Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electrospray Thruster Performance with Microfabricated Emitter Arrays and Indium Propellant

The feasibility of a microfabricated indium-fueled electrospray thruster with excellent performance was demonstrated. High efficiency electrospray thrusters with microfabricated components are under development for very compact, distributable propulsion systems that can be employed on both very small and large spacecraft with 10X improvement over SOA in mass, volume and specific impulse The critical components of this technology are the microfabricated emitter arrays and the capillary force driven indium feed system. Grey scale electron-beam lithography patterning and reactive ion dry etching provided the required micron-scale etch precision and uniformity across an array of 400 emitters in 1 cm2. Initial tests of single microfabricated silicon emitters demonstrated better performance than industry standard single emitters and the performance required to achieve 200 micronewtons when scaled up to a thruster with 400 emitters in 1 cm2. Arrays of emitters tested in a preliminary prototype Microfluidic Electrospray Propulsion (MEP) thruster assembly demonstrated stable performance at estimated thrust levels of 5, 50, and 120 µN at extraction voltages less than 4 kV. Current stability was within 0.15 % at 120 µN with only 1.5% of the emitter current collected by the extractor electrode. Post-test inspections revealed that more than 99% of the 400 emitters were electrospraying during the test. Specific impulse was estimated to be >3100 s from measurements of total charge and consumed indium mass at an emitter voltage of 1470 V. The results of this investigation suggest that microfabricated indium electrospray thruster technology is both feasible and capable of excellent performance as a highly compact microthruster.

Marrese-Reading, Colleen M.↗

Integrated circuit electrometer and sweep circuitry for an atmospheric probe

The design of electrometer circuitry using an integrated circuit operational amplifier with a MOSFET input is described. Input protection against static voltages is provided by a dual ultra low leakage diode or a neon lamp. Factors affecting frequency response leakage resistance, and current stability are discussed, and methods are suggested for increasing response speed and for eliminating leakage resistance and current instabilities. Based on the above, two practical circuits, one having a linear response and the other a logarithmic response, were designed and evaluated experimentally. The design of a sweep circuit to implement mobility measurements using atmospheric probes is presented. A triangular voltage waveform is generated and shaped to contain a step in voltage from zero volts in both positive and negative directions.

Zimmerman, L. E.↗

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting↗

Performance measurement of emerging 3- and 4-terminal tandem solar cells

Tandem solar cells are not limited to the conventional two-terminal (2-T) configuration. Multi-terminal designs like three-terminal (3-T) and four-terminal (4-T) devices have gained increasing attention in the PV community due to their relaxed current-matching requirement between subcells and their potential for enhanced energy yield. However, reliable and standardized methods for evaluating the performance of multi-terminal tandems remain underdeveloped. This work addresses this gap by providing comprehensive measurement guidelines tailored to these advanced configurations. We examine key coupling mechanisms between subcells, including the shared electrical load in 3-T devices and optical luminescent coupling in both 3-T and 4-T devices, to enable accurate and consistent performance evaluation. Furthermore, we propose two stabilized measurement methods for emerging 3-T tandem cells incorporating perovskite subcells: (1) a two-dimensional maximum-power-point tracking (MPPT) approach that continuously tracks both subcells' maximum power points (P MAX ) until convergence to stabilized outputs, and (2) a hybrid approach that combines MPPT for one subcell with stabilized current recording under fixed voltage biases near the P MAX of the other, allowing robust extraction of the overall stabilized P MAX (termed “MPPT + asymptotic P MA X scan” method). These methods directly address the dynamic current responses inherent to perovskite-containing tandems, providing a foundation for meaningful and reproducible performance comparisons.

14 SOLAR ENERGY↗

Constraining the Evolution of ZZ Ceti

We report our analysis of the stability of pulsation periods in the DAV star (pulsating hydrogen atmosphere white dwarf) ZZ Ceti, also called R548. On the basis of observations that span 31 years, we conclude that the period 213.13 s observed in ZZ Ceti drifts at a rate dP/dt 5 (5.5 plus or minus 1.9) x 10(exp -15) ss(sup -1), after correcting for proper motion. Our results are consistent with previous P values for this mode and an improvement over them because of the larger time base. The characteristic stability timescale implied for the pulsation period is |P||P(raised dot)|greater than or equal to 1.2 Gyr, comparable to the theoretical cooling timescale for the star. Our current stability limit for the period 213.13 s is only slightly less than the present measurement for another DAV, G117-B15A, for the period 215.2 s, establishing this mode in ZZ Ceti as the second most stable optical clock known, comparable to atomic clocks and more stable than most pulsars. Constraining the cooling rate of ZZ Ceti aids theoretical evolutionary models and white dwarf cosmochronology. The drift rate of this clock is small enough that we can set interesting limits on reflex motion due to planetary companions.

Mukadam, Anjum S.↗

Thermally induced PtOx interfacial layer enhances stability of Pt/β-Ga2O3 vertical Schottky diodes

This study investigates the long-term stability of Pt/β-Ga2O3 field-plated Schottky barrier diodes at high temperatures, with extended thermal cycling and soaking stress. The device characteristics reveal a strong dependence on operating temperature, leading to an ON/OFF current ratio of ∼10× at ±3 V and 600 °C. Extensive thermal cycling (25 cycles over 100 h) between room temperature and 350 °C shows that leakage currents stabilize after the initial ten cycles. This stabilization is likely due to the formation of a thin PtOx layer at the Pt/β-Ga2O3 interface, as confirmed by high-resolution scanning transmission electron microscopy. Further exposure to a constant 350 °C environment for 10 h reveals a slight increase in the leakage current from 10−7 to 10−6 A at −5 V and degradation of the forward current, due to potential thermodynamic instability of the Ohmic contacts. This study provides insights into the changes in the Pt/β-Ga2O3 diode performance with thermal stress, offering a basis for predicting the device’s operational reliability at high temperatures for sensing and power applications.

08 HYDROGEN↗

Development of Low-Toxicity Urine Stabilization for Spacecraft Water Recovery Systems

Wastewater stabilization is an essential component of the spacecraft water cycle. The purpose of stabilizing wastewater is two-fold. First, stabilization prevents the breakdown of urea into ammonia, a toxic gas at high concentrations. Second, it prevents the growth of microorganisms, thereby mitigating hardware and water quality issues due to due biofilm and planktonic growth. Current stabilization techniques involve oxidizers and strong acids (pH=2) such as chromic and sulfuric acid, which are highly toxic and pose a risk to crew health. The purpose of this effort is to explore less toxic stabilization techniques, such as food-grade and commercial care preservatives. Additionally, certain preservatives were tested in the presence of a low-toxicity organic acid. Triplicate 300-mL volumes of urine were dosed with a predetermined quantity of stabilizer and stored for two weeks. During that time, pH, total organic carbon (TOC), ammonia, and turbidity were monitored. Those preservatives that showed the lowest visible microbial growth and stable pH were further tested in a six-month stability study. The results of the six-month study are also included in this paper.

Adam, Niklas↗

Development of Low-Toxicity Wastewater Stabilization for Spacecraft Water Recovery Systems

Wastewater stabilization was an essential component of the spacecraft water cycle. The purpose of stabilizing wastewater was two-fold. First, stabilization prevents the breakdown of urea into ammonia, a toxic gas at high concentrations. Second, it prevents the growth of microorganisms, thereby mitigating hardware and water quality issues due to due biofilm and planktonic growth. Current stabilization techniques involve oxidizers and strong acids (pH=2) such as chromic and sulfuric acid, which are highly toxic and pose a risk to crew health. The purpose of this effort was to explore less toxic stabilization techniques, such as food-grade and commercial care preservatives. Additionally, certain preservatives were tested in the presence of a low-toxicity organic acid. Triplicate 300-mL volumes of urine were dosed with a predetermined quantity of stabilizer and stored for two weeks. During that time, pH, total organic carbon (TOC), ammonia, and turbidity were monitored. Those preservatives that showed the lowest visible microbial growth and stable pH were further tested in a six-month stability study. The results of the six-month study are also included in this paper.

Adam, Niklas↗

Development of a Low Toxicity Urine Pretreatment for Water Recovery in Space

Wastewater stabilization was an essential component of the spacecraft water cycle. The purpose of stabilizing wastewater was two-fold. First, stabilization prevents the breakdown of urea into ammonia, a toxic gas at high concentrations. Second, it prevents the growth of microorganisms, thereby mitigating hardware and water quality issues due to due biofilm and planktonic growth. Current stabilization techniques involve oxidizers and strong acids (pH=2) such as chromic and sulfuric acid, which are highly toxic and pose a risk to crew health. The purpose of this effort was to explore less toxic stabilization techniques, such as food-grade and commercial care preservatives. Additionally, certain preservatives were tested in the presence of a low-toxicity organic acid. Triplicate 300-mL volumes of urine were dosed with a predetermined quantity of stabilizer and stored for two weeks. During that time, pH, total organic carbon (TOC), ammonia, and turbidity were monitored. Those preservatives that showed the lowest visible microbial growth and stable pH were further tested in a six-month stability study. The results of the six-month study are also included in this paper. Additionally, the pretreatment formulations were tested to determine if the pretreated urine could be distilled to remove 85% of the water, as would occur on the ISS. The goal of the pretreatment was to produce no solids in the resulting brine at 85% water recovery.

Adam, Niklas↗

Development of Low-Toxicity Wastewater Stabilization for Spacecraft Water Recovery Systems

Wastewater stabilization was an essential component of the spacecraft water cycle. The purpose of stabilizing wastewater was two-fold. First, stabilization prevents the breakdown of urea into ammonia, a toxic gas at high concentrations. Second, it prevents the growth of microorganisms, thereby mitigating hardware and water quality issues due to due biofilm and planktonic growth. Current stabilization techniques involve oxidizers and strong acids (pH=2) such as chromic and sulfuric acid, which are highly toxic and pose a risk to crew health. The purpose of this effort was to explore less toxic stabilization techniques, such as food-grade and commercial care preservatives. Additionally, certain preservatives were tested in the presence of a low-toxicity organic acid. Triplicate 300-milliliter volumes of urine were dosed with a predetermined quantity of stabilizer and stored for two weeks. During that time, pH, total organic carbon (TOC), ammonia, and turbidity were monitored. Those preservatives that showed the lowest visible microbial growth and stable pH were further tested in a six-month stability study. The results of the six-month study are also included in this paper.

Mitchell, Julie L.↗

Sulfur as a surface passivation for InP

The use of liquid and gas phase sulfur pretreatment of the surface of InP as a way to form a near-ideal passivated surface prior to chemical vapor deposition of SiO2 was investigated. Results of high-frequency and quasi-static capacitance-voltage measurements, as well as enhancement mode insulated gate field-effect transistor (FET) transductance and drain current stability studies, all support the efficacy of this approach for metal-insulator-semiconductor application of this semiconductor. In particular, surface state values in the range of 10 to the 10th to a few 10 to the 11th/sq cm per eV and enhancement mode FET drain current drifts of less than 5 percent over a 12 h test period were measured.

Iyer, R.↗

Preparation of 1,3-Dihydroxyphenazine

The ability to effectively store energy produced by intermittent renewable sources is a critical challenge for chemists and materials scientists. Redox flow batteries (RFB), which generate current by the flow of electrons between dissolved redox active compounds in separate solutions, are envisioned as a method to store renewable energy at the electrical grid scale. The best known examples of RFBs are driven by redox active metal or main group complexes. Within the past decade, redox active organic molecules have begun to be used in the construction of RFBs with high cell potential and cycle stability, at economical price points. Of particular interest are substituted dihydroxy phenazines, a class of heterocycles, that have recently been used as an anolyte for aqueous organic RFBs. Recent work indicates that different regioisomers of dihydroxyphenazine show dramatically different solubility and stability under electrochemical cycling conditions. Of particular interest was 1,3-dihydroxyphenazine (1,3-DHP), which showed greater than 1.5 M solubility in 2M KOH and excellent electrochemical stability. Current methods of producing 1,3-DHP, however, are low yielding and cumbersome. In the article proposal that follows, we offer an improved method of producing 1,3-DHP at high purity and moderate yield. The method detailed below was used by the Materials Engineering Research Facility (MERF) at Argonne National Lab to deliver more than 1.5 kg of this compound for use in the construction of aqueous organic RFBs.

Dzwiniel, Trevor [Argonne National Laboratory (ANL↗

A long-baseline method for HST gyro drift rate bias calibration

The routine on-orbit calibration of the Hubble Space Telescope (HST) rate gyro assemblies (RGA's) has depended on several related algorithms for drift rate bias calibration. The gyros have exhibited time-varying biases, which must be regularly corrected to maintain pointing stability. Currently, gyro drift parameters are uplinked to the spacecraft every 1-2 days for low rate mode and every 7 days for high rate mode. In order to minimize the impact of frequent calibrations on the HST science schedule, we have refined the gyro calibration algorithms and data collection schemes to reduce the amounts of telemetry data and processing time required for accurate bias calibration. We present a review of the evolution of the gyro calibration algorithms, with particular attention to what we have called the long-baseline bias (LBBIAS) technique, and describe the relative success of these methods in maintaining spacecraft stability.

Boia, John J.↗

Fiber-Coupled Planar Light-Wave Circuit for Seed Laser Control in High Spectral Resolution Lidar Systems

Precise laser remote sensing of aerosol extinction and backscatter in the atmosphere requires a high-power, pulsed, frequency doubled Nd:YAG laser that is wavelength- stabilized to a narrow absorption line such as found in iodine vapor. One method for precise wavelength control is to injection seed the Nd:YAG laser with a low-power CW laser that is stabilized by frequency converting a fraction of the beam to 532 nm, and to actively frequency-lock it to an iodine vapor absorption line. While the feasibility of this approach has been demonstrated using bulk optics in NASA Langley s Airborne High Spectral Resolution Lidar (HSRL) program, an ideal, lower cost solution is to develop an all-waveguide, frequency-locked seed laser in a compact, robust package that will withstand the temperature, shock, and vibration levels associated with airborne and space-based remote sensing platforms. A key technology leading to this miniaturization is the integration of an efficient waveguide frequency doubling element, and a low-voltage phase modulation element into a single, monolithic, planar light-wave circuit (PLC). The PLC concept advances NASA's future lidar systems due to its compact, efficient and reliable design, thus enabling use on small aircraft and satellites. The immediate application for this technology is targeted for NASA Langley's HSRL system for aerosol and cloud characterization. This Phase I effort proposes the development of a potassium titanyl phosphate (KTP) waveguide phase modulator for future integration into a PLC. For this innovation, the proposed device is the integration of a waveguide-based frequency doubler and phase modulator in a single, fiber pigtail device that will be capable of efficient second harmonic generation of 1,064-nm light and subsequent phase modulation of the 532 nm light at 250 MHz, providing a properly spectrally formatted beam for HSRL s seed laser locking system. Fabrication of the integrated PLC chip for NASA Langley, planned for the Phase II effort, will require full integration and optimization of the waveguide components (SHG waveguide, splitters, and phase modulator) onto a single, monolithic device. The PLC will greatly reduce the size and weight, improve electrical- to-optical efficiency, and significantly reduce the cost of NASA Langley s current stabilized HSRL seed laser system built around a commercial off-the-shelf seed laser that is free-space coupled to a bulk doubler and bulk phase modulator.

Cook, Anthony↗

Heavy-ion production of 77 Br and 76 Br

Many radioisotopes with potential medical applications are difficult to produce routinely, especially those on the proton-rich side of the valley of stability. Current production methods typically use light-ion (protons or deuteron) reactions on materials of similar mass to the target radioisotope, which limits the elemental target material available and may require the use of targets with poor thermal properties (as is the case for the production of radiobromine). These reactions may also create significant amounts of proton-rich decay products which require chemical separation from the desired product in a highly radioactive environment. A promising alternative method using heavy-ion fusion-evaporation reactions for the production of the medically relevant bromine radioisotopes 76 Br (t 1/2 = 16.2 h) and 77 Br (t 1/2 = 57.0 h) is presented. Heavy-ion beams of 28 Si and 16 O were used to bombard natural chromium and copper targets just above the Coulomb barrier at the University of Notre Dame's Nuclear Science Laboratory to produce these bromine and precursor radioisotopes by fusion-evaporation reactions. Production yields for these reactions were measured and compared to PACE4 calculations. In addition to using more robust targets for irradiation, a simple physical–chemical separation method is proposed that will lead to very high radiopurity yields. A summary of accelerator facility requirements needed for routine production of these radioisotopes is also presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Voltage bias stress effects in metal halide perovskites are strongly dependent on morphology and ion migration pathways

The solar-to-power power conversion efficiencies (PCEs) of metal halide perovskites (MHP) have improved over the last decade using a wide variety of methods, including composition manipulation, dopant introduction, and interfacial buffers. These methods, however, have taken little regard for the electronic and interfacial effects such alterations may cause within devices under voltage bias stress – a condition required for most device operation. We investigate how halide and cation substitution in MHP structures [specifically, CH 3 NH 3 PbI 2.87 Cl 0.13 and Cs 0.1 (MA 0.17 FA 0.83 ) 0.9 Pb(I 0.83 Br 0.17 ) 3 ] effects the current behavior of devices while under a range of voltage bias stress in both light and dark conditions. Additionally, conducting in depth investigations into the electronic and morphological differences between these two MHP devices, we confirmed their unique voltage bias stress effects are due to intrinsic behavior within the perovskite structure. Importantly, we also determined how crystallite orientation can influence ion migration and therefore alter charge transport and current stability in MHP photovoltaic devices.

36 MATERIALS SCIENCE↗

Structure–performance relationships of lithium-ion battery cathodes revealed by contrast-variation small-angle neutron scattering

Lithium-ion battery cathodes are porous composites of active material, conductive carbon, and polymer binder. Controlling the cathode microstructure is key to achieving high energy density and cycling stability. Current characterization techniques lack the nanoscale resolution over representative volumes necessary to relate cathode microstructure to cycling performance. To address this challenge, we utilize contrast-variation small-angle neutron scattering to quantify the chemical and structural features of cathodes wet by dimethyl carbonate, representing a relevant solvent environment. Using neutron scattering measurements, we identify an expansion in carbon and polymer structures that arises after calendering and wetting with solvent. Further, we deconvolute the carbon and binder phases to obtain the solvent-accessible carbon black surface area, which we correlate to diminished capacity retention driven by electrolyte decomposition on exposed carbon. This technique provides nanoscale insight into composite cathode microstructures and resulting cycling performance, promising future applications to a broad range of porous materials that exist in energy storage systems.

25 ENERGY STORAGE↗