Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cyber Security Metrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

CPES-QSM: A Quantitative Method Towards the Secure Operation of Cyber-Physical Energy Systems

Power systems are evolving into cyber-physical energy systems (CPES) mainly due to the integration of modern communication and Internet-of-Things (IoT) devices. CPES security evaluation is challenging since the physical and cyber layers are often not considered holistically. Existing literature focuses on only optimizing the operation of either the physical or cyber layer while ignoring the interactions between them. This paper proposes a metric, the Cyber-Physical Energy System Quantitative Security Metric (CPES-QSM), that quantifies the interaction between the cyber and physical layers across three domains: electrical, cyber-risk, and network topology. A method for incorporating the proposed cyber-metric into operational decisions is also proposed by formulating a cyber-constrained AC optimal power flow (C-ACOPF) that considers the status of all the CPES layers. The C-ACOPF considers the vulnerabilities of physical and cyber networks by incorporating factors such as voltage stability, contingencies, graph-theory, and IoT cyber risks, while using a multi-criteria decision-making technique. We note that simulation studies are conducted using standard IEEE test systems to evaluate the effectiveness of the proposed metric and the C-ACOPF formulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Resilient Design Methodology for Microgrids

Recent advancement in tools has helped with microgrid design, development, planning and operation. Microgrids offer a unique application based on users with different requirements for tools. The process of designing, constructing, commissioning, and assessing a microgrid is not always straightforward due to these distinct requirements. Additionally, metrics are needed for performance evaluation. This panel will offer an overview and description of tools that helps with microgrid design, construction, planning, operation, cyber security, and metrics-driven performance assessment driven by multiple diverse applications and use cases.

CCE↗

A Graph-Based Impact Metric for Mitigating Lateral Movement Cyber Attacks

Most cyber network attacks begin with an adversary gain- ing a foothold within the network and proceed with lateral movement until a desired goal is achieved. The mechanism by which lateral movement occurs varies but the basic signa- ture of hopping between hosts by exploiting vulnerabilities is the same. Because of the nature of the vulnerabilities typ- ically exploited, lateral movement is very difficult to detect and defend against. In this paper we define a dynamic reach- ability graph model of the network to discover possible paths that an adversary could take using different vulnerabilities, and how those paths evolve over time. We use this reacha- bility graph to develop dynamic machine-level and network- level impact scores. Lateral movement mitigation strategies which make use of our impact scores are also discussed, and we detail an example using a freely available data set.

cyber security↗

Cryptographic Key Management and Critical Risk Assessment

The Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE) CyberSecurity for Energy Delivery Systems (CSEDS) industry led program (DE-FOA-0000359) entitled "Innovation for Increasing CyberSecurity for Energy Delivery Systems (12CSEDS)," awarded a contract to Sypris Electronics LLC to develop a Cryptographic Key Management System for the smart grid (Scalable Key Management Solutions for Critical Infrastructure Protection). Oak Ridge National Laboratory (ORNL) and Sypris Electronics, LLC as a result of that award entered into a CRADA (NFE-11-03562) between ORNL and Sypris Electronics, LLC. ORNL provided its Cyber Security Econometrics System (CSES) as a tool to be modified and used as a metric to address risks and vulnerabilities in the management of cryptographic keys within the Advanced Metering Infrastructure (AMI) domain of the electric sector. ORNL concentrated our analysis on the AMI domain of which the National Electric Sector Cyber security Organization Resource (NESCOR) Working Group 1 (WG1) has documented 29 failure scenarios. The computational infrastructure of this metric involves system stakeholders, security requirements, system components and security threats. To compute this metric, we estimated the stakes that each stakeholder associates with each security requirement, as well as stochastic matrices that represent the probability of a threat to cause a component failure and the probability of a component failure to cause a security requirement violation. We applied this model to estimate the security of the AMI, by leveraging the recently established National Institute of Standards and Technology Interagency Report (NISTIR) 7628 guidelines for smart grid security and the International Electrotechnical Commission (IEC) 63351, Part 9 to identify the life cycle for cryptographic key management, resulting in a vector that assigned to each stakeholder an estimate of their average loss in terms of dollars per day of system operation. To further address probabilities of threats, information security analysis can be performed using game theory implemented in dynamic Agent Based Game Theoretic (ABGT) simulations. Such simulations can be verified with the results from game theory analysis and further used to explore larger scale, real world scenarios involving multiple attackers, defenders, and information assets. The strategy for the game was developed by analyzing five electric sector representative failure scenarios contained in the AMI functional domain from NESCOR WG1. From these five selected scenarios, we characterized them into three specific threat categories affecting confidentiality, integrity and availability (CIA). The analysis using our ABGT simulation demonstrated how to model the AMI functional domain using a set of rationalized game theoretic rules decomposed from the failure scenarios in terms of how those scenarios might impact the AMI network with respect to CIA.

Advanced Metering Infrastructure↗

Centralized Cryptographic Key Management and Critical Risk Assessment - (CRADA Final Report)

The Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE) Cyber Security for Energy Delivery Systems (CSEDS) industry led program (DE-FOA-0000359) entitled "Innovation for Increasing Cyber Security for Energy Delivery Systems (12CSEDS)," awarded a contract to Sypris Electronics LLC to develop a Cryptographic Key Management System for the smart grid (Scalable Key Management Solutions for Critical Infrastructure Protection). Oak Ridge National Laboratory (ORNL) and Sypris Electronics, LLC as a result of that award entered into a CRADA (NFE-11-03562) between ORNL and Sypris Electronics, LLC. ORNL provided its Cyber Security Econometrics System (CSES) as a tool to be modified and used as a metric to address risks and vulnerabilities in the management of cryptographic keys within the Advanced Metering Infrastructure (AMI) domain of the electric sector. ORNL concentrated our analysis on the AMI domain of which the National Electric Sector Cyber security Organization Resource (NESCOR) Working Group 1 (WG1) has documented 29 failure scenarios. The computational infrastructure of this metric involves system stakeholders, security requirements, system components and security threats. To compute this metric, we estimated the stakes that each stakeholder associates with each security requirement, as well as stochastic matrices that represent the probability of a threat to cause a component failure and the probability of a component failure to cause a security requirement violation. We applied this model to estimate the security of the AMI, by leveraging the recently established National Institute of Standards and Technology Interagency Report (NISTIR) 7628 guidelines for smart grid security and the International Electrotechnical Commission (IEC) 63351, Part 9 to identify the life cycle for cryptographic key management, resulting in a vector that assigned to each stakeholder an estimate of their average loss in terms of dollars per day of system operation. To further address probabilities of threats, information security analysis can be performed using game theory implemented in dynamic Agent Based Game Theoretic (ABGT) simulations. Such simulations can be verified with the results from game theory analysis and further used to explore larger scale, real world scenarios involving multiple attackers, defenders, and information assets. The strategy for the game was developed by analyzing five electric sector representative failure scenarios contained in the AMI functional domain from NESCOR WG1. From these five selected scenarios, we characterized them into three specific threat categories affecting confidentiality, integrity and availability (CIA). The analysis using our ABGT simulation demonstrated how to model the AMI functional domain using a set of rationalized game theoretic rules decomposed from the failure scenarios in terms of how those scenarios might impact the AMI network with respect to CIA.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Performance Computing Facility Operational Assessment, FY 2011 Oak Ridge Leadership Computing Facility

Oak Ridge National Laboratory's Leadership Computing Facility (OLCF) continues to deliver the most powerful resources in the U.S. for open science. At 2.33 petaflops peak performance, the Cray XT Jaguar delivered more than 1.5 billion core hours in calendar year (CY) 2010 to researchers around the world for computational simulations relevant to national and energy security; advancing the frontiers of knowledge in physical sciences and areas of biological, medical, environmental, and computer sciences; and providing world-class research facilities for the nation's science enterprise. Scientific achievements by OLCF users range from collaboration with university experimentalists to produce a working supercapacitor that uses atom-thick sheets of carbon materials to finely determining the resolution requirements for simulations of coal gasifiers and their components, thus laying the foundation for development of commercial-scale gasifiers. OLCF users are pushing the boundaries with software applications sustaining more than one petaflop of performance in the quest to illuminate the fundamental nature of electronic devices. Other teams of researchers are working to resolve predictive capabilities of climate models, to refine and validate genome sequencing, and to explore the most fundamental materials in nature - quarks and gluons - and their unique properties. Details of these scientific endeavors - not possible without access to leadership-class computing resources - are detailed in Section 4 of this report and in the INCITE in Review. Effective operations of the OLCF play a key role in the scientific missions and accomplishments of its users. This Operational Assessment Report (OAR) will delineate the policies, procedures, and innovations implemented by the OLCF to continue delivering a petaflop-scale resource for cutting-edge research. The 2010 operational assessment of the OLCF yielded recommendations that have been addressed (Reference Section 1) and where appropriate, changes in Center metrics were introduced. This report covers CY 2010 and CY 2011 Year to Date (YTD) that unless otherwise specified, denotes January 1, 2011 through June 30, 2011. User Support remains an important element of the OLCF operations, with the philosophy 'whatever it takes' to enable successful research. Impact of this center-wide activity is reflected by the user survey results that show users are 'very satisfied.' The OLCF continues to aggressively pursue outreach and training activities to promote awareness - and effective use - of U.S. leadership-class resources (Reference Section 2). The OLCF continues to meet and in many cases exceed DOE metrics for capability usage (35% target in CY 2010, delivered 39%; 40% target in CY 2011, 54% January 1, 2011 through June 30, 2011). The Schedule Availability (SA) and Overall Availability (OA) for Jaguar were exceeded in CY2010. Given the solution to the VRM problem the SA and OA for Jaguar in CY 2011 are expected to exceed the target metrics of 95% and 90%, respectively (Reference Section 3). Numerous and wide-ranging research accomplishments, scientific support, and technological innovations are more fully described in Sections 4 and 6 and reflect OLCF leadership in enabling high-impact science solutions and vision in creating an exascale-ready center. Financial Management (Section 5) and Risk Management (Section 7) are carried out using best practices approved of by DOE. The OLCF has a valid cyber security plan and Authority to Operate (Section 8). The proposed metrics for 2012 are reflected in Section 9.

99 GENERAL AND MISCELLANEOUS↗

Concept for Cyber-Physical Consequence Process

The Department of Homeland Security’s Office of Cyber and Infrastructure Analysis (DHS/OCIA) has a mission and vision that promotes innovation as central to expanding the organization’s capability to conduct consequence analysis. To pursue such innovation, OCIA is sponsoring a seedling effort with Idaho National Laboratory (INL) to leverage data from the proposed Automated Vulnerability Assessment (AVA) capability, which the DHS Science and Technology (S&T) Directorate is developing through a separate INL effort. The first phase of this effort is to develop a process by which recognized vulnerabilities can be scored relative to importance, reflected primarily in the ability to initiate high consequence and potentially cascading events. This report documents a cyber-physical metrics process (CPMP) to tie physical impact to the malicious exploitation of cyber vulnerabilities in industrial control systems (ICS) with the potential for initiating consequence in the critical infrastructure. The scale of achieving any particular physical consequence is dependent upon the ICS Component the vulnerability exists on, the Level of Access that the exploit would allow to component function and the Physical Impact (CLAPI) to the power system that the component is tied. A modified common vulnerability scoring system (CVSS) was detailed and demonstrated for the power sector with three case studies associated with a recognized vulnerability, with significant consequence detail provided to apply the process across the power sector. A detailed table that provides background on the power system components, ICS-enabled monitoring and control, potential consequence effects, and CVSS scoring is provided. To demonstrate the applicability of the CPMP, tables are provided as examples for other sectors that include chemical, water/wastewater and oil/gas.

42 ENGINEERING↗

ARCADES: analysis of risk from cyberattack against defensive strategies for the power grid

In this study, the authors introduce ARCADES (Analysis of Risk from Cyberattack against DEfensive Strategy), a technique to systematically explore the cybersecurity defence strategies based on contingency rankings in power systems. While cybersecurity defensive standards exist, these approaches are primarily based on expert opinions, rather than systematic studies of risk. ARCADES presents an approach to identify improved cybersecurity defensive strategies based on a graph‐based cyber‐physical security model that is evaluated by resistance‐distance metrics and then prioritised based on contingency analysis studies of the system. This study also proposed a technique that identifies the most critical cybersecurity mechanisms to protect the power grid. Planning and operation: those two applications for cybersecurity on power grid mainly explored in this study. For planning, a systematic method is developed to verify the effectiveness of security strategies and for operation, prioritised the security mechanism for auditing and monitoring purpose. As a case study, they analyse the IEEE‐14 bus, IEEE‐30 bus, and IEEE‐118 bus systems, observe the defensive strategies, and calculate substation criticality ranking by using the authors’ proposed method.

Touhiduzzaman, Md↗

Quantifying Cyber-Resilience Against Resource-Exhaustion Attacks

Resilience in the information sciences is notoriously difficult to define much less to measure. But in mechanical engi- neering, the resilience of a substance is mathematically defined as the area under the stress vs. strain curve. We took inspiration from mechanics in an attempt to define resilience precisely for information systems. We first examine the meaning of resilience in language and engineering terms and then translate these definitions to information sciences. Then we tested our definitions of resilience for a very simple problem in networked queuing systems. We discuss lessons learned and make recommendations for using this approach in future work.

cyber security↗

Cyber Resilient Design and Controls for Energy Systems

As the grid of today is evolving into a highly distributed and autonomous cyber-physical system with higher penetration of Distributed Energy Resources (DERs) and autonomous controls that are dependent on the cyber infrastructure, there are novel and increasing challenges to cyber-resilient operation of the grid. While the traditional mechanisms take a "bolt on" approach to cybersecurity and resiliency, this talk presents two novel technologies developed at NREL that "bake in" security and resilience into the design and control of the grid. An Adaptive Resilience Metrics framework is a novel mechanism for system owners and operators to understand the impact of cyber and physical system design and topology on the resilient operation, while also helping determine optimal policies in response to adverse cyber events. Along with that a zero-knowledge proof-based technique helps incorporate security into the controls layer by focusing on computational integrity rather than data integrity. By leveraging design and control properties unique to Operational Technology systems these technologies will not only help enhance cyber-resilience for the grid of today, but a highly distributed and autonomous grid of tomorrow.

cyber resilience↗

Vulnerability Assessments for Power-Electronics-Based Smart Grids

Here, in this paper, a novel method is proposed to evaluate the cyber security of the power-electronics-based smart grids (PESG). The proposed method considers the performance and stability of both the individual inverter and the grid. To our knowledge, this is a first attempt to evaluate the performance and stability of PESG due to cyber attacks. We first develop impedance-based modeling and cyber-attack modeling for PESG. Then we propose innovative two security criteria to evaluate the security of PESG, including stability-based and metrics-based. For metrics-based criteria, we propose to use both total harmonic distortion (THD) and space phasor model (SPM) to evaluate the inverter performance. The simulation results with a two-inverter-based power grid verify the validity and accuracy of the proposed security evaluation method. Results have shown that the performance and stability of PESG are significantly affected by cyber attacks, and thus there is indeed a need to further study cyber security issues of PESG.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Defining a Metric Space of Host Logs and Operational Use Cases

Host logs, in particular, Windows Event Logs, are a valuable source of information often collected by security operation centers (SOCs). The semi-structured nature of host logs inhibits automated analytics, and while manual analysis is common, the sheer volume makes manual inspection of all logs impossible. Although many powerful algorithms for analyzing time-series and sequential data exist, utilization of such algorithms for most cyber security applications is either infeasible or requires tailored, research-intensive preparations. In particular, basic mathematic and algorithmic developments for providing a generalized, meaningful similarity metric on system logs is needed to bridge the gap between many existing sequential data mining methods and this currently available but under-utilized data source. In this paper, we provide a rigorous definition of a metric product space on Windows Event Logs, providing an embedding that allows for the application of established machine learning and time-series analysis methods. We then demonstrate the utility and flexibility of this embedding with multiple use-cases on real data: (1) comparing known infected to new host log streams for attack detection and forensics, (2) collapsing similar streams of logs into semantically-meaningful groups (by user, by role), thereby reducing the quantity of data but not the content, (3) clustering logs as well as short sequences of logs to identify and visualize user behaviors and background processes over time. Overall, we provide a metric space framework for general host logs and log sequences that respects semantic similarity and facilitates a wide variety of data science analytics to these logs without data-specific preparations for each.

Verma, Miki↗

The Development of a Smart Distribution Grid Testbed for Integrated Information Management Systems

This paper presents a smart distribution grid testbed to test or compare designs of integrated information management systems (I2MSs). An I2MS extracts and synthesizes information from a wide range of data sources to detect abnormal system behaviors, identify possible causes, assess the system status, and provide grid operators with response suggestions. The objective of the testbed is to provide a modeling environment with sufficient data sources for the I2MS design. The testbed includes five information layers and a physical layer; it generates multi-layer chronological data based on actual measurement playbacks or simulated data sets produced by the physical layer. The testbed models random hardware failures, human errors, extreme weather events, and deliberate tampering attempts to allow users to evaluate the performance of different I2MS designs. Initial results of I2MS performance tests showed that the testbed created a close-to-real-world environment that allowed key performance metrics of the I2MS to be evaluated.

99 GENERAL AND MISCELLANEOUS↗

VULCON: A System for Vulnerability Prioritization, Mitigation, and Management

Vulnerability remediation is a critical task in operational software and network security management. In this paper, an effective vulnerability management strategy, called VULCON (VULnerability CONtrol), is developed and evaluated. The strategy is based on two fundamental performance metrics: i). Time-to-Vulnerability Remediation (TVR) and; ii). Total Vulnerability Exposure (TVE). VULCON takes as input real vulnerability scan reports, metadata about the discovered vulnerabilities, asset criticality, and personnel resources. VULCON uses a mixed integer multi-objective optimization algorithm to prioritize vulnerabilities for patching, such that the above performance metrics are optimized subject to the given resource constraints. VULCON has been tested on multiple months of real scan data from a Cyber-Security Operations Center (CSOC). Results indicate an overall Total Vulnerability Exposure reduction of 8.97\% when VULCON optimizes a realistic security analyst workforce's effort. Additionally, it is demonstrated that VULCON can determine monthly resources required to maintain a target TVE score. As such, VULCON provides valuable operational guidance for improving vulnerability response processes in CSOCs.

Farris, Katheryn A.↗

Runtime Analysis with R2U2: A Tool Exhibition Report

We present R2U2 (Realizable, Responsive, Unobtrusive Unit), a hardware- supported tool and framework for the continuous monitoring of safetycritical and embedded cyber-physical systems.With the widespread advent of autonomous systems such as Unmanned Aerial Systems (UAS), satellites, rovers, and cars, real-time, on-board decision making requires unobtrusive monitoring of properties for safety, performance, security, and system health. R2U2 models combine past-time and future-time Metric Temporal Logic, “mission time” Linear Temporal Logic, probabilistic reasoning with Bayesian Networks, and modelbased prognostics. The R2U2 monitoring engine can be instantiated as a hardware solution, running on an FPGA, or as a software component. The FPGA realization enables R2U2 to monitor complex cyber-physical systems without any overhead or instrumentation of the flight software. In this tool exhibition report, we present R2U2 and demonstrate applications on system runtime monitoring, diagnostics, software health management, and security monitoring for a UAS. Our tool demonstration uses a hardware-based processor-in-the-loop “iron-bird” configuration.

Johann Martin Schumann↗

A Review of Cyber-Physical Security for Photovoltaic Systems

In this paper, the challenges and a future vision of the cyber-physical security of photovoltaic (PV) systems are discussed from a firmware, network, PV converter controls, and grid security perspective. The vulnerabilities of PV systems are investigated under a variety of cyber-attacks, ranging from data integrity attacks to software-based attacks. A success rate metric is designed to evaluate the impact and facilitate decision making. Model-based and data-driven methods for threat detection and mitigation are summarized. In addition, the blockchain technology that addresses cyber-attacks in software and cyber networks is described. Simulation and experimental results that show the impact of cyber-attacks at the converter (device) and grid (system) levels are presented. Finally, potential research opportunities are discussed for next-generation, cyber-secure power electronics systems. These opportunities include multi-scale controllability, self-/event-triggering control, artificial intelligence/machine learning, hot patching, and online security. As of today, this study will be one of the few comprehensive studies in this emerging and fast-growing area.

14 SOLAR ENERGY↗

Quantifying the Impact of Unavailability in Cyber-Physical Environments

The Supervisory Control and Data Acquisition (SCADA) system discussed in this work manages a distributed control network for the Tunisian Electric & Gas Utility. The network is dispersed over a large geographic area that monitors and controls the flow of electricity/gas from both remote and centralized locations. The availability of the SCADA system in this context is critical to ensuring the uninterrupted delivery of energy, including safety, security, continuity of operations and revenue. Such SCADA systems are the backbone of national critical cyber-physical infrastructures. Herein, we propose adapting the Mean Failure Cost (MFC) metric for quantifying the cost of unavailability. This new metric combines the classic availability formulation with MFC. The resulting metric, so-called Econometric Availability (EA), offers a computational basis to evaluate a system in terms of the gain/loss ($/hour of operation) that affects each stakeholder due to unavailability.

Availability↗