Effect of Evaporation on Vapor Space Flammability in DWPF Process Vessels - 20278

The Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) processes liquid high-level waste (HLW) and encapsulates it in glass within stainless-steel containers suitable for safe, long-term storage and disposal. Radiolytic and chemical decomposition of the liquid waste generates hydrogen and other flammable gases creating a hazard. The rate of flammable gas generation increases by an order of magnitude as temperature increases from sub-boiling to boiling. DWPF controls this hazard in process tanks by ensuring a minimum purge flow through each tank's head space. The minimum purge flow rate is established assuming dry air and neglecting evaporation. However, this study determined that steam from boiling in a representative process tank is sufficient to dilute flammable gases and, thereby, preclude flammability. For sub-boiling, water vapor is an insufficient diluent considering hydrogen's lower flammable limit (LFL) in air. However, the upper and lower flammable limits approach each other in a hydrogen-air-water-vapor environment as the water vapor concentration increases. This effect may preclude flammable conditions if water vapor concentration is about 60 volume percent or higher. A saturated, constant-pressure air-water system would achieve 60 volume percent water vapor at 86 deg. C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the sludge batch 9 (Macrobatch 10) DWPF pour stream glass sample

A pour stream (PS) sample taken during processing of Sludge Batch 8 (SB8, Macrobatch 10) was analyzed by Savannah River National Laboratory (SRNL) to verify compliance with the Defense Waste Processing Facility (DWPF) Glass Product Control Program. The following conclusions were drawn from these analyses; The sum of oxides for the SB8 PS glass (97.41 wt%) is within the Product Composition Control System (PCCS) limits (100 ± 5 wt%); The average Waste Dilution Factor (WDF) calculated from the Tank 40 dried sludge analysis results for SB8 is 1.9 ± 0.1. In general, the radionuclide concentration of the SB8 PS glass sample calculated using this WDF is in good agreement with the measured radionuclide content; The Product Consistency Test (PCT) results indicate that the SB8 PS glass meets the Waste Acceptance Product Specifications (WAPS) for durability, with normalized release rates for boron, lithium and sodium all at least two standard deviations lower than those of the Environmental Assessment (EA) glass; The average measured density of the SB8 PS glass is 2.72 g/cm 3 , consistent with previous PS samples; and, The average measured Fe 2+ /ΣFe ratio of the SB8 PS glass is 0.15, within the target range of 0.09- 0.33, and closely resembling the predicted REDOX value of 0.15.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Permanganate Oxidation of Defense Waste Processing Facility (DWPF) Recycle Collection Tank (RCT) Simulants Larger Scale Protocol Runs - Chemical Process Cell (CPC) Nominal and Foamover Conditions

Testing to develop a process to oxidize glycolate and other organic species in non-radioactive waste simulants was requested by Savannah River Remediation (SRR). A Task Technical and Quality Assurance Plan (TTQAP) was written to describe the testing requested by SRR in the development of a process to oxidize glycolate and other organic species that are responsible for hydrogen generation from thermolysis. Scoping studies have been completed as requested by a Technical Assistance Request (TAR) to evaluate the feasibility of using sodium permanganate and Fenton's Reagent (iron catalyzed hydrogen peroxide) for destroying glycolate. The results from these scoping studies were summarized in a report. Six phases of tests with simulants have been planned in developing an oxidation flowsheet for the Recycle Collection Tank (RCT), as shown in Table 1. The first three phases have been completed. The first phase comprised of scoping tests of permanganate and Fenton's reagent. The second phase was a matrix of 23 tests completed to inform a down-select decision by SRR and to complete testing needed to understand the influence of various factors in defining the optimum processing conditions for oxidation of organics. From the results of this testing, oxidation by permanganate was chosen over Fenton's reagent with hydrogen peroxide. The third phase of testing was to demonstrate nominal operation of the permanganate oxidation process under protocols similar to those used in the Defense Waste Processing Facility (DWPF).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the Sludge Batch 7b (Macrobatch 9) DWPF Pour Stream Glass Sample

The Defense Waste Processing Facility (DWPF) began processing Sludge Batch 7b (SB7b), also referred to as Macrobatch 9 (MB9), in January 2012. SB7b is a blend of the heel of Tank 40 from Sludge Batch 7a (SB7a) and the SB7b material that was transferred to Tank 40 from Tank 51. SB7b was processed using Frit 418.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of Permanganate Oxidation of Glycolate on Corrosion of the Defense Waste Processing Facility (DWPF) Recycle Collection Tank (RCT), Transfer-line and Waste Tank Materials of Construction (MoC)

Savannah River Remediation (SRR) is evaluating the use of glycolic acid to replace formic acid as an alternate reductant for the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS). The replacement is aimed at reducing facility hazards, improving pH stability and rheological control, and lowering off gas production. Glycolate, which is the product that may remain, can also be carried downstream to High-Level Waste and Low-Level Waste facilities. Complete oxidation of glycolate and other organic species from the Sludge Receipt and Adjustment Tank (SRAT) may be necessary to minimize thermolytic hydrogen generation that can cause flammability issues. The glycolate oxidation may be performed in the Recycle Collection Tank (RCT). The RCT heel would be adjusted with sodium hydroxide to maintain the solution caustic and sodium nitrite as corrosion inhibitor prior to the addition of condensate that can be from the contents of the Slurry Mix Evaporator Condensate Tank (SMECT) or Offgas Condensate Tank (OGCT). The RCT tank collects the waste to be transferred via the Low Point Pump Pit – Recycle Pump Tank (LPPP-RPT) through a jacketed transfer-line to the Tank Farm facility. Scoping studies were performed to evaluate an oxidizing agent and sodium permanganate was selected as the best option for glycolate destruction. Testing was recommended to determine the impact on the Materials of Construction (MoC) due to the addition of sodium permanganate. The targeted concentration of sodium permanganate used equated to a 7:1 molar permanganate to glycolate ratio (nominally 0.002 M permanganate). However, to conservatively maximize the permanganate corrosivity, in some cases no glycolate was added.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Permanganate Oxidation of Actual Defense Waste Processing Facility (DWPF) Slurry Mix Evaporator Condensate Tank (SMECT) and Offgas Condensate Tank (OGCT) Samples to Remediate Glycolate

Savannah River Remediation (SRR) tasked Savannah River National Laboratory (SRNL) to examine glycolate destruction in radioactive samples emulating the proposed process. Experiments with radioactive Defense Waste Processing Facility (DWPF) condensates were performed to demonstrate the oxidation of glycolate using sodium permanganate. One test each was performed for Off-Gas Condensate Tank (OGCT) and Slurry Mix Evaporator Condensate Tank (SMECT) samples received. Condensates were blended with Recycle Collection Tank (RCT) heel simulant and Slurry Mix Evaporator (SME) product containing glycolate to represent typical RCT compositions with estimated nominal entrainment of glycolate. A permanganate to glycolate (P/G) molar ratio targeting 5.7 decreased sample glycolate concentration below Ion Chromatography (IC), glycolate method reporting limits in less than 2 hours for the OGCT sample and in less than 8 hours for the SMECT sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling the Destruction of Glycolate in the Defense Waste Processing Facility (DWPF) Recycle Stream and Concentration Factors for Glycolate in the 2H Evaporator

Two models were developed to predict maximum glycolate concentrations in the Savannah River Site (SRS) Concentration, Storage, and Transfer Facility (CSTF) from implementation of the Nitric-Glycolic flowsheet at the Defense Waste Processing Facility (DWPF). One model describes the kinetics of glycolate destruction via chemical oxidation with sodium permanganate. This model conservatively predicts glycolate concentration delivered to the CSTF with a high probability the actual glycolate concentration is lower than predicted. The second model describes the potential concentration of said residual glycolate within the 242-16H (i.e., “2H”) Evaporator system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling of Chemical Slurry Rheology in DWPF Sludge Batch (SB) 10 Simulants

The Defense Waste Processing Facility (DWPF) treats high-activity radionuclides from sludge through a process called vitrification. This process converts radioactive liquid waste currently stored in tank farms into a solid glass form that is suitable for long-term storage and disposal. Due to the complexities involved in vitrifying this waste within each operation of the Chemical Processing Cell (CPC), waste rheology is studied to characterize the fluid-mechanical properties as it passes through the CPC and into the Melter. To better understand the waste and validate flow behavior, slurry rheology of simulants that represents the waste was studied at various acid stoichiometry percentages and solids concentrations to determine the simulant’s yield stress and viscosity. This research work has been supported by the DOE-FIU Science & Technology Workforce Development Initiative, an innovative program developed by the U.S. Department of Energy’s Office of Environmental Management (DOE-EM) and Florida International University’s Applied Research Center (FIU-ARC). During the spring of 2022, a DOE Fellow intern, Brendon Cintas, spent 10 weeks doing a summer internship at Savannah River National Laboratory (SRS) under the supervision and guidance of Dan Lambert, Chemical Flowsheet Development. The intern’s project was initiated on June 6, 2022, and continued through August 11, 2022 with the objective of assisting scientists at SRNL’s Rheology and Grout Laboratory at Aiken Country Technology Lab (ACTL) better understand the sludge composition on the rheology of a simulant slurry using a HAAKE RheoStress 6000 rheometer and extrapolate the results to the real-waste data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Defense Waste Processing Facility (DWPF) Condensate Samples and Evaluation of the Glycolate Destruction Process during Nitric-Glycolic flowsheet Transition

Glycolate concentrations were measured by the Savannah River National Laboratory (SRNL) in Slurry Mix Evaporator Condensate Tank (SMECT) and Recycle Collection Tank (RCT) samples retrieved after implementation of the Nitric-Glycolic Acid flowsheet at the Defense Waste Processing Facility (DWPF). No glycolate has been detected in any sample using Ion Chromatography (IC) with a detection limit of 8 mg/L, and no glycolate has been detected using either IC or Proton Nuclear Magnetic Resonance Spectroscopy ( 1 HNMR) after a permanganate strike was performed in the RCT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the Sludge Batch 9 (Macrobatch 11) DWPF Pour Stream Glass Sample

A pour stream (PS) sample taken near the end of processing of Sludge Batch 9 (SB9, Macrobatch 11) with the Nitric-Formic Acid Flowsheet was analyzed by the Savannah River National Laboratory to comply with the Defense Waste Processing Facility (DWPF) Glass Product Control Program. The SB9 PS sample was taken on 5/28/2022 during Melter Feed Batch 815 associated with glass canister S04741, and was transferred to SRNL in Primary Container PC0136.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving Elemental Mercury Recovery in DWPF by pH and Ionic Strength Studies Using Laboratory Scale Replica – 26141

In order to safely disposition nuclear material at large scales, the Savannah River Site (SRS) constructed the Salt Waste Processing Facility (SWPF) for the removal of actinides, the Saltstone facility for preparation of a low-level cementitious grout, and the Defense Waste Processing Facility (DWPF) for the vitrification of high-level waste (HLW). A few years after processing began, high concentrations of mercury were discovered in cementitious waste at the Saltstone facility which initiated a search for the source of mercury during processing at these SRS facilities. Mercury serves as a catalyst in the dissolution of spent nuclear fuel, aluminum-actinide alloys, for actinide recovery, but not enough is known about the behavior and properties of mercury within these process streams.

Pina, Jeanette [Savannah River National Laboratory↗

Analysis of the Sludge Batch 9 (Macrobatch 11) DWPF Pour Stream Glass Sample Collected During the Nitric-Glycolic Acid Flowsheet Transition

A pour stream (PS) sample taken near the end of processing of Sludge Batch 9 (SB9, Macrobatch 11) during the transition to the nitric-glycolic acid (NGA) flowsheet was analyzed by the Savannah River National Laboratory (SRNL). The SB9 NGA PS sample was taken on 12/18/2022 during Melter Feed Batch 823 associated with glass canister S04773 and was transferred to SRNL in Primary Container PC0139 in February 2023.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluations of the Fates of Alkali Metals, Actinides, Mercury, and Iodine During DWPF Recycle Diversion

The fates of alkali metals, actinides, mercury, and iodine in the Defense Waste Processing Facility Recycle Diversion process (as currently conceptualized) have been evaluated through paper studies based on available knowledge of the chemistry, physical properties, solubility, and volatility of the various species involved. The effect of pH in the range from 9 to 13 has been discussed. Recommendations for additional studies to close technology gaps have been provided, many of which are contingent upon the results of pending testing and sample characterization efforts. There is uncertainty in the amounts of soluble actinides passing through the process filter, though the bulk of the actinides should be captured on the filter with the Recycle Collection Tank solids and the total amounts of actinides should be relatively low. The Recycle Collection Tank pH could impact the fraction of actinides reaching the evaporator, but the primary factors determining the actinide fate are expected to be the amount of CO 2 sorption from air sparging or, for certain actinides (such as plutonium), oxidation and/or sorption to MnO 2 solids from permanganate additions to destroy the glycolate anion. Process optimization could minimize the amounts of actinides passing the filter. Depending upon the levels of mercury observed in recycle stream samples and because of the volatility of mercury, the evaporator should be designed with the capability to remove dense mercury phases from the condensate to avoid exceeding ETP WAC limits. The facility design must be adequate to transfer dense mercury phases and testing to confirm mercury transfer is needed. Simulant containing mercury is recommended for both filtration and evaporation testing. OLI Modeling of the various recycle streams is recommended to provide insight on the fate of iodine. Iodine-spiked simulants are recommended for upcoming evaporation tests. The pro) ect should consider the likelihood and impact of NAS scale formation in the evaporators. Process optimization may be needed to minimize the accumulation of NAS scale and possibly the sorption of actinides in the evaporator. Actual waste testing of the Recycle Diversion filtration and evaporation should include the analysis of actinides, mercury, and iodine to determine their partitioning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel Foaming Solutions for High Level Waste (HLW) Processing - 20195

Foaming occurs during treatment of high level waste (HLW) at Savannah River Site's Defense Waste Processing Facility (DWPF) in the Chemical Process Cell (CPC) due to high gas generation from process steam and chemical offgas products [1]. The presence of amphiphilic particles in the waste slurry stabilizes the foam [2], [3]. Efficient processing of HLW requires foam control, as foam-overs lead to lower productivity and potential radioactive contamination of condensate streams. DWPF currently employs Siovation Antifoam 747, a surfactant produced by Momentive Performance Materials, as an antifoaming agent during waste treatment. Despite its ability to control foam generation, processing issues have arisen from its use [4]. During DWPF chemical processing, a chemical antifoam agent must be effective at temperatures up to 103 deg. C between pH 3-13. Antifoam 747 is effective at pH 7 but degrades as pH deviates [5]. Antifoam 747 is 90% by weight Momentive{sup TM} L77 and 10% by weight Momentive{sup TM} Y-17580. These ingredients are trisiloxane products, which are especially vulnerable to attack in acidic and caustic environments. Since Antifoam 747 readily degrades, periodic addition is required. Several processing concerns related to Antifoam 747 have affected DWPF operation. Its overuse warranted concern of potential flammable melter offgas under upset conditions due to the generation of carbon dioxide and hydrogen. As a result, a Potential Inadequacy in the Safety Analysis (PISA) was declared [6]. Antifoam contribution has been included in the melter offgas flammability strategy and the quantity of antifoam is monitored to ensure limits are not exceeded. Testing at Savannah River National Laboratory (SRNL) determined that propanal, tri-methylsilanol, and hexamethyldisiloxane are generated as Antifoam 747 degrades, leading to a second PISA [7]. The formation of these byproducts poses additional flammability risks. Furthermore, the methyl and ethyl groups of these compounds may be responsible for the formation of the methyl and ethyl mercury discovered in DWPF [8], [9]. The formation of organomercury has specifically been called out by DOE as a need for increased research. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoam agents were evaluated as part of an effort to improve HLW treatment operations at DWPF and to reduce, or eliminate, the flammability hazards associated with Antifoam 747 currently in use. Foaming of high-level waste (HLW) slurries is an issue at the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) which is currently mitigated with a chemical antifoam agent. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoams were examined to improve HLW treatment at DWPF and to eliminate the flammability hazards associated with Siovation Antifoam 747 currently in use. Non-chemical foam control methods were deemed unviable for chemical processing at DWPF, as the spray/mist technique requires too much water and space limitations make installation and implementation of headspace agitators unfeasible. The use of ultrasonic energy thickened and further stabilized the foam. Two suitable alternative defoaming agents, Momentive{sup TM} Y- 17112 and Evonik Surfynol{sup R} MD-20, were identified. Both defoamers control foam over a pH range of 4- 13 at boiling, with no flammable degradation products, and only minimal quantities (100-200 mg/kg) are required under glycolic acid conditions. In order to validate the effectiveness of these defoaming agents, SRNL recommends irradiation testing and laboratory scale SRAT/SME experiments with actual radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Evaluation of Accelerated Basin De-Inventory Material Addition to Sludge Batch 11 (Rev. 1)

The Accelerated Basin De-inventory (ABD) program involves discarding spent nuclear fuel that is currently stored in L-Basin to the Defense Waste Processing Facility (DWPF) for vitrification. The first ABD discards will occur during the preparation of Sludge Batch (SB) 11. Savannah River Mission Completion has requested that the Savannah River National Laboratory assess the technical gaps related to the increased gadolinium poisoning requirement and the impacts of performing the Low Temperature Aluminum Dissolution (LTAD) process in Tank 51 with H-Canyon discards present. The following summarizes the evaluation of the impacts of increasing the quantity of gadolinium (and related topics) from what was previously evaluated in the SRNL studies of gadolinium-poisoned ABD material solubility, the overall ABD flowsheet review, and increasing the fissile mass loading in glass: 1) Based on literature surveys, there is no indication that organic interactions with gadolinium will be significant at the high pH (typically >13) conditions of the Concentration, Storage, and Transfer Facilities. Any interactions of gadolinium with organics in DWPF are not expected to adversely impact DWPF or downstream facilities. Thus, there is little-to-no residual risk from organic interactions with gadolinium [Gap closed]; 2) Adding depleted uranium to ABD material, targeting 235 U enrichment of 4.90% within each transfer window, will mitigate potential impacts from an increase in soluble 235 U enrichment during sludge washing and LTAD. The plan to take advantage of previous transfers and allow 235 U enrichment of >5% during the final transfer window carries a risk that Tank 51 supernate will have a 235 U enrichment of >5%, which should be evaluated for acceptance; 3) Increasing the gadolinium mass ratio to 3.0:1 Gd: 235 U(eq SLU ) should lead to the same or higher partitioning of gadolinium into the solid phase within the DWPF Chemical Process Cell, resulting in both liquid and solid phases with expected partitioning of Gd consistent with the prior solubility study [Gap closed for SB11]; 4) There are no expected impacts on DWPF melt temperature and melter operations due to the minimal ~0.2 weight percent (wt%) increase in Gd concentration relative to previous sludge batches [Gap closed for SB11]; 5) As observed previously, Gd is expected to enter the off-gas system via physical entrainment, but at a slightly higher concentration than what was observed for SB9 melter off-gas pluggage deposits (0.07 wt%) [Gap closed for SB11] ; 6) There are no expected impacts on DWPF recycle or the Recycle Collection Tank glycolate destruction process. [Gap closed for SB11]; 7) Gd is projected to be a trace component in the SB11 glass (<0.5 wt%) and can be ignored for process control. Trace components do not significantly impact glass durability, thus the conclusions of the previous Product Consistency Test evaluation at a fissile mass loading of 2,500 g fissile/m3 glass still applies to SB11. The ~0.1 wt% increase in Gd2O3 concentration relative to the previous study will not impact the predictability of SB11 glass with the DWPF Product Composition Control System (PCCS) models for durability or the acceptability of glass according to the Waste Acceptance Product Specifications (WAPS) criterion for product consistency [Gap closed for SB11]; 8) No additional Toxicity Characteristic Leaching Procedure testing is necessary for SB11 and the hazardous waste specification of the SB11 DWPF waste form is unchanged after the addition of the ABD stream [Gap closed for SB11]. The following summarizes the evaluation of the impacts of adding two-thirds of the ABD material to Tank 51 prior to LTAD: 1) The addition of two-thirds of the ABD increases overall aluminum mass from 1.39×10 4 kg to 1.64×10 4 kg (15.5% ABD Al). The form of the insoluble portion of the Al resulting from ABD addition should be the more readily dissolved Al(OH) 3 and amorphous forms. The portion of the ABD aluminum that is processed by LTAD is expected to be completely soluble, thus requiring that less of the boehmite in the sludge be dissolved to reach the same Al target in the SB. [Gap closed for SB11]; The expected LTAD impact on other components, as related primarily to the components in ABD, are discussed. Gd is expected to remain insoluble during LTAD and not impact the solubility of other components. [Gap closed for SB11]; The addition of two-thirds of the ABD increases overall projected SB11 uranium mass from 4,740 kg to 13,100 kg (63% ABD U) and the projected plutonium mass from 86.0 kg to 89.5 kg (3.9% ABD Pu). The addition of all of the ABD increases overall projected SB11 uranium mass from 4,740 kg to 16,100 kg (70% ABD U) and the projected plutonium mass from 86.0 kg to 90.4 kg (5.3% ABD Pu). The 235 U enrichment will be ≤5%. The fissile uranium will be adequately poisoned by Gd and the fissile Pu will be adequately poisoned by Fe from the sludge. [Gap closed for SB11]; There is a low risk that ABD addition will impact the rheology or pumpability of the slurry. There is a low but higher risk of ABD addition prior to LTAD impacting the settling rate; Based on the evaluation of adding two-thirds of the ABD material and all of the ABD material prior to the LTAD process, there is no volume or mass limit that would need to be imposed on ABD additions prior to LTAD. [Gap closed for SB11]. Revision 1 of this report addresses a variation on the ABD additions and LTAD strategy where sodium hydroxide additions for LTAD may be performed intermittently or concurrently with an ABD addition window. The proposed change does not alter the conclusions of this evaluation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗