Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Convergent beam electron diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

35 records · Page 2

Local negative permittivity and topological phase transition in polar skyrmions

Topological solitons such as magnetic skyrmions have drawn attention as stable quasi-particle-like objects. The recent discovery of polar vortices and skyrmions in ferroelectric oxide superlattices has opened up new vistas to explore topology, emergent phenomena and approaches for manipulating such features with electric fields. Using macroscopic dielectric measurements, coupled with direct scanning convergent beam electron diffraction imaging on the atomic scale, theoretical phase-field simulations and second-principles calculations, we demonstrate that polar skyrmions in (PbTiO 3 ) n /(SrTiO 3 ) n superlattices are distinguished by a sheath of negative permittivity at the periphery of each skyrmion. This enhances the effective dielectric permittivity compared with the individual SrTiO 3 and PbTiO 3 layers. Moreover, the response of these topologically protected structures to electric field and temperature shows a reversible phase transition from the skyrmion state to a trivial uniform ferroelectric state, accompanied by large tunability of the dielectric permittivity. Pulsed switching measurements show a time-dependent evolution and recovery of the skyrmion state (and macroscopic dielectric response). The interrelationship between topological and dielectric properties presents an opportunity to simultaneously manipulate both by a single, and easily controlled, stimulus, the applied electric field. Polar skyrmions are topologically protected structures that can exist in (PbTiO 3 ) n /(SrTiO 3 ) n superlattices. Here, it is shown that they have negative permittivity at the surface, and that they can undergo a reversible phase transition with large dielectric tunability under an electric field.

36 MATERIALS SCIENCE↗

Controlling the symmetry of cadmium arsenide films by epitaxial strain

Epitaxial strains offer unique opportunities to obtain topological states in thin films and heterostructures that do not exist in their bulk counterparts. Here, we investigate the point group symmetries of coherently strained films of cadmium arsenide (Cd 3 As 2 ), a prototype three-dimensional Dirac semimetal, by convergent beam electron diffraction. We report a loss of the fourfold rotational axis and adoption of the orthorhombic mmm point group in (112)-oriented films under biaxial compressive stress. (001)-oriented Cd 3 As 2 films that are under a small biaxial tensile stress retain the fourfold rotational symmetry that protects the bulk nodes but adopt the non-centrosymmetric 4mm point group symmetry. This, in turn, suggests that (001) films adopt a different crystal structure in biaxial tension, one that differs in the arrangement of the ordered Cd vacancies that are an inherent feature of the crystal structure of Cd 3 As 2 and that are key to its nodal electronic structure. Density functional theory calculations confirm the experimental findings of the stability of the non-centrosymmetric structure under biaxial tension, whereas the centrosymmetric structure is stable under biaxial compression. The results show that bulk Cd 3 As 2 is already close to structural instability and showcase the extraordinary tunability of the topological states of Cd 3 As 2 .

36 MATERIALS SCIENCE↗

Wehnelt photoemission in an ultrafast electron microscope: Stability and usability

We tested and compared the stability and usability of three different cathode materials and configurations in a thermionic-based ultrafast electron microscope: (1) on-axis thermionic and photoemission from a custom 100 μm diameter LaB 6 source with a graphite guard ring, (2) off-axis photoemission from the Ni aperture surface of the Wehnelt electrode, and (3) on-axis thermionic and photoemission from a custom 200 μm diameter polycrystalline Ta source. For each cathode type and configuration, including the Ni Wehnelt aperture, we illustrate how the photoelectron beam-current stability is deleteriously impacted by simultaneous cooling of the source following thermionic heating. Furthermore, we demonstrate usability via collection of parallel- and convergent-beam electron diffraction patterns and by formation of the optimum probe size. We find that usability of the off-axis Ni Wehnelt-aperture photoemission is at least comparable to on-axis LaB 6 thermionic emission, as well as to on-axis photoemission [the heretofore conventional approach to ultrafast electron microscopy (UEM) in thermionic-based instruments]. However, the stability and achievable beam currents for off-axis photoemission from the Wehnelt aperture were superior to that of the other cathode types and configurations, regardless of the electron-emission mechanism. Beam-current stability for this configuration was found to be ±1% (one standard deviation from the mean) for 70 min (longest duration tested), and steady-state beam current was reached within the sampling-time resolution used here (~1 s) for 15 pA beam currents (i.e., 460 electrons per packet for a 200 kHz repetition rate). Repeatability and robustness of the steady-state condition were also found to be within ±1% of the mean. We discuss the implications of these findings for UEM imaging and diffraction experiments, for pulsed-beam damage measurements, and for practical switching between optimum conventional TEM and UEM operation within the same instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Antiphase boundaries in epitaxially grown beta-SiC

When the surface of beta-SiC, grown epitaxially on (001) silicon by chemical vapor deposition, is chemically etched, boundaries appear which may be observed by optical or scanning electron microscopy. Examination by plan-view and cross-sectional transmission electron microscopy shows boundaries in the film which exhibit line or fringe contrast. Convergent beam electron diffraction has been used to show that these boundaries separate domains that are in an antiphase relationship to each other. A model is presented which discusses the formation of these domains from independent nucleation on a stepped substrate surface.

Pirouz, P.↗

Formation of the lamellar structure in Group IA and IIID iron meteorites

Analytical EM, light microscopy, and electron microprobe analysis are used to study the lamellar plessite structure of Group IA and IIID iron meteorites. The alpha lamellae in IIID structures contained a compositional gradient from 6.1 + or - 0.7 wt pct Ni at the center of the alpha lamellae to 3.6 + or - 0.5 wt pct at the alpha/gamma interface. For the Group IA irons, compositions of 4 wt pct Ni in alpha and about 48 wt pct Ni in gamma are found. Convergent beam electron diffraction was used to characterize the orientation relations at the alpha/gamma interface in the lamellar regions of both Group IA and IIID. The phase transformations responsible for the observed lamellar structure in the IA and IIID chemical groups were also investigated.

Kowalik, J. A.↗

Nonequilibrium synthesis of NbAl3 and Nb-Al-V alloys by laser cladding. I - Microstructure evolution

The evolution of the microstructure in NbAl3 synthesized by a laser cladding technique (a rapid solidification process, with cooling rates up to 10 exp 6 C/sec) is investigated, and the phases are identified using convergent beam electron diffraction. Two new metastable phases were identified and characterized in detail. The effect of adding V on the final microstructure was also investigated, and the various phase chemistries and the partitioning of different elements into different phases were studied.

Sircar, S.↗

An orbital strategy for regulating the Jahn–Teller effect

ABSTRACT The Jahn–Teller effect (JTE) arising from lattice–electron coupling is a fascinating phenomenon that profoundly affects important physical properties in a number of transition-metal compounds. Controlling JT distortions and their corresponding electronic structures is highly desirable to tailor the functionalities of materials. Here, we propose a local coordinate strategy to regulate the JTE through quantifying occupancy in the ${{d}_{{{z}^2}}}$ and ${{d}_{{{x}^2} - {{y}^2}}}$ orbitals of Mn and scrutinizing the symmetries of the ligand oxygen atoms in MnO6 octahedra in LiMn2O4 and Li0.5Mn2O4. The effectiveness of such a strategy has been demonstrated by constructing P2-type NaLixMn1–xO2 oxides with different Li/Mn ordering schemes. In addition, this strategy is also tenable for most 3d transition-metal compounds in spinel and perovskite frameworks, indicating the universality of local coordinate strategy and the tunability of the lattice–orbital coupling in transition-metal oxides. This work demonstrates a useful strategy to regulate JT distortion and provides useful guidelines for future design of functional materials with specific physical properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-angle Precession Electron Diffraction (MAPED): A Versatile Approach to 4D-STEM Precession

Precession of a converged beam during acquisition of a 4D-STEM dataset improves strain, orientation, and phase mapping accuracy by averaging over continuous angles of illumination. Precession experiments usually rely on integrated systems, where automatic alignments lead to fast, high-quality results. The dependence of these experiments on specific hardware and software is evident even when switching to nonintegrated detectors on a precession tool, as experimental set-up becomes challenging and time-consuming. Here, we introduce multi-angle precession electron diffraction (MAPED): a method to perform electron diffraction by collecting sequential 4D-STEM scans at different incident beam tilts. The multiple diffraction datasets are averaged together postacquisition, resulting in a single dataset that minimizes the impact of the curvature and orientation of the Ewald sphere relative to the crystal under study. Our results demonstrate that even four additional tilts improved measurement of material properties, namely strain and orientation, as compared to single-tilt 4D-STEM experiments. We show the versatility and flexibility of our MAPED approach with data collected on a number of microscopes with different hardware configurations and a variety of detectors.

4D-STEM↗

4D-STEM of Beam-Sensitive Materials

We report that a scanning electron nanobeam diffraction, or 4D-STEM (four-dimensional scanning transmission electron microscopy), is a flexible and powerful approach to elucidate structure from "soft" materials that are challenging to image in the transmission electron microscope because their structure is easily damaged by the electron beam. In a 4D-STEM experiment, a converged electron beam is scanned across the sample, and a pixelated camera records a diffraction pattern at each scan position. This four-dimensional data set can be mined for various analyses, producing maps of local crystal orientation, structural distortions, crystallinity, or different structural classes. Holding the sample at cryogenic temperatures minimizes diffusion of radicals and the resulting damage and disorder caused by the electron beam. The total fluence of incident electrons can easily be controlled during 4D-STEM experiments by careful use of the beam blanker, steering of the localized electron dose, and by minimizing the fluence in the convergent beam thus minimizing beam damage. This technique can be applied to both organic and inorganic materials that are known to be beam-sensitive; they can be highly crystalline, semicrystalline, mixed phase, or amorphous. One common example is the case for many organic materials that have a π-π stacking of polymer chains or rings on the order of 3.4-4.2 Å separation. If these chains or rings are aligned in some regions, they will produce distinct diffraction spots (as would other crystalline spacings in this range), though they may be weak or diffuse for disordered or weakly scattering materials. We can reconstruct the orientation of the π-π stacking, the degree of π-π stacking in the sample, and the domain size of the aligned regions. This Account summarizes illumination conditions and experimental parameters for 4D-STEM experiments with the goal of producing images of structural features for materials that are beam-sensitive. We will discuss experimental parameters including sample cooling, probe size and shape, fluence, and cameras. 4D-STEM has been applied to a variety of materials, not only as an advanced technique for model systems, but as a technique for the beginning microscopist to answer materials science questions. It is noteworthy that the experimental data acquisition does not require an aberration-corrected TEM but can be produced on a variety of instruments with the right attention to experimental parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Crystal Orientation Mapping in py4DSTEM using Sparse Correlation Matching

Crystalline materials used in technological applications are often complex assemblies composed of multiple phases and differently oriented grains. Robust identification of the phases and orientation relationships from these samples is crucial, but the information extracted from the diffraction condition probed by an electron beam is often incomplete. We have developed an automated crystal orientation mapping (ACOM) procedure which uses a converged electron probe to collect diffraction patterns from multiple locations across a complex sample. We provide an algorithm to determine the orientation of each diffraction pattern based on a fast sparse correlation method. We demonstrate the speed and accuracy of our method by indexing diffraction patterns generated using both kinematical and dynamical simulations. We have also measured orientation maps from an experimental dataset consisting of a complex polycrystalline twisted helical AuAgPd nanowire. From these maps we identify twin planes between adjacent grains, which may be responsible for the twisted helical structure. All of our methods are made freely available as open source code, including tutorials which can be easily adapted to perform ACOM measurements on diffraction pattern datasets.

36 MATERIALS SCIENCE↗

Multimodal Nanoscale Mapping of Local Structure and CO 2 Adsorption in Metal–Organic Frameworks

Diamine functionalization of the metal−organic framework Mg 2 (dobpdc) (dobpdc 4− = 4,4′-dioxidobiphenyl-3,3′-dicarboxylate) significantly enhances its selectivity for CO 2 capture from flue gases and air. The structure and CO 2 capacity of such materials are typically assessed using bulk techniques that rely on averaging signal over large ensembles of unit cells, obscuring local heterogeneities, such as variations in CO 2 occupancy across individual nanocrystals. To resolve this limitation, we demonstrate a multimodal, nanoscale characterization of Mg 2 (dobpdc) appended with 1,3-diaminopropane. By employing recently developed characterization techniques at progressively smaller length scales, we uncover insights from correspondingly smaller populations of unit cells. First, we use parallel-beam 3D electron diffraction (3D ED) to identify a prominent expansion in lattice parameters upon desorption of CO 2 , as observed at the level of single nanocrystals. Second, we use convergent-probe 4D scanning transmission electron microscopy (4D-STEM) to quantify associated differences in lattice strain as a function of gas loading and diamine appending. These measurements sample small subvolumes within individual nanocrystals. Finally, we apply infrared scattering scanning near-field optical microscopy (IR s- SNOM) to confirm variable CO 2 chemisorption across adsorption sites at the surface of single nanocrystals. This multimodal, multiscale approach allows us to map heterogeneity within individual nanocrystals. Collectively, these findings emphasize the importance of local, nanoscale characterization of metal−organic frameworks in revealing previously unresolvable features that impact their performance.

Karstens, Sarah L. [University of California, Berk↗

Relativistic ultrafast electron diffraction at high repetition rates

The ability to resolve the dynamics of matter on its native temporal and spatial scales constitutes a key challenge and convergent theme across chemistry, biology, and materials science. The last couple of decades have witnessed ultrafast electron diffraction (UED) emerge as one of the forefront techniques with the sensitivity to resolve atomic motions. Increasingly sophisticated UED instruments are being developed that are aimed at increasing the beam brightness in order to observe structural signatures, but so far they have been limited to low average current beams. Here, we present the technical design and capabilities of the HiRES (High Repetition-rate Electron Scattering) instrument, which blends relativistic electrons and high repetition rates to achieve orders of magnitude improvement in average beam current compared to the existing state-of-the-art instruments. The setup utilizes a novel electron source to deliver femtosecond duration electron pulses at up to MHz repetition rates for UED experiments. Instrument response function of sub-500 fs is demonstrated with < 100 fs time resolution targeted in future. We provide example cases of diffraction measurements on solid-state and gas-phase samples, including both micro- and nanodiffraction (featuring 100 nm beam size) modes, which showcase the potential of the instrument for novel UED experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase retrieval for short wavelength orbital angular momentum beams using knife-edge diffraction

Laser beams operating in high order transverse modes, especially orbital angular momentum (OAM) modes, have been used increasingly in many frontier research areas. The characterization of these laser modes and the related component analysis can be carried out using the retrieved optical phase. However, conventional iterative phase retrieval methods, when applied to pure OAM modes, may fail because their convergence depends on the choice of the initial phase. Here, we present an improved phase retrieval method which can incorporate additional phase information obtained using knife-edge diffraction. Using no additional optics or few optics available in a wide spectral range, this method is particularly suitable for short wavelength lasers such as free-electron lasers (FELs) in the VUV, EUV, and X-ray regimes. Finally, this method has been tested using simulated beams, and successfully applied to experimentally generated beams from a HeNe laser and an FEL.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced High Brilliance X-Ray Source

The possibility to dramatically increase the efficiency of laboratory based protein structure measurements through the use of polycapillary X-ray optics was investigated. This project initiated April 1, 1993 and concluded December 31, 1996 (including a no cost extension from June 31, 1996). This is a final report of the project. The basis for the project is the ability to collect X-rays from divergent electron bombardment laboratory X-ray sources and redirect them into quasiparallel or convergent (focused) beams. For example, a 0.1 radian (approx. 6 deg) portion of a divergent beam collected by a polycapillary collimator and transformed into a quasiparallel beam of 3 millradian (0.2 deg) could give a gain of 6(exp 2)/0.2(exp 2) x T for the intensity of a diffracted beam from a crystal with a 0.2 deg diffraction width. T is the transmission efficiency of the polycapillary diffraction optic, and for T=0.5, the gain would be 36/0.04 x O.5=45. In practice, the effective collection angle will depend on the source spot size, the input focal length of the optic (usually limited by the source spot-to-window distance on the x-ray tube) and the size of the crystal relative to the output diameter of the optic. The transmission efficiency, T, depends on the characteristics (fractional open area, surface roughness, shape and channel diameter) of the polycapillary optic and is typically in the range 0.2-0.4. These effects could substantially reduce the expected efficiency gain. During the course of this study, the possibility to use a weakly focused beam (0.5 deg convergence) was suggested which could give an additional 10-20 X efficiency gain for small samples . Weakly focused beams from double focusing mirrors are frequently used for macromolecular crystallography studies. Furthermore the crystals are typically oscillated by as much as 2 deg during each X-ray exposure in order to increase the reciprocal space (number of crystal planes) sampled and use of a slightly convergent beam could, in principle, provide a similar sampling benefit without oscillation. Although more problematic, because of complications in analyzing the diffraction patterns, it was also suggested that even more extreme beam convergence might be used to give another order of magnitude intensity gain and even smaller focused spot size which could make it possible to study smaller protein crystals than can be studied using standard laboratory based X-ray diffraction systems. This project represents the first systematic investigation of these possibilities. As initially proposed, the contract included requirements for design, purchase, evaluation and delivery of three polycapillary lenses to the Laboratory for Structural Biology at MSFC and demonstration of such optics at MSFC for selected protein crystal diffraction applications.

Gibson, Walter M.↗

Multibeam Electron Diffraction

One of the primary uses for transmission electron microscopy (TEM) is to measure diffraction pattern images in order to determine a crystal structure and orientation. In nanobeam electron diffraction (NBED), we scan a moderately converged electron probe over the sample to acquire thousands or even millions of sequential diffraction images, a technique that is especially appropriate for polycrystalline samples. However, due to the large Ewald sphere of TEM, excitation of Bragg peaks can be extremely sensitive to sample tilt, varying strongly for even a few degrees of sample tilt for crystalline samples. In this paper, we present multibeam electron diffraction (MBED), where multiple probe-forming apertures are used to create multiple scanning transmission electron microscopy (STEM) probes, all of which interact with the sample simultaneously. We detail designs for MBED experiments, and a method for using a focused ion beam to produce MBED apertures. We show the efficacy of the MBED technique for crystalline orientation mapping using both simulations and proof-of-principle experiments. We also show how the angular information in MBED can be used to perform 3D tomographic reconstruction of samples without needing to tilt or scan the sample multiple times. Finally, we also discuss future opportunities for the MBED method.

47 OTHER INSTRUMENTATION↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Hybrid height and slope figuring method for grazing-incidence reflective optics

Grazing-incidence reflective optics are commonly used in synchrotron radiation and free-electron laser facilities to transport and focus the emitted X-ray beams. To preserve the imaging capability at the diffraction limit, the fabrication of these optics requires precise control of both the residual height and slope errors. However, all the surface figuring methods are height based, lacking the explicit control of surface slopes. Although our preliminary work demonstrated a one-dimensional (1D) slope-based figuring model, its 2D extension is not straightforward. In this study, a novel 2D slope-based figuring method is proposed, which employs an alternating objective optimization on the slopes in the x - and y -directions directly. An analytical simulation revealed that the slope-based method achieved smaller residual slope errors than the height-based method, while the height-based method achieved smaller residual height errors than the slope-based method. Therefore, a hybrid height and slope figuring method was proposed to further enable explicit control of both the height and slopes according to the final mirror specifications. An experiment to finish an elliptical-cylindrical mirror using the hybrid method with ion beam figuring was then performed. Both the residual height and slope errors converged below the specified threshold values, which verified the feasibility and effectiveness of the proposed ideas.

36 MATERIALS SCIENCE↗