Photovoltaic system derived data for determining the solar resource and for modeling the performance of other photovoltaic systems

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. Here, a method was developed to back-solve for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the measured ac power of south-facing PV module/micro-inverter systems. The method was validated using one year of irradiance and PV performance measurements for five PV systems, each with a different tilt/azimuth orientation, and located in Golden, Colorado. Compared to using a measured global horizontal irradiance for PV performance model input, using the back-solved values of DNI and DHI only increased the range of mean bias deviations from measured values by 0.6% for the modeled annual averages of the global tilt irradiance and ac power for the five PV systems. Correcting for angle-of-incidence effects is an important feature of the method to prevent underestimating the solar resource and for modeling the performance of PV systems with more dissimilar PV module orientations. The results for the method were also shown more favorable than the results when using an existing power projection method for estimating the ac power.

14 SOLAR ENERGY↗

Evaluation of global horizontal irradiance to plane-of-array irradiance models at locations across the United States

We report an evaluation of the accuracy of combinations of models that estimate plane-of-array (POA) irradiance from measured global horizontal irradiance (GHI). This estimation involves two steps: 1) decomposition of GHI into direct and diffuse horizontal components and 2) transposition of direct and diffuse horizontal irradiance (DHI) to POA irradiance. Measured GHI and coincident measured POA irradiance from a variety of climates within the United States were used to evaluate combinations of decomposition and transposition models. A few locations also had DHI measurements, allowing for decoupled analysis of either the decomposition or the transposition models alone. Results suggest that decomposition models had mean bias differences (modeled versus measured) that vary with climate. Transposition model mean bias differences depended more on the model than the location. Lastly, when only GHI measurements were available and combinations of decomposition and transposition models were considered, the smallest mean bias differences were typically found for combinations which included the Hay/Davies transposition model.

14 SOLAR ENERGY↗

The Holy Grail of Resource Assessment: Low Cost Ground-Based Measurements with Good Accuracy

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. The method used back-solves for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the micro-inverter ac production data. When the derived values of DNI and DHI were then used to model the performance of other PV systems, the annual mean bias deviations were within +/-4%, and only 1% greater than when the PV performance was modeled using high quality irradiance measurements. An uncertainty analysis shows the method better suited for modeling PV performance than using satellite-based global horizontal irradiance.

14 SOLAR ENERGY↗

SU-E-T-28: A Treatment Planning Comparison of Volumetric Modulated Arc Therapy Vs. Proton Therapy for Post-Mastectomy Radiotherapy

Purpose: The delivery of post-mastectomy radiotherapy (PMRT) can be challenging for patients with left-sided breast cancer due to the PTV size and proximity to critical organs. This study investigates the use of protons for PMRT in a clinically-representative cohort of patients, and quantitatively compares volumetric modulated arc therapy (VMAT) to proton therapy to have an evidence-based rationale for selecting a treatment modality for these patients. Methods: Eight left-sided PMRT patients previously treated at our clinic with VMAT were identified for the study. PTVs included the chest wall and regional lymph nodes. Passively scattered (PS) and intensity modulated proton therapy (IMPT) plans were constructed using the Eclipse proton planning system. The resulting plans were compared to the original VMAT plan on the basis of PTV coverage; dose homogeneity index (DHI) and conformity index (CI); dose to organs at risk (OAR); tumor control probability (TCP), normal tissue complication probability (NTCP) and secondary cancer complication probability (SCCP). Differences were tested for significance using the paired Student's t-test (p<0.01). Results: All modalities produced clinically acceptable PMRT plans. The comparison demonstrated proton treatment plans provide significantly lower NTCP values for the heart and the lung while maintaining significantly better CI and DHI. At a prescribed dose of 50.4 Gy (RBE) in the PTV, the calculated mean NTCP value for the patients decreased from 1.3% to 0.05% for the whole heart (cardiac mortality) and from 3.8% to 1.1% for the lungs (radiation pneumonitis) for both proton therapy plans from VMAT plans. Both proton modalities showed a significantly lower SCCP for the contralateral breast compared to VMAT. Conclusion: All three plans (VMAT, PS, and IMPT) provide acceptable treatment plans for PMRT. However, proton therapy shows a significant advantage over VMAT with regards to sparing OARs and may be more advantageous for patients with unfavorable anatomy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-87: Comparison of Advanced Radiotherapy Techniques for Post- Mastectomy Breast Cancer Patients

Purpose: To determine if bolus electron conformal therapy (Bolus-ECT) combined with intensity modulated x-ray therapy (IMXT) and flattening filter free volumetric modulated arc therapy (FFF-VMAT (6x and 10x)) can maintain equal or better dose coverage than standard volumetric modulated arc therapy (Std-VMAT) while reducing doses to organs at risk (OARs). Methods: Bolus-ECT with IMXT, FFF-VMAT, and Std-VMAT treatment plans were produced for ten post-mastectomy radiotherapy (PMRT) patients previously treated at our clinic. The treatment plans were created on commercially available treatment planning system (TPS) and all completed treatment plans were reviewed and approved by a radiation oncologist. The plans were evaluated based on planning target volume (PTV) coverage, tumor control probability (TCP), dose homogeneity index (DHI), conformity index (CI), and dose to organs at risk (OAR). Results: All techniques produced clinically acceptable PMRT plans. Overall, Bolus-ECT with IMXT exhibited higher maximum dose compared to all VMAT techniques. Bolus-ECT with IMXT and FFF-VMAT10x had slightly improved TCP over FFF-VMAT6x and Std-VMAT. However, all VMAT techniques showed improved CI and DHI over Bolus-ECT with IMXT. All techniques showed very similar mean lung dose. Bolus-ECT with IMXT exhibited a reduced mean heart dose over Std-VMAT. Both FFF-VMAT techniques had higher mean heart dose compared to Std-VMAT. In addition, Bolus-ECT with IMXT was able to reduce mean dose to the contralateral breast compared to Std-VMAT and both FFF-VMAT techniques had comparable but slightly reduced dose compared to Std-VMAT. Conclusion: This work has shown that Bolus-ECT with IMXT produces clinically acceptable plans while reducing OAR doses. Both FFF-VMAT techniques are comparable to Std-VMAT with slight improvements. Even though all VMAT techniques produce more homogenous and conformal dose distributions, Bolus-ECT with IMXT is a viable option for treating post-mastectomy patients possibly leading to reduced risks of normal tissue complications.

60 APPLIED LIFE SCIENCES↗

Sci-Thur PM – Brachytherapy 06: 3D Printed Surface Applicators for High Dose Rate Brachytherapy

Purpose: The purpose of this work is to develop a new applicator for administering high dose rate (HDR) brachytherapy using 3D printing technology. Primary advantages of using a 3D printed applicator will be to offer a more streamlined approach for therapists and patients while achieving better conformity, reproducibility, and patient specific applicators. Methods: A phantom study was conducted to measure the effectiveness of a 3D printed surface applicator by analyzing tumours on three locations of the body: the foot, nose, and scalp. The applicator was designed using Eclipse and further modified using Blender to create the catheter tunnels before being printed on a Lulzbot Taz 5 3D printer. A radiation plan was made using Oncentra Brachytherapy for a control treatment option using Freiburg Flaps and one with the novel method of a 3D printed applicator. A comparative analysis was made using D90, D100, V100, V150, and V200 Results: The 3D printed applicator showed comparable dose coverage with significant improvements on highly irregular surfaces when analyzed against a plan made using Freiburg Flaps. Although both plans exhibited complete tumour coverage, the 3D applicator showed improvements in D90 and V150 and the 3D applicator had a dose homogeneity index (DHI) of 0.99 compared to a DHI of 0.97 for the control. Therapist prep time also dropped significantly due to the lack of need for a thermoplastic mesh. Conclusions: 3D printed applicators for treatment of superficial sites proved to offer more patient convenience, less prep time, better conformity and tighter margins.

60 APPLIED LIFE SCIENCES↗

Albedo and Diffuse POA Measurements to Evaluate Transposition Model Uncertainty

Albedo and diffuse plane of array (DPOA) measurements are used in addition to standard global horizontal irradiance (GHI), direct normal irradiance (DNI), diffuse horizontal irradiance (DNI), and plane of array irradiance (POA) measurements to determine the impact of albedo on transposition model performance. Albedo measurements averaged 0.214. Daily albedo values ranged from 0.148 to 0.236 and were found to be correlated to daily relative humidity. DPOA measurements were compared to calculated DPOA values (from POA and DNI), and helped identify a suspected deviation from due south in the azimuth of the POA measurement. Since the measured albedo average was close to the typical fixed $^{albedo = 0.2}$ assumption, little difference was seen between using measured and fixed albedo (~0.15% differences in mean bias difference (MBD) and root mean squared difference (RMSD)). However, evaluation of transposition models at other fixed albedos showed an albedo change of 0.1 is found to increase total modeled insolation by approximately 1%. Thus, for locations with different ground surfaces (e.g., persistent snow cover of black surfaces), the impact of using measured albedo instead of the fixed $^{albedo = 0.2}$ assumption may be greater. Measurement deviations resulted in up to 2% changes in MBD and RIVISD when switching between interrelated measurements (e.g., GHI and DHI as inputs to transposition models versus DNI and DHI as inputs). Variation among transposition models was also up to 2% MBD and RMSD. Thus, for this data set, measurement deviation and transposition model selection are found to have more impact than using measured albedo instead fixed albedo.

42 ENGINEERING↗

Measuring Pressure Has a New Standard

The Force-Balanced Piston Gauge (FPG) tests and calibrates instrumentation operating in the low pressure range. The system provides a traceable, primary calibration standard for measuring pressures in the range of near 0 to 15 kPa (2.2 psi) in both gauge and absolute measurement modes. The hardware combines a large area piston-cylinder with a load cell measuring the force resulting from pressures across the piston. The mass of the piston can be tared out, allowing measurement to start from zero. A pressure higher than the measured pressure, which keeps the piston centered, lubricates an innovative conical gap located between the piston and the cylinder, eliminating the need for piston rotation. A pressure controller based on the control of low gas flow automates the pressure control. DHI markets the FPG as an automated primary standard for very low-gauge and absolute pressures. DHI is selling the FPG to high-end metrology laboratories on a case by case basis, with a full commercial release to follow.

Source record↗

PV Derived Data for Predicting Performance; NREL (National Renewable Energy Laboratory)

A method is described for providing solar irradiance data for modeling PV performance by using measured PV performance data and back-solving for the unknown direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI), which can then be used to model the performance of PV systems of any size, PV array tilt, or PV array azimuth orientation. Ideally situated for using the performance data from PV modules with micro-inverters, the PV module operating current is used to determine the global tilted irradiance (GTI), and a separation model is then used to determine the DNI and DHI from the GTI.

14 SOLAR ENERGY↗

The Holy Grail of Resource Assessment: Low Cost Ground-Based Measurements with Good Accuracy

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. The method used back-solves for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the micro-inverter ac production data. When the derived values of DNI and DHI were then used to model the performance of other PV systems, the annual mean bias deviations were within +/- 4%, and only 1% greater than when the PV performance was modeled using high quality irradiance measurements. An uncertainty analysis shows the method better suited for modeling PV performance than using satellite-based global horizontal irradiance.

14 SOLAR ENERGY↗

The Holy Grail of Resource Assessment: Low Cost Ground-Based Measurements with Good Accuracy: Preprint

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. The method used back-solves for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the micro-inverter ac production data. When the derived values of DNI and DHI were then used to model the performance of other PV systems, the annual mean bias deviations were within plus or minus 4 percent, and only 1 percent greater than when the PV performance was modeled using high quality irradiance measurements. An uncertainty analysis shows the method better suited for modeling PV performance than using satellite-based global horizontal irradiance.

14 SOLAR ENERGY↗

National Solar Radiation Database (NSRDB)

The National Solar Radiation Database (NSRDB) is a serially complete collection of meteorological and solar irradiance data sets for the United States and a growing list of international locations for 1998-2023. The NSRDB is updated annually and provides foundational information to support U.S. Department of Energy programs, research, industry and the general public. The NSRDB provides time-series data at 30-minute resolution of resource averaged over surface cells of 0.038 degrees in both latitude and longitude, or nominally 4 km in size. Additionally time series data at 5 minutes for the US and 10 minutes for North, Central and South America at 2 km resolution are produced from the next generation of GOES satellites and made available from 2019. The solar radiation values represent the resource available to solar energy systems. The data was created using cloud properties which are generated using the AVHRR Pathfinder Atmospheres-Extended (PATMOS-x) algorithms developed by the University of Wisconsin. Fast all-sky radiation model for solar applications (FARMS) in conjunction with the cloud properties, and aerosol optical depth (AOD) and precipitable water vapor (PWV) from ancillary source are used to estimate solar irradiance (GHI, DNI, and DHI). The Global Horizontal Irradiance (GHI) is computed for clear skies using the REST2 model. For cloud scenes identified by the cloud mask, FARMS is used to compute GHI and FARMS DNI is used to compute the Direct Normal Irradiance (DNI). The PATMOS-X model uses radiance images in visible and infrared channels from the Geostationary Operational Environmental Satellite (GOES) series of geostationary weather satellites. Ancillary variables needed to run REST2 and FARMS (e.g., aerosol optical depth, precipitable water vapor, and albedo) are derived from NASA's Modern Era-Retrospective Analysis (MERRA-2) dataset. Temperature and wind speed data are also derived from MERRA-2 and provided for use in NREL's System Advisor Model (SAM) to compute PV generation.

aerosol↗

National Climate Database (NCDB)

The National Climate Database (NCDB) is a high resolution, bias-corrected climate dataset consisting of the three most widely used variables of solar radiation- global horizontal (GHI), direct normal (DNI), and diffuse horizontal irradiance (DHI)- as well as other meteorological data. The goal of the NCDB is to provide unbiased high temporal and spatial resolution climate data needed for renewable energy modeling. The NCDB is modeled using a statistical downscaling approach with Regional Climate Model (RCM)-based climate projections obtained from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX; linked below). Daily climate projections simulated by the Canadian Regional Climate Model 4 (CanRCM4) forced by the second-generation Canadian Earth System Model (CanESM2) for two Representative Concentration Pathways (RCP4.5 or moderate emissions scenario and RCP8.5 or highest baseline emission scenario) are selected as inputs to the statistical downscaling models. The National Solar Radiation Database (NSRDB) is used to build and calibrate statistical models.

Array↗

OC5 Project Phase Ib: Validation of hydrodynamic loading on a fixed, flexible cylinder for offshore wind applications

This paper summarizes the findings from Phase Ib of the Offshore Code Comparison, Collaboration, Continued with Correlation (OC5) project. OC5 is a project run under the International Energy Agency (IEA) Wind Research Task 30, and is focused on validating the tools used for modelling offshore wind systems through the comparison of simulated responses of select offshore wind systems (and components) to physical test data. For Phase Ib of the project, simulated hydrodynamic loads on a flexible cylinder fixed to a sloped bed were validated against test measurements made in the shallow water basin at the Danish Hydraulic Institute (DHI) with support from the Technical University of Denmark (DTU). The first phase of OC5 examined two simple cylinder structures (Phase Ia and Ib) to focus on validation of hydrodynamic models used in the various tools before moving on to more complex offshore wind systems and the associated coupled physics. As a result, verification and validation activities such as these lead to improvement of offshore wind modelling tools, which will enable the development of more innovative and cost-effective offshore wind designs.

17 WIND ENERGY↗

Dosimetric Parameters in Partial Breast Irradiation Through Brachytherapy

The objective of this work is to evaluate biological models and dose homogeneity in a new partial breast irradiation method, the MammoSite RTS. The study is based on 11 patients who received the therapy. For each patient, we determined the dose volume distribution delivered to the breast. Based on these data, we estimate some important biological parameters. Eleven patients with early-stage, invasive, ductal breast cancer were treated using MammoSite RTS brachytherapy, which delivers radiation through a balloon placed in the lumpectomy bed. The radiation was provided by an Iridium-192 source, and 340 cGy were delivered per fraction twice daily. We calculated some commonly used dosimetric parameters, and evaluated the biological parameters tumor control probability (TCP) and normal tissue complication probability (NTCP). We also looked for correlations among these parameters. The average equivalent uniform dose (EUD), NTCP, and TCP were 43.66 Gy, 47.95%, and 91.78%, respectively. The coefficient of variation (CV) among the patients was very low for all 3 parameters. Two dose homogeneity indices (DHI and the S-index) are strongly correlated (r = -0.815). The area under the dose-volume histogram (DVH) and the treatment volume (TXV) also showed a strong correlation (r = 0.995, p < 0.0001). A simplified logit Poisson-EUD model is suitable for determining NTCP and TCP. Other factors such as the area under the DVH and dose homogeneity indices are also useful in planning radiotherapy treatments for early breast cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

A case report on bilateral partial breast irradiation using SAVI

To assess dosimetric parameters in a case study where bilateral accelerated partial breast irradiation (APBI) is delivered using a strut-adjusted volume implant (SAVI) device. A 59-year-old female received APBI in both breasts over 5 days, with fractions of 3.4 Gy twice daily. A Vac-lok system was used for immobilization, and a C-arm was used for daily imaging. We generated dose-volume histograms (DVHs) for the brachytherapy plans to derive several important biologic factors. We calculated the normal tissue complication probability (NTCP), equivalent uniform dose (EUD), and tumor control probability (TCP) using the Lyman-Kutcher-Burman model parameters {alpha} = 0.3 Gy{sup -1}, {alpha}/{beta} = 4 Gy, n = 0.1, and m = 0.3. In addition, we assessed the dose homogeneity index (DHI), overdose index, and dose nonuniformity ratio. D95 was >95% and V150 was <50 mL for both breasts. The DHIs were 0.469 and 0.512 for the left and right breasts, respectively. The EUDs (normalized to 3.4 Gy b.i.d.) were 33.53 and 29.10 Gy. The TCPs were estimated at 99.2% and 99.9%, whereas the NTCP values were 4.2% and 2.57%. In this clinical case, we were able to quantify the dosimetric parameters of an APBI treatment performed with a SAVI device.

61 RADIATION PROTECTION AND DOSIMETRY↗

Use of physics to improve solar forecast: Part III, impacts of different cloud types

Cloud-type impacts present a great challenge to solar forecasting due to diverse and complex cloud-radiation interactions. This third part of our paper sequence seeks to address this challenge by quantifying the forecast accuracies under eight cloud types: cumulus (Cu), stratified clouds (St), altocumulus (Ac), altostratus (As), cirrostratus/anvil (Cr), cirrus (Ci), congestus (Co), deep convective clouds (Dc) across four physics-informed persistence models reported in Part I. To generalize the cloud impacts, the eight cloud types are further grouped into three cloud categories based on their common features: weak convective clouds, stratiform clouds, and strong convective clouds. Here, the decade-long (2001 ~ 2014) collocated measurements of irradiances and cloud types at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Program South Great Plain (SGP) Central Facility site are used for model evaluation. Results reveal a clear performance hierarchy for global horizontal irradiance (GHI) and direct normal irradiance (DNI): best for weak convective clouds and cirrus, intermediate for stratiform clouds, and worst for strong convective clouds. Performance for diffuse horizontal irradiance (DHI) is less influenced by cloud types. Cloud albedo dominates all three irradiances for Dc, while both cloud albedo and cloud fraction are influential for other cloud types. A 12 %~33 % improvement in accuracy at 6-hour lead time compared to the benchmark smart model confirms the effectiveness of incorporating physics into the models for various cloud types; further improvements are expected by directly integrating cloud type information into forecasting models by modifying the physical formulation of cloud-radiation interaction, and/or using more advanced machine learning models.

14 SOLAR ENERGY↗

Uncertainty of Rotating Shadowband Irradiometers and Si-Pyranometers Including the Spectral Irradiance Error

Concentrating solar power projects require accurate direct normal irradiance (DNI) data including uncertainty specifications for plant layout and cost calculations. Ground measured data are necessary to obtain the required level of accuracy and are often obtained with Rotating Shadowband Irradiometers (RSI) that use photodiode pyranometers and correction functions to account for systematic effects. The uncertainty of Si-pyranometers has been investigated, but so far basically empirical studies were published or decisive uncertainty influences had to be estimated based on experience in analytical studies. One of the most crucial estimated influences is the spectral irradiance error because Si-photodiode-pyranometers only detect visible and color infrared radiation and have a spectral response that varies strongly within this wavelength interval. Furthermore, analytic studies did not discuss the role of correction functions and the uncertainty introduced by imperfect shading. In order to further improve the bankability of RSI and Si-pyranometer data, a detailed uncertainty analysis following the Guide to the Expression of Uncertainty in Measurement (GUM) has been carried out. The study defines a method for the derivation of the spectral error and spectral uncertainties and presents quantitative values of the spectral and overall uncertainties. Data from the PSA station in southern Spain was selected for the analysis. Average standard uncertainties for corrected 10 min data of 2% for global horizontal irradiance (GHI), and 2.9% for DNI (for GHI and DNI over 300 W/m2) were found for the 2012 yearly dataset when separate GHI and DHI calibration constants were used. Also the uncertainty in 1 min resolution was analyzed. The effect of correction functions is significant. The uncertainties found in this study are consistent with results of previous empirical studies.

14 SOLAR ENERGY↗