Cryogenic Limb Array Etalon Spectrometer (CLAES) S/N001 cryostat test results

The results of a test program designed to verify the operational and thermal performance of the Cryogenic Limb Array Etalon Spectrometer (CLAES) S/N001 Ne/CO2 cryostat, as monitored and serviced by the Data Acquisition System and Ground Support Equipment, are presented. The S/N001 model test assembly consists of the S/N001 configuration coupled with an instrument thermal mass simulator (ITMS) for simulating the thermal behavior of the instrument package. The test data for the cryostat include the rate of temperature decrease of the various parts of the cryostat/ITMS and the final equilibrium temperatures of the shields, thermal links, and tank. The test results showed that system heat rates, operating temperatures, and expected end-of-life temperature predictions all agree with predictions within estimated margins.

Horsley, W. J.↗

A simplified generic cryostat thermal model for predicting cryogen mass and lifetime

This study presents a simple generic cryostat thermal model developed for predicting cryogen mass and the lifetime of cryogenic space telescopes. The model is based on a lumped parameter representation of eight nodes and over 35 conductors. The major telescope Dewar components represented as nodes are the main cryogen tank, the three vapor-cooled shields, the outer shell, barrel baffle, and the barrel baffle heat exchanger. The input to the model consists of the vapor-cooled shield, support straps and instrument cable geometry, and the cryostat heat loads from the instrument and through the aperture. The predictions from the model were compared with those from the more detailed models of IRAS, COBE, and SIRTF. Correlation of the helium flow rates of the IRAS and COBE Dewars was 12 percent above the actual flight or ground test data and for SIRTF it was less than 2 percent of the prediction from the detailed model.

Birur, G. C.↗

CLAES cryostat on-orbit performance versus ground test predictions

The paper describes the Cryogenic Limb Array Etalon Spectrometer (CLAES) launched on September 12, 1991 aboard the NASA Goddard's Upper Atmosphere Research Satellite the purpose of which is to measure the global concentrations of stratospheric species and their temperature, as a function of altitude. Particular attention is given to the design-level thermal predictions and their correlation to the results of ground tests, and to the on-orbit performance of CLAES. Also presented are data on the cryostat's thermal performance during ground operations, at spacecraft integration and during launch preparations. The CLAES functional block diagram and the cryostat schematic diagram are included.

Bell, Greg A.↗

Analysis Supporting MSFC Cryostat Testing Unit

This report summarizes the results obtained from an analysis of the NASA Marshall Spaceflight Center (MSFC) cryostat testing unit. A finite element model was generated to determine both temperature distribution and stress distribution in the cryostat testing unit for load conditions supplied by MSFC. This report contains the results of that analysis.

Foster, Winfred A., Jr.↗

Design and Performance of the HESSI Cryostat

The High Energy Solar Spectroscopic Imager (HESSI) spacecraft, to be launched in July 2000, will be used to observe the Sun with the finest angular and energy resolutions ever achieved from a few keV to hundreds of keV. The spacecraft will use an array of nine germanium (Ge) detectors, each 7.1 cm in diameter and 8.5 cm long, operating at 75K. The detectors are mounted in a cryostat on a common cold plate, and cooled by a small Stirling-cycle cryocooler. This paper describes the design of the cryostat, special accommodations for the Ge detectors, interfaces with the cryocooler, and thermal performance of the engineering test unit.

Boyle, R.↗

Thermal Performance of Aged and Weathered Spray-On Foam Insulation (SOFI) Materials Under Cryogenic Vacuum Conditions (Cryostat-4)

The NASA Cryogenics Test Laboratory at Kennedy Space Center conducted long-term testing of SOFI materials under actual-use cryogenic conditions with Cryostat-4. The materials included in the testing were NCFI 24-124 (acreage foam), BX-265 (close-out foam, including intertank flange and bipod areas), and a potential alternate material, NCFI 27-68, (acreage foam with the flame retardant removed). Specimens of these materials were placed at two locations: a site that simulated aging (the Vehicle Assembly Building [VAB]) and a site that simulated weathering (the Atmospheric Exposure Test Site [beach site]). After aging/weathering intervals of 3, 6, and 12 months, the samples were retrieved and tested for their thermal performance under cryogenic vacuum conditions with test apparatus Cryostat-4.

Source record↗

Building Bigger, Better Instruments with Dry Cryostats

The cylindrical instrument volume allowable n SOFIA is large, comprising perhaps 400 liters at 4K. However, the cryogen accommodation to enable this environment consumes roughly 20% of the volume, and worsens rues, airworthiness/safety, and handling/operation, Present-day pulse tube coolers have negligible cold volumes, provide adequate cooling powers, and reach colder temperatures than stored cryogen. In addition, they permit safer, more reliable, lower maintenance instrument operation. While the advantages of dry cryostats are well-known and commonly used in labs and ground-based astronomical facilities, SOFIA would require some charges in accommodations to permit a pulse tube cooler to operate on board, Whil e these changes are not negligible, we present our investigation into the feasibility and desirability of making SOFIA a dry cryostat-capable observatory

Benford, Dominic J.↗

Quick-Replacement High-Temperature Superconducting Current Leads for Use in a Research Cryostat

We report the use of a series of high-temperature superconducting leads in a cryostat that require no soldering to replace in the event of a failed lead. The temperature range spanned by the leads is 50 to 3 degrees Kelvin and they typically carry currents up to 4 amperes although they have a much higher capacity in this temperature range. The leads are integrated into the cryostat by clamping both ends to gold-plated copper pads. Support of the leads over the 25-centimeter length is provided by a simple G10 strong back. Details of the clamping interface, measurements of joint resistances, and other interesting observations will be discussed.

Superconductivity↗

Development of the Facet Cryostat

A proof of concept prototype cryostat has been developed to demonstrate the ability to accommodate low temperature science investigations within the constraints of the Hitchhiker siderail carrier on the Space Shuttle.

space cryogenics cryostats superfluid helium neon↗

Superconducting magnet and cryostat for a space application

The paper describes the design concepts, development, and testing of a superconducting coil and cryostat for an orbiting superconducting magnetic spectrometer. Several coils were subject to overall thermal performance and coil charging tests. The coils have low but persistent currents and have proven themselves to be rugged and reliable for mobile balloon flights. Satellite experiments will be conducted on a new, similar design.

Pope, W. L.↗

Cryostat system for temperatures on the order of 2 deg K or less

A cryostat system for cooling a device to a temperature on the order of 2 K or less includes a dewar, in which helium, in other than the superfluid state, is stored. Helium flows from the dewar through a heat exchanger tube and a restrictor tube, which controls the helium flow rate, into the cavity of a heat exchanger, to whose outer wall the device to be cooled is attached. A pressure regulator value controls the pressure in the cavity to be very low. As the helium exits the restrictor tube into the cavity, due to low pressure cavity, it becomes an aerosol mixture of helium gas and superfluid helium droplets at the desired temperature. The latter form a thin layer or film of superfluid helium on the inner side of the heat exchanger wall and thereby cool the device, which is attached to the wall to the desired temperature.

Miller, C. G.↗

Cryostatic influence of formvar coatings on sizing of the stabilizer in composite NbTi-Cu superconductors

Often undesirable low energy densities are associated with extreme safety measures (e.g. cryostatic stability) in large superconducting magnets. Therefore, a medium-sized, formvar-coated composite NbTi alloy, Cu-stabilized, has been studied (48 filaments, approximately square cross section about 1/5 cm thickness). Thermal quench behavior (caused by heating) was investigated in various fluid states of He4, including pressurized and superfluid He4. The data obtained support existence of a particular coating thickness ('limiting' thickness) with the property that thermal boundary conditions of uncoated superconductors at a quench are not deteriorated.

Caspi, S.↗

Low cost cryostat

A cryostat for use in a low or a substantially gravity-free environment adapted to cool an experiment through the use of helium 2, or helium in its super fluid state is characterized by a number of interchangeable daughter dewars and helium supply or mother dewar. A low pressure venting system is provided for converting helium contained in the mother dewar to a superfluid state for use as a primary cryogen. Each daughter dewar is adapted to be removably mounted in mated relation on the mother dewar and is characterized by support for an experiment package, a source of helium to be employed as a secondary cryogen. A heat pipe is suspended from each daughter dewar and adapted to be extended into the mother dewar for facilitating cooling of the secondary cryogen. A transfer of heat from the package to the primary cryogen, via the secondary cryogen, is accommodated as a film flow of helium 2 progresses from the heat pipe to the experiment dewar.