Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DEPTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fabrication and testing of a newly designed slit system for depth-resolved X-ray diffraction measurements

A new system of slits called `spiderweb slits' have been developed for depth-resolved powder or polycrystalline X-ray diffraction measurements. The slits act on diffracted X-rays to select a particular gauge volume of sample, while absorbing diffracted X-rays from outside of this volume. Although the slit geometry is to some extent similar to that of previously developed conical slits or spiral slits, this new design has advantages over the previous ones in use for complex heterogeneous materials and in situ and operando diffraction measurements. For example, the slits can measure a majority of any diffraction cone for any polycrystalline material, over a continuous range of diffraction angles, and work for X-ray energies of tens to hundreds of kiloelectronvolts. The design is generated and optimized using ray-tracing simulations, and fabricated through laser micromachining. The first prototype was successfully tested at the X17A beamline at the National Synchrotron Light Source, and shows similar performance to simulations, demonstrating gauge volume selection for standard powders, for all diffraction peaks over angles of 2–10°. A similar, but improved, design will be implemented at the X-ray Powder Diffraction beamline at the National Synchrotron Light Source II.

depth-resolved↗

Wave like signatures in aerosol optical depth and associated radiative impacts over the central Himalayan region

Doppler Lidar and Multi-Filter Rotating Shadowband Radiometer (MFRSR) observations are utilized to show wave like signatures in aerosol optical depth (AOD) during daytime boundary layer evolution over the Himalayan region. Fourier analysis depicted 60–80 min periods dominant during afternoon hours, implying that observed modulations could be plausible reason for the AOD forenoon–afternoon asymmetry which was previously reported. Inclusion of wave amplitude in diurnal variation of aerosol radiative forcing estimates showed ~40% additional warming in the atmosphere relative to mean AOD. The present observations emphasize the importance of wave induced variations in AOD and radiation budget over the site.

Aerosol optical depth↗

The Two-Column Aerosol Project: Phase I-Overview and impact of elevated aerosol layers on aerosol optical depth

The Two-Column Aerosol Project (TCAP), conducted from June 2012 through June 2013, was a unique study designed to provide a comprehensive data set that can be used to investigate a number of important climate science questions, including those related to aerosol mixing state and aerosol radiative forcing. The study was designed to sample the atmosphere between and within two atmospheric columns; one fixed near the coast of North America (over Cape Cod, MA) and a second moveable column over the Atlantic Ocean several hundred kilometers from the coast. The U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF) was deployed at the base of the Cape Cod column, and the ARM Aerial Facility was utilized for the summer and winter intensive observation periods. One important finding from TCAP is that four of six nearly cloud-free flight days had aerosol layers aloft in both the Cape Cod and maritime columns that were detected using the nadir pointing second-generation NASA high-spectral resolution lidar (HSRL-2). In addition, these layers contributed up to 60% of the total observed aerosol optical depth (AOD). Many of these layers were also intercepted by the aircraft configured for in situ sampling, and the aerosol in the layers was found to have increased amounts of biomass burning material and nitrate compared to aerosol found near the surface. Lastly, while there was a great deal of spatial and day-to-day variability in the aerosol chemical composition and optical properties, no systematic differences between the two columns were observed.

54 ENVIRONMENTAL SCIENCES↗

Characterization of high energy Xe ion irradiation effects in single crystal molybdenum with depth-resolved synchrotron microbeam diffraction

Microbeam X-ray diffraction experiments were conducted at beam line 34-ID of the Advanced Photon Source (APS) on fission fragment energy Xe heavy ion irradiated single crystal Molybdenum (Mo). Lattice strain measurements were obtained with a depth resolution of 0.7 mu m, which is critical in resolving the peculiar heterogeneity of irradiation damage associated with heavy ion irradiation. Q-space diffraction peak shift measurements were correlated with lattice strain induced by the ion irradiations. Transmission electron microscopy (TEM) characterizations were performed on the as-irradiated materials as well. Nanometer sized Xe bubble microstructures were observed via TEM. Molecular Dynamics (MD) simulations were performed to help interpret the lattice strain measurement results from the experiment. This study showed that the irradiation effects by fission fragment energy Xe ion irradiations can be collaboratively understood with the depth resolved X-ray diffraction and TEM measurements under the assistance of MD simulations. (c) 2015 Elsevier B.V. All rights reserved.

Yun, Di (ORCID:0000000297673214)↗

Direct measurement of the magnetic penetration depth by magnetic force microscopy

We present an experimental approach using magnetic force microscopy for measurements of the absolute value of the magnetic penetration depth λ in superconductors. λ is obtained in a simple and robust way without introducing any tip modeling procedure via direct comparison of the Meissner response curves for a material of interest to those measured for a reference sample. Using a well-characterized Nb film as a reference, we determine the absolute value of λ in a Ba(Fe 0.92 Co 0.08 ) 2 As 2 single crystal and a MgB 2 thin film through a comparative experiment. Our apparatus features simultaneous loading of multiple samples, and allows straightforward measurement of the absolute value of λ in superconducting thin film or single-crystal samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interpretation of the depths of maximum of extensive air showers measured by the Pierre Auger Observatory

To interpret the mean depth of cosmic ray air shower maximum and its dispersion, we parametrize those two observables as functions of the first two moments of the ln A distribution. We examine the goodness of this simple method through simulations of test mass distributions. The application of the parameterization to Pierre Auger Observatory data allows one to study the energy dependence of the mean ln A and of its variance under the assumption of selected hadronic interaction models. We discuss possible implications of these dependences in term of interaction models and astrophysical cosmic ray sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of linear least squares to the analysis of Auger electron spectroscopy depth profiles of plutonium oxides [Application of linear least squares to the analysis of AES depth profiles of plutonium oxides]

In this paper, the application of the linear least squares (LLS) methodology allows for quantitative determination of variation in material composition with depth. LLS fits were applied to decompose and enhance the interpretation of spectra obtained by Auger electron spectroscopy during depth profiles of oxidized plutonium surfaces. By means of the LLS algorithm, chemical state assignments of the Pu P 1 VV/O 45 VV, O KLL, and C KLL Auger transitions were determined and the existence of a subsurface oxycarbide layer was identified, with confirmation of the oxide and metal components provided from comparison to previous measurements of standard samples.

36 MATERIALS SCIENCE↗

Dehydration-driven stress transfer triggers intermediate-depth earthquakes

Intermediate-depth earthquakes (30–300 km) have been extensively documented within subducting oceanic slabs, but their mechanics remains enigmatic. Here in this paper we decipher the mechanism of these earthquakes by performing deformation experiments on dehydrating serpentinized peridotites (synthetic antigorite-olivine aggregates, minerals representative of subduction zones lithologies) at upper mantle conditions. At a pressure of 1.1 gigapascals, dehydration of deforming samples containing only 5 vol% of antigorite suffices to trigger acoustic emissions, a laboratory-scale analogue of earthquakes. At 3.5 gigapascals, acoustic emissions are recorded from samples with up to 50 vol% of antigorite. Experimentally produced faults, observed post-mortem, are sealed by fluid-bearing micro-pseudotachylytes. Microstructural observations demonstrate that antigorite dehydration triggered dynamic shear failure of the olivine load-bearing network. These laboratory analogues of intermediatedepth earthquakes demonstrate that little dehydration is required to trigger embrittlement. We propose an alternative model to dehydration-embrittlement in which dehydration-driven stress transfer, rather than fluid overpressure, causes embrittlement.

58 GEOSCIENCES↗