SEARCH · Engineering Papers
Results for “Data Center”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Scalable Data Center Capacity for DOE's AI Prototype: A Rapidly Available Gigawatt Data Center for DOE
The multilaboratory Gigawatt Data Center working group was commissioned to identify approaches to rapidly establish federal data centers with scalable capacities up to 1,000 MW. These state-of-the-art facilities will serve as hubs for interdisciplinary collaboration, industry partnerships, and transformative applications of artificial intelligence. The proposed strategic shift includes facilitating multilaboratory collaboration, prioritizing operational efficiency, expanding public–private partnerships, optimizing investments, ensuring long-term contractual flexibility, supporting open science and secure data enclaves, and exploiting high-speed national networks. Owing to their extensive experience and best practices, the US Department of Energy national laboratories are uniquely positioned to lead this initiative. We recommend conducting a feasibility analysis to rapidly identify the optimal sites for this initiative, and the effort will likely involve private industry for design, construction, financing, and operational integration. We also propose establishing multiple geographically diverse sites to ensure energy resilience, high operational reliability, and a diverse user base, thereby effectively addressing the nation’s critical needs.
Geospatial characterization of low-temperature heating and cooling demand in residential, commercial, manufacturing, agricultural, and data center sectors for potential geothermal applications in the United States
Thermal demand for heating and cooling has been predominantly supplied by fossil fuel combustion in the United States, although low-carbon alternatives are extensively available including geothermal, solar thermal, and waste heat. Here, this study analyzed end-use energy consumption, fuel expenditure, and data center commissioned power data to geospatially characterize the U.S. low-temperature heating and cooling demand at the county level in residential, commercial, manufacturing, agricultural, and data center sectors and understand potential opportunities for geothermal applications. In the analysis, the regional-scale energy consumption data was incorporated with system efficiencies to address actual demand and was then disaggregated with weighting factors to the county level. The results indicated that total low-temperature heating and cooling demand is 16.7 EJ, combining heating demand of 10.8 EJ and cooling demand of 5.9 EJ. Overall, 59.9 % (10 EJ) of the low-temperature heating and cooling demand occurred in the residential sector. The heating and cooling demand visualized in maps represented that the geospatial distribution of heating and cooling demand in the residential and commercial sectors is governed by the number of housing units and climate zone designations, while heating and cooling demand in the manufacturing, agricultural, and data center sectors is dependent on the number and location of facilities. The results also demonstrated that geothermal heat pumps are broadly used in the residential and commercial sectors for heating and cooling in the U.S. Midwest, South, and Northeast regions but are limited in the West, implying great decarbonization potential in the future.
RSF Data Center Tour
The Data Center in the Research Support Facility on the campus of the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) marks a significant accomplishment in its ultra-efficiency. Data centers by nature are very energy intensive. The RSF Data Center was designed to use 80% less energy than NREL's old data center, which had been in use for the last 30 years. This tour takes you through the data center highlighting its energy saving techniques.
Liquid cooled data center design selection
Input data, specifying aspects of a thermal design of a liquid cooled data center, is obtained. The input data includes data indicative of ambient outdoor temperature for a location of the data center; and/or data representing workload power dissipation for the data center. The input data is evaluated to obtain performance of the data center thermal design. The performance includes cooling energy usage; and/or one pertinent temperature associated with the data center. The performance of the data center thermal design is output.
Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers
Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.
Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers
Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.
Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers
Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.
Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers
Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.
TSDC: Transportation Secure Data Center: Real-World Data for Planning, Modeling, and Analysis
The Transportation Secure Data Center is a centralized repository for high-resolution transportation data from hundreds of travel and transit surveys and studies. It makes vital transportation data broadly available to users while preserving the privacy of survey participants. It houses surveys and studies conducted by state departments of transportation, metropolitan planning organizations, transit agencies, cities, and other public agencies. Meanwhile, the Livewire Data Platform empowers research, industry, and academic partners to easily and securely preserve, maintain, share, discover, and gain access to transportation and mobility data. Livewire accommodates a range of datasets, including behavioral, experimental, model, analytical, and raw data at the vehicle, traveler, and system levels. Datasets support mobility research and planning spanning urban science, connected and automated vehicles, fueling and charging infrastructure, mobility decision science, multimodal transportation, vehicle efficiency, and more.
Transportation Secure Data Center: Real-World Data for Planning, Modeling, and Analysis
The Transportation Secure Data Center (TSDC) provides free, web-based access to detailed transportation data from a variety of travel surveys conducted across the nation. While preserving the privacy of survey participants, this online repository makes vital transportation data broadly available to users from the comfort of their own desks via a secure online connection. Maintained by the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) in partnership with the U.S. Department of Transportation (DOT), the TSDC houses data from travel surveys and studies conducted using global positioning system (GPS) devices. It features millions of data points - second-by-second GPS readings, vehicle characteristics (if applicable), and demographics - for all modes of travel. NREL screens the initial data for quality control, translates each data set into a consistent format, and interprets the data for spatial analysis. NREL's processing routines add information on vehicle fuel economy and road grades and join data points to the road network.
The environmental footprint of data centers in the United States
Much of the world's data are stored, managed, and distributed by data centers. Data centers require a tremendous amount of energy to operate, accounting for around 1.8% of electricity use in the United States. Large amounts of water are also required to operate data centers, both directly for liquid cooling and indirectly to produce electricity. For the first time, we calculate spatially-detailed carbon and water footprints of data centers operating within the United States, which is home to around one-quarter of all data center servers globally. Our bottom-up approach reveals one-fifth of data center servers direct water footprint comes from moderately to highly water stressed watersheds, while nearly half of servers are fully or partially powered by power plants located within water stressed regions. Approximately 0.5% of total US greenhouse gas emissions are attributed to data centers. We investigate tradeoffs and synergies between data center's water and energy utilization by strategically locating data centers in areas of the country that will minimize one or more environmental footprints. Our study quantifies the environmental implications behind our data creation and storage and shows a path to decrease the environmental footprint of our increasing digital footprint.
IM3 Projected US Data Center Locations
IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830
IM3 Projected US Data Center Locations
IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830
Transportation Secure Data Center: Real-world Data for Planning, Modeling, and Analysis (Fact Sheet)
The Transportation Secure Data Center (TSDC) at www.nrel.gov/tsdc provides free, web-based access to detailed transportation data from a variety of travel surveys conducted across the nation. While preserving the privacy of survey participants, this online repository makes vital transportation data broadly available to users from the comfort of their own desks via a secure online connection.
Demand Response and Open Automated Demand Response Opportunities for Data Centers
This study examines data center characteristics, loads, control systems, and technologies to identify demand response (DR) and automated DR (Open Auto-DR) opportunities and challenges. The study was performed in collaboration with technology experts, industrial partners, and data center facility managers and existing research on commercial and industrial DR was collected and analyzed. The results suggest that data centers, with significant and rapidly growing energy use, have significant DR potential. Because data centers are highly automated, they are excellent candidates for Open Auto-DR. 'Non-mission-critical' data centers are the most likely candidates for early adoption of DR. Data center site infrastructure DR strategies have been well studied for other commercial buildings; however, DR strategies for information technology (IT) infrastructure have not been studied extensively. The largest opportunity for DR or load reduction in data centers is in the use of virtualization to reduce IT equipment energy use, which correspondingly reduces facility cooling loads. DR strategies could also be deployed for data center lighting, and heating, ventilation, and air conditioning. Additional studies and demonstrations are needed to quantify benefits to data centers of participating in DR and to address concerns about DR's possible impact on data center performance or quality of service and equipment life span.
IM3 Open Source Data Center Atlas
IM3 Open Source Data Center Atlas Description This dataset contains locations of existing data center facilities in the United States. Data center locations were derived from OpenStreetMap (OSM), a crowd-sourced database. Data points from OSM are processed in various ways to determine additional variables provided in the data including: facility area (square feet), associated US county, and US state. This dataset can be used to identify areas of concentrated data center development and inform government and private sector planning strategies for future buildout of data centers and the infrastructure necessary to support it. Usage Notes Validation of OSM-derived data center locations is an ongoing development under the IM3 project, and the database will be updated as new information becomes available. In some instances, both the data center area (e.g., campus) and individual data center buildings are included as overlapping areas in the database. Both values are retained. Data center points, buildings, and campus areas are provided as separate layers in the downloadable data package. Note that data items are not necessarily complete across layers. That is, a specific data center may only be present as a single point geometry in the "point" layer while other data centers are represented in both the campus and building layers. In some cases, data center campuses and/or buildings straddle a county boundary line. Mappings to both counties are retained in the database as separate rows. These data rows will have the same data center id information, but each will have different county information. Crowd-sourced data, by nature, relies on individuals and communities to provide information. As a result, some data may be missing where it has not yet been reported. As we collect information on additional data center locations and as OSM receives additional contributions, the database will be updated to capture additional data points not yet shown. Data items will occasionally be removed from OSM if they are misidentified, if they no longer exist, if they are duplicates of another item, or similar. For that reason, updated versions of this database may not contain all data center locations included in previous versions. Technical Information Data is available for download under the following formats: GeoPackage (GPKG) CSV Geospatial data is provided in the WGS84 (EPSG:4326) coordinate reference system. The GeoPackage download contains the following layers. See usage notes for more information. "point" "building" "campus" The "point" layer includes all data from OSM that had POINT geometry type (i.e., individual coordinates). The "building" layer includes all OSM data that did not have POINT geometry and where the building tag in the OSM export was neither equal to "no" or null. Data that did not meet the "point" or "building" qualification was assumed to be a facility campus and included in the "campus" layer. The dataset contains the following parameters. Variables provided by OSM are labeled with (OSM-provided). id - unique identification number (OSM-provided with prefix of "node/", "relation/" and similar attributes removed) state - name of US state state_abb - two letter US state abbreviation state_id - state ID number county - name of US county county_id - county ID number ref - reference numbers or codes (OSM-provided) operator - the name of the company, corporation, or person in charge facility (OSM-provided) name - name of facility (OSM-provided) sqft - surface area of facility polygon, measured in square feet. Only available for "building" and "campus" layers lat - latitude of data centroid point lon - longitude of data centroid point type – represented spatial information. One of "point", "building", or "campus". geometry – POLYGON geometry of area footprint (in "campus" and "building" layers) or POINT geometry of locations (in "point" layer). This parameter is not included in the csv download. Attribution Data center locations were derived from OpenStreetMap, which is made available at openstreetmap.org under the Open Database License (ODbL). US state and county boundary information was collected from the US Census Bureau for the year 2024, which is made publicly available at https://www.census.gov/geographies/mapping-files.html Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License The IM3 Open Source Data Center Atlas is made available under the Open Database License: http://opendatacommons.org/licenses/odbl/1.0/. Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830
IM3 Open Source Data Center Atlas
IM3 Open Source Data Center Atlas Description This dataset contains locations of existing data center facilities in the United States. Data center locations were derived from OpenStreetMap (OSM), a crowd-sourced database. Data points from OSM are processed in various ways to determine additional variables provided in the data including: facility area (square feet), associated US county, and US state. This dataset can be used to identify areas of concentrated data center development and inform government and private sector planning strategies for future buildout of data centers and the infrastructure necessary to support it. Usage Notes Validation of OSM-derived data center locations is an ongoing development under the IM3 project, and the database will be updated as new information becomes available. In some instances, both the data center area (e.g., campus) and individual data center buildings are included as overlapping areas in the database. Both values are retained. Data center points, buildings, and campus areas are provided as separate layers in the downloadable data package. Note that data items are not necessarily complete across layers. That is, a specific data center may only be present as a single point geometry in the "point" layer while other data centers are represented in both the campus and building layers. In some cases, data center campuses and/or buildings straddle a county boundary line. Mappings to both counties are retained in the database as separate rows. These data rows will have the same data center id information, but each will have different county information. Crowd-sourced data, by nature, relies on individuals and communities to provide information. As a result, some data may be missing where it has not yet been reported. As we collect information on additional data center locations and as OSM receives additional contributions, the database will be updated to capture additional data points not yet shown. Technical Information Data is available for download under the following formats: GeoPackage (GPKG) CSV Geospatial data is provided in the WGS84 (EPSG:4326) coordinate reference system. The GeoPackage download contains the following layers. See usage notes for more information. "point" "building" "campus" The "point" layer includes all data from OSM that had POINT geometry type (i.e., individual coordinates). The "building" layer includes all OSM data that did not have POINT geometry and where the building tag in the OSM export was neither equal to "no" or null. Data that did not meet the "point" or "building" qualification was assumed to be a facility campus and included in the "campus" layer. The dataset contains the following parameters. Variables provided by OSM are labeled with (OSM-provided). id - unique identification number (OSM-provided with prefix of "node/", "relation/" and similar attributes removed) state - name of US state state_abb - two letter US state abbreviation state_id - state ID number county - name of US county county_id - county ID number ref - reference numbers or codes (OSM-provided) operator - the name of the company, corporation, or person in charge facility (OSM-provided) name - name of facility (OSM-provided) sqft - surface area of facility polygon, measured in square feet. Only available for "building" and "campus" layers lat - latitude of data centroid point lon - longitude of data centroid point type – represented spatial information. One of "point", "building", or "campus". geometry – POLYGON geometry of area footprint (in "campus" and "building" layers) or POINT geometry of locations (in "point" layer). This parameter is not included in the csv download. Attribution Data center locations were derived from OpenStreetMap, which is made available at openstreetmap.org under the Open Database License (ODbL). US state and county boundary information was collected from the US Census Bureau for the year 2024, which is made publicly available at https://www.census.gov/geographies/mapping-files.html Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License The IM3 Open Source Data Center Atlas is made available under the Open Database License: http://opendatacommons.org/licenses/odbl/1.0/. Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830