Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

Characterization of fluorite-structured ferroelectrics using transmission electron microscopy: Techniques, challenges, and recent advances

Fluorite-structured ferroelectrics, such as hafnium oxide and its alloyed variants, are key candidates for next-generation memory devices. Yet, fundamental questions about switching mechanisms, domain dynamics, and phase evolution remain open. Transmission electron microscopy (TEM) provides unique capabilities to address these challenges by simultaneously resolving the positions of anions and cations, chemical variations, and structural transformations. Recent advances—including in situ heating, electron beam-induced switching, electron energy loss spectroscopy, and differential phase contrast imaging—have revealed critical insights into phase transitions, potential switching pathways, and oxygen vacancy behavior. However, experimental barriers such as TEM sample-preparation-induced artifacts, high coercive fields, and imaging constraints persist, especially for polycrystalline films. By offering a focused overview of current TEM developments in fluorite ferroelectrics, this work outlines how TEM contributes to understanding key phenomena and proposes a roadmap for future studies.

36 MATERIALS SCIENCE↗

Simultaneous hard x-ray Talbot phase and dark-field imaging in laser experiments at XFEL facilities

X-ray Free Electron Laser (XFEL) facilities offer unprecedented opportunities to advance instrumentation for studying matter under extreme conditions. In this study, we harnessed the enhanced x-ray capabilities of XFELs to demonstrate dark field imaging in laser-driven experiments at XFEL facilities. Utilizing a Talbot x-ray interferometer, we simultaneously captured transmission, dark-field, and differential phase contrast radiographs of laser-driven metallic foils. Our work showcases the feasibility of single-shot grating-based Talbot x-ray dark-field imaging in pump-probe experiments at XFEL facilities, opening doors to a wide range of hard x-ray imaging applications in material science and high-energy density physics.

Bouffetier, V. [Helmholtz-Zentrum Dresden-Rossendo↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

High‐speed 4‐dimensional scanning transmission electron microscopy using compressive sensing techniques

Abstract Here we show that compressive sensing allows 4‐dimensional (4‐D) STEM data to be obtained and accurately reconstructed with both high‐speed and reduced electron fluence. The methodology needed to achieve these results compared to conventional 4‐D approaches requires only that a random subset of probe locations is acquired from the typical regular scanning grid, which immediately generates both higher speed and the lower fluence experimentally. We also consider downsampling of the detector, showing that oversampling is inherent within convergent beam electron diffraction (CBED) patterns and that detector downsampling does not reduce precision but allows faster experimental data acquisition. Analysis of an experimental atomic resolution yttrium silicide dataset shows that it is possible to recover over 25 dB peak signal‐to‐noise ratio in the recovered phase using 0.3% of the total data. Lay abstract : Four‐dimensional scanning transmission electron microscopy (4‐D STEM) is a powerful technique for characterizing complex nanoscale structures. In this method, a convergent beam electron diffraction pattern (CBED) is acquired at each probe location during the scan of the sample. This means that a 2‐dimensional signal is acquired at each 2‐D probe location, equating to a 4‐D dataset. Despite the recent development of fast direct electron detectors, some capable of 100kHz frame rates, the limiting factor for 4‐D STEM is acquisition times in the majority of cases, where cameras will typically operate on the order of 2kHz. This means that a raster scan containing 256^2 probe locations can take on the order of 30s, approximately 100‐1000 times longer than a conventional STEM imaging technique using monolithic radial detectors. As a result, 4‐D STEM acquisitions can be subject to adverse effects such as drift, beam damage, and sample contamination. Recent advances in computational imaging techniques for STEM have allowed for faster acquisition speeds by way of acquiring only a random subset of probe locations from the field of view. By doing this, the acquisition time is significantly reduced, in some cases by a factor of 10‐100 times. The acquired data is then processed to fill‐in or inpaint the missing data, taking advantage of the inherently low‐complex signals which can be linearly combined to recover the information. In this work, similar methods are demonstrated for the acquisition of 4‐D STEM data, where only a random subset of CBED patterns are acquired over the raster scan. We simulate the compressive sensing acquisition method for 4‐D STEM and present our findings for a variety of analysis techniques such as ptychography and differential phase contrast. Our results show that acquisition times can be significantly reduced on the order of 100‐300 times, therefore improving existing frame rates, as well as further reducing the electron fluence beyond just using a faster camera.

Robinson, Alex W.↗

Different CT slice thickness and contrast‐enhancement phase in radiomics models on the differential performance of lung adenocarcinoma

Abstract Background To investigate the effects of computed tomography (CT) reconstruction slice thickness and contrast‐enhancement phase on the differential diagnosis performance of radiomic signature in lung adenocarcinoma. Methods A total of 187 patients who had been pathologically confirmed with lung adenocarcinoma and nonadenocarcinoma were divided into a training cohort ( n = 149) and validation cohort ( n = 38). All the patients underwent contrast‐enhanced CT and the images were reconstructed with different slice thickness. The radiomic features were extracted from different slice thickness and scan phase. The logistic regression (LR) algorithm was used to build a machine learning model for each group. The area under the curve (AUC) obtained from the receiver operating characteristic (ROC) curve and DeLong test was used to evaluate its discriminating performance. Results Finally, 34 image features and five semantic features were selected to establish a radiomics model. Based on the three contrast‐enhanced CT phases and four reconstruction slice thickness, 12 groups of radiomics models showed good discrimination ability with the AUCs range from 0.9287 to 0.9631, sensitivity range from 0.8349 to 0.9083, specificity range from 0.825 to 0.925 in the training group. Similar results were observed in the validation group. However, there was no statistical significance between the different CT scan phase groups and different slice thickness ( p > 0.05). Conclusions The radiomic analysis of contrast‐enhanced CT can be used for the differential diagnosis of lung adenocarcinoma. Moreover, different slice thickness and contrast‐enhanced scan phase did not affect the discriminating ability in the radiomics models.

Wang, Yang↗

The incommensurate modulation of tetragonal tungsten bronze quantified by high resolution 4D STEM

Many members of the tetragonal tungsten bronze (TTB) family of oxides display an incommensurate periodic lattice distortion, the nature of which has been the subject of some controversy. Here we present a study of this structural modulation in the relaxor ferroelectric Ba 5 SmSn 3 Nb 7 O 30 (BSSN) by quantitative scanning transmission electron microscopy (STEM). Additionally, we characterize the modulation in BSSN by employing a fast, pixelated direct electron detector to perform high resolution phase contrast STEM imaging of the crystalline lattice. By quantitatively analyzing the images, we visualize the atomic structural correlations present in the material on both the cation and anion sublattices. This analysis reveals the incommensurate structure to have an octahedral tilting pattern and cooperative A2 site cation displacements, analogous to an Ama2 commensurate cell. Finally, we show that the modulation is composed of a structural motif with a period of 3 x $d_{1\bar{1}0}$ and modified by discommensurations, likely arise from frustrated octahedral tilting in the odd-valued periodicity.

Differential phase contrast↗

Robust Atomic-Resolution Imaging of Lithium in Battery Materials by Center-of-Mass Scanning Transmission Electron Microscopy

The performance of energy storage materials is often governed by their structure at the atomic scale. Conventional electron microscopy can provide detailed information about materials at these length scales, but direct imaging of light elements such as lithium presents a challenge. While several recent techniques allow lithium columns to be distinguished, these typically either involve complex contrast mechanisms that make image interpretation difficult or require significant expertise to perform. In this work, we demonstrate how center-of-mass scanning transmission electron microscopy (CoM-STEM) provides an enhanced ability for simultaneous imaging of lithium and heavier element columns in lithium ion conductors. Through a combination of experiments and multislice electron scattering calculations, we show that CoM-STEM is straightforward to perform and produces directly interpretable contrast for thin samples, while being more robust to variations in experimental parameters than previously demonstrated techniques. As a result, CoM-STEM is positioned to become a reliable and facile method for directly probing all elements within energy storage materials at the atomic scale.

25 ENERGY STORAGE↗

Multimodal X-ray nano-spectromicroscopy analysis of chemically heterogeneous systems

Abstract Understanding the nanoscale chemical speciation of heterogeneous systems in their native environment is critical for several disciplines such as life and environmental sciences, biogeochemistry, and materials science. Synchrotron-based X-ray spectromicroscopy tools are widely used to understand the chemistry and morphology of complex material systems owing to their high penetration depth and sensitivity. The multidimensional (4D+) structure of spectromicroscopy data poses visualization and data-reduction challenges. This paper reports the strategies for the visualization and analysis of spectromicroscopy data. We created a new graphical user interface and data analysis platform named XMIDAS (X-ray multimodal image data analysis software) to visualize spectromicroscopy data from both image and spectrum representations. The interactive data analysis toolkit combined conventional analysis methods with well-established machine learning classification algorithms (e.g. nonnegative matrix factorization) for data reduction. The data visualization and analysis methodologies were then defined and optimized using a model particle aggregate with known chemical composition. Nanoprobe-based X-ray fluorescence (nano-XRF) and X-ray absorption near edge structure (nano-XANES) spectromicroscopy techniques were used to probe elemental and chemical state information of the aggregate sample. We illustrated the complete chemical speciation methodology of the model particle by using XMIDAS. Next, we demonstrated the application of this approach in detecting and characterizing nanoparticles associated with alveolar macrophages. Our multimodal approach combining nano-XRF, nano-XANES, and differential phase-contrast imaging efficiently visualizes the chemistry of localized nanostructure with the morphology. We believe that the optimized data-reduction strategies and tool development will facilitate the analysis of complex biological and environmental samples using X-ray spectromicroscopy techniques.

36 MATERIALS SCIENCE↗

Atomically sharp domain walls in an antiferromagnet

The interest in understanding scaling limits of magnetic textures such as domain walls spans the entire field of magnetism from its physical fundamentals to applications in information technologies. Here, we explore antiferromagnetic CuMnAs in which imaging by x-ray photoemission reveals the presence of magnetic textures down to nanoscale, reaching the detection limit of this established microscopy in antiferromagnets. We achieve atomic resolution by using differential phase-contrast imaging within aberration-corrected scanning transmission electron microscopy. We identify abrupt domain walls in the antiferromagnetic film corresponding to the Néel order reversal between two neighboring atomic planes. Our work stimulates research of magnetic textures at the ultimate atomic scale and sheds light on electrical and ultrafast optical antiferromagnetic devices with magnetic field–insensitive neuromorphic functionalities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron Grating Interferometry at the High Flux Isotope Reactor

Neutron imaging is a non-destructive probe that can spatially resolve bulk materials’ internal features/structures. Neutron imaging spatial resolution is driven by detector technology, i.e., pixel size, and is currently on the order of 10–20 µm. This limitation can be alleviated by the use of neutron grating interferometry – an advanced neutron imaging technique – that enables simultaneous access to three contrast mechanisms: attenuation, differential phase, and small-angle neutron scattering. Recently, a Talbot-Lau neutron grating interferometry has been implemented at the Multimodal Advanced Radiography Station at the High Flux Isotope Reactor. In this work, the design, setup and performance of the grating apparatus are presented.

Zhang, Yuxuan [ORNL] (ORCID:0000000200831408)↗

Element differentiation with a Hartmann- based X-ray phase imaging system

Significant efforts are currently ongoing in X-ray imaging to provide multimodal imaging systems, targeting better sensitivity and specificity for both biomedical or non-destructive testing applications. Knowing the elemental composition of specific structures, such as breast microcalcifications in mammography, would help to differentiate malign and benign tumours. Standard X-ray Phase Contrast Imaging techniques provide only qualitative information on elements with similar absorption properties. However, their chemical composition can be determined from the measurement of the phase as it is directly related to the optical index of elemental materials. We will show new experimental results obtained with an X-ray phase imaging system based on a Hartmann mask. Early data treatment succeeded in retrieving both the real and imaginary parts of the refractive index. The system demonstrates the capability to discriminate materials based on elemental composition.

36 MATERIALS SCIENCE↗

Single-shot x-ray phase-contrast and dark-field imaging based on coded binary phase mask

We introduce a coded-mask-based multi-contrast imaging method for high-resolution phase-contrast and dark-field imaging. The method uses a binary phase mask designed to provide an ultra-high-contrast pattern and reference-free single-shot measurement and an algorithm based on maximum-likelihood optimization and automatic differentiation to perform simultaneous reconstruction of absorption, phase, and dark-field object images. Further, we demonstrate that the method has great potential for real-time quantitative phase imaging and wavefront sensing when combined with deep learning.

Qiao, Zhi (ORCID:0000000286285320)↗

Quantitative phase imaging by gradient retardance optical microscopy

Abstract Quantitative phase imaging (QPI) has become a vital tool in bioimaging, offering precise measurements of wavefront distortion and, thus, of key cellular metabolism metrics, such as dry mass and density. However, only a few QPI applications have been demonstrated in optically thick specimens, where scattering increases background and reduces contrast. Building upon the concept of structured illumination interferometry, we introduce Gradient Retardance Optical Microscopy (GROM) for QPI of both thin and thick samples. GROM transforms any standard Differential Interference Contrast (DIC) microscope into a QPI platform by incorporating a liquid crystal retarder into the illumination path, enabling independent phase-shifting of the DIC microscope's sheared beams. GROM greatly simplifies related configurations, reduces costs, and eradicates energy losses in parallel imaging modalities, such as fluorescence. We successfully tested GROM on a diverse range of specimens, from microbes and red blood cells to optically thick (~ 300 μm) plant roots without fixation or clearing.

47 OTHER INSTRUMENTATION↗

Pattern formation and transport for externally driven active matter on periodic substrates (a)

Abstract We investigate the transport of interacting active run-and-tumble particles moving under an external drift force through a periodic array of obstacles for increasing drive amplitudes. For high activity where the system forms a motility-induced phase-separated state, there are several distinct dynamic phases including a low drive pinned cluster phase, an intermediate uniform fluid, and a higher drive stripe crystal state. The transitions between the phases are correlated with signatures in the transport curves, differential mobility, and power spectra of the velocity fluctuations. In contrast, in the low activity regime the transport curves and power spectra undergo little change as a function of drive. We argue that in the high activity limit, the behavior is similar to that of driven solids on periodic substrates, while in the low activity limit the system behaves like a driven fluid.

36 MATERIALS SCIENCE↗

Distinctive features of structural evolution and thermodynamic response in wide-bandgap semiconductors driven by intense electronic excitation

Radiation-tolerant material selection requires balancing lattice rigidity, defect dynamics, and electronic stability, as shown by covalent SiC outperforming ionic Ga 2 O 3 and GaN under extreme environments. Responding to intense electronic excitation, irradiation-driven phase segregation (β → δ/κ in Ga 2 O 3 ) and core–shell track (disordered structure in GaN), accompanied by elemental redistribution, contrastingly, exceptional radiation tolerance manifested by comparatively minimal lattice distortion (0.17 % strain variation) was demonstrated in SiC. These differential responses are primarily attributed to two fundamental mechanisms: (i) thermodynamic driving forces governing defect migration and phase separation, and (ii) the synergistic effects of robust covalent bonding composition coupled with efficient defect recombination processes. Here, the stronger electron–phonon (e-ph) coupling in Ga 2 O 3 (4.34 × 1018 W m −3 K −1 ) and GaN (3.55 × 10 18 W m −3 K −1 ) enhances lattice energy deposition, triggering thermal spikes (ΔT ≫ T m ) and structural transition behaviors, whereas weaker e-ph coupling in SiC (3.69 × 10 18 W m −3 K −1 ), relatively high thermodynamic parameters and efficient energy dissipation suppress thermal spikes to maintaining lattice integrity. The photoresponse degradation driven by enhanced radiative recombination is dominant in N-doped SiC, while V-doped systems achieve defect-mediated photoconduction optimization characterized by abrupt current transitions, matching fluorescence yield evolutions, and directly connecting defect engineering to optoelectronic performance.

Intense electronic excitation↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.