At least 37 records · Page 2

A high speed imaging system for nuclear diagnostics

A high speed imaging system based on state-of-the-art photosensor arrays was designed for use in nuclear diagnostics. The system is comprised of a front end rapid scan solid state camera, a high speed digitizer, and a PCM line driver in a downhole package and a memory buffer system in an uphole trailer. The downhole camera takes a snapshot of a nuclear device created flux stream, digitizes the image and transmits it to the uphole memory system before being destroyed. The memory system performs two functions: it retains the data for local display and processing by a microprocessor, and it buffers the data for retransmission at slower rates to a computational facility. In the talk, the impetus for such a system as well as its operation was discussed, along with systems under development which incorporate higher data rates and more resolution.

Eyer, H. H.

An experimental and computational study of thin-layer Rayleigh–Taylor instability development during deceleration with and without an externally applied magnetic field

The importance of mitigating the Rayleigh–Taylor instability (RTI) in inertial confinement fusion (ICF) is critical to successfully achieve high gain fusion yield. Consequently, understanding the seed mechanisms of RTI and the potential evolution of RTI in ICF relevant conditions is crucial. Single feature perturbations consistently demonstrate non-linear RTI evolution, for which an experimental platform on OMEGA-EP is developed. Manufacturing defects introduced into the target design require exploration of unanticipated changes to RTI development and an identification of targets that will still render quantifiable physics results. Consequently, it is presented that the inherent 3D nature of experimental targets necessitates 3D modeling for accurate design work and predictive modeling of experimental targets, especially when high resolution imaging diagnostics, like Fresnel Zone Plates, are utilized. A study of the morphology of the RTI evolution due to changing initial conditions and the presence of an externally applied magnetic field are also explored. Experimental data show thin-layer RTI morphology comparable to resistive magneto hydrodynamic 3D results. A discussion on the impacts of an externally applied magnetic field makes the case for continued efforts to observe a magnetic field's impact on RTI morphology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Novel soft x-ray multi-energy camera to study thermal plasmas on WEST

A multi-energy soft x-ray (SXR) pinhole camera has been built, calibrated and deployed on the WEST tokamak to aid the study of thermal plasmas. This novel imaging diagnostic technique employs a 2D pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. This innovation allows the simultaneous measurement of x-rays with space, time and energy resolution. Measurements at lower energy (2–6 keV) dominated by tungsten line emission are used to estimate the tungsten concentration and the plasma ΔZ eff . Measurements at higher energy (11–18 keV), where only continuum emission is present, are employed to infer the plasma electron temperature. Other applications of this powerful diagnostic include the determination of the plasma SXR centroid vertical position, characterization of tungsten UFOs and various real-time measurements.

electron temperature

Electric fields and stationary drift flows in the island divertor SOL of Wendelstein 7-X

Abstract In the island divertor scrape-off layer (SOL) of the Wendelstein 7-X stellarator, 2D-resolved Langmuir probe measurements uncover a complex spatial structure of electron temperature, density, and floating potential. Depending on details of magnetic island size and position, significant poloidal gradients and non-monotonic radial profiles are observed. The resulting electric fields imply the presence of sheared stationary drift flows with poloidal velocities of a few km/s, with flow channels as narrow as one cm. Such flows are observed with a gas puff imaging diagnostic in qualitative agreement with the probe results and imply a significant transport channel in the SOL. The 2D distribution of plasma parameters is intricately associated to the unique magnetic structure of the island divertor SOL and highlights the necessity for more accurate magnetic field reconstructions.

Killer, Carsten (ORCID:0000000177473066)

Photonuclear cross sections for the 197 Au ⁢(𝛾, 𝑝⁢𝑛)⁢ 195⁢𝑚 Pt reaction near threshold

Platinum radioisotopes are of growing interest for targeted cancer therapy and diagnostic imaging because their decay delivers highly localized radiation doses in tissue, herewith enabling precise DNA damage through Auger-electron emission. Developing production technologies that provide platinum isotopes with high specific activity is essential in radioisotope therapy. Photonuclear reactions on stable nuclei offer a viable accelerator-based route for isotope production when supported by reliable cross-section data. We report photonuclear cross-section measurements for the 197 Au(γ, pn) 195m Pt reaction at incident γ-ray energies of 27, 29, and 31 MeV using the activation method. The measurements were performed by irradiating a stack of concentric-ring gold targets with a quasi-monoenergetic γ-ray beam provided by the High Intensity Gamma-ray Source (HI γS). The induced 195m Pt activity was quantified using off-line γ-ray spectroscopy. These data provide the first experimental constraints on the 197 Au(γ, pn) 195m Pt cross section in the near-threshold region. Furthermore, the comparison of the measured excitation function to PHITS and TALYS calculations indicates that the reaction becomes measurable only near 30 MeV and that substantially higher bremsstrahlung end-point energies are required for practically meaningful production.

190 ≤ A ≤ 219

Black-box optimization of CT acquisition and reconstruction parameters: a reinforcement learning approach

Protocol optimization is critical in Computed Tomography (CT) for achieving desired diagnostic image quality while minimizing radiation dose. Due to the inter-effect of influencing CT parameters, traditional optimization methods rely on the testing of exhaustive combinations of these parameters. This poses a notable limitation due to the impracticality of exhaustive parameter testing. This study introduces a novel methodology leveraging Virtual Imaging Trials (VITs) and reinforcement learning to more efficiently optimize CT protocols. Computational phantoms with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction Toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was done using a Proximal Policy Optimization (PPO) agent which was trained to maximize the Detectability Index (d’) of the liver lesion for each reconstructed image. Results showed that our reinforcement learning approach found the absolute maximum d’ across the test cases while requiring 79.7% fewer steps compared to an exhaustive search, demonstrating both accuracy and computational efficiency, offering a efficient and robust framework for CT protocol optimization. The flexibility of the proposed technique allows for use of varying image quality metrics as the objective metric to maximize for. Our findings highlight the advantages of combining VIT and reinforcement learning for CT protocol management.

Fenwick, David [Duke University Medical Center]

Case Report: Differential diagnosis of hematuria in the emergency department: emphasizing double J stent-inferior vena cava fistula

Introduction Hematuria, a common clinical indicator of genitourinary tract pathology, arises from diverse etiologies including calculi, infections, malignancies, trauma, and iatrogenic causes. Initial evaluation requires hemodynamic assessment, identification of underlying causes, and urinary drainage optimization. This report highlights a rare case of iatrogenic hematuria secondary to double-J stent migration into the inferior vena cava. Case presentation A Chinese male presented with acute left flank pain and gross hematuria persisting for 4 h. Diagnostic imaging revealed a left ureteral stone, prompting double-J stent placement at a local hospital. Despite intervention, hematuria worsened, necessitating abdominal CT. Imaging identified proximal migration of the left double-J stent into the inferior vena cava, with no evidence of vascular injury. Due to concerns regarding inadequate drainage and infection risk, conservative management without catheter clamping was initiated prior to referral. Definitive treatment involved ureteroscopic stent removal under direct visualization at our institution, resulting in rapid symptom resolution. Conclusion This case emphasizes three critical clinical insights: (1) Persistent postoperative hematuria warrants consideration of iatrogenic causes, particularly following urologic device placement. (2) Imaging modalities, especially CT, are indispensable for detecting atypical stent migration. (3) Comprehensive history-taking must include prior urologic interventions to guide differential diagnosis. While double-J stent migration into major vessels remains exceptionally rare, its recognition prevents delayed management of potentially life-threatening complications. Clinicians should maintain heightened vigilance for device-related hematuria in patients with refractory symptoms post-procedurally, ensuring prompt imaging evaluation and multidisciplinary intervention when indicated.

Qi, Wenqi

A physical parameter method for the design of broad-band X-ray imaging systems to do coronal plasma diagnostics

The technique commonly used for the analysis of data from broad-band X-ray imaging systems for plasma diagnostics is the filter ratio method. This requires the use of two or more broad-band filters to derive temperatures and line-of-sight emission integrals or emission measure distributions as a function of temperature. Here an alternative analytical approach is proposed in which the temperature response of the imaging system is matched to the physical parameter being investigated. The temperature response of a system designed to measure the total radiated power along the line of sight of any coronal structure is calculated. Other examples are discussed.

Kahler, S.

An ultra-fast method for generating synthetic down-scattered neutron data for inertial confinement fusion implosions

In inertial confinement fusion experiments at the National Ignition Facility, asymmetries are probed by a variety of neutron diagnostics, including neutron imaging systems, real-time neutron activation diagnostics (RTNADs), and neutron spectrometers. It is often useful to generate synthetic data based on these diagnostics to validate and tune models. However, current methods of doing so using Monte Carlo particle tracing are time-consuming. In this paper, an ultra-fast method is presented for generating synthetic neutron images, RTNAD data, and spectrometry data using line integrals and 3D convolutions. While it does not contain as much physics as particle tracing codes, it is thousands of times faster and produces nearly identical data. This enables analysis techniques that depend on generating large amounts of synthetic data, which will prove very useful for the study of asymmetries going forward.

Deuterium

Exploiting a Shortcoming of Coupled-Cluster Theory: The Extent of Non-Hermiticity as a Diagnostic Indicator of Computational Accuracy

The fundamental non-Hermitian nature of the forms of the coupled-cluster (CC) theory widely used in quantum chemistry has usually been viewed as a negative, but the present paper shows how this can be used to an advantage. Specifically, the non-symmetric nature of the reduced one-particle density matrix (in the molecular orbital basis) is advocated as a diagnostic indicator of computational quality. In the limit of the full coupled-cluster theory [which is equivalent to full configuration interaction (FCI)], the electronic wave function and correlation energy are exact within a given one-particle basis set, and the symmetric character of the exact density matrix is recovered. The extent of the density matrix asymmetry is shown to provide a measure of “how difficult the problem is” (like the well-known T 1 diagnostic), but its variation with the level of theory also gives information about “how well this particular method works”, irrespective of the difficulty of the problem at hand. The proposed diagnostic is described and applied to a select group of small molecules, and an example of its overall utility for the practicing quantum chemist is illustrated through its application to the beryllium dimer (Be 2 ). Future application of this idea to excited states, open-shell systems, and symmetry-breaking problems and an extension of the method to the two-particle density are then proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Size and Structural Control of Mechanoluminescent ZnS:Mn 2+ Nanocrystals for Optogenetic Neuromodulation

Mechanoluminescent materials hold immense potential for various transformative applications, from medical imaging and diagnostics to health monitoring and wearable displays. Conventionally produced as bulk powders or microparticles, they face significant size limitations for advanced applications, particularly in biological systems and microscale devices. Here, this work presents an approach to ZnS:Mn 2+ nanocrystal synthesis that involves self-assembly and subsequent calcination. In addition to effective size control within the nanoscale, this approach promotes the formation of abundant stacking faults, significantly enhancing piezoelectric and mechanoluminescent properties by increasing trap density and reducing trap depth. Unlike mechanoluminescent materials produced using conventional methods, these nanocrystals demonstrate strong mechanoluminescence without requiring UV pre-excitation, and the light emission persists even after mechanical stress is removed. These advantageous properties make them promising candidates for optogenetic neuromodulation, as they can effectively trigger electrical signals in neurons upon ultrasound stimulation both with and without UV pre-excitation. The persistent mechanoluminescence prolongs the duration of neuronal electrical activity, providing an extended temporal window for neuromodulation compared to conventional mechanoluminescent materials. This study provides a scalable method for producing efficient mechanoluminescent nanoparticles and reveals the crucial role of particle size and defect structures in determining their mechanoluminescent behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Evolution of intermittent filaments in the scrape-off layer of NSTX

Filamentary structures naturally arise from background turbulence in the scrape-off layer (SOL) of plasmas, leading to significant particle and heat transport that can degrade overall plasma confinement. This enhanced transport can contribute to unacceptably high heat loads on plasma-facing components. As such, understanding the physics of SOL plasma filaments is critical for predicting and mitigating their effects in future fusion devices. On the National Spherical Torus Experiment (NSTX), plasma filaments—commonly referred to as “blobs”—were investigated using the gas-puff imaging (GPI) diagnostic in the edge and SOL regions. The analysis involved identifying, segmenting, and tracking the characteristic contours of the blobs in each frame of the GPI video sequences. Their evolution was characterized through shape descriptors, velocity, and angular velocity derived from their contour coordinates. The results indicate that as the blob area increases, their shapes become more concave and less circular, suggesting reduced structural stability in larger blobs. This result aligns with previous theoretical results where it was shown that larger blobs are more susceptible to instabilities [Krasheninnikov et al., J. Plasma Phys. 74, 679–717 (2008) and D'Ippolito et al., Phys. Plasmas 18, 060501 (2011)]. A positive correlation was observed between radial velocity and radial position, suggesting radially outward acceleration of the filaments, potentially driven by decreasing viscous drag toward the far SOL. Interestingly, blobs in background SOL turbulence exhibited minimal spinning in contrast to filaments originating from edge localized modes, which show substantial rotation during their paths [Lampert et al., Phys. Plasmas 29, 102502 (2022)]. Statistical analysis of the solidity and total curvature shape descriptors, along with their temporal evolution, revealed relatively broad, near-Gaussian distributions. This suggests that blob morphology is strongly influenced by stochastic turbulent processes in the surrounding plasma environment. Blob parameters were also compared with bulk plasma and radial profile measurements. Notable trends were found between blob rotation and poloidal velocity with collisionality and line-integrated density. These findings contribute to a deeper understanding of blob dynamics and provide valuable insights for refining SOL turbulence models.

Covariance and correlation

Tunable phase-change metasurfaces coupled with mid-infrared molecular vibrations

Chiral optical metasurfaces have emerged as a promising platform in coupling with molecular vibrational fingerprints through the enhanced light-matter interaction under different circularly polarized light illumination. Here, this work reports the mode coupling between the mid-infrared phonon vibrations of polymethyl methacrylate (PMMA) molecules and the thermally tunable chiral metasurfaces based on the phase-change material Ge₂Sb₂Te₅ (GST-225). Phase-change chiral metasurfaces with high circular dichroism (CD) in absorption and tunable plasmonic resonance in the frequency range of 48–56 THz are demonstrated, which covers the phonon vibrational frequency of PMMA molecules at 52 THz. The mode splitting features are observed in the absorption and CD spectra when the metasurface resonance is tuned across the phonon vibrational frequency of PMMA molecules during the phase transition of GST-225. The underlying mechanism of molecule-metasurface coupling is further revealed by studying the electric field and power loss density distributions of the phonon–plasmon coupled modes under both left-handed and right-handed circularly polarized (LCP and RCP) light. The demonstrated results show the potential of dynamically tunable chiral metasurfaces for the applications in label-free molecular sensing, biomedical diagnostics, thermal imaging, and mid-infrared photonics.

Tang, Haotian [Missouri Univ. of Science and Techn

MHD-induced SOL filaments and divertor heat flux striations in NSTX

Magnetohydrodynamic (MHD) activity in NSTX has been found to induce striated heat flux patterns at the divertor. These striated heat fluxes were previously interpreted as strike-point splitting caused by stochastic magnetic lobes near the X-point. Recent analysis indicates that MHD can directly generate filaments in the scrape-off layer (SOL), and the MHD-related filaments are consistent with the rotation and the frequency of the MHD. Magnetic field line tracing from the mid-plane of the MHD-related filaments to the divertor is consistent with the location of striated heat fluxes on the divertor. Additionally, gas puff imaging (GPI) diagnostic data shows the generation of regular blobs following each edge harmonic oscillation (EHO) toroidal mode number n = 1 perturbation, which indicates that the MHD perturbation directly drives the blobs. These blobs are responsible for the divertor heat flux striations. Here, this finding provides a new framework for understanding MHD-induced edge transport and has important implications for heat-load control in NSTX-U and future spherical tokamaks.

MHD

Regulation compliant AI for fusion: explainable image-based feedback control of divertor detachment in DIII-D tokamak

While artificial intelligence (AI) has been promising for fusion control, its inherent black-box nature will make compliant implementation in regulatory environments a challenge. This study implements and validates a real-time AI-enabled linear and interpretable control system for successful divertor detachment control with the DIII-D lower divertor camera. Using D 2 gas, we demonstrate successful feedback divertor detachment control with a mean absolute difference of 2% from the target for both detachment and reattachment. This automatic training and linear processing framework can be extended to any image-based diagnostic for future fusion reactors.

computer vision

Optimizing transmit field inhomogeneity of parallel RF transmit design in 7T MRI using deep learning

Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) provides a higher signal-to-noise ratio and, thereby, higher spatial resolution. However, UHF MRI introduces challenges such as transmit radiofrequency (RF) field (B+1) inhomogeneities, leading to uneven flip angles and image intensity anomalies. These issues can significantly degrade imaging quality and its medical applications. This study addresses B+1 field homogeneity through a novel deep learning-based strategy. Traditional methods like Magnitude Least Squares (MLS) optimization have been effective but are time-consuming and dependent on the patient’s presence. Recent machine learning approaches, such as RF Shim Prediction by Iteratively Projected Ridge Regression and deep learning frameworks, have shown promise but face limitations like extensive training times and oversimplified architectures. We propose a two-step deep learning strategy. First, we obtain the desired reference RF shimming weights from multi-channel B+1 fields using random-initialized Adaptive Moment Estimation. Then, we employ Residual Networks (ResNets) to train a model that maps B+1 fields to target RF shimming outputs. Our approach does not rely on pre-calculated reference optimizations for the testing process and efficiently learns residual functions. Comparative studies with traditional MLS optimization demonstrate our method’s advantages in terms of speed and accuracy. The proposed strategy achieves a faster and more efficient RF shimming design, significantly improving imaging quality at UHF. This advancement holds potential for broader applications in medical imaging and diagnostics.

Lu, Zhengyi [Vanderbilt University]

Review of Ultrasonic Methods for Monitoring, Damage Detection, and Processing of Lithium-Ion Batteries Throughout Their Life Cycle

Lithium-ion batteries (LIBs) are the leading technology used in consumer electronics, electric vehicles, and grid-level electrochemical energy storage applications. The ever-increasing use of LIBs has highlighted a gap in understanding of their behavior throughout their life cycle. Current monitoring systems rely on electrical and sometimes temperature measurements to assess the internal state which limits information about complex electrochemical processes. In response, ultrasonic testing (UT) has shown promise for non-invasive assessment due to its ease of use and sensitivity to mechanical changes which are correlated with electrochemical changes within the battery. We summarize the research in UT methods applied to LIBs throughout their life cycle. We also discuss physics-based and data-driven modeling approaches used to interpret ultrasonic signals in the context of LIBs, with an emphasis on the existing challenge of establishing rigorous links between electrochemical behavior and elastic and poroelastic wave physics to gain insight regarding physical changes in the LIB that can be directly measured using UT. Finally, we discuss the challenges of implementing UT across the LIB life cycle and identify opportunities for further research. This review aims to provide helpful guidance to researchers and practitioners of UT in the growing field of UT for electrochemical battery systems.