Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DATA COLLECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design data package and operating procedures for MSFC solar simulator test facility

Design and operational data for the solar simulator test facility are reviewed. The primary goal of the facility is to evaluate the performance capacibility and worst case failure modes of collectors, which utilize either air or liquid transport media. The facility simulates environmental parameters such as solar radiation intensity, solar spectrum, collimation, uniformity, and solar attitude. The facility also simulates wind conditions of velocity and direction, solar system conditions imposed on the collector, collector fluid inlet temperature, and geometric factors of collector tilt and azimuth angles. Testing the simulator provides collector efficiency data, collector time constant, incident angle modifier data, and stagnation temperature values.

Source record↗

Outdoor flat-plate collector performance prediction from solar simulator test data

This paper describes how collector performance obtained from test data with a simulator can be modified for real-life conditions. The approach taken is to correct the performance data obtained with the simulator for the variable conditions of ambient temperature, wind, incident angle, flow rate, etc., that are encountered in outdoor conditions. Modification of simulator data is accomplished by combining experiment with theory. The technique is demonstrated by application to a spectrally selective and a nonselective type of collector. This kind of modified simulator collector performance data should be valuable in solar systems analyses and for collector performance ranking based on all-day calculated conditions.

Simon, F. F.↗

SMS Software Training Exercise 101: SMS and Janam XP20 Data Entry with PSU Collectors

The LANL Sample Management System (SMS) is a software system written in JAVA that supports record keeping associated with handling of media and samples in the BioWatch program. During this portion of the class the instructor will provide: 1. A general overview of what SMS is, 2. How SMS may be configured, 3. How to launch and log-in to SMS, 4. How to accomplish data entry, 5. How to use the Tracking / Exposure History features, 6. How to use the Tracking / Data View and Edit data view features (a. Specifically cover editing a PSU Collector name).

99 GENERAL AND MISCELLANEOUS↗

A performance evaluation of various coatings, substrate materials, and solar collector systems

An experimental apparatus was constructed and utilized in conjunction with both a solar simulator and actual sunlight to test and evaluate various solar panel coatings, panel designs, and scaled-down collector subsystems. Data were taken by an automatic digital data acquisition system and reduced and printed by a computer system. The solar collector test setup, data acquisition system, and data reduction and printout systems were considered to have operated very satisfactorily. Test data indicated that there is a practical or useful limit in scaling down beyond which scaled-down testing cannot produce results comparable to results of larger scale tests. Test data are presented as are schematics and pictures of test equipment and test hardware.

Dolan, F. J.↗

Solar collector parameter identification from unsteady data by a discrete-gradient optimization algorithm

A discrete-gradient optimization algorithm is used to identify the parameters in a one-node and a two-node capacitance model of a flat-plate collector. Collector parameters are first obtained by a linear-least-squares fit to steady state data. These parameters, together with the collector heat capacitances, are then determined from unsteady data by use of the discrete-gradient optimization algorithm with less than 10 percent deviation from the steady state determination. All data were obtained in the indoor solar simulator at the NASA Lewis Research Center.

Hotchkiss, G. B.↗

Verification test of the MSFC solar simulator using a Honeywell double-covered liquid solar collector

Additional verification data to support the utilization of the MSFC Solar Simulator for testing solar collectors was obtained. The Honeywell double-covered liquid solar collector number 2 for which thermal performance data under natural outdoor conditions had been previously obtained was installed on the Solar Simulator and subjected to a series of eight tests under various conditions of wind flow rate. Although these test conditions were not absolutely identical to those of the outdoor tests, they are considered to be sufficiently representative to provide a basis for an accurate comparative analysis of the data recorded for both test programs.

Shih, K., Sr.↗

Solar Hot-Air System --Memphis, Tennessee

Solar collectors using air as collection medium provide space heating for four-building office complex in Memphis. 98 page report furnishes details on installation, including: description of system; system startup and acceptance-test results; technical data on collector; installation manuals for collectors, air handler and heat-storage unit.

Source record↗

Flat-plate collector performance evaluation. The case for a solar simulation approach

A method is proposed for determining the performance of flat-plate solar collector using a simulated sun. Collector test variables that will help establish the basis for the indoor test facility at the Lewis Research Center are discussed. The use of the indoor testing should permit a standard test for the convenient and accurate determination of collector performance. Preliminary test results are reported as an example of the type of collector performance data to be expected from the simulation approach.

Simon, F. F.↗

Performance after weathering of a liquid solar collector

Results from retesting of liquid solar collector described in "Performance evaluation of liquid collector" (M-FS-23931), after long term exposure to natural weathering indicate no detectable degradation in collector performance and no visable deterioration in appearance of collector. Supporting data and pretest/post test efficiency comparison are included.

Source record↗

Flat-plate collector performance determined experimentally with a solar simulator

The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program is described which includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented. The collector performance obtained with the solar simulator will be correlated with data obtained by conducting tests outdoors at Lewis.

Vernon, R. W.↗

Thermionic converter output as a function of collector temperature

Surprisingly few data are available on the variation of thermionic converter output with collector temperature. In this study the output power density has been measured as a function of collector temperature (at a fixed emitter temperature of 1650 K) for six converters with different electrode combinations. Collector temperatures ranged from 750 to 1100 K. For collector temperatures below 900 K, converters built with sublimed molybdenum oxide collectors gave the best performance.

Stark, G.↗

Analysis and Experimental Tests of a High-Performance Evacuated Tubular Collector

A high-performance collector based on the use of all-glass, evacuated tubular collector elements is described and analyzed, and supporting experimental data presented. The collector operated with excellent efficiency at temperatures high enough to drive existing air conditioning units, and showed good performance under diffuse light and low insolation conditions. Collector efficiency was insensitive to operating temperature, ambient temperature, and wind speed. In addition, air, as well as liquid, can be used as the heat transfer fluid, with no significant performance penalty. While the equations governing the useful energy produced can be cast in a form similar to that for flat plate collectors, several important parameters were unique in a number of respects. The loss coefficient was unusually low, while the flow factor and effective insolation were unusually high.

Beekley, D. C.↗

Wind and structural loads data measured on parabolic trough solar collectors at an operational power plant

Abstract Wind loading is a primary contributor to structural design costs of concentrating solar-thermal power collectors, such as heliostats and parabolic troughs. These structures must resist the mechanical forces generated by turbulent wind, while the reflector surfaces must maintain optimal optical performance. Studying wind-driven loads at a full-scale, operational concentrating solar-thermal power plant provides insights into the wind impact on the solar collector field beyond the capabilities of wind tunnel tests or state-of-the-art simulations. We conducted comprehensive field measurements of the atmospheric turbulent wind conditions and the resulting structural wind loads on parabolic troughs at the Nevada Solar One plant over a two-year period. The measurement setup included meteorological masts and structural load sensors on four trough rows. Additionally, a lidar scanned the horizontal plane above the trough field. In this study, we describe the high-resolution dataset characterizing the complex flow field and resulting structural loads. This first-of-its-kind dataset will enhance the understanding of wind loading on collector structures and will help in designing the next-generation solar collectors and photovoltaic trackers.

14 SOLAR ENERGY↗

Indoor test for thermal performance of the Sunmaster evacuated tube (liquid) solar collector

The test procedures used to obtain the thermal performance data for a solar collector under simulated conditions are presented. Tests included a stagnation test, a time constant test, a thermal efficiency test, an incident angle modifier test, and a hot fill test. All tests were performed at ambient conditions and the transient effect and the incident angle effect on the collector were determined. The solar collector is a water working fluid type.

Source record↗

Automatic Detection of Clear-Sky Periods Using Ground and Satellite Based Solar Resource Data

Solar resource availability and variability are important aspects of monitoring performance of photovoltaic installations. For example, recent degradation studies have highlighted the importance of considering cloud cover when calculation degradation rates. With this in mind, we present a method for optimizing clear sky detection algorithms given only modeled clear sky irradiance and ground-measured irradiance values. This method is tested on global horizontal irradiance (GHI) data from ground collectors at six sites across the US and was trained against clear sky classifications determined from satellite data. Thirty models were optimized on each individual site at GHI data frequencies of 1, 5, 10, 15, and 30 minutes. The models had an average F 0.5 score of 0.945 +/- .021 on a holdout test set. In comparison, the un-optimized clear sky detection algorithm produced F 0.5 score that averaged to 0.707 +/- 0.187.

14 SOLAR ENERGY↗

Indoor and outdoor tests of a liquid solar collector

Two reports describe thermal-performance data obtained on double-covered liquid solar collector. One report describes data obtained during outdoor testing and the other describes indoor test data obtained by using Marshall Space Flight Center solar simulator. Indoor data were taken to verify performance of solar simulator.

Losey, R.↗

Automatic Detection of Clear-Sky Periods From Irradiance Data

Recent degradation studies have illustrated the importance of considering cloud cover when calculating degradation rates, finding more reliable values when the data are restricted to clear sky periods. Several automated methods of determining clear sky periods have been previously developed, but parameterizing and testing the models has been difficult. Here, we use clear sky classifications determined from satellite data to develop an algorithm that determines clear sky periods using only measured irradiance values and modeled clear sky irradiance as inputs. This approach is tested on global horizontal irradiance (GHI) data from ground collectors at six sites across the United States and compared against independent satellite-based classifications. First, 30 separate models were optimized on each individual site at GHI data intervals of 1, 5, 10, 15, and 30 min (sampled on the first minute of the interval). The models had an average F 0.5 score of 0.949 ± 0.035 on a holdout test set. Next, optimizations were performed by aggregating data from different locations at the same interval, yielding one model per data interval. This paper yielded an average F 0.5 of 0.946 ± 0.037. A final, 'universal' optimization that was trained on data from all sites at all intervals provided an F 0.5 score of 0.943 ± 0.040. The optimizations all provide improvements on a prior, unoptimized clear sky detection algorithm that produces F 0.5 scores that average to 0.903 ± 0.067. Our paper indicates that a single algorithm can accurately classify clear sky periods across locations and data sampling intervals.

14 SOLAR ENERGY↗