Current Density Regulated Atomic to Nanoscale Process on Li Deposition and Solid Electrolyte Interphase Revealed by Cryogenic Transmission Electron Microscopy

Current density has been perceived to play a critical rule for controlling Li deposition morphology and solid electrolyte interphase (SEI). However, the atomic level mechanism of current density on Li deposition and the SEI remains unclear. In this work, based on cryogenic transmission electron microscopy imaging combined with energy dispersive X-ray spectroscopy and electron energy loss spectroscopy electronic structure analyses, we reveal the atomic level correlation of Li deposition morphology and SEI with current density. We discover that increasing current density leads to increased overpotential for Li nucleation and growth, leading to the transition from growth-limited to nucleation-limited mode for Li dendrite. Independence of current density, the electrochemically deposited Li metal (EDLi) exhibits crystalline whisker-like morphology. The SEI formed at low current density (0.1 mA cm -2 ) is monolithic amorphous; while, a current density of above 2 mA cm -2 leads to a mosaic structured SEI, featuring an amorphous matrix with Li 2 O and LiF dispersoids, and the thickness of the SEI increases with the increase of current density. Uniquely, the Li 2 O particles is spatially located at the top surface of the SEI, while LiF is spatially adjacent to the Li-SEI interface. These results highlight the possible tuning of crucial structural and chemical features of EDLi and SEI through altering deposit conditions and consequently direct correlation with electrochemical performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Hot-wire Circuit with Very Small Time Lag

A circuit for a hot-wire anemometer for the measurement of fluctuating flow is presented in the present report. The principal elements of the circuit are a Wheatstone bridge, one branch of which is the hot wire; and an electronic amplifier and a current regulator for the brief current which in combination maintain the bridge balance constant. Hence the hot wire is kept at practically constant resistance and temperature, and the time lag caused by thermal inertia of the wire is thereby reduced. Through the addition of a nonlinear amplifying stage the reading of the instrument has been rendered proportional to the velocity. A discussion of certain characteristics of the circuit and the results of related calibrating tests are given.

Weske, John R↗

Field oriented control of an induction machine in a high frequency link power system

A field-oriented controlled induction machine drive operating with a high-frequency single-phase sinusoidal voltage link is presented. System performance is investigated by computer simulation and is verified by a test on a prototype system. A novel control loop to minimize the link voltage fluctuation is proposed. The capability of rapid demagnetization of the induction machine by current regulation is investigated. A current-modulation technique termed mode control is proposed, and its performance is compared with that of the conventional delta-modulation technique.

Sul, Seung K.↗

Closed loop dynamics of in-core thermionic reactor systems.

Use of a point model of an in-core thermionic converter to investigate alternative schemes for providing closed-loop reactor control. It was found that schemes based on variable-gain power regulation buffers which use the reactor current as the control variable provide complete protection from thermionic burnout and also provide a virtually constant voltage to the user. A side benefit is that the emitter temperature transients are small; even for a complete electric load drop the emitter temperature transient is less than 100 K. The current regulation scheme was selected for further study with a distributed parameter model which was developed to account for variations in thermionic and heat transfer properties along the length of a cylindrical converter. It was found that, even though the emitter temperature distribution is about 200 K along the converter length, the dynamic properties are unchanged when using the current control scheme.

Sawyer, C. D.↗

Closed-loop Dynamics of In-core Thermionic Reactor Systems

Using a point model of an in-core thermionic converter, alternative schemes for providing closed loop reactor control were investigated. It was found that schemes based on variable gain power regulation buffers which use the reactor current as the control variable provide complete protection from thermionic burnout and also provide a virtually constant voltage to the user. A side benefit is that the emitter temperature transients are small-even for a complete electric load drop the emitter temperature transient is less than 100 deg K. The current regulation scheme was selected for further study with a distributed parameter model which was developed to account for variations in thermionic and heat transfer properties along the length of a cylindrical converter. It was found that even though the emitter temperature distribution is about 200 deg K along the converter length, the dynamic properties are unchanged when using the current control scheme.

Sawyer, C. D.↗

Filtering and Control of High Speed Motor Current in a Flywheel Energy Storage System

The NASA Glenn Research Center has been developing technology to enable the use of high speed flywheel energy storage units in future spacecraft for the last several years. An integral part of the flywheel unit is the three phase motor/generator that is used to accelerate and decelerate the flywheel. The motor/generator voltage is supplied from a pulse width modulated (PWM) inverter operating from a fixed DC voltage supply. The motor current is regulated through a closed loop current control that commands the necessary voltage from the inverter to achieve the desired current. The current regulation loop is the innermost control loop of the overall flywheel system and, as a result, must be fast and accurate over the entire operating speed range (20,000 to 60,000 rpm) of the flywheel. The voltage applied to the motor is a high frequency PWM version of the DC bus voltage that results in the commanded fundamental value plus higher order harmonics. Most of the harmonic content is at the switching frequency and above. The higher order harmonics cause a rapid change in voltage to be applied to the motor that can result in large voltage stresses across the motor windings. In addition, the high frequency content in the motor causes sensor noise in the magnetic bearings that leads to disturbances for the bearing control. To alleviate these problems, a filter is used to present a more sinusoidal voltage to the motor/generator. However, the filter adds additional dynamics and phase lag to the motor system that can interfere with the performance of the current regulator. This paper will discuss the tuning methodology and results for the motor/generator current regulator and the impact of the filter on the control. Results at speeds up to 50,000 rpm are presented.

Kenny, Barbara H.↗

Derivation of linearized transfer functions for switching-mode regulations. Phase A: Current step-up and voltage step-up converters

Small-signal models are derived for the power stage of the voltage step-up (boost) and the current step-up (buck) converters. The modeling covers operation in both the continuous-mmf mode and the discontinuous-mmf mode. The power stage in the regulated current step-up converter on board the Dynamics Explorer Satellite is used as an example to illustrate the procedures in obtaining the small-signal functions characterizing a regulated converter.

Wong, R. C.↗

A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance

The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.

14 SOLAR ENERGY↗

Arcjet component conditions through a multistart test

A low power, dc arcjet thruster was tested for starting reliability using hydrogen-nitrogen mixtures simulating the decomposition products of hydrazine. More than 300 starts were accumulated in phases with extended burn-in periods interlaced. A high degree of flow stabilization was built into the arcjet and the power supply incorporated both rapid current regulation and a high voltage, pulsed starting circuit. A nominal current level of 10 A was maintained throughout the test. Photomicrographs of the cathode tip showed a rapid recession to a steady-state operating geometry. A target of 300 starts was selected, as this represents significantly more than anticipated (150 to 240), in missions of 10 yr or less duration. Weighings showed no apparent mass loss. Some anode erosion was observed, particularly at the entrance to the constrictor. This was attributed to the brief period during startup the arc mode attachment point spends in the high pressure region upstream of the nozzle. Based on the results obtained, startup does not appear to be performance or life limiting for the number of starts typical of operational satellite applications.

Curran, Frank M.↗

Arcjet component conditions through a multistart test

A low power, dc arcjet thruster was tested for starting reliability using hydrogen-nitrogen mixtures simulating the decomposition products of hydrazine. More than 300 starts were accumulated in phases with extended burn-in periods interlaced. A high degree of flow stabilization was built into the arcjet and the power supply incorporated both rapid current regulation and a high voltage, pulsed starting circuit. A nominal current level of 10 A was maintained throughout the test. Photomicrographs of the cathode tip showed a rapid recession to a steady-state operating geometry. A target of 300 starts was selected, as this represents significantly more than anticipated (150 to 240), in missions of 10 yr or less duration. Weighings showed no apparent mass loss. Some anode erosion was observed, particularly at the entrance to the constrictor. This was attributed to the brief period during startup the arc mode attachment point spends in the high pressure region upstream of the nozzle. Based on the results obtained, startup does not appear to be performance or life limiting for the number of starts typical of operational satellite applications.

Curran, Frank M.↗

Comparison of Side-on Peak Overpressure Predictions and Measurements for Type IV Composite Overwrapped Pressure Vessel Catastrophic Failure

This development of empirical data to support realistic and science-based input to safety regulations and transportation standards is a critical need for the hazardous material (HM) transportation industry. Current regulations and standards are based on the TNT equivalency model. However, real world experience indicates that use of the TNT equivalency model to predict composite overwrapped pressure vessel (COPV) potential energy release is unrealistically conservative. The purpose of this report is to characterize and quantify rupture events involving damaged COPV’s of the type used in HM transportation regulated by the Department of Transportation (DOT). This was accomplished using a series of five tests; 2 COPV tests for compressed natural gas (CNG), 2 COPV tests for hydrogen, and 1 COPV test for nitrogen. Measured overpressures from these tests were compared to predicted overpressures from a TNT equivalence model and blast curves. Comparison between the measurements and predictions shows that the predictions are generally conservative, and that the extent of conservatism is dominated by predictions of the chemical contribution to overpressure from fuel within the COPVs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The 5-kW arcjet power electronics

The initial design and evaluation of a 5 kW arcjet power electronics breadboard which as been integrated with a modified 1 kW design laboratory arcjet is presented. A single stage, 5 kW full bridge, pulse width modulated (PWM), power converter was developed which was phase shift regulated. The converter used metal oxide semiconductor field effect transistor (MOSFET) power switches and incorporated current mode control and an integral arcjet pulse ignition circuit. The unoptimized power efficiency was 93.5 and 93.9 percent at 5 kW and 50A output at input voltages of 130 and 150V, respectively. Line and load current regulation at 50A output was within one percent. The converter provided up to 6.6 kW to the arcjet with simulated ammonia used as a propellant.

Gruber, R. P.↗

5-kW arcjet power electronics

The initial design and evaluation of a 5 kW arcjet power electronics breadboard which as been integrated with a modified 1 kW design laboratory arcjet is presented. A single stage, 5 kW full bridge, pulse width modulated (PWM), power converter was developed which was phase shift regulated. The converter used metal oxide semiconductor field effect transistor (MOSFET) power switches and incorporated current mode control and an integral arcjet pulse ignition circuit. The unoptimized power efficiency was 93.5 and 93.9 percent at 5 kW and 50A output at input voltages of 130 and 150V, respectively. Line and load current regulation at 50A output was within one percent. The converter provided up to 6.6 kW to the arcjet with simulated ammonia used as a propellant.

Gruber, R. P.↗

Headquarters summary reports

The status is summarized of the NASA sponsored involvement in high speed civil transport research and technology, including major cooperative efforts. That involvement is currently focussed on the High Speed Research Program. The program goals are an acceptable level of ozone depletion or sonic boom, the definition of which is a regulatory and political process. The HSRP goal is to provide technical bases for acceptability criteria. Community noise is currently regulated, and it seems clear that HSCT aircraft will have to comply with at least the spirit of the current subsonic constraint, FAR 36, Stage 3.

Source record↗

Federal Oversight of Hydrogen Systems

The application of hydrogen as an energy carrier has been expanding into industrial and transportation sectors enabling sustainable energy resources and providing a zero-emission energy infrastructure. The hydrogen supply infrastructure includes processes from production and storage, to transportation and distribution, to end use. Each portion of the hydrogen supply infrastructure is regulated by international, federal, state, and local entities. Regulations are enforced by entities which provide guidance and updates as necessary. While energy sources such as natural gas are currently regulated via the Code of Federal Regulations and United States Code, there might be some ambiguity as to which regulations are applicable to hydrogen and where regulatory gaps may exist. This report contains an overview of the regulations that apply to hydrogen, and those that may indirectly cover hydrogen as an energy carrier participating in a sustainable zero emission global energy system. As part of this effort, the infrastructure of hydrogen systems and regulation enforcement entities are defined, and a visual map and reference table are developed. This regulatory map and table can be used to identify the boundaries of federal oversight for each component of the hydrogen supply value chain which includes production, storage, distribution, and use.

08 HYDROGEN↗

Impedance sources (Z sources) with inherent fault protection for resilient and fire-free electricity grids

Modern societies would not survive without electricity and at the same time electrical faults could cause and have caused many catastrophes—mainly deadly fires—to our societies. There are two types of electricity sources: the voltage source such as generators, charged batteries and capacitors, and the current source such as charged inductors, current-regulated rectifiers, and superconducting magnetic energy storage. An “ideal” voltage source—that is often-sought-or-intentionally engineered—generates a constant voltage irrespective of its load current, and an “ideal” current source injects a constant current irrespective of its load voltage. However, two problems exist: (1) voltage or current sources do not represent many emerging natural/renewable energy sources such as wind turbine generators, photovoltaic cells, and fuel cells, whose output voltage and current are strongly dependent on each other, and (2) a short-circuit fault to an artificially-made and controlled “ideal” voltage source or an open-circuit fault to an “ideal” current source can cause catastrophic failures of the source itself and its surrounding circuits due to large (theoretically infinite) short-circuit current or open-circuit voltage. Here we introduce an impedance source concept to represent, characterize, and model those electricity sources whose output voltage and current are strongly dependent on each other. First, we found that many electric sources with no feedback (or active) control of their output voltage and/or current are a natural impedance source with inherent fault protection at short-circuit or open-circuit faults. Second, any electrical source can be artificially controlled to mimic a natural impedance source. Finally, we show how to apply natural impedance sources and nature-mimicking artificially-controlled sources to the electricity grid—the most complex machine ever made by human beings—to realize electricity grids that are naturally stable, self-protected against electrical faults, and resilient to natural and human-made events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Current-limiting voltage regulator

Voltage regulator, which operates within preset current limits, acts as a circuit breaker to prevent overload failure, and automatically resets when the overload is removed. The power dissipated in the series transistor of the circuit is constant from normal load to short circuit condition.

Cleveland, E. F.↗