Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DISEASE DETECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

National Synchrotron Light Source (NSLS) 2009 Activity Report

2009 was an incredibly exciting year for light sources at Brookhaven. The National Synchrotron Light Source (NSLS) hosted more than 2,200 visiting researchers, who, along with the about 50 members of our scientific staff, produced a total of 957 publications - about 20 percent of which appeared in premier journals. Covering topics ranging from Alzheimer's disease detection to ethanol-powered fuel cells, a sampling of these findings can be found in this Activity Report. We've also seen the resurfacing of some of our long-time users hard work. I was very proud to hear that two of the three recipients of the 2009 Nobel Prize in Chemistry have ties to the NSLS. Venki Ramakrishnan, a former employee in Brookhaven's biology department and long-time user of the NSLS, now at Cambridge University, and Thomas A. Steitz of Yale University, also a long-time NSLS user, shared the prize with Ada E. Yonath of the Weizmann Institute of Science for their work on the structure and function of the ribosome. In the late 1990s, Ramakrishnan and Steitz used protein crystallography at the NSLS to gather atomic-level images of two ribosome subunits: 30S (Ramakrishnan) and 50S (Steitz). Both laureates solved the high-resolution structures for these subunits based on this data. After struggling with a rough budget for several years, we received excellent funding, and then some, this year. In addition to NSLS operations funding, we received 3 million USD in funds from the American Recovery and Reinvestment Act (ARRA). We used that additional money for two exciting projects: construction of a full-field x-ray microscope and acquisition of several advanced x-ray detectors. The x-ray microscope will be able to image objects with a targeted spatial resolution of 30 nanometers. This capability will be particularly important for new initiatives in energy research and will prepare our users for the projected 1-nanometer resolution benchmark at the National Synchrotron Light Source II (NSLS-II). The detectors project is expected to increase the throughput of several high-demand beamlines by an order of magnitude as well as enable new classes of experiments. In addition, a huge chunk of ARRA money - 150 million USD - was put toward accelerating the construction of NSLS-II, which is now taking shape across the street. Now physically much more than just a pile of dirt, NSLS-II was granted Critical Decision 3 status by the Department of Energy (DOE) early last year, giving the official go-ahead for construction. In July, construction began, marked by a groundbreaking ceremony that attracted elected officials, media, and DOE, Battelle, and Stony Brook University representatives from across the state and the country. As progress on NSLS-II continues, we're working with Stony Brook University to identify ways to capitalize on the facility's unique capabilities through the Joint Photon Sciences Institute (JPSI). Included in this effort is a series of workshops to encourage the development and application of the photon sciences with collaborative research between industries, universities, and national laboratories. We helped host three of these workshops this year, focusing on microelectronics, energy storage, and materials in next-generation energy systems. The conversation and ideas generated at these meetings has been fresh and valuable and we hope to use this model to organize research opportunities in other scientific fields. Also this year: Brookhaven was deemed the lead institution for one of DOE's 46 Energy Frontier Research Centers, focused on understanding the underlying nature of superconductivity in complex materials by using techniques at the NSLS and CFN; DOE awarded a 100,000 USD supplemental grant to our detector program to continue the development of a new generation of x-ray detectors that use germanium sensors, which, at high energies, are much more efficient than equivalent ones based on silicon; and funding for one of our largest consortia, Case Western Reserve University's Center for Synchrotron Biosciences (CSB), was renewed through the National Institutes of Health. The CSB, which operates five NSLS beamlines and serves more than 550 users, will receive a five-year, 4-million USD grant to continue to study the structure and dynamics of proteins and nucleic acids. Finally, construction of the new X9 beamline and endstation for small angle x-ray scattering (SAXS) and wide angle x-ray scattering (WAXS) was completed this year. By July, the beamline and endstation were commissioned and serving general users. This allowed for the relocation of the SAXS and WAXS experimental programs from beamline X21 to X9, providing much-needed beam time for the soft condensed matter physics, life sciences, and nanoscience communities.

30 DIRECT ENERGY CONVERSION↗

Data Sources for Biosurveillance

Biosurveillance analyzes timely data, often fusing time series of many different types of data, to infer the status of public health rather than solely exploiting data having diagnostic specificity. Integrated biosurveillance requires a synthesis of analytic approaches derived from the natural disaster, public health, medical, meteorological, and social science communities, among others, and it is the cornerstone of early disease detection. This paper summarizes major systems dedicated to such an endeavor and emphasizes system capabilities that if creatively exploited could contribute to creation of an effective global biosurveillance enterprise.

60 APPLIED LIFE SCIENCES↗

Multichannel waveguides for the simultaneous detection of disease biomarkers

The sensor team at the Los Alamos National Laboratory has developed a waveguide-based optical biosensor that has previously been used for the detection of biomarkers associated with diseases such as tuberculosis, breast cancer, anthrax and influenza in complex biological samples (e.g., serum and urine). However, no single biomarker can accurately predict disease. To address this issue, we developed a multiplex assay for the detection of components of the Bacillus anthracis lethal toxin on single mode planar optical waveguides with tunable quantum dots as the fluorescence reporter. This limited ability to multiplex is still insufficient for accurate detection of disease or for monitoring prognosis. In this manuscript, we demonstrate for the first time, the design, fabrication and successful evaluation of a multichannel planar optical waveguide for the simultaneous detection of at least three unknown samples in quadruplicate. We demonstrate the simultaneous, rapid (30 min), quantitative (with internal standard) and sensitive (limit of detection of 1 pM) detection of protective antigen and lethal factor of Bacillus anthracis in complex biological samples (serum) using specific monoclonal antibodies labeled with quantum dots as the fluorescence reporter.

59 BASIC BIOLOGICAL SCIENCES↗

A Systematic Evaluation of Traditional and Non-Traditional Data Streams for Integrated Global Biosurveillance (Final Report)

Living in a closely connected and highly mobile world presents many new mechanisms for rapid disease spread and in recent years, global disease surveillance has become a high priority. In addition, much like the contribution of non-traditional medicine to curing diseases, non-traditional data streams are being considered of value in disease surveillance. Los Alamos National Laboratory (LANL) was tasked by the Defense Threat Reduction Agency (DTRA)-Joint Science and Technology Office (JSTO) to determine the relevance of data streams for an integrated global biosurveillance system through the use of defined metrics and methodologies. The long-term, broad objective of this project was to provide information and analysis that can be leveraged from existing and developing national and international disease surveillance systems and methodologies, to create a global disease monitoring system, ultimately providing decision makers with timely information to prepare for and mitigate the spread of disease. Specifically, this project evaluated data streams that are currently being used in surveillance systems and data streams that had the potential for being used in surveillance to enable early disease detection. LANL’s focus was on infectious disease surveillance and the term “biosurveillance” will be used to refer to this scope hereafter. Data stream evaluation was conducted using two different methods: Multi criteria decision analysis (MCDA) using a tool called Logical Decisions ® that assigns utility scores to data streams based on weighted metrics and assigned values specific to data stream categories; and a Surveillance Window concept developed at LANL that assigns a window or windows of time specific to a disease within which information coming from various data streams can be determined to have utility. A cross method analysis was performed between the surveillance window based evaluation and the MCDA-based evaluation to identify data stream categories that showed high utility for both methods. In addition, algorithms that can integrate useful data streams to facilitate early disease detection were also examined. This project provided an understanding of data streams relevant to early warning, early detection and monitoring of disease outbreaks. The report describes the results of LANL’s evaluation of 16 data stream categories using the two methods, and recommendations for next steps. The project evolved significantly over its course, and significant improvements in our approaches were made compared to the initial proposed processes. A key outcome of this effort was that LANL was able to bring together several diverse entities involved in disease surveillance and lay the foundation for new collaborations that straddled military and civilian health surveillance. The robust evaluation framework developed by LANL has generated significant interest and there is interest in adopting this framework for various applications both within disease surveillance as well as other public health initiatives. Finally, LANL developed the Biosurveillance Resource Directory (BRD), a relational database that underwent pilot testing by members of the human, plant and animal disease surveillance community. The BRD is intended to be a global resource to facilitate rapid information access.

60 APPLIED LIFE SCIENCES↗

Improving Detection of Disease Re-emergence Using a Web-Based Tool (RED Alert): Design and Case Analysis Study

Background: Currently, the identification of infectious disease re-emergence is performed without describing specific quantitative criteria that can be used to identify re-emergence events consistently. This practice may lead to ineffective mitigation. In addition, identification of factors contributing to local disease re-emergence and assessment of global disease re-emergence require access to data about disease incidence and a large number of factors at the local level for the entire world. This paper presents Re-emerging Disease Alert (RED Alert), a web-based tool designed to help public health officials detect and understand infectious disease re-emergence. Objective: Our objective is to bring together a variety of disease-related data and analytics needed to help public health analysts answer the following 3 primary questions for detecting and understanding disease re-emergence: Is there a potential disease re-emergence at the local (country) level? What are the potential contributing factors for this re-emergence? Is there a potential for global re-emergence? Methods: We collected and cleaned disease-related data (eg, case counts, vaccination rates, and indicators related to disease transmission) from several data sources including the World Health Organization (WHO), Pan American Health Organization (PAHO), World Bank, and Gideon. We combined these data with machine learning and visual analytics into a tool called RED Alert to detect re-emergence for the following 4 diseases: measles, cholera, dengue, and yellow fever. We evaluated the performance of the machine learning models for re-emergence detection and reviewed the output of the tool through a number of case studies. Results: Our supervised learning models were able to identify 82%-90% of the local re-emergence events, although with 18%-31% (except 46% for dengue) false positives. This is consistent with our goal of identifying all possible re-emergences while allowing some false positives. The review of the web-based tool through case studies showed that local re-emergence detection was possible and that the tool provided actionable information about potential factors contributing to the local disease re-emergence and trends in global disease re-emergence. Conclusions: To the best of our knowledge, this is the first tool that focuses specifically on disease re-emergence and addresses the important challenges mentioned above.

60 APPLIED LIFE SCIENCES↗

Reconfigurable acquisition system with integrated optics for a portable flow cytometer

Portable and inexpensive scientific instruments that are capable of performing point of care diagnostics are needed for applications such as disease detection and diagnosis in resource-poor settings, for water quality and food supply monitoring, and for biosurveillance activities in autonomous vehicles. In this paper, we describe the development of a compact flow cytometer built from three separate, customizable, and interchangeable modules. The instrument as configured in this work is being developed specifically for the detection of selected Centers for Disease Control (CDC) category B biothreat agents through a bead-based assay: E. coli O157:H7, Salmonella, Listeria, and Shigella. It has two-color excitation, three-color fluorescence and light scattering detection, embedded electronics, and capillary based flow. However, these attributes can be easily modified for other applications such as cluster of differentiation 4 (CD4) counting. Proof of concept is demonstrated through a 6-plex bead assay with the results compared to a commercially available benchtop-sized instrument.

60 APPLIED LIFE SCIENCES↗

Application of cabin atmosphere monitors to rapid screening of breath samples for the early detection of disease states

Analysis of human breath is a nonintrusive method to monitor both endogenous and exogenous chemicals found in the body. Several technologies were investigated and developed which are applicable to monitoring some organic molecules important in both physiological and pathological states. Two methods were developed for enriching the organic molecules exhaled in the breath of humans. One device is based on a respiratory face mask fitted with a polyethylene foam wafer; while the other device is a cryogenic trap utilizing an organic solvent. Using laboratory workers as controls, two organic molecules which occurred in the enriched breath of all subjects were tentatively identified as lactic acid and contisol. Both of these substances occurred in breath in sufficient amounts that the conventional method of gas-liquid chromatography was adequate for detection and quantification. To detect and quantitate trace amounts of chemicals in breath, another type of technology was developed in which analysis was conducted using high pressure liquid chromatography and mass spectrometry.

Valentine, J. L.↗

Utilization of ERTS data to detect plant diseases and nutrient deficiencies, soil types and moisture levels

The author has identified the following significant results. A significant finding is the identification and delineation of a large soil association in Obion County, West Tennessee. These data are now being processed through the scanner and computer and will be included in the next report along with pictures of printout and imagery. Channel 7 appears to provide the most useful imagery related to soil differences. Soil types have been identified through the use of aircraft imagery. However, a soil association map appears to be the best that space imagery will provide. The exception to this will be large areas of a uniform soil type as occurs in the great plains.

Parks, W. L.↗

Utilization of ERTS data to detect plant diseases and nutrient deficiencies, soil types and moisture levels

The author has identified the following significant results. A significant finding to date is the delineation of the Memphis soil association in Obion County, Dyer County, and in portions of Kentucky. This soil association was delineated mechanically through the use of imagery in the digital tape format, appropriate computer software, and an IBM/360/05 computer. The Waverly-Swamp association as well as the Obion River have been identified on the ERTS-1 imagery as well as on the computer printout. These findings demonstrate the feasibility of delineating major soil associations through vegetative cover common to the association. Channel 7 provides the most information for studies of this type. Computer density printouts assist markedly in making density separations and delineating major soil moisture differences; however, signatures for soil moisture classification for this area of mixed land uses in relatively small tracts have not yet been developed.

Parks, W. L.↗

Utilization of ERTS data to detect plant diseases and nutrient deficiencies, soil types and moisture levels

The author has identified the following significant results. Findings demonstrate the feasibility of delineating major terrain features, land uses, and crop species through computerized analyses. Channel 6 appears to give the most information for making separations of this type. By enlarging satellite imagery and visually comparing this with high altitude aerial photographs, locating small terrain features and cropland areas on satellite imagery is greatly facilitated. Forest types are discernable on the 2402 imagery with a #25 filter: pine stands have dark tones, hardwood stands have light tones, and pine-hardwood have intermediate tones. No textural differences are evident on this type of imagery. However, on the 2424 imagery with #89B filter, textural differences are evident but tonal differences are absent. Areas of considerable texture are interpreted as stands of high volume while areas of suppressed texture are of low volume. The 2402 imagery with a #57 filter appears to have little information of importance in timber inventory.

Parks, W. L.↗

Utilizing ERTS imagery to detect plant diseases and nutrient deficiencies, soil types and soil moisture levels

The author has identified the following significant results. ERTS-1 imagery may be used to delineate soil associations. It does have the capacity to divide soils into groups such that their land use and management would be similar. It offers definite potential for making grass flood-plain, wetland, river shoreline, and land use change surveys. Production of volume strata and forest type from the two usable bands of ERTS-1 imagery were of questionable value. No imagery was received for evaluation during the time of year when maine dwarf mosaic virus and southern corn leaf blight were active.

Parks, W. L.↗

Early detection of disease program: Evaluation of the cellular immune response

The early cellular responses of specific components of the leukocyte and epithelial cell populations to foreign challenges of both an infectious and noninfectious character were evaluated. Procedures for screening potential flight crews were developed, documented, and tested on a control population. Methods for preparing suitable populations of lymphocytes, polymorphonuclear leukocytes, macrophages, and epithelial cells were first established and evaluated. Epithelial cells from viral infected individuals were screened with a number of anti-viral antisera. This procedure showed the earliest indication of disease as well as providing a specific diagnosis to the physicians. Both macrophages and polymorphonuclear leukocytes were studied from normal individuals, smokers, and patients with viral infections. Newer techniques enabling better definition of lymphocyte subpopulations were then developed, namely the E and EAC rosette procedures for recognition of T (thymus-derived) and B (bone-marrow-derived) lymphocyte subpopulations. Lymphocyte and lymphocyte subpopulation response to multiple mitogens have been evaluated.

Criswell, B. S.↗

Early detection of disease program: Evaluation of the cellular immune response

Surfaces of normal, cultured, and mitogen-stimulated mouse lymphoid cells were examined by scanning electron microscopy (SEM). Lymphocytes with smooth, highly villous and intermediate surfaces were observed in cell suspensions from both spleens and thymuses of normal mice and from spleens of congenitally athymic (nude) mice. Several strain-specific surface features were noted, including the spine-like appearance of microvilli on C57B1/6 lymphocytes. Although thymus cell suspensions contained somewhat more smooth cells than did spleen cell preparations, lymphocyte derivation could not be inferred from SEM examination. Studies of cells stimulated with mitogenic agents for thymus-derived lymphocytes (concanavalin A) or for bone marrow-derived lymphocytes (lipopolysaccharide) suggested that, in the mouse, development of a complex villous surface is a general concomitant of lymphocyte activation and transformation.

Criswell, B. S.↗

Early detection of disease: The correlation of the volatile organic profiles from patients with upper respiratory infections with subjects of normal profiles

A method is described whereby a transevaporator is used for sampling 60-100 microns of aqueous sample. Volatiles are stripped from the sample either by a stream of helium and collection on a porous polymer, Tenax, or by 0.8 ml of 2-chloropropane and collected on glass beads. The volatiles are thermally desorbed into a precolumn which is connected to a capillary gas chromatographic column for analysis. The technique is shown to be reproducible and suitable for determining chromatographic profiles for a wide variety of sample types. Using a transevaporator sampling technique, the volatile profiles from 70 microns of serum were obtained by capillary column gas chromatography. The complex chromatograms were interpreted by a combination of manual and computer techniques and a two peak ratio method devised for the classification of normal and virus infected sera. Using the K-Nearest Neighbor approach, 85.7 percent of the unknown samples were classified correctly. Some preliminary results indicate the possible use of the method for the assessment of virus susceptibility.

Zlatkis, A.↗