Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Detector efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance Characterization of FB-Line Neutron Multiplicity Counter and Large Neutron Multiplicity Counter

Savanah River National Laboratory’s (SRNL) Nuclear Measurements group was tasked with characterizing the performance of two neutron multiplicity counters located at SRNL. Characterization measurements were made to determine the gate width, pre-delay, deadtime parameters, triples and doubles gate fractions, detector efficiency, and operating high voltage for the Large Neutron Multiplicity Counter (LNMC) and the FB Line Neutron Multiplicity Counter (FBLNMC). The parameters were determined, shown below, and were, as to be expected, slightly different than the previous calibrations, which were performed over 20 years ago. Several Pu samples were measured to validate the characterizations of the FBLNMC and LNMC. The measurements determined the sample Pu-240 mass within <2% deviation for the pure plutonium samples and ~8% for the mixed oxide sample. The pure Pu samples had significantly better accuracy compared with the impure mixed oxide sample due to the lack of induced fission or alpha,n neutrons from impurities. Overall, the characterization of the neutron multiplicity counters, and the determination of their operability has been completed successfully.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Absolute Efficiency Characterization of Neutron Detectors within Radioisotope Identification Devices [Slides]

Some Radioisotope Identification Devices (RIIDs) have a low efficiency neutron detector that can provide a neutron singles counting rate along with the primary gamma spectra that can be used to identify a radioisotope. When we know absolute efficiency, other characteristics of a radioisotope can be estimated such as mass or source strength when accompanied by the identity of the isotope and other observable variables. This study focuses on characterizing and comparing the absolute neutron efficiencies of some commonly used RIIDs: the ORTEC Detective X, ORTEC RADEAGLET-R, and FLIR IDentifinder 2.

Nuclear Criticality Safety Program (NCSP)

Scintillation light calibrations, systematic uncertainties, and triggering efficiency in the MicroBooNE detector

Scintillation light, produced alongside ionisation charge from particle interactions, plays a critical role in liquid argon time projection chamber (LArTPC) detectors. A detailed understanding of its production and detection mechanisms is essential for robust calibration, systematic uncertainty evaluation, and physics analysis. This article describes the MicroBooNE light simulation, light-based triggering schemes, photomultiplier tube gain calibration, light response stability, and light-based systematic uncertainties over the course of five years of data collection. In addition, we present a measurement of scintillation light triggering efficiency, focusing on the lowest-light regime relevant to rare-event searches and low-energy neutrino interactions. Finally, we discuss two notable observations in MicroBooNE's data, both reported here for the first time: an approximately 50% decline in MicroBooNE's light yield over time, concentrated in the first two years of running; and a higher than expected O(200 kHz) rate of single photoelectron noise. The results presented provide an important benchmark of long-term light detection performance in LArTPC neutrino detectors.

Abratenko, P. [Tufts U.]

Supernova electron-neutrino interactions with xenon in the nEXO detector

Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-𝛽 decay detector (∼5 metric ton, 90% 136 Xe, 10% 134 Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the Model of Argon Reaction Low Energy Yields (MARLEY) event generator. We find good agreement between MARLEY’s predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector’s efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5–8 kpc from Earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Determining the Efficiency of EMPHATICs Silicon Strip Detectors (SSDs)

EMPHATIC is an experiment at Fermilab which aims to reduce current neutrino flux uncertainties. This report discusses the limitations current neutrino flux uncertainties places on large scale neutrino experiments, provides background on the EMPHATIC experiment, and details the project of determining the efficiency of the Silicon Strip Detectors (SSDs) used in EMPHATIC. As part of the data analysis process and in order to increase the accuracy of EMPHATIC’s simulations a representation of efficiency of each SSD is required. To achieve this a data-driven analysis was performed on EMPHATIC's collected data using the Root and Art frameworks. Visual and numerical representations of efficiency were determined. The average efficiency over all SSDs is 98.58\%, however this number deflated as it includes known bad channels.

Olson, V. [Illinois U., Urbana (main)]

Efficient Optimization of Plasma Radiation Detector Configurations using Imperfect Inference Models

The configurations of instruments fielded on an experiment affect the amount of information captured and the quality of subsequent inference. Here, we investigate the problem of optimizing plasma x-ray radiation detectors in a magneto-inertial fusion experiment at Sandia National Laboratories. It is impossible to directly measure properties such as the temperature of the thermonuclear fusion plasma produced in these experiments because of the extreme environment and destructive nature of the experiment. Among other diagnostics, several detectors are placed with significant standoff from the fusion target to capture the x-rays emitted by the fusion plasma, which can be used to infer some of its properties. To optimize the configuration of these detectors, a high-fidelity model (HFM) is used for simulating outputs and a low-fidelity model (LFM) is used for inference. We develop methods based on A- and L-optimality criteria that are efficient to compute while explicitly accounting for the discrepancy between the HFM and the LFM. The method allows us to find detector configurations that perform similarly to or better than the configuration obtained using an existing sampling-based optimization method while decreasing computational time by a factor of 50. Supplementary materials for this article are available online, including a standardized description of the materials available for reproducing the work.

Bayesian optimization

Development of thin-gap GEM- μ RWELL hybrid detectors

Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles impacting at a large angle with respect to the axis perpendicular to detector plane, the spatial resolution degrades significantly because of the long trail of ionization charges produced in clusters all along the track in the drift region of the detector. The long ionization charge trail results in registering hits from large number of strips in the readout plane which makes it challenging to precisely reconstruct the particle’s position using simple center of gravity algorithm. As a result, the larger the drift gap, the more severe the deterioration of spatial resolution for inclined tracks. For the same reason, the position resolution is also severely degraded in a large magnetic field, where the Lorentz E x B effect causes the ionization charges to follow a curved and longer path in the detector gas volume. In this paper, we report on the development of thin-gap MPGDs as a way to maintain excellent spatial resolution capabilities of MPGD detectors over a wide angular range of incoming particles. In a thin-gap MPGD, the thickness of the gas volume in the drift region is reduced from typically 3 mm to 1 mm or less. We present preliminary test beam results demonstrating the improvement in spatial resolution from 400 m with a standard 3 mm gap μ RWELL prototype to ~140 μ m with a double amplification GEM- μ RWELL thin-gap hybrid detector. Here, we also discuss the impact of a thin-gap drift volume on other aspects of the performance of MPGD technologies such as the efficiency and detector stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Understanding the optoelectronic properties of doped 2D organic-inorganic halide perovskite quantum wells: towards efficient ultrafast quantum well IR photodetectors

This project, titled “Understanding the optoelectronic properties of doped 2D organic-inorganic halide perovskite quantum wells: towards efficient quantum well IR photodetectors”, was funded by the U.S. Department of Energy to explore a new class of materials that could make future light-sensing technologies, such as infrared (IR) cameras and detectors more efficient, affordable, and widely available. The research focused on special layered materials called 2D halide perovskites, which are made up of alternating organic and inorganic layers only a few atoms thick. These materials can be tuned at the atomic level to absorb and emit light in precise ways, making them very attractive for use in optoelectronic devices. The main goal of the project was to understand how these perovskite materials absorb light and move electrical charges at very small scales. However, this is not an easy task. These materials often contain a mixture of different structures in the same film, and traditional tools like regular absorption or photoluminescence spectroscopy are not good at telling those structures apart. To solve this, the research team, led by Professor Luisa Whittaker-Brooks at the University of Utah developed a powerful method called electroabsorption spectroscopy. This technique uses electric fields to highlight the unique “fingerprints” of different excitons, which are tiny packets of energy formed when light hits the material. By using this method, the team could separate overlapping signals and learn exactly how the materials respond to light under different conditions, including changes in temperature, thickness, and chemical makeup.

36 MATERIALS SCIENCE

Simulating the Phonon Collection Efficiency in Kinetic Inductance Phonon-Mediated Detectors

Kinetic inductance phonon-mediated (KIPM) detectors use microwave kinetic inductance detectors (MKIDs) to read out phonon signals in the substrate. They are a promising class of detectors to be used in light dark matter (DM) searches due to their potential eV-scale sensitivity and native frequency-domain multiplexability. In order to improve upon the design of these detectors, simulations are needed to understand the effects of detector design on measurable physical parameters including the phonon collection efficiency, $\eta_{ph}$, which is defined as the ratio of phonon energy detected by the sensitive target element to the incident energy deposited in the substrate. This work simulates the phonon collection efficiency for two existing detector architectures to study phonon absorption at substrate-sensor interfaces and phonon loss to non-sensitive detector elements.

Dang, Stella Q.

Prospects for measuring the time variation of astrophysical neutrino sources at dark matter detectors

We study the prospects for measuring the time variation of solar and atmospheric neutrino fluxes at future large-scale xenon and argon dark matter detectors. For solar neutrinos, a yearly time variation arises from the eccentricity of Earth’s orbit and, for charged current interactions, from a smaller energy-dependent day-night variation due to flavor regeneration as neutrinos travel through Earth. For a 100-ton xenon detector running for ten years with a xenon-136 fraction of ≲ 0.1 % , in the electron recoil channel a time-variation amplitude of about 0.8% is detectable with a power of 90% and the level of significance of 10%. This is sufficient to detect time variation due to eccentricity, which has amplitude of ∼ 3 % . In the nuclear recoil channel, the detectable amplitude is about 10% under current detector resolution and efficiency conditions, and this generally reduces to about 1% for improved detector resolution and efficiency, the latter of which is sufficient to detect time variation due to eccentricity. Our analysis assumes both known and unknown periods. We provide scalings to determine the sensitivity to an arbitrary time-varying amplitude as a function of detector parameters. Identifying the time variation of the neutrino fluxes will be important for distinguishing neutrinos from dark matter signals and other detector-related backgrounds and extracting properties of neutrinos that can be uniquely studied in dark matter experiments. Published by the American Physical Society 2024

Zhuang, Yi (ORCID:0000000277138724)

Machine learning inversion of interatomic force constants from single-crystal inelastic neutron scattering

Atomic vibrations govern many macroscopic properties of materials, but experiments to comprehensively probe them remain challenging. Inelastic neutron scattering (INS) is a powerful technique to map phonon dispersions in crystals, especially when leveraging modern time-of-flight (ToF) spectrometers with large detectors. However, efficiently and robustly extracting interatomic force constants (FCs) parameterizing phonon dynamics from experimental spectra remains a bottleneck due to the complexity and high dimensionality of ToF INS datasets. Here, we present a machine learning approach for the direct inversion of FCs from single-crystal INS measurements. The framework leverages synthetic training data generated using universal machine-learned force fields and an efficient physics-based forward model. We benchmark two neural architectures–one emphasizing structured latent representation learning and the other direct, supervised spectral regression–across simulated datasets for two materials under idealized and noisy conditions. The latent-representation model is subsequently applied to experimental single-crystal INS data on germanium. The model is shown to reproduce FCs derived from both first-principles simulations and from iterative optimization, and furthermore achieves reliable inference even from sparse, single-orientation measurements representing short data acquisitions. Analysis of the learned latent space reveals semantically continuous and physically interpretable encodings that support strong cross-domain generalization. By bridging theoretical and experimental domains, we establish a path toward rapid inversion of experimental spectra and data-driven interpretation of temperature-dependent lattice dynamics.

42 ENGINEERING

Calibration of a broadband x-ray crystal spectrometer using a continuum x-ray source and photon-counting detectors

We report measurements of sensitivity of a broadband (≃20–30 keV) x-ray crystal spectrometer using a bremsstrahlung continuum x-ray source and several detectors, including an energy-discriminating photon-counting point detector (Si drift diode, Amptek Inc.), imaging hybrid photon-counting detectors (Eiger2-Si and Eiger2-CdTe, DECTRIS Ltd.), and image plates (SR type). Sensitivity is defined as a ratio of the crystal-reflected energy-position-dispersed spectrum measured by a given detector to the incident non-dispersed spectrum measured using the energy-discriminating point detector. The sensitivity derived from data measured exclusively by the point detector is considered detector-independent and serves as a reference. The sensitivities derived from data collected with the hybrid photon-counting detectors were matched to the reference using a scale factor of 1.05. The image plate-derived sensitivities required a scale factor of 1.16 to match the reference. Furthermore, the resulting mismatch in the shapes of all measured scaled sensitivities in the range of the spectrometer was ≲±10%, while the mismatch between the shapes of the sensitivities corresponding to the Si-based detectors was ≲±2.5%.

Crystal optics

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS

Simulating the Phonon Collection Efficiency in KIPMDs

Kinetic inductance phonon-mediated (KIPM) detectors are superconducting microcalorimeters that use microwave kinetic inductance detectors (MKIDs) to read out phonon signals in the device substrate. In order to improve the design of these detectors, we need to understand the effect of various detector design elements on the physical processes that take place within the detector through simulation efforts. One figure of merit for KIPM detectors is the phonon collection efficiency, $\eta_{ph]$, defined as the ratio of phonon energy detected by the sensitive element in the detector and the energy deposited by incident phonons in the substrate. Comparing the phonon collection efficiency obtained in simulation and in experiment for the same detector geometry provides insight to physical processes in the detector, such as phonon absorption at substrate-sensor interfaces and phonon loss to non-sensitive detector elements. This work models the phonon collection efficiency in two KIPM detectors with different geometries, one located at the Fermi National Accelerator Laboraory, the other located at the SLAC National Accelerator Laboratory.

Dang, Stella Q.

Many-body Nuclear Dynamics

The principal goal of this work was to better understand the fusion of neutron-rich nuclei a topic relevant to the fields of both nuclear physics and nuclear astrophysics. The work provides insight into the structure and reactions of neutron-rich nuclei namely the extent of their neutron density distribution and its polarizability. By comparing the fusion excitation functions for a chain of isotopes with a common target nucleus changes in the attractive nuclear potential are assessed. This change in the attractive potential is related to changes in the neutron density distribution with increasing number of neutrons or changes in fusion dynamics with increasing neutron number. The impact of the pairing of valence neutrons and protons on the fusion cross-section is also examined. Measurement of an isotopic chain is a powerful tool to address this topic. The experimental program made use of several different accelerator facilities. The core of the experimental work involved experiments at the ReA3 accelerator and the Facility for Rare Isotope Beams (FRIB) situated at Michigan State University, at GANIL, the French national nuclear physics laboratory, and the University of Notre Dame. At ReA3 the degree to which α-clusters associated with fusion of 28,30,32 Si + 28 Si result from the collision dynamics or reflect an initial α-cluster structure was explored. Alpha clusters observed in fusion reactions exceed the predictions of the standard statistical model. This experiment provides a measure of how clusterization is impacted by the increasing neutron-richess of the system. In the experiment at GANIL we investigated fusion in 19 O + 12 C and 20 O + 12 C. This experiment utilized the recently developed active-target detector MuSIC@Indiana. Using this proven, highly efficient, active-target detector we measured the fusion excitation function for these neutron-rich systems. Grounded by these experimental measurements, theoretical models were used to examine the role of unpaired valence neutrons on the fusion cross-section at energies just above the fusion barrier.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Constraining the impact of chlorine as a neutron absorber in next-gen fast reactor designs

The role of chlorine as a neutron poison and as a seed for producing radioactive waste in nuclear systems has driven a renewed interest to improve its nuclear data uncertainties. Additionally, basic and applied science programs that use CLYC (Cs 2 LiYCl 6 :Ce) detectors for neutron spectroscopy and monitoring are also very sensitive to any change in chlorine nuclear data for simulations of the detector response. In this work, sensitivities relevant for these different applications are addressed through simulations of the efficiency of CLYC detectors in a fast fission spectrum when applying new chlorine nuclear data as input. These simulations are validated by an experimental measurement using CLYC detectors coupled to an ionization chamber loaded with a 252 Cf spontaneous fission source. The results are then used to obtain the first reliable direct measurement of the 35 Cl(n,p 0 ) and summed Cl(n,p+n,α) fission spectrum average cross sections, found to be 54.7(32) and 105.0(98) mb, respectively. The results are within uncertainty of calculated fission spectrum averaged cross sections based on recently re-evaluated chlorine nuclear data, which confirm recent impact studies performed for the Molten Chloride Reactor Experiment. Meanwhile, there currently exists only one published criticality benchmark experiment that is sufficiently sensitive to chlorine nuclear data. Discrepancies are found with this set of criticality safety benchmarks, which are more sensitive to thermal and epithermal neutron energies than the energies, above 100 keV, tested in this current work. Hence, there is still a need to re-evaluate the chlorine nuclear data at lower energies to assess these discrepancies. Interpretation of the data from future “faster” criticality benchmarks, which are needed for next-gen fast reactor designs, benefit from the improved constraints on the chlorine nuclear data validated in this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

A Coincident CdTe Detector Array for Enhanced Nuclear Process Monitoring

Nuclear fuel cycle aqueous separation processes desire improved real-time material characterization and process monitoring techniques; gamma coincidence spectroscopy has the potential to meet this need in these high throughput and high radiation environments based on its ability to reduce background noise, thereby enhancing detection limits and improving isotopic identification accuracy. A detector array composed of three CdTe detectors was designed to surround a chemical processing pipe in a reprocessing facility and evaluate the feasibility of passively assaying the nuclear materials flowing though this measurement point. This array uses commercial off the shelf components that are radiation hard and highly efficiency at low energies relevant to actinide photon signatures. Detector efficiency characterizations, coincidence detection, and potential configuration improvements are presented here.

Good, Erin C.