Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIAPHRAGM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An Investigation of the Characteristics of Steel Diaphragms for Automatic Fuel-Injection Valves

This research on steel diaphragms was undertaken at the Langley Memorial Aeronautical Laboratory, as a part of a general investigation on fuel injection engines for aircraft. The work determined the load-deflection, load- deformation and hysteresis characteristics for single diaphragms having thicknesses from 0.00s inch to 0.012 inch, and for similar diaphragms tested in multiple having total thicknesses from 0.012 inch to 0.180 inch. The elastic limit loads and deflections, and rupture points of single diaphragms were also determined. Some work was done on diaphragms having central orifices in order to determine the effect of orifice diameter upon the load deflection characteristics.

Joachim, W F↗

Nonmetallic Diaphragms for Instruments

This report, the second of a series of reports relating to the general subject of instrument diaphragms. The first report of the series was published as Technical Report no. 165, "diaphragms for aeronautic instruments," and comprised an outline of historical developments and theoretical principles. The present report relates entirely to nonmetallic diaphragms, the use of which in certain types of pressure elements has been increasing for some time. Little, if any, information has been available to aid the designer of instruments using this form of pressure element. It was to attempt to meet the need for such information that the investigation reported in this paper was undertaken. The report describes the various materials which have been used as nonmetallic diaphragms, discusses the factors which affect the performance of the diaphragms and gives the results of tests made for the purpose of investigating the effect produced by these factors.

Eaton, H N↗

Theoretical Evaluation of Electroactive Polymer Based Micropump Diaphragm for Air Flow Control

An electroactive polymer (EAP), high energy electron irradiated poly(vinylidene fluoride-trifluoroethylene) [P(VDFTrFE)] copolymer, based actuation micropump diaphragm (PAMPD) have been developed for air flow control. The displacement strokes and profiles as a function of amplifier and frequency of electric field have been characterized. The volume stroke rates (volume rate) as function of electric field, driving frequency have been theoretically evaluated, too. The PAMPD exhibits high volume rate. It is easily tuned with varying of either amplitude or frequency of the applied electric field. In addition, the performance of the diaphragms were modeled and the agreement between the modeling results and experimental data confirms that the response of the diaphragms follow the design parameters. The results demonstrated that the diaphragm can fit some future aerospace applications to replace the traditional complex mechanical systems, increase the control capability and reduce the weight of the future air dynamic control systems. KEYWORDS: Electroactive polymer (EAP), micropump, diaphragm, actuation, displacement, volume rate, pumping speed, clamping ratio.

Xu, Tian-Bing↗

Interstitial space and collagen alterations of the developing rat diaphragm

The effect of growth on the relative interstitial space [%total cross-sectional area (CSA)] and collagen content of the rat diaphragm muscle was examined at postnatal ages of 0, 7, 14, and 21 days as well as in adult males. The proportion of interstitial space relative to total muscle CSA was determined by computerized image analysis of lectin-stained cross sections of diaphragm muscle. To assess collagen content and extent of collagen maturation (i.e., cross-linking), high-pressure liquid chromatography analysis was used to measure hydroxyproline concentration and the nonreducible collagen cross-link hydroxylysylpyridinoline (HP), respectively. At birth, interstitial space accounted for approximately 47% of total diaphragm muscle CSA. During postnatal growth, the relative contribution of interstitial space decreased such that by adulthood the interstitial space accounted for approximately 18% of total muscle CSA. The change in relative interstitial space occurred without a concomitant change in hydroxyproline concentration. However, the concentration of HP markedly increased with age such that the adult diaphragm contained approximately 17 times more HP than at birth. These results indicate that during development the relative CSA occupied by interstitial space decreases as muscle fiber size increases. However, the reduction in relative interstitial space is not associated with a change in collagen concentration. Thus collagen density in the interstitial space may increase with age. It is possible that the observed changes in relative interstitial space and collagen influence the passive length-force properties of the diaphragm.

NASA Program Space Physiology and Countermeasures↗

Electro-Active Device Using Radial Electric Field Piezo-Diaphragm for Control of Fluid Movement

A fluid-control electro-active device includes a piezo-diaphragm made from a ferroelectric material sandwiched by first and second electrode patterns configured to introduce an electric field into the ferroelectric material when voltage is applied thereto. The electric field originates at a region of the ferroelectric material between the first and second electrode patterns, and extends radially outward from this region of the ferroelectric material and substantially parallel to the plane of the ferroelectric material. The piezo-diaphragm deflects symmetrically about this region in a direction substantially perpendicular to the electric field. An annular region coupled to and extending radially outward from the piezo-diaphragm perimetrically borders the piezo-diaphragm, A housing is connected to the region and at least one fluid flow path with piezo-diaphragm disposed therein.

Robert G Bryant↗

Method of construction for internally cooled diaphragms for centrifugal compressor

An internally-cooled compressor is provided including a casing and a diaphragm disposed in the casing. The diaphragm includes a diaphragm box defining a plurality of box channels and a bulb defining a plurality of bulb channels. A plurality of return channel vanes connect the diaphragm box and bulb in fluid communication, such that each return channel vane defines a plurality of return vane conduits coupled in fluid communication with the plurality of box channels and the plurality of bulb channels thereby forming a section of a cooling pathway. The cooling pathway is configured such that a cooling agent introduced from an external coolant source into the diaphragm box and flowing through a box channel flows through a return vane conduit into and through a bulb channel and back through another return vane conduit into another box channel before flowing back to the external coolant source.

42 ENGINEERING↗

Durable, Ultra-Thin Diaphragms for Liquid Alkaline Water Electrolysis

W. L. Gore & Associates assembled a world class team (De Nora Tech, LLC; New York University; and thyssenkrupp nucera) to develop durable, ultra-low resistance diaphragms that dramatically improve system efficiency, dynamic response, and operational flexibility. To enable the use of ultra-thin diaphragms, an optimized electrode package was chosen as part of an electrode down select study. Ultra-thin diaphragms based on microporous polymer scaffolds imbibed with zirconia nanoparticles were developed and tested. Performance and durability on par with incumbent materials was demonstrated. A transparent electrolyzer to directly observe in-situ diaphragm-bubble interactions was designed and built, and simultaneous optical and electrochemical performance tests were performed. A Pressurized Alkaline Water Electrolysis (PAWE) single cell test station was designed to support advanced R&D in high-pressure electrolysis, particularly for evaluating novel electrode and separator configurations under elevated temperature and pressure operating conditions. Due to early project termination, the original scope could not be fully achieved.

08 HYDROGEN↗

Micromachined Piezoresistive-sensed Diaphragms for Infrasonic Monitoring

Micromachined, piezoresistive-sensed diaphragms are designed and fabricated specifically for infrasound sensing applications. Relatively large diaphragms, up to 6 mm × 6 mm, are fabricated to meet the high sensitivity requirements of infrasonic monitoring. A double-stack SOI wafer process is used, resulting in a streamlined two-mask process without the need for doping or ion-implantation. Pressure-sensitivities of diaphragms are studied using a custom static calibration set-up. Here, the piezoresistance of longitudinal and transverse resistors are studied over a large pressure range of ±5,500 Pa so that the linear and nonlinear response regions of diaphragms are observed. Measurements are compared against a nonlinear finite element simulation—shown to accurately predict the sensor’s behavior over a large response range.

47 OTHER INSTRUMENTATION↗

APU diaphragm testing

The Auxiliary Power Unit (APU) fuel (hydrazine) tanks were removed from the Columbia Shuttle during major modification of the vehicle, because of long-term hydrazine compatibility concerns. The three tanks had been in service for 11 years. As part of an effort to determine whether the useful life of the fuel tanks can be extended, examination of the ethylene propylene rubber (EPR) diaphragm and the metal casing from one of the APU tanks was required. NASA Johnson Space Center Propulsion and Power Division requested the NASA Johnson Space Center White Sands Test Facility to examine the EPR diaphragm for signs of degradation that might limit the life of its function in the APU tank and to examine the metal casing for signs of surface corrosion. No appreciable degradation of the EPR diaphragm was noted. A decrease in the tensile properties was found, but tensile failure is considered unlikely because the metal casing constrains the diaphragm, preventing it from elongating more than a few percent. The titanium casing showed no evidence of surface corrosion.

Shelley, Richard↗

Design of fabric preforms for double diaphragm forming

Resin Transfer Molding (RTM) has the potential of becoming one of the most cost effective ways of producing composite structures since the raw materials used, resin and dry fabric, are less costly than prepregs. Unfortunately these low material costs are offset by the high labor costs incurred to layup the dry fabric into 3D shapes. To reduce the layup costs, double diaphragm forming is being investigated as a potential technique for creating a complex 3D preform from a simple flat layup. As part of our effort to develop double diaphragm forming into a production capable process, we have undertaken a series of experiments to investigate the interactions between process parameters, mold geometry, fabric weave, tow size, and the quality of the formed part. The results of these tests will be used to determine the forming geometry limitations of double diaphragm forming and to characterize the formability of fabric configurations. An important part of this work was the development of methods to measure and analyze fiber orientations, deformation angles, tow spreading, and shape conformation of the formed parts. This paper will describe the methods used to mark plies, the double diaphragm forming process, the techniques used to measure the formed parts, and the calculation of the parameters of interest. The results can be displayed as 3D contour plots. These experimental results have also been used to verify and improve a computer model which simulates the draping of fabrics over 3D mold shapes.

Luby, Steven↗

Fused silica diaphragm module for high temperature pressure transducers

A high temperature pressure transducer and sensing apparatus to determine the deflection of the transducer diaphragm is disclosed. The pressure transducer utilizes a fused silica diaphragm (12) which is illuminated at selected locations by a coherent laser source (52) via optical fibers (38, 46). The light reflected by the diaphragm (12) forms interference fringe patterns which are focused by gradient index rod lenses (36) on the ends of optical fibers (40, 48) for transmission to a fringe counting circuit (54). By digital techniques, the fringe count is converted into a determination of diaphragm deflection.

Berthold, III, John W.↗

CFD Fuel Slosh Modeling of Fluid-Structure Interaction in Spacecraft Propellant Tanks with Diaphragms

Liquid sloshing within spacecraft propellant tanks causes rapid energy dissipation at resonant modes, which can result in attitude destabilization of the vehicle. Identifying resonant slosh modes currently requires experimental testing and mechanical pendulum analogs to characterize the slosh dynamics. Computational Fluid Dynamics (CFD) techniques have recently been validated as an effective tool for simulating fuel slosh within free-surface propellant tanks. Propellant tanks often incorporate an internal flexible diaphragm to separate ullage and propellant which increases modeling complexity. A coupled fluid-structure CFD model is required to capture the damping effects of a flexible diaphragm on the propellant. ANSYS multidisciplinary engineering software employs a coupled solver for analyzing two-way Fluid Structure Interaction (FSI) cases such as the diaphragm propellant tank system. Slosh models generated by ANSYS software are validated by experimental lateral slosh test results. Accurate data correlation would produce an innovative technique for modeling fuel slosh within diaphragm tanks and provide an accurate and efficient tool for identifying resonant modes and the slosh dynamic response.

Sances, Dillon J.↗

Investigation of H2 Diaphragm Compressors to Enable Low-Cost Long-Life Operation

This is a “short” annual report to DOE Fuel Cell Technology Office describing the research on modeling and materials analysis of diaphragms in a diaphragm-type hydrogen compressor. The compressor design details and diaphragm materials were provided by PDC Machines, Inc., a commercial manufacturer of diaphragm-type hydrogen compressors that PNNL is partnering with in this project

Rohatgi, Aashish↗

Fiber laser microphones with graphene diaphragms

An acoustic sensor comprises a sensing head comprising an optical fiber having a tip. A graphene diaphragm is disposed on the tip and is configured to vibrate in response to an acoustic signal. A fiber laser is optically coupled to the sensing head. The fiber laser comprises a first set of fiber Bragg gratings and a second set of fiber Bragg gratings. A gap is present between the first set and the second set of fiber Bragg gratings. The fiber laser is configured to generate a sensing optical signal having a first intensity in response to an excitation optical signal, the sensing optical signal impinging on the graphene diaphragm such that a feedback optical signal is reflected from the graphene diaphragm towards the fiber laser and has and has a second intensity modulated by the vibration of the graphene diaphragm that corresponds to the acoustic signal.

Liao, Shaolin↗

Quantification of the Variability of Diaphragm Motion and Implications for Treatment Margin Construction

Purpose: To quantify the variability of diaphragm motion during free-breathing radiotherapy of lung patients and its effect on treatment margins to account for geometric uncertainties. Methods and Materials: Thirty-three lung cancer patients were analyzed. Each patient had 5-19 cone-beam scans acquired during different treatment fractions. The craniocaudal position of the diaphragm dome on the same side as the tumor was tracked over 2 min in the projection images, because it is both easily visible and a suitable surrogate to study the variability of the tumor motion and its impact on treatment margins. Intra-acquisition, inter-acquisition, and inter-patient variability of the respiratory cycles were quantified separately, as were the probability density functions (PDFs) of the diaphragm position over each cycle, each acquisition, and each patient. Asymmetric margins were simulated using each patient PDF and compared to symmetric margins computed from a margin recipe. Results: The peak-to-peak amplitude variability (1 SD) was 3.3 mm, 2.4 mm, and 6.1 mm for the intra-acquisition, inter-acquisition, and inter-patient variability, respectively. The average PDF of each cycle was similar to the sin{sup 4} function but the PDF of each acquisition was closer to a skew-normal distribution because of the motion variability. Despite large interfraction baseline variability, the PDF of each patient was generally asymmetric with a longer end-inhale tail because the end-exhale position was more stable than the end-inhale position. The asymmetry of the PDF required asymmetric margins around the time-averaged position to account for the position uncertainty but the average difference was 1.0 mm (range, 0.0-4.4 mm) for a sharp penumbra and an idealized online setup correction protocol. Conclusion: The respiratory motion is more irregular during the fractions than between the fractions. The PDF of the respiratory motion is asymmetrically distributed. Both the intra-acquisition variability and the PDF asymmetry have a limited impact on dose distributions and inferred margins. The use of a margin recipe to account for respiratory motion with an estimate of the average motion amplitude was adequate in almost all patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the stability of capacitance-diaphragm gauges with ceramic membranes

Capacitance-diaphragm gauges with ceramic membranes or diaphragms have been on the market for about 15 years. The long-term stability of these devices with full scales from 13 Pa to 133 kPa has been tested in the past decade by the calibration of gauges used by the manufacturer as reference gauges on the production line. These reference gauges were calibrated annually on a primary standard. It was found that the reproducibility of these devices depends on their full scale. For 13 Pa, the annual reproducibility near full scale varied between 0.02% and 0.04%, and for full scales of 133 Pa and higher, it varied between 0.005% and 0.03% of full scale. The reproducibility of the ceramic capacitance-diaphragm gauges for full scales of 133 Pa and 1.3 kPa was significantly lower than the uncertainty of a primary standard applying the static-expansion method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-G-BRA-07: An Innovative Fiducial-Less Tracking Method for Radiation Treatment of Abdominal Tumors by Diaphragm Disparity Analysis

Purpose: To investigate the feasibility of tracking abdominal tumors without the use of gold fiducial markers Methods: In this simulation study, an abdominal 4DCT dataset, acquired previously and containing 8 phases of the breathing cycle, was used as the testing data. Two sets of DRR images (45 and 135 degrees) were generated for each phase. Three anatomical points along the lung-diaphragm interface on each of the Digital Reconstructed Radiograph(DRR) images were identified by cross-correlation. The gallbladder, which simulates the tumor, was contoured for each phase of the breathing cycle and the corresponding centroid values serve as the measured center of the tumor. A linear model was created to correlate the diaphragm’s disparity of the three identified anatomical points with the center of the tumor. To verify the established linear model, we sequentially removed one phase of the data (i.e., 3 anatomical points and the corresponding tumor center) and created new linear models with the remaining 7 phases. Then we substituted the eliminated phase data (disparities of the 3 anatomical points) into the corresponding model to compare model-generated tumor center and the measured tumor center. Results: The maximum difference between the modeled and the measured centroid values across the 8 phases were 0.72, 0.29 and 0.30 pixels in the x, y and z directions respectively, which yielded a maximum mean-squared-error value of 0.75 pixels. The outcomes of the verification process, by eliminating each phase, produced mean-squared-errors ranging from 0.41 to 1.28 pixels. Conclusion: Gold fiducial markers, requiring surgical procedures to be implanted, are conventionally used in radiation therapy. The present work shows the feasibility of a fiducial-less tracking method for localizing abdominal tumors. Through developed diaphragm disparity analysis, the established linear model was verified with clinically accepted errors. The tracking method in real time under different radiation therapy platforms will be further investigated.

60 APPLIED LIFE SCIENCES↗

Novel Titanium Electrowinning Process Using Specialized Segmented Diaphragms

The primary goal of this project is to develop a stable and efficient electrowinning process for extraction of titanium (Ti) metal. The key innovation is the use of specialized diaphragms designed such that they eliminate undesired reactions on the diaphragm surface. The diaphragm design enables efficient electrowinning operation and allows for stable electrowinning of Ti metal. This facilitates low-cost, energy-efficient Ti sponge production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗