Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Determinants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

BINARY CONTAMINATION IN THE SEGUE SAMPLE: EFFECTS ON SSPP DETERMINATIONS OF STELLAR ATMOSPHERIC PARAMETERS

We examine the effects that unresolved binaries have on the determination of various stellar atmospheric parameters for targets from the Sloan Extension for Galactic Understanding and Exploration (SEGUE) using numerical modeling, a grid of synthetic spectra, and the SEGUE Stellar Parameter Pipeline (SSPP). The SEGUE survey, a component of the Sloan Digital Sky Survey-II (SDSS-II) project focusing on Galactic structure, provides medium resolution spectroscopy for over 200,000 stars of various spectral types over a large area on the sky. To model undetected binaries that may be in this sample, we use a variety of mass distributions for the primary and secondary stars in conjunction with empirically determined relationships for orbital parameters to determine the fraction of G - K dwarf stars, defined by SDSS color cuts as having 0.48 {<=} (g - r){sub 0} {<=} 0.75, that will be blended with a secondary companion. We focus on the G-K dwarf sample in SEGUE as it records the history of chemical enrichment in our galaxy. To determine the effect of the secondary on the spectroscopic parameters, specifically effective temperature, surface gravity, metallicity, and [{alpha}/Fe], we synthesize a grid of model spectra from 3275 to 7850 K and [Fe/H] = -0.5 to -2.5 from MARCS model atmospheres using TurboSpectrum. These temperature and metallicity ranges roughly correspond to a stellar mass range of 0.1-1.0 M{sub sun}. We assume that both stars in the pair have the same metallicity. We analyze both 'infinite' signal-to-noise ratio (S/N) models and degraded versions of the spectra, at median S/N of 50, 25, and 10. By running individual and combined spectra (representing the binaries) through the SSPP, we determine that {approx}10% of the blended G - K dwarf pairs with S/N {>=} 25 will have their atmospheric parameter determinations, in particular temperature and metallicity, noticeably affected by the presence of an undetected secondary; namely, they will be shifted beyond the expected SSPP uncertainties. Shifts in [Fe/H] largely result from the shifts in temperature caused by a secondary. The additional uncertainty from binarity in targets with S/N {>=} 25 is {approx}80 K in temperature and {approx}0.1 dex in [Fe/H]. The effect on surface gravity and [{alpha}/Fe] is even smaller. As the S/N of targets decreases, the uncertainties from undetected secondaries increase. For S/N = 10, 40% of the G-K dwarf sample is shifted beyond expected uncertainties for this S/N in effective temperature and/or metallicity. To account for the additional uncertainty from binary contamination at an S/N {approx} 10, the most extreme scenario, uncertainties of {approx}140 K and {approx}0.17 dex in [Fe/H] must be added in quadrature to the published uncertainties of the SSPP.

79 ASTRONOMY AND ASTROPHYSICS↗

ITAR: A modified TAR method to determine depth dose distribution for an ophthalmic device that performs kilovoltage x-ray pencil-beam stereotaxy

Purpose: New technology has been developed to treat age-related macular degeneration (AMD) using 100 kVp pencil-beams that enter the patient through the radio-resistant sclera with a depth of interest between 1.6 and 2.6 cm. Measurement of reference and relative dose in a kilovoltage x-ray beam with a 0.42 cm diameter field size and a 15 cm source to axis distance (SAD) is a challenge that is not fully addressed in current guidelines to medical physicists. AAPM's TG-61 gives dosimetry recommendations for low and medium energy x-rays, but not all of them are feasible to follow for this modality. Methods: An investigation was conducted to select appropriate equipment for the application. PTW's Type 34013 Soft X-Ray Chamber (Freiburg, Germany) and CIRS's Plastic Water LR (Norfolk, VA) were found to be the best available options. Attenuation curves were measured with minimal scatter contribution and thus called Low Scatter Tissue Air Ratio (LSTAR). A scatter conversion coefficient (C{sub scat}) was derived through Monte Carlo radiation transport simulation using MCNPX (LANL, Los Alamos, NM) to quantify the difference between a traditional TAR curve and the LSTAR curve. A material conversion coefficient (C{sub mat}) was determined through experimentation to evaluate the difference in attenuation properties between water and Plastic Water LR. Validity of performing direct dosimetry measurements with a source to detector distance other than the treatment distance, and therefore a different field size due to a fixed collimator, was explored. A method—Integrated Tissue Air Ratio (ITAR)—has been developed that isolates each of the three main radiological effects (distance from source, attenuation, and scatter) during measurement, and integrates them to determine the dose rate to the macula during treatment. Results: LSTAR curves were determined to be field size independent within the range explored, indicating that direct dosimetry measurements may be performed with a source to detector distance of 20 cm even though the SAD is 15 cm during treatment. C{sub scat} varied from 1.102 to 1.106 within the range of depths of interest. The experimental variance among repeated measurements of C{sub mat} was larger than depth dependence, so C{sub mat} was estimated as1.019 for all depths of interest. Conclusions: Equipment selection, measurement techniques, and formalism for the determination of dose rate to the macula during stereotaxy for AMD have been determined and are strongly recommended by the authors of this paper to be used by clinical medical physicists.

61 RADIATION PROTECTION AND DOSIMETRY↗

Molecular structure determination from x-ray scattering patterns of laser-aligned symmetric-top molecules.

We investigate the molecular structure information contained in the x-ray diffraction patterns of an ensemble of rigid CF{sub 3}Br molecules aligned by an intense laser pulse at finite rotational temperature. The diffraction patterns are calculated at an x-ray photon energy of 20 keV to probe molecular structure at angstrom-scale resolution. We find that a structural reconstruction algorithm based on iterative phase retrieval fails to extract a reliable structure. However, the high atomic number of Br compared with C or F allows each diffraction pattern to be treated as a hologram. Using this approach, the azimuthal projection of the molecular electron density about the alignment axis may be retrieved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum Package 2.0: An Open-Source Determinant-Driven Suite of Programs

Quantum chemistry is a discipline which relies heavily on very expensive numerical computations. The scaling of correlated wave function methods lies, in their standard implementation, between O(N-5) and O(e(N)), where N is proportional to the system size. Therefore, performing accurate calculations on chemically meaningful systems requires (i) approximations that can lower the computational scaling and (ii) efficient implementations that take advantage of modern massively parallel architectures. QUANTUM PACKAGE is an open-source programming environment for quantum chemistry specially designed for wave function methods. Its main goal is the development of determinant-driven selected configuration interaction (sCI) methods and multireference second-order perturbation theory (PT2). The determinant-driven framework allows the programmer to include any arbitrary set of determinants in the reference space, hence providing greater methodological freedom. The sCI method implemented in QUANTUM PACKAGE is based on the CIPSI (Configuration Interaction using a Perturbative Selection made Iteratively) algorithm which complements the variational sCI energy with a PT2 correction. Additional external plugins have been recently added to perform calculations with multireference coupled cluster theory and range-separated density-functional theory. All the programs are developed with the IRPF90 code generator, which simplifies collaborative work and the development of new features. QUANTUM PACKAGE strives to allow easy implementation and experimentation of new methods, while making parallel computation as simple and efficient as possible on modern supercomputer architectures. Currently, the code enables, routinely, to realize runs on roughly 2 000 CPU cores, with tens of millions of determinants in the reference space. Moreover, we have been able to push up to 12 288 cores in order to test its parallel efficiency. In the present manuscript, we also introduce some key new developments: (i) a renormalized second-order perturbative correction for efficient extrapolation to the full CI limit and (ii) a stochastic version of the CIPSI selection performed simultaneously to the PT2 calculation at no extra cost.

Garniron, Yann↗

The equation of state of 5-nitro-2,4-dihydro-1,2,4,-triazol-3-one determined via in-situ optical microscopy and interferometry measurements

Quasi-hydrostatic high-pressure equations of state (EOS) are typically determined, for crystalline solids, by measuring unit-cell volumes using x-ray diffraction (XRD) techniques. However, when characterizing low-symmetry materials with large unit cells, conventional XRD approaches may become problematic. To overcome this issue, we examined the utility of a “direct” approach toward determining high pressure material volume by measuring surface area and sample thickness using optical microscopy and interferometry (OMI), respectively. We have validated this experimental approach by comparing results obtained for 2,4,6-triamino-1,3,5-trinitrobenzene TATB with an EOS determined from synchrotron XRD measurements; and, a good match is observed. We have measured the high pressure EOS of 5-nitro-2,4-dihydro-1,2,4,-triazol-3-one (α-NTO) up to 28 GPa. No high-pressure XRD EOS data have been published on α-NTO, probably due to its complex crystal structure. The results of this study suggest that OMI is a reliable and versatile alternative for determining EOSs, especially when conventional methodologies are impractical.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System

Frequency control from photovoltaic (PV) power plants has great potential to address the frequency response challenge of the power system with high penetrations of renewable generation. Using model-based approaches to determine the optimal PV headroom reserve, however, requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic 1-day operation profile of the WECC system and demonstrates a savings of more than 40% PV headroom compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

frequency control↗

Experimental determination of electron attenuation lengths in complex materials by means of epitaxial film growth: advantages and challenges

Accurate electron attenuation lengths are of critical importance in using electron spectroscopic methods to quantitatively characterize complex materials. Here we show that analysis of core-level and valence-band x-ray photoelectron spectra excited with monochromatic AlK? x-rays from the substrate and measured as a function of film thickness can be used to determine electron attenuation lengths in epitaxial SrTiO3 films on Ge(001). Closely lattice-matched epitaxial heterojunctions are ideal systems for determining attenuation lengths provided the films grow in a layer-by-layer fashion, leading to atomically flat surfaces, and the buried interfaces are atomically abrupt. In principle, either the rate of attenuation of substrate peak intensities or the rate of increase of film peak intensities can be used for this purpose. However, we find that structural nonuniformities in the films reduce the accuracy of electron attenuation lengths determined from photoelectrons that originate within the films. A more reliable source of information is found in photoelectrons from the substrate which traverse the film. By using the energy dependence of calculated electron attenuation lengths from the NIST database in combination with Ge 3d core and Ge-derived valence band intensities, we determine electron attenuation length as a function of kinetic energy for SrTiO3.

Chambers, Scott A.↗

Consequences of CCD imperfections for cosmology determined by weak lensing surveys: from laboratory measurements to cosmological parameter bias

Weak gravitational lensing causes subtle changes in the apparent shapes of galaxies due to the bending of light by the gravity of foreground masses. By measuring the shapes of large numbers of galaxies (millions in recent surveys, up to tens of billions in future surveys) we can infer the parameters that determine cosmology. Imperfections in the detectors used to record images of the sky can introduce changes in the apparent shapes of galaxies, which in turn can bias the inferred cosmological parameters. In this paper we consider the effect of two widely discussed sensor imperfections: tree rings, due to impurity gradients that cause transverse electric fields in the charge-coupled devices (CCDs), and pixel size variation, due to periodic CCD fabrication errors. These imperfections can be observed when the detectors are subject to uniform illumination (flat-field images). We develop methods to determine the spurious shear and convergence (due to the imperfections) from the flat-field images. We calculate how the spurious shear when added to the lensing shear will bias the determination of cosmological parameters. We apply our methods to candidate sensors of the Large Synoptic Survey Telescope (LSST) as a timely and important example, analyzing flat-field images recorded with LSST prototype CCDs in the laboratory. We find that tree rings and periodic pixel size variation present in the LSST CCDs will introduce negligible bias to cosmological parameters determined from the lensing power spectrum, specifically w, Ω{sub m}, and σ{sub 8}.

79 ASTRONOMY AND ASTROPHYSICS↗

Group Additivity Determination for Enthalpies of Formation of Carbenium Ions

Modeling of acid-catalyzed hydrocarbon conversion processes at the mechanistic level requires rate coefficients for a large number of reactions. The computational demand of finding activation energy barriers for each reaction is substantially reduced by employing structure–reactivity correlations such as the Evans–Polanyi relationship that correlates activation energy with the enthalpy of reaction. However, there are many species for which the enthalpies of formation are unknown. Therefore, group additivity methods to specify enthalpies of formation for each species involved in the reaction network are valuable. Quantum mechanical (QM) calculations and isodesmic reactions were used to calculate enthalpies of formation for a number of acyclic and cyclic carbenium ions, including allylic carbenium ions. These values compare favorably with experimental values, establishing Gaussian-4 as an accurate QM method for these calculations. Using these values, Benson-type group additivity values for enthalpies of formation were then derived through multiple linear regression. Enthalpies of formation values calculated from the group additivity scheme capture experimental and QM enthalpies of formation well and enhance the range of species that can be described by the group additivity approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thickness determination of few-layer hexagonal boron nitride films by scanning electron microscopy and Auger electron spectroscopy

We assess scanning electron microscopy (SEM) and Auger electron spectroscopy (AES) for thickness measurements on few-layer hexagonal boron nitride (h-BN), the layered dielectric of choice for integration with graphene and other two-dimensional materials. Observations on h-BN islands with large, atomically flat terraces show that the secondary electron intensity in SEM reflects monolayer height changes in films up to least 10 atomic layers thickness. From a quantitative analysis of AES data, the energy-dependent electron escape depth in h-BN films is deduced. The results show that AES is suitable for absolute thickness measurements of few-layer h-BN of 1 to 6 layers.

36 MATERIALS SCIENCE↗

DETERMINATION OF IONIZATION ENERGIES OF C {sub n} N (n = 4-12): VACUUM ULTRAVIOLET PHOTOIONIZATION EXPERIMENTS AND THEORETICAL CALCULATIONS

Results from single photon vacuum ultraviolet photoionization of astrophysically relevant C{sub n} N clusters, n = 4-12, in the photon energy range of 8.0 eV-12.8 eV are presented. The experimental photoionization efficiency curves, combined with electronic structure calculations, provide improved ionization energies of the C{sub n} N species. A search through numerous nitrogen-terminated C{sub n} N isomers for n = 4-9 indicates that the linear isomer has the lowest energy, and therefore should be the most abundant isomer in the molecular beam. Comparison with calculated results also shed light on the energetics of the linear C{sub n} N clusters, particularly in the trends of the even-carbon and the odd-carbon series. These results can guide the search of potential astronomical observations of these neutral molecules together with their cations in highly ionized regions or regions with a high UV/VUV photon flux (ranging from the visible to VUV with flux maxima in the Lyman-{alpha} region) in the interstellar medium.

79 ASTRONOMY AND ASTROPHYSICS↗