonon detectors operating at 20 mK. Superconducting detectors have several fundamental and practical advantages which have resulted in their rapid adoption by experimenters. Their excellent performance arises in part from reductions in noise resulting from their low operating temperatures, but unique superconducting properties provide a wide range of mechanisms for detection. For example, the steep dependence of resistance with temperature on the superconductor normal transition provides a sensitive thermometer for calorimetric and bolometric applications. Parametric changes in the properties of superconducting resonators provide a mechanism for high sensitivity detection of submillil.neter photons. From a practical point of view, the use of superconducting detectors has grown rapidly because many of these devices couple well to SQUID amplifiers, which are easily integrated with the detectors. These SQUID-based amplifiers and multiplexers have matured with the detectors; they are convenient to use, and have excellent noise performance. The first generation of fully integrated large-scale superconducting detection systems is now being deployed. Improved understanding of the operation of these detectors, combined with rapidly improving fabrication techniques, is quickly expanding the capability of these detectors. I will review the development and application of superconductor-based detectors, the ultimate limits to their performance, and consider prospects for their future applications. Continued advances promise to enable important new measurements in physics, and with appropriate advances in cryogenic infrastn~cturem, ay result in the use of these detectors in everyday monitoring applications.

Moseley, Samuel H.↗

Detectors for Tomorrow's Instruments

Cryogenically cooled superconducting detectors have become essential tools for a wide range of measurement applications, ranging from quantum limited heterodyne detection in the millimeter range to direct searches for dark matter with superconducting phonon detectors operating at 20 mK. Superconducting detectors have several fundamental and practical advantages which have resulted in their rapid adoption by experimenters. Their excellent performance arises in part from reductions in noise resulting from their low operating temperatures, but unique superconducting properties provide a wide range of mechanisms for detection. For example, the steep dependence of resistance with temperature on the superconductor/normal transition provides a sensitive thermometer for calorimetric and bolometric applications. Parametric changes in the properties of superconducting resonators provides a mechanism for high sensitivity detection of submillimeter photons. From a practical point of view, the use of superconducting detectors has grown rapidly because many of these devices couple well to SQUID amplifiers, which are easily integrated with the detectors. These SQUID-based amplifiers and multiplexers have matured with the detectors; they are convenient to use, and have excellent noise performance. The first generation of fully integrated large scale superconducting detection systems are now being deployed. I will discuss the prospects for a new generation of instruments designed to take full advantage of the revolution in detector technology.

Moseley, Harvey↗

Snowmass2021 Cosmic Frontier: The landscape of low-threshold dark matter direct detection in the next decade

The search for particle-like dark matter with meV-to-GeV masses has developed rapidly in the past few years. We summarize the science case for these searches, the recent progress, and the exciting upcoming opportunities. Funding for Research and Development and a portfolio of small dark matter projects will allow the community to capitalize on the substantial recent advances in theory and experiment and probe vast regions of unexplored dark-matter parameter space in the coming decade.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Information-theoretic astrophysical uncertainties in the effective theory of dark matter direct detection

The impact of astrophysical uncertainties in direct detection searches can vary significantly across particle dark matter models and detector targets, due to the different velocity and momentum dependencies of the scattering cross section. We address these uncertainties for all operators of the nonrelativistic effective field theory of dark-matter/nucleon interactions, making use of the Kullback-Leibler (KL) information divergence to measure the deviation of the true dark matter velocity distribution from the Maxwell-Boltzmann form. This approach quantifies how astrophysical uncertainties affect each operator in the effective theory, without assuming any specific functional form for the velocity distribution. While for some operators the uncertainties are smaller than 1 order of magnitude for entropically motivated deviations from the Maxwell-Boltzmann form, for other operators, these uncertainties can be as large as three orders of magnitude near threshold. Furthermore, we identify the dependence of the scattering rate for various operators of the effective theory with different velocity-weighted moments of the velocity distribution, functionally analogous to the mean, variance, or skewness. This provides new analytic insight into which features of the velocity distribution are most relevant to detect a given particle dark matter model. Our technique is general and could be applied to a broader class of physics problems where a physical observable depends on the statistical moments of an uncertain theoretical distribution.

Herrera, Gonzalo [MIT, MKI; Harvard U.; Virginia T↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗