Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Faraday-effect polarimetry for current profile measurement in the tokamak plasma edge

Toroidal current profile measurements in the tokamak plasma edge are critical for fusion plasma physics research and model validation. A three-wave Faraday-effect polarimeter-interferometer with a sub-centimeter spatial resolution is proposed on the DIII-D tokamak to determine the edge current profile via Abel inversion. By using probe beams with 316 µm wavelength, a low-field-side, vertical-view, single-pass optical layout covering the plasma edge region (R = 2.15–2.27 m) is assessed. Measurements with no greater than 0.1° polarimetric systematic uncertainty, no greater than 0.01° polarimetric root-mean-square noise (1 kHz bandwidth), and a 0.8 cm radial chord spacing are considered feasible based on the achieved performance of existing systems using similar wavelengths on fusion devices. Furthermore, synthetic diagnostic calculations taking various factors into account, such as diagnostic uncertainty and quality of magnetic flux surfaces, find that the edge current profile can be determined with up to 0.12 MA/m 2 uncertainty, or about 10% of the peak current density in the pedestal of an investigated high-confinement plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extremum Seeking-Based Control System for Particle Accelerator Beam Loss Minimization

Particle accelerators throughout the world vary widely in terms of age and availability of advanced noninvasive diagnostics that provide varying levels of detail about the accelerated beams. Additionally, beam loss measurements and current monitors are ubiquitous in the accelerator community, they are noninvasive, and they are some of the most important metrics in terms of preventing damage or irradiation of beam pipes and equipment for high-energy machines. However, beam loss and current measurements are difficult to use for feedback tuning because of a lack of a known analytic relationship between scalar loss measurements throughout an accelerator and the hundreds of thousands of parameters that influence the beam and time variation of the beam source itself. In this work, we present a model-independent extremum seeking (ES) controller, which has been implemented for automated tuning and optimization of the Los Alamos Neutron Science Center (LANSCE) linear ion accelerator based only on scalar quantities, such as beam loss or flux measurements. We demonstrate the approach on various accelerator subsystems, including groups of radio frequency (RF) accelerating cavities, quadrupole magnets, bending magnets, and steering magnets. This tool is now available as a use graphical user interface (GUI) in the LANSCE control room, allowing beam physicists to choose arbitrary groups of parameters and beam loss or current monitors for adaptive tuning.

43 PARTICLE ACCELERATORS↗

A Half-Bridge On-State Voltage Sensor for In-Situ Measurements

Current prognostics for life expectancy of power semiconductors utilize off-line measurements of the on-state resistance. Presented is a half-bridge (HB) on-state voltage (VON) sensor capable of being utilized for in-situ measurements enabling continuous and real-time monitoring of the on-state resistance. The design provides a single VON measurement output that contains independent VON information of both high and low side devices in a HB leg. The measurement output is referenced from the middle point of the HB and combines the two complementary VON sensing outputs. This system reduces the number of components, required number of analog signal processing circuits, and ADC channels for in-situ health monitoring of a power electronics system. These reductions will facilitate integration of the VON sensor with the gate driver board and achieve low system profile. The experimental results demonstrate the proposed VON measurements while switching with inductive and resistive loads.

Roy, Chondon↗

Low-Power, Flexible Sensor Arrays with Solderless Board-to-Board Connectors for Monitoring Soil Deformation and Temperature: Supporting Data

This dataset was used to assess the potential of a Soil Deformation and Temperature Monitoring System developed and presented in the article named "Low-Power, Flexible Sensor Arrays with Solderless Board-to-Board Connectors for Monitoring Soil Deformation and Temperature" and published in Sensors. There are 21 comma-delimited data files (.csv). 14 files contain current measurements performed in a lab setting, enabling the electrical evaluation of the sensor probe. These files are generated by the Keithley DMM6500 multimeter, and list the measured supply current (first column) as a function of time (3rd column). Another set of 6 files is also acquired in lab experiments, but contain soil temperature an deformation measurements, enabling an assessment of the developed device's accuracy. In these files, the first column contains the time (UTC), followed by the sensor's battery voltage and temperature and acceleration values (X, Y, Z) in subsequent columns. The measurements were acquired every 5 seconds. Another .csv file contains field data in a similar format (time, temperature, acceleration) collected at the Teller road (mile 27) site near Nome, Alaska with one probe. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Measuring magnetic fields in laser-driven coils with dual-axis proton deflectometry

Abstract By driving hot electrons between two metal plates connected by a wire loop, high power lasers can generate multi-tesla, quasi-static magnetic fields in miniature coil targets. Many experiments involving laser-coil targets rely on proton deflectometry directed perpendicular to the coil axis to extract a measurement of the magnetic field. In this paper, we show that quantitative measurements using perpendicular probing are complicated by the presence of GV m −1 electric fields in the target that develop on sub-ns timescales. Probing parallel to the coil axis with fiducial grids is shown to reliably separate the electric and magnetic field measurements, giving current estimates of I ≈ 5 kA in 1 mm- and 2 mm-diameter wire loops. An analytic model of proton deflection in electric and magnetic fields is used to benchmark results from the particle-in-cell code and help deconvolve the magnetic and electric field deflections. Results are used to motivate a new experimental scheme that combines a single-plate target with axial proton probing and direct current measurements. This scheme has several important advantages over the traditional target and diagnostic set-up, enabling the robust measurement of coil magnetic fields and plasma properties, as well as making it easier to validate different theoretical models at a range of laser intensities.

Bradford, P. (ORCID:0000000296186342)↗

Development of High-Temperature Bonding Techniques to Enable High-Temperature Static or Dynamic Strain Measurements

Current light-water nuclear reactors rely on a variety of different sensors and sensor applications to meet their structural health monitoring needs throughout the entirety of the reactor primary, secondary, and containment systems. Optical fiber–based sensor technologies could provide solutions to reduce the sensor system footprint while enhancing the measurement fidelity and spatial resolution by leveraging distributed monitoring techniques. Moreover, advanced reactors may require optical fiber–based sensors for structural health monitoring because their operating temperatures will exceed the limits of conventional transducers used to acquire dynamic strain or acoustic data in nuclear power plants. Therefore, this report describes experiments targeting the development of high-temperature bonding techniques that would allow for potentially long lengths of fibers to be bonded to metallic reactor components in advanced reactor systems. The high temperatures experienced within target application, next-generation nuclear reactors, necessitate a high-temperature resistant bond to limit the amount of tension on the fiber at the target application temperature. The primary bonding method investigated in this work is brazing; hot-rolling has also been investigated to a lesser extent. Both techniques are well-suited to bonding optical fibers to large reactor components such as primary coolant piping, pressure vessels, or heat exchangers. Optical frequency domain reflectometry was used to monitor the strain in metal-coated optical fibers before, during, and after the high-temperature bonding process. On select optical fibers that were successfully bonded, additional thermal cycling was performed to assess the extent to which the fiber remained bonded based on the expected thermal expansion of the test specimen material. The results of the various experiments yielded the following general conclusions: (1) brazing is a viable technique for bonding and allows significant compressive strain to be applied to the fiber at room temperature; (2) hot-rolling is a viable technique as well, which has been more optimized than the brazing technique for bonding, but less residual compressive strain has been observed with this technique; and (3) both techniques will need further development and optimization to demonstrate bonding of a long length of fiber that can provably operate at relevant temperatures for an advanced nuclear reactor application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Plating and Stripping of Lithium Metal Stabilized by a Block Copolymer Electrolyte: Local Current Density Measurement and Modeling

Here, plating and stripping of lithium protrusions in lithium metal symmetric cells containing a solid block copolymer electrolyte was studied as a function of time in 3D using time-resolved X-ray tomography. These measurements enabled determination of the spatial variation in current densities at the plating and stripping electrodes. The initial interelectrode distance was 27 μm. Correlation functions were calculated to reveal the relationships between current densities at the two electrodes and local electrolyte thickness. Current densities at opposing electrode locations during protrusion growth is uncorrelated until the local interelectrode distance decreases to less than 6 μm, just before the cell shorts. Mass balance was used to determine the area from which lithium ions that form a protrusion were stripped. Computational modeling of the plating and stripping process reveals the interplay between electrochemical and mechanical driving forces and their effect on nonuniform current distribution. Model predictions were compared with experiments without resorting to any adjustable parameters. The computed correlation functions were in qualitative agreement with experiments. Finally, the model was used to calculate contour plots of electrochemical potential within the electrolyte, shedding light on how geometry, salt concentration, interelectrode distance, and mechanical stress influence local rates of electrochemical reaction.

36 MATERIALS SCIENCE↗

Performance Assessment of Photovoltaic Panels Using Impedance Spectroscopy

The goal of this project was to develop a technique for measuring internal characteristics of a PV module using light modulation under a fixed voltage bias while measuring the resulting alternating current. This technique, light-intensity modulated impedance spectroscopy (LIMIS), has the promise of detecting early signs of panel aging and degradation that could be used for example by solar farm operators to have early warnings to repair or replace panels to maintain reliability of the overall PV array. LIMIS would be complementary with the previously developed electrochemical impedance spectroscopy (EIS), which uses an alternating voltage applied electrically to a solar cell with a similar alternating current measurement. EIS has mostly been developed for individual PV cells rather than whole modules. The project was intended to assess what different information could be revealed by LIMIS, which may in some cases be more scalable to larger modules and potentially more practical to apply in field measurements without needing to electrically disconnect PV modules. We began with small 10 W PV modules and built a testbed capable of oscillating the light intensity with frequencies up to 50 kHz. In parallel, we built a large testbed for testing large 250 W PV modules. Meanwhile, we developed procedures for established measurement techniques: current–voltage (I–V), EIS, and electroluminescence (EL) imaging, where panels are subjected to forward bias while their infrared emission is recorded using a camera modified to be sensitive to IR wavelengths. In addition, we developed protocols for accelerated aging of PV modules in two ways. Thermal cycling from –40°C to +90°C simulates the diurnal temperature cycles on a rooftop. Mechanical stress by dropping a 227 g ball from a height of 1 m simulates damage such as that due to hail impacts.

14 SOLAR ENERGY↗

Revealing Micro-Scale Doping Variations in Thin-Films via Simultaneous Luminescence and Current Collection Measurements

Doping thin films used for photovoltaic absorbers is both critical to maximize device voltage and challenging due to complex interactions between point defects in these materials. Such interactions can result in compensation of the intended dopant species, meaning that the active charge-carrier concentration is lower than the concentration incorporated dopants. Charge-carrier compensation is directly related to the open-circuit voltage (VOC) deficit, or magnitude of VOC relative to the theoretical limit. Understanding how the carrier concentration varies within thin-films is necessary to design material processing schedules to minimize this VOC deficit and produce more efficient devices. Unfortunately, measurements of the free carrier concentration are generally relevant at the device level and cannot resolve local differences. Resolving local doping differences in thin-films such as Cd(Se,Te), CZTS, and CIGSe requires techniques with micron or sub-micron spatial resolution due to the polycrystalline structure as well as intended and unintended composition variations in these materials. In this contribution, we show how simultaneous measurement of cathodoluminescence (CL) and electron-beam-induced current (EBIC) can be used to expose doping variations in Cd(Se,Te) thin-films. Simultaneous collection of these signals reveals unexpected differences in the electric field strength through the device thickness due to spatial variation in the carrier concentration.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Port Impedance Measurement and Current Injection Response Analysis for PLCs

Programmable Logic Controllers (PLCs) are used to control devices throughout the power system since they have fast control capabilities and can utilize multiple types of communication interfaces. Therefore, studying and mitigating their vulnerabilities to electromagnetic pulse is important for the reliability of PLC operations. Here, in this paper, an effective impedance measurement scheme is proposed and demonstrated for three PLCs to estimate their susceptibility to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then different parameters of the impedance measurement setup are explored. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulsed Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of the PLC.

42 ENGINEERING↗

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

PLC-based Impedance Measurement and Current Injection Response Analysis

Studying and mitigating the vulnerabilities of Programmable Logic Controllers (PLCs) to electromagnetic pulse is important for the reliability of the power system. In this paper, an effective impedance measurement scheme is proposed to estimate the susceptibility of PLCs to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulse Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of PLC.

Qiu, Wei↗

Classical vs. quantum plasmon-induced molecular transformations at metallic nanojunctions

Chemical transformations near plasmonic metals have attracted increasing attention in the past few years. Specifically, reactions occurring within plasmonic nanojunctions that can be detected via surface and tip-enhanced Raman (SER and TER) scattering were the focus of numerous reports. In this context, even though the transition between localized and nonlocal (quantum) plasmons at nanojunctions is documented, its implications on plasmonic chemistry remain poorly understood. We explore the latter through AFM-TER-current measurements. We use two molecules: i) 4-mercaptobenzonitrile (MBN) that reports on the (non)local fields and ii) 4-nitrothiophenol (NTP) that features defined signatures of its neutral/anionic forms and dimer product, 4,4′-dimercaptoazobenzene (DMAB). The transition from classical to quantum plasmons is established through our optical measurements: It is marked by molecular charging and optical rectification. Simultaneously recorded force and current measurements support our assignments. In the case of NTP, we observe the parent and DMAB product beneath the probe in the classical regime. Further reducing the gap leads to the collapse of DMAB to form NTP anions. The process is reversible: Anions subsequently recombine into DMAB. Our results have significant implications for AFM-based TER measurements and their analysis, beyond the scope of this work. In effect, when precise control over the junction is not possible (e.g., in SER and ambient TER), both classical and quantum plasmons need to be considered in the analysis of plasmonic reactions

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Measuring Charged Current Muon Neutrino Cross Sections on Oxygen with the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a $26$-ton gadolinium-doped water Cherenkov detector on-axis of the Booster Neutrino Beam (BNB) at Fermilab. With ANNIE, this dissertation provides the first results of a high statistics muon neutrino charged current cross section on oxygen at a short baseline on axis. This thesis explains the necessity of the measurements and details how the measurements are performed. Focus is given on the physics behind the models used to predict neutrino cross sections. The measurements include the CC inclusive and CC$0\pi$ cross section channels. This thesis details the processes of event selection, reconstruction, handling systematics, and unfolding as part of cross section measurements. A data unblinding procedure is documented and acts as the first implementation of data unblinding in ANNIE. These results provide additional constraints on existing neutrino interaction models and are the necessary steps for a joint analysis with liquid Argon experiments also on the BNB line.

Minock, James [Rutgers U., Piscataway (main)]↗

Fermilab Muon $g - 2$ experiment: Current status

The Muon $g$ - 2 experiment at Fermilab (E989) is currently measuring the muon magnetic anomaly with a goal precision of 140 part per billion, which will be a fourfold precision improvement over the current best measurement by the previous Muon $g$ -2 experiment at the Brookhaven Laboratory (BNL). The BNL-measured value of the muon magnetic anomaly and the corresponding Standard Model (SM) best estimate differ by more than three standard deviation which inspired the current measurement as well as a theoretical drive for a significantly more precise calculation of the muon magnetic anomaly to rule out (or establish) statistical fluctuation as the origin of such a huge discrepancy. Stable central values along with 4-fold precision improvements in both theoretical (SM) and experimental fronts, would imply a ~ 7σ discrepancy and that will be a clear hint of the physics beyond the Standard Model. Such an unprecedented precision demands state-of-the-art technological improvements in all involved components to keep the systematic uncertainty below 70 ppb. This paper reports the current status of the E989 experiment after two years of data acquisition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗