Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Daylighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

CloudSat Bias on Falling Snow Estimates Over the Daylight Only Operational Period (2012-2019)

Falling snow is a key component for the global atmospheric, hydrological and energy cycles, and its retrieval from space-based observations represents the best current capability to evaluate it globally. The Global Precipitation Measurement (GPM) Mission Core Observatory, launched in 2014, together with its constellation sensors, can provide quasi-global precipitation estimates every 30 minutes (for level 3 products). Evaluation and validation efforts for such products are crucial, and for global evaluations, one of the most suitable instruments is the Cloud Profiling Radar (CPR) on board CloudSat, which is sensitive to light rain and falling snow. However, due to a battery anomaly in 2011, during its period of overlapping observations with GPM the CPR has operated in a Daylight Only Operations mode (DO-Op) in which it makes measurements primarily during only the daylit portion of its orbit. The goal of this work is to estimate biases inherent in global snowfall amounts derived from CPR measurements due to this shift to DO-Op mode. We use CloudSat's snowfall measurements during its Full Operations (Full-Op) period from 2006 to 2010 to evaluate the impact DO-Op mode would have had during this period. Results indicate that omitting the nocturnal component of the diurnal cycle of snowfall has nonnegligible impact on snowfall amounts in some regions. The lack of nighttime data during DO-Op biases the latitudinally averaged mean snowfall rates as well as some regional values. Hemispheric differences in bias may be due to more pronounced diurnal variability in the northern hemisphere owing to more prevalent land surface versus the southern hemisphere. The results highlight the need to sample consistently with the CloudSat observations or to adjust snowfall estimates derived from CloudSat when using DO-Op data to evaluate other precipitation products.

Milani, Lisa↗

Biases in CloudSat Falling Snow Estimates Resulting from Daylight-Only Operations

Falling snow is a key component of the Earth’s water cycle, and space-based observations provide the best current capability to evaluate it globally. The Cloud Profiling Radar (CPR) on board CloudSat is sensitive to snowfall, and other satellite missions and climatological models have used snowfall properties measured by it for evaluating and comparing against their snowfall products. Since a battery anomaly in 2011, the CPR has operated in a Daylight-Only Operations (DO-Op) mode, in which it makes measurements primarily during only the daylit portion of its orbit. This work provides estimates of biases inherent in global snowfall amounts derived from CPR measurements due to this shift to DO-Op mode. We use CloudSat’s snowfall measurements during its Full Operations (Full-Op) period prior to the battery anomaly to evaluate the impact of the DO-Op mode sampling. For multi-year global mean values, the snowfall fraction during DO-Op changes by −10.16% and the mean snowfall rate changes by −8.21% compared with Full-Op. These changes are driven by the changes in sampling in DO-Op and are very little influenced by changes in meteorology between the Full-Op and DO-Op periods. The results highlight the need to sample consistently with the CloudSat observations or to adjust snowfall estimates derived from CloudSat when using DO-Op data to evaluate other precipitation products.

Lisa Milani↗

Frame for daylight photocopying

Inexpensive fixture makes quick copy of picture or photograph, film positive or negative, without darkroom. Device holds four-by-five inch instant-developing Polaroid 58 or 55 (or equivalent) film.

Dalton, J. W.↗

Daylight spectra of individual lightning flashes in the 370-690 nm region

An optical multichannel analyzer slit spectrometer coupled to a minicomputer was used to record lightning spectra. This is the first successful application of a slit spectrometer to the study of individual lightning flashes and it was accomplished in the daytime. Over 300 spectra were obtained in 1978 and 1979 and are correlated with other experiments in the Thunderstorm Research International Program (TRIP). The spectra duplicate previously published nighttime data but reveal for the first time the relative intensity of H-alpha (656.3 nm) and H-beta (486.1 nm) emissions above their daytime absorption features. These are the characteristic Fraunhofer C and F lines in the solar spectrum. This result suggests that the observation of lightning from space may be accomplished by monitoring the hydrogen emissions from lightning which occur on earth, or on other planets with hydrogen in their atmospheres, such as Jupiter and Venus where lightning recently has been reported.

Orville, R. E.↗

Daylight imagery of ocean surface waves for wave spectra

A simple second-order model is developed to describe the transformation between surface wave slope and radiance incident on an optical sensor. The model includes azimuth as well as elevation variations in the sky-radiance distribution and their effects on the imaging of wave slopes approaching the sensor azimuth from various directions. The model also includes upwelling radiance. Comparison between the exact transformation from wave slope to radiance and the second-order model suggests that they yield quantitatively similar results. The model is used in physical interpretations of how wave slopes are imaged and in indicating a way of optimizing the linearity and contrast of the transfer function relating wave slope to radiance for various sensor geometries, thereby minimizing sources of error. One-dimensional numerical simulations of the imaging of an analytically generated wave-slope profile demonstrate the utility of this technique in obtaining slope spectra.

Monaldo, F. M.↗

Feasibility Study of Utilizing Existing Infrared Array Cameras for Daylight Star Tracking on NASA's Ultra Long Duration Balloon (ULDB) Missions

The purpose of this study was to investigate the feasibility of developing a daytime star tracker for ULDB flights using a commercially available off-the-shelf infrared array camera. This report describes the system used for ground-based tests, the observations, the test results, and gives recommendations for continued development.

Tueller, Jack↗

SORCE Daylight-Only Operations

The recent experience of the SORCE flight operations team offers an excellent example of innovative engineering using limited resources. The goal of this paper is to extend to the space operations community the lessons learned during this critical redesign in order to aid other missions facing equally daunting challenges. The end result is a mission extended well beyond its designed life continuing to return important data to the science community to extend the climate record.

Spacecraft Anomaly Recovery↗

lumicap v0.1

Automated HDR luminance imaging system designed for daylighting research and building science. It controls a fisheye-lens camera to capture time-lapse bracket sequences, merges them into calibrated HDR images, and runs a full post-processing pipeline — all unattended. Features: - Scheduled LDR bracket capture via gphoto2 - HDR merging with vignetting, ND filter, and fisheye projection corrections - Illuminance and luminance meter integration (Konica Minolta T-10A, LS-100/150) - Daylight glare probability (DGP) and solar position computation - Automated false-color rendering, JPEG thumbnails, and daily time-lapse video - CSV data logging per timestep Uses: - Long-term monitoring of daylight conditions in buildings - Glare analysis for occupant comfort research - Solar irradiance and sky luminance studies Advantages: - End-to-end automation — capture, calibration, analysis, and archiving run without manual intervention - Built on the proven Radiance toolchain, ensuring photometrically accurate HDR output - Hardware-agnostic meter support via serial auto-detection - Lightweight — no GUI overhead, deployable on a headless Raspberry Pi or similar embedded system

Wang, Taoning [Lawrence Berkeley National Laborato↗

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determining critical points to control electric lighting to meet circadian lighting requirements and minimize energy use

Designing electric lighting systems to meet circadian lighting requirements may raise light levels and consequently energy use compared to existing practices. To reduce energy use, electric lighting can be controlled to be dimmed or turned off when sufficient daylight levels are available in space. This requires input from one or a few critical measurement points. However, it is unclear how critical points can be determined to ensure that all occupants receive the needed light levels while reducing electric lighting energy. This paper discusses three approaches for selecting critical points and utilizes annual daylight simulations modified to account for sky spectra, and coupled with spectral electric lighting simulations. Among the three evaluated approaches, the use of continuous daylight autonomy (modified to use EML measured at eye positions) is helpful for estimating electric lighting energy for dimmable electric lighting systems, and for identifying energy-saving strategies.

Abboushi, Belal K.↗

The Impact of Operated Window Shading on Visual Comfort, Non-Visual Health, and Energy Demand from Electric Lighting

This paper introduces a simulation-based workflow to assess annual circadian lighting performance, glare risk and energy demand for an array of seated view positions under operated shading and electric lighting conditions. This workflow uses a combination of 9-band and 81-band simulations to represent daylight and electric lighting respectively. Annual daylight-driven calculations rely on a python-based code provided in the LARK simulation engine which was used to run 180-degree high dynamic range (HDR) renderings with 9-bands of spectral resolution. The results reveal the impact of shading systems on equivalent melanopic lux (EML) and daylight glare probability (DGP) over time and the energy demand (kWh) from electric lighting systems to supplement eye-level recommendations from the WELL v2 Building Standard.

Rockcastle, Siobhan↗

The Effects of Primary Light Sources on Worker Performance and Alertness

Traditional office buildings use a variety of primary light sources (e.g., LED/fluorescent lights). As interest in LEED certified office buildings increase and research has shown that enhanced lighting design improves human performance and alertness (Viola et al., 2008; Juslén & Tenner, 2005; Edwards & Torcellini, 2002), more office buildings are incorporating a daylighting design. We investigated the differences between employee performance and alertness in two different building types (daylight vs. artificial light). We hypothesized that employee performance and sleep duration would be improved in a building designed to increase exposure to natural daylight compared to traditional office settings.

cognitive performance↗

Field validation of data-driven BSDF and peak extraction models for light-scattering fabric shades

Shading and daylighting systems affect cooling, heating, and lighting energy use by modulating solar radiation through the building façade. Characterizing shading systems holistically and accurately helps designers and engineers evaluate shading systems to achieve energy and non-energy performance goals. These complex fenestration systems can be modeled using Bidirectional Scattering Distribution Functions (BSDF), which map incident radiation to hemispherical distributions of outgoing radiation. Data-driven, tabulated BSDFs are derived from interpolated goniophotometer measured data, then sampled during the raytracing calculation. A peak extraction (PE) algorithm was developed to circumvent limits in BSDF angular resolution, where the specular peak is extracted during simulation by evaluating the BSDF in the through direction and surrounding region. The objective of this study was to validate this measurement and modeling workflow using field monitored data from a full scale testbed with eleven installed fabrics of different weaves, openness factors, and colors and assess the accuracy of the workflow under different adaptation and contrast conditions. Test conditions were limited to clear sky conditions with the sun in the field of view. Results showed that, for tensor tree datasets, vertical illuminance, solar luminance (2.5° apex), and daylight glare probability (DGP) were predicted to within a mean bias error (MBE) error of -456 lx (-12.3%), -3.46e5 (-38.4%), and -0.042 (-7.8%) when full PE occurred. With a binary classification of glare/ no glare, DGP was predicted accurately with a true positive rate of 0.98 and true negative rate of 1.0 using tensor tree data and less accurately with Klems BSDF data, particularly for cases of no glare. The workflow may be of insufficient accuracy to distinguish borderline performance between fabrics using the four-point glare scale, particularly under low adaptation, high contrast daylit conditions. Errors were due to reductions in peak shape and intensity across the BSDF interpolation and data reduction workflow. Future work is needed to better preserve measurement fidelity during interpolation and sampling, which in turn will improve PE performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multidisciplinary concurrent optimization framework for multi-phase building design process

Modern day building design projects require multidisciplinary expertise from architects and engineers across various phases of the design (conceptual, preliminary, and detailed) and construction processes. The Architecture Engineering and Construction (AEC) community has recently shifted gears toward leveraging design optimization techniques to make well-informed decisions in the design of buildings. However, most of the building design optimization efforts are either multidisciplinary optimization confined to just a specific design phase (conceptual/preliminary/detailed) or single disciplinary optimization (structural/thermal/daylighting/energy) spanning across multiple phases. Complexity in changing the optimization setup as the design progresses through subsequent phases, interoperability issues between modeling and physics-based analysis tools used at later stages, and the lack of an appropriate level of design detail to get meaningful results from these sophisticated analysis tools are few challenges that limit multi-phase multidisciplinary design optimization (MDO) in the AEC field. Here this paper proposes a computational building design platform leveraging concurrent engineering techniques such as interactive problem structuring, simulation-based optimization using meta models for energy and daylighting (machine learning based) and tradespace visualization. The proposed multi-phase concurrent MDO framework is demonstrated by using it to design and optimize a sample office building for energy and daylighting objectives across multiple phases. Furthermore, limitations of the proposed framework and future avenues of research are listed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Acclimation to high and low diurnal light is flexible in Chlamydomonas reinhardtii

Chlamydomonas acclimates to repeated low (LL) or high light (HL) days by changing the abundance of photosynthetic complexes and the ultrastructure of its thylakoid membranes. These phenotypes persist through the night phases, suggesting a readiness for the daylight environment that is routinely experienced despite the intervening dark periods [S. Dupuis et al., Plant Cell 37, koaf086 (2025), 10.1093/plcell/koaf086]. Here, we investigate how prior acclimation impacts algal fitness upon a change in daylight intensity and how quickly Chlamydomonas can reprogram its photoprotective strategy in a diurnal context. We performed a systems analysis of synchronized populations acclimated to diurnal LL when subjected to HL days and of populations acclimated to diurnal HL when subjected to LL days. In the latter case, diurnal photoacclimation decreased fitness during the first day at a new light intensity: HL-acclimated cells barely increased in size over the first LL period, and they failed to complete a cell cycle. However, although LL-acclimated cells showed severe photodamage after 6 h of HL, they recovered chloroplast form and function later that afternoon and successfully divided at nightfall. These cells rapidly altered their thylakoid membrane ultrastructure, increased their photoprotective quenching capacity, and decreased their inventory of photosystem and antenna proteins by the end of the first HL day. Transcriptomic and proteomic analyses revealed rapid induction of thousands of genes, including those encoding proteases, chaperones, and other proteins involved in the chloroplast unfolded protein response. These results show that the alga is highly flexible and competent to rapidly acclimate to changes in diurnal light intensity.

Diel↗

Relative Contributions of sc-DER, mel-DER, Color Rendition, Chromaticity, and Illuminance to Spatial Brightness Perception

An experiment was conducted to examine spectrally based factors that contribute to the visual perception of interior environments, with a focus on brightness perception. Thirty-two participants evaluated 60 different lighting scenes in a mock office. The lighting spectral power distributions varied systematically in illuminance, chromaticity (CCT and Duv), s cone opic daylight efficacy ratio (sc-DER), melanopic daylight efficacy ratio (mel-DER), and color rendition (R f , R g , and R cs,h1 ). At the operationalized levels of these variables, illuminance had the largest effect on brightness perception. Notably, the second largest effect was due to changes in red chroma (R cs,h1 ). The effect of sc-DER was also statistically significant but was a tertiary effect. The effects of mel-DER, CCT, and Duv were not statistically significant. This large effect of red chroma is consistent with the existing understanding that changes in color perception are often perceived when illuminance changes. In conclusion, with appropriate changes in color rendition and other factors held constant, spatial brightness perception was preserved through a decrease from 500 lux to 250 lux.

42 ENGINEERING↗