SEARCH · Engineering Papers
Results for “Diamond detectors”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Latest results from the RD42 collaboration on the radiation tolerance of polycrystalline diamond detectors
Not provided.
Direct current response of a thin scCVD diamond detector under increased applied field to 14.1 MeV neutrons
This presentation along with a reading of the script will be recorded for a video presentation to be submitted and shown at the 2021 SPIE Optics + Photonics Conference
Novel ΔE-ΔE-E Diamond Detector Development (Final Report)
Explore the source record for details and available documents.
Multilayered Avalanche Diamond Detector for Fast Neutron Applications Project #: NLV-003-20 Year 3 of 3
Explore the source record for details and available documents.
Multi-Layered Avalanche Diamond Detector for Fast Neutron Applications
Explore the source record for details and available documents.
Comparison Table - Multi-Layered Avalanche Diamond Detector for Fast Neutron Applications
A table left out of OSTI #1975655
Proton radiation effects on carrier transport in diamond radiation detectors
Explore the source record for details and available documents.
Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors
Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.
Second Generation Multi-layer Avalanche Diamond (MAD) Detector Abstract
Abstract for public release to satisfy requirements of Copyright Assertion as outlined in our Prime Contract with DOE/NNSA. Approval for copyright assertion was received by HQ on 9/30/2024
ElectroMon Geometry Considerations: Simulations of Electron Transport to a Diamond-Based Detector
Particle-in-Cell simulations were performed to investigate the effects of electrode bias and pitch on the expected number of electrons arriving at a diamond-based detector at a set of relevant incident electron energies for electron cloud monitoring. Results of these simulations indicate that the pitch of the electrodes directly impacts the number of incident electrons based on complete opacity of the electrodes to the electrons; image charge does not play a role at any relevant electron energy. Positive bias on the incident electrodes directly increases the energy of the incident electrons, while negative bias reduces the energy and completely repels incoming electrons of energies lower than the applied bias. These results are intended to be used as input parameters for a solid-state simulation which will determine the collection efficiency of the electron-hole pairs produced within the diamond as a function of position and energy.
First measurements of energetic protons in Mega Amp Spherical Tokamak Upgrade (MAST-U)
First proton production rates from the d(d,p)t reaction in the Mega Amp Spherical Tokamak Upgrade (MAST-U) are measured. The data were taken during the MAST-U experimental campaign with an upgraded version of the proton detector (PD) previously used in MAST. The new detector array consists of three collimated silicon surface barrier detectors with a depletion depth of 300 μm and a collimated 120 μm thick diamond detector, mounted on the MAST-U reciprocating probe arm. This array measures the energies of unconfined energetic 3 MeV protons and 1 MeV tritons mainly produced by beam-thermal DD reactions during neutral beam injection heating. Diamond detectors have the potential to be uniquely suited to detect charged fusion products as they promise to be much more radiation resistant and much less sensitive to temperature variations compared to silicon-based detectors. Using silicon and diamond-based detectors simultaneously allowed us to directly compare the performance of these two detector types. PD particle rates measured during different plasma scenarios are presented and compared to neutron rates measured using the neutron camera upgrade and TRANSP predictions.
Modeling and Testing of Wireless Diamond Radiation Detector Prototype for Dry Spent Fuel Canister Monitoring.
Abstract not provided.
Determining spectral response of the National Ignition Facility particle time of flight diagnostic to x rays
The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond detector used for measuring multiple nuclear bang times at the National Ignition Facility. Due to the non-trivial, polycrystalline structure of these detectors, individual characterization and measurement are required to interrogate the sensitivity and behavior of charge carriers. In this paper, a process is developed for determining the x-ray sensitivity of PTOF detectors and relating it to the intrinsic properties of the detector. We demonstrate that the diamond sample measured has a significant non-homogeneity in its properties, with the charge collection well described by a linear model ax + b, where a = 0.63 ± 0.16 V –1 mm –1 and b = 0.00 ± 0.04 V –1 . Finally, we also use this method to confirm an electron to hole mobility ratio of 1.5 ± 1.0 and an effective bandgap of 1.8 eV rather than the theoretical 5.5 eV, leading to a large sensitivity increase.
Validation of neutron-induced reactions on natural carbon using an active target at neutron energies up to 22 MeV at LANSCE
A single crystal chemical vapor deposited (sCVD) diamond detector is used as an active target to measure neutron-induced reactions on natural carbon using the neutrons produced by spallation, with a broad energy spectrum at LANSCE. Additionally, the neutron-induced reactions are detected in the diamond as low as E n = 400 keV and up to approximately 100 MeV. Relative cross sections for C 12 ( n , α 0 ) , C 12 ( n , p 0 ) , C 12 ( n , d 0 + p 1 ) , and C 13 ( n , α 0 ) are reported up to E n = 22 MeV and comparisons on detected pulse-height spectra and detector response of scattering reactions are made with GEANT4 simulations using the ENDF/B-VIII.0 evaluated nuclear data library up to 20 MeV. The results are compared with past experimental data, including other works that incorporate diamond detectors as an active carbon target. In addition, R-matrix calculations for the C 13 + n system are presented.
Innovative /Low Cost/Large Area Single Crystal Diamond X-Ray Detector (Phase I Final Report)
Explore the source record for details and available documents.
Nuclear Science Symposium, 21st, Scintillation and Semiconductor Counter Symposium, 14th, and Nuclear Power Systems Symposium, 6th, Washington, D.C., December 11-13, 1974, Proceedings
Papers are presented dealing with latest advances in the design of scintillation counters, semiconductor radiation detectors, gas and position sensitive radiation detectors, and the application of these detectors in biomedicine, satellite instrumentation, and environmental and reactor instrumentation. Some of the topics covered include entopistic scintillators, neutron spectrometry by diamond detector for nuclear radiation, the spherical drift chamber for X-ray imaging applications, CdTe detectors in radioimmunoassay analysis, CAMAC and NIM systems in the space program, a closed loop threshold calibrator for pulse height discriminators, an oriented graphite X-ray diffraction telescope, design of a continuous digital-output environmental radon monitor, and the optimization of nanosecond fission ion chambers for reactor physics. Individual items are announced in this issue.
Radiation hard Ga 2 O 3 detectors for high energy physics
In this project, we explore the use of ultra-wide bandgap Ga 2 O 3 materials for fabricating next-generation radiation hard solid-state detectors for high energy physics (HEP) applications. As an emerging semiconductor, Ga 2 O 3 has ultra-wide bandgap (4.5-4.9 eV), high breakdown electric field (8 MV/cm) and much lower production cost compared with radiation hard diamond detectors, all of which make Ga 2 O 3 a great candidate material working in harsh radiation environment of future HEP experiments. The recent breakthrough of growth technologies of Ga 2 O 3 significantly improves the availability of large area single crystalline Ga 2 O 3 . We focus on an early proof-of-principle demonstration of Ga 2 O 3 detectors and conduct comprehensive material and detector characterization to evaluate the potential of the emerging Ga 2 O 3 as a new radiation-hard detector material. Our endeavors directly support the instrumentation development and update need of HEP experiments and fits very well into the DOE HEP “Detector R&D” research subprogram.