Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DECOMPRESSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Measurement of the shell decompression in direct-drive inertial-confinement-fusion implosions

Measurement of the effect of adiabat (α) on the shell thickness were performed in direct-drive implosions. When reducing the adiabat of the shell from α = 6 to α = 4:5, the shell thickness was measured to decrease from 75 μm to 60 μm, but when decreasing the adiabat further (α = 1:8), the shell thickness was measured to increase to 75 μm. The measured shell thickness, shell trajectories, neutron bang time, and neutron yield were reproduced by two dimensional simulations that include laser imprint, nonlocal thermal transport, cross-beam energy transfer, and first-principles equation-of-state models. The minimum core size was measured to decrease from 40 μm to 30 μm, consistent with the reduction of the adiabat from α = 6 to α = 1:8. Simulations that neglected imprint reproduced the measured core size of the entire adiabat scan, but signi cantly underestimate the shell thickness for adiabat below ~3. These results show that the decompression of the shell measured for low-adiabat implosions was a result of laser imprint.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nature of polyamorphic transformations in H 2 O under isothermal compression and decompression

In this paper, we report polyamorphic transformations of H 2 O under isothermal compression and decompression at 150 K, observed by in situ x-ray diffraction. Detailed structural information across the transformations among low-, high-, and very high-density amorphs (LDA, HDA, VHDA) reveals the mechanisms, the reversibility, and (dis)continuity of the transformations. During isothermal (de)compression, the polyamorphic transformations are characterized by a sharp and reversible LDA-VHDA transformation, with an HDA-like form (referred to as HDA’) appearing as an intermediate state. The LDA-VHDA transformation is found to occur in two steps: a discontinuous transition between LDA and HDA’ and a continuous change within HDA’ involving structural reconfigurations and finally converging to VHDA. Both LDA and VHDA are found to be structurally stable showing elastic behavior under (de)compression, while HDA’ is structurally unstable. Lastly, possible relations of these observations to low- and high-density liquids are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Percutaneous Decompression of Lumbar Spinal Stenosis with a New Interspinous Device

Objective: This study was designed to evaluate the feasibility of the implantation of a new interspinous device (Falena) in patients with lumbar spinal stenosis. The clinical outcomes and imaging results were assessed by orthostatic MR during an up to 6-month follow-up period. Methods: Between October 2008 and February 2010, the Falena was implanted at a single level in 26 patients (17 men; mean age, 69 (range, 54-82) years) who were affected by degenerative lumbar spinal stenosis. All of the patients were clinically evaluated before the procedure and at 1 and 3 months. Furthermore, 20 patients have completed a 6-month follow-up. Pain was assessed before and after the intervention using the Visual Analogue Scale score and the Oswestry Disability Index questionnaire. Orthostatic MR imaging was performed before the implantation and at 3 months to assess the correlation with the clinical outcome. Results: The mean ODI score decreased from 48.9 before the device implantation to 31.2 at 1 month (p < 0.0001). The mean VAS score decreased from 7.6 before to 3.9 (p < 0.0001) at 1 month and 3.6 at 3 months after the procedure (p = 0.0115). These values were stable at 6 months evaluation. No postimplantation major complications were recorded. MRI evaluation documented in most cases an increased size of the spinal canal area. Similarly a bilateral foraminal area improvement was found. The variation of the intervertebral space height measured on the posterior wall was not significant. Conclusions: In our preliminary experience with the Falena in a small cohort of patients, we obtained clinical and imaging results aligned to those reported with similar interspinous devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystal structure of graphite under room-temperature compression and decompression

Recently, sophisticated theoretical computational studies have proposed several new crystal structures of carbon (e.g., bct-C{sub 4}, H-, M-, R-, S-, W-, and Z-carbon). However, until now, there lacked experimental evidence to verify the predicted high-pressure structures for cold-compressed elemental carbon at least up to 50 GPa. Here we present direct experimental evidence that this enigmatic high-pressure structure is currently only consistent with M-carbon, one of the proposed carbon structures. Furthermore, we show that this phase transition is extremely sluggish, which led to the observed broad x-ray diffraction peaks in previous studies and hindered the proper identification of the post-graphite phase in cold-compressed carbon.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase transformations, microstructural refinement and defect evolution mechanisms in Al-Si alloys under non-hydrostatic diamond anvil cell compression

Non-hydrostatic compression of materials using a diamond anvil cell (DAC) can transform equilibrium microstructure of an alloy to novel, potentially metastable states. In this study, in situ synchrotron X-ray diffraction (XRD) during compression up to 24 GPa and subsequent ex situ, high resolution analytical electron microscopy (AEM) after decompression of an Al-Si alloy provided insight into the crystallographic changes during the compression as well as microstructural refinement, and defect structures caused by such a high pressure compression-decompression process. Pressure resolved in-situ synchrotron XRD was used to detail the phase transformation pathway of the eutectic Si phase in Al-Si alloy, from Si-I → Si-XI → Si-V during compression, and a final transformation predominantly to Si-III after decompression. Using scanning and transmission electron microscopy (S/TEM), site specific analysis of the alloy immediately underneath the anvil contact surface demonstrated a highly complex microstructure. A narrow region of thick amorphous Al oxide interspersed with nanocrystalline grains was found at the top surface. Underneath this Al oxide, while the majority the eutectic Si was transformed into highly-deformed, polycrystalline (PC) Si-III, a complex intermediate layer was discovered at the interface between Al and Si, comprised of a small fraction of Al nanocrystals and a majority of nanocrystalline Si-I. This combination of pressure resolved in-situ synchrotron XRD coupled with subsequent high resolution, electron microscopy resolved the phase transformation as well as non-equilibrium microstructures in a metallic alloy induced by a non-hydrostatic high pressure compression followed by decompression.

36 MATERIALS SCIENCE↗

STZ: A High Quality and High Speed Streaming Lossy Compression Framework for Scientific Data

Error-bounded lossy compression is one of the most efficient solutions to reduce the volume of scientific data. For lossy compression, progressive decompression and random-access decompression are critical features that enable on-demand data access and flexible analysis workflows. However, these features can severely degrade compression quality and speed. To address these limitations, we propose a novel streaming compression framework that supports both progressive decompression and random-access decompression while maintaining high compression quality and speed. Our contributions are three-fold: (1) we design the first compression framework that simultaneously enables both progressive decompression and random-access decompression; (2) we introduce a hierarchical partitioning strategy to enable both streaming features, along with a hierarchical prediction mechanism that mitigates the impact of partitioning and achieves high compression quality—even comparable to state-of-the-art (SOTA) non-streaming compressor SZ3; and (3) our framework delivers high compression and decompression speed, up to 6.7 × faster than SZ3.

Wang, Daoce [University of Nebraska, Omaha]↗

A comparison of segmented abdominopelvic fluid volumes with conventional CT signs of abdominal compartment syndrome in a trauma population

Purpose: To compare the utility of abdominopelvic fluid volume measurements with established computed tomography signs for refractory post-traumatic abdominal compartment syndrome. Methods: This retrospective observational cohort study included 64 consecutive adult trauma patients with preoperative CT and diagnosis of refractory abdominal compartment syndrome requiring decompressive laparotomy at a level I trauma referral center between 2004 and 2014. We hypothesized that abdominal fluid volume measurements would be more predictive of the need for early laparotomy than previously described conventional CT signs of refractory ACS. Abdominopelvic fluid volumes were determined quantitatively using semi-automated segmentation software. The following conventional imaging parameters were recorded: abdominal anteroposterior:transverse ratio (round belly sign); infrahepatic vena cava diameter; distal abdominal aortic diameter; largest single small bowel wall diameter; hydronephrosis, inguinal herniation; and mesenteric and body wall edema. For outcome analysis, patients were stratified into two groups: those who underwent early (< 24 h) and late (≥ 24 h) decompressive laparotomy following CT. Correlation analysis, comparison of means, and multivariate logistic regression were performed. Results: Abdominal fluid volumes (p = 0.001) and anteroposterior:transverse ratio (p = 0.009) were increased and inferior vena cava diameter (p = 0.009) was decreased in the early decompressive laparotomy group. Multivariate analysis including conventional CT variables, fluid volumes, and laboratory values revealed abdominal fluid volumes (p = 0.012; Δ in log odds of 1.002/mL) as the only independent predictor of early decompressive laparotomy. Conclusions: Segmented abdominopelvic free fluid volumes had greater predictive utility for decision to perform early decompressive laparotomy than previously described ACS-related CT signs in trauma patients who developed refractory abdominal compartment syndrome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The high pressure phase transformation behavior of silicon nanowires

Si nanowires of 80–150 nm and 200–250 nm diameter are pressurized up to 22 GPa using a diamond anvil cell. Raman and x-ray diffraction data were collected during both compression and decompression. Electron microscopy images reveal that the nanowires retain a nanowire-like morphology (after high pressure treatment). On compression, dc-Si was observed to persist at pressures up to 19 GPa compared to ~11 GPa for bulk-Si. On decompression, the metallic β-Sn phase was found to be more stable for Si nanowires compared with bulk-Si when lowering the pressure and was observed as low as 6 GPa. For the smallest nanowires studied (80–150 nm), predominately a-Si was obtained on decompression, whereas for larger nanowires (200–250 nm), clear evidence for the r8/bc8-Si phase was obtained. We suggest that the small volume of the individual Si nanowires compared with bulk-Si inhibits the nucleation of the r8-Si phase on decompression. This study shows that there is a size dependence in the high pressure behavior of Si nanowires during both compression and decompression.

36 MATERIALS SCIENCE↗

Predicting hydraulic structure-induced barotrauma in Australian fish species

When fish pass downstream through river infrastructure, such as dams and weirs, barotrauma may occur due to rapid decompression. In severe cases, barotrauma may lead to mortality. Different species likely respond differently to these decompressions. Therefore, to predict barotrauma for a specific species, surrogate species may not be a valid approach, and it may be necessary to examine each species individually. For this study, Australian bass and carp gudgeon were exposed to a range of rapid decompressions using hyper/hypobaric hydro-chambers and examined for injuries and mortality. Rapid decompression data from these two fish species, in addition to previously examined Murray cod and silver perch were evaluated to determine which injuries were highly associated with and likely to predict mortality. Dose-response logistic regressions models were developed for each species to predict injury and mortality over a range of rapid decompressions. These models are valuable for estimating injury and mortality rates for fish passing though river infrastructure and can be applied to specific sites where pressure profiles have been developed. Applying these models to current and future infrastructure can provide important insight into what measures or design alterations may be necessary to reduce negative impacts of infrastructure on fish populations.

Pflugrath, Brett D.↗